Omron HBF-702T User manual

Thank you for purchasing the OMRON Body Composition Monitor.
Before using this unit, please be sure to read this Instruction Manual carefully to
understand the safe and proper use.
Please store this Instruction Manual carefully for future reference.
5659713-6A
Issue date: 2020-12-28
Body Composition Monitor
HBF-702T

1
HBF-702T
Body Composition Monitor
This unit can measure and display the following parameters.
-Body Weight
-Body Fat (in %)
-Visceral Fat (up to 30 levels)
-Segmental Skeletal Muscle (in %)
-Segmental Subcutaneous Fat (in %)
-Resting Metabolism (in kcal)
-BMI (Body Mass Index)
-Body Age
This unit is intended to be operated by adults who can understand this instruction manual. It is not for professional
use in hospitals or other medical facilities. It is intended for home use only.
Please read this instruction manual carefully before use and for further information on the individual functions.
Contents
Before using the unit...............................................................................................................................2
Notes on Safety .......................................................................................................................................... 2
1. Know Your Unit...................................................................................................................................... 4
2. Installing and Replacing the Batteries .................................................................................................. 6
3. Initial Setting ......................................................................................................................................... 7
3.1 Setting On Your Smart Device ........................................................................................................ 7
3.2 Setting On The Unit ........................................................................................................................ 7
4. Registering the Personal Data .............................................................................................................. 9
5. How to Take a Measurement Accurately............................................................................................. 11
5.1 Correct postures during the measurement ................................................................................... 11
5.2 Recommended measurement Time period and users.................................................................. 12
5.3 About the "0 kg correction" (Caution for storing) .......................................................................... 12
5.4 How to implement the "0 kg correction"........................................................................................ 12
Operating instructions..........................................................................................................................13
6. Measuring Weight and Body Composition.......................................................................................... 13
Using the Memory Function .................................................................................................................17
7. Viewing the Measurement Results on the unit.................................................................................... 17
8.
View the Measurement Results on Your Smart Device ...................................................................................... 18
When necessary ....................................................................................................................................19
9. Selecting Your Personal Number and Taking a Measurement ............................................................ 19
10. Using the Guest Mode (Unrecorded Mode)........................................................................................ 20
11. Measuring Weight Only....................................................................................................................... 22
12. Changing/Deleting Personal Data ...................................................................................................... 23
13. Deleting the Communication Setting................................................................................................... 24
14. Maintenance and Storage................................................................................................................... 25
15. Troubleshooting................................................................................................................................... 26
16. Technical Data .................................................................................................................................... 29
Information on body composition........................................................................................................31
17. Information on Body Composition....................................................................................................... 31
18. Measurement Results Interpretation Diagrams ................................................................................. 33

2
Before using the unit
Notes on Safety
Symbols and definitions are as follows:
Danger Improper use may cause danger resulting in death or serious injury.
Warning
Improper use may result in possible death or serious injury.
Caution Improper use may result in injury or property damage.
Danger
•Never use this unit in combination with the following medical electronic devices.
(1) Medical electronic implants such as pacemakers.
(2) Electronic life support systems such as an artificial heart/lung.
(3) Portable electronic medical devices such as an electrocardiograph.
This unit could cause these devices to malfunction, posing a considerable health risk to users of these
devices.
Warning
•Keep the unit out of the reach of young children. Contains small parts that may cause a choking
hazard if swallowed by infants.
•Do not use the unit on slippery surfaces, such as a wet floor.
•Do not jump onto the unit, or bounce on the unit.
•Do not use this unit when your body and/or feet are wet, such as after taking a bath.
•Stand on the unit bare-footed. Standing on the unit with socks on may cause you to slip and
injure yourself.
•Do not step on the panel unit, panel unit holder or the edges of the main unit.
•People with disabilities, or who are physically frail, should always be assisted by another person when
using this unit.
•If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a
physician immediately.
• This product emits radio frequencies (RF) in the 2.4 GHz band. Do not use this product in locations where
RF is restricted, such as on an aircraft or in hospitals.
• As this unit is a precision instrument, do not drop, vibrate, or apply strong shocks.
Caution
•Do not disassemble, repair, or remodel the unit.
• Never start weight reduction or exercise therapy solely based on your own judgement. Be sure to follow
the instructions of a doctor or specialist. Self-diagnosis could injure your health.

3
•During measurement, make sure that no mobile phone or smartphone is near this device. This may
result in incorrect operation of the device and/or cause an inaccurate reading.
•Use batteries specified for this unit. Do not insert the batteries with the polarities in the wrong direction.
•Do not use batteries of different manufacturers or brands together.
•Do not use new and worn batteries together.
•Do not use batteries which have passed the recommended use-by date.
•Remove the batteries from this unit when you are not going to use it for a long period of time
(approximately three months or more).
•If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.
•Do not dispose of batteries in fire.
•When the unit will be used by several people, wipe the unit with a damp cloth moistened with mild
detergent after using it. Then wipe it dry.
•Do not use this unit for purposes other than described in this manual.
•This unit is not for professional use in hospitals or other medical facilities. It is intended for home use
only.
•Remove the panel unit from main unit before stepping on the main unit.
•When inserting panel unit into the main unit, do not touch inside part of grip electrodes metal.
•Do not move the unit by holding the panel unit.
•Do not forcibly pull the cord connecting the Panel Unit and the main unit.
Data Transmission
•Do not replace the battery while your measurement result is being transferred to your smart device.
This may result in the incorrect operation of your monitor and failure to transfer your measurement
result.
•Do not place integrated circuit cards, magnets, metal objects, or other devices that emit
electromagnetic fields near this monitor while your measurement result is being transferred to
your smart device. This may result in the incorrect operation of your unit and failure to transfer
your measurement result.
Incorrect Measurement
Incorrect measurement might occur to the following users:
Elderly people (over 81 years old) / People with a fever / Body builders or highly trained athletes /
Patients undergoing dialysis / Patients with osteoporosis who have very low bone density / Pregnant
women / People with swelling.
•Because the body composition such as body water might greatly deviate from the average value.

4
Before using the unit
1. Know Your Unit
3 4 6 7
5
2
1
Grip Electrodes
Panel Unit
Main Unit
Grip Electrodes
Panel Unit Holder
Cord
Foot Electrodes Foot Electrodes
Feet (×4)
Power Switch
•Pressthisswitchtoturnon/turnoffthepower.
Bluetooth Button
•Pressthisbuttontotransferthedatamanually.
•Pressandholdthisbuttontopairtheunitwithyoursmartdevice.
*Thisbuttonisalsousablewhenthepowerisoff.
SET Button
•Pressthisbuttontoconrmthedata.
Back / Memory Button
•Pressthisbuttontoconrmthedata/selectthepersonalNo./setthepersonal
data.
•Pressthisbuttontoreadthememorydata.
Advance Button
•Pressthisbuttontoconrmthedata/selectthepersonalNo./setthepersonal
data.
BC Button
•Pressthisbuttontoconrmthebodycompositiondata.
AREA Button
•Pressthisbuttontoconrmtheareadata.

5
Display
2
6
2
1
2
2
2
3
5
4
Personal Number Symbol
Displayswhenselectingapersonalnumber.
Weight Symbol
Displayswhenonlymeasuringthebodyweight.
Low Battery symbol
Blinkswhenbatteriesarelow.
Depleted Battery symbol
Displayswhenbatteriesaredepleted.
SYNC Symbol
Blinksordisplayswhenthemeasurementresultsneedtobetransferred
becausethestoredmemoryiseitheralmost,orcompletelyfull.
Bluetooth Symbol
Displayswhentransferringmeasurementresults.
BodyFatPercentage/SubcutaneousFat
Percentage/SkeletalMusclePercentage/BMI
ClassicationIndicator
4 levels: –(Low)/0(Normal)/+(High)/++(VeryHigh)
VisceralFatLevelClassicationIndicator
3 levels: 0(Normal)/+(High)/++(VeryHigh)
(P33)
Components
4 AA alkaline batteries (LR6) Instruction Manual
Quick Start Guide
Setup Instructions

6
Before using the unit
2. Installing and Replacing the Batteries
Please use AA alkaline batteries. Manganese batteries can also be used. Do not use a rechargeable
battery, otherwise it may be extremely shorten use times or may be a unit malfunction occurs.
1 Turn over the unit,
Open battery cover
1
Press the tab of the battery cover along
arrow direction
2
Pull up the tab of the battery cover and open
battery cover
2 Install the batteries in correct polarity as
marked inside the battery compartment
•The side with spring is
3 Close the battery cover
Notes on Battery Life
■Approximately 6 months
(When AA alkaline batteries are used in four measurements, four data transfers a day at a room temperature of 23°C)
•The supplied batteries are for trial use only, they may have a shorter life.
Notes on Battery Replacement
■When the depleted battery symbol appears on the display,
replace all four batteries with new ones.
•Replace all four batteries with new ones (same type) at the same time.
•When the low battery symbol blinks, recommend to replace the
batteries with new ones ahead of time.
■Replace the batteries after turning off the power.
•Personal data stored in the unit are retained even if the batteries are removed.Replacing batteries will not
delete previous readings and personal data stored in the unit.
•Disposal of used batteries should be carried out in accordance with local regulations.
■When the batteries are replaced, you need to reset the date and time. ( P7 )
•If you have already paired with the "OMRON connect" app, press the button to communicate with this
app, then the date and time and personal data will be set automatically.
Notes on Automatic Switch-off of the Power
■Automatic Switch-off of the Power
•When "Err" is displayed (about 10 seconds later).
•If the unit is not used within 1 minute of "0.0 kg" appearing on the display.
•In other cases, if the unit is not used for 3 minutes.
For example, when "Setting Date and Time", "Setting Personal Data" or
"Checking The Measuring Results", etc.
1.5V R6
(LR6.AA)
1.5V R6
(LR6.AA)
Depleted Battery
symbol
1
2
Ta b
Main Unit Back

7
Before using the unit
3. Initial Setting
When the batteries are used for the first time or replaced, it is necessary to make initial setting.
There are two methods for initial setting. Please make initial setting through smart device or the unit.
Put the unit on a hard and level floor.
" " blinks after the initial setting. Do not touch the unit until the power turns off automatically.
3.1 Setting On Your Smart Device
1 Turn on the Bluetooth of your smart device
2 Download and install the "OMRON connect" app onto your
smart device
You can choose one of the following 2 methods.
■
Scan the code image to get access to the following address.
www.omronconnect.com/setup
■
Search the "OMRON connect" app from "App Store" or "Google Play".
3 Open the app on your smart device and follow set-up and
pairing instructions
If you already have the OMRON connect app, go to: Menu>Device>Add Device
NOTES
• One smart device manages the data of one user.
• If an app other than "OMRON connect" is used, data might not be transferred correctly.
• Please read the utilization method and usage instruction within the app for details.
• The date and time will be automatically set when paired with your smart device.
3.2 Setting On The Unit
For users who have not made initial setting through smart device, please follow the following steps
to do it through the unit.
1 With the panel unit inside the main unit,
Press power switch to turn on the power

8
2 Setting the date and time
1Press the button to select the year
• Setting range of year: 2017 to 2045.
2Press the button to confirm the year, then the month
will blink. Repeat the same steps to select and confirm the
month, day, hour, and minute.
•Time is 24-hour system.
•After all the settings for the year, month, day, hour and minute are
displayed in that sequence, " " blinks, then the power turns off
automatically.
NOTES
• " " blinks when the unit implements the "0 kg correction" automatically. Do not touch the unit until the power
turns off automatically.
• If any mistake is made during the setting, press power switch to turn off the power and start from "Step 1" again.
• If no operation for 3 minutes during setting, the power will turn off automatically. Please start from "Step 1" again.
• To modify the date or time, remove the batteries and wait for at least 20 seconds. Then insert the batteries and
reset again.
Year
Month
Day
Hour
Minute

9
Before using the unit
4. Registering the Personal Data
For the measurement of body composition, it is necessary to register your personal data (birth date,
gender, height). The registered data can be stored for up to 4 users.
The personal data can be registered from "OMRON connect" app as well.
(P7)
Steps for changing/deleting personal data
(P23)
1 With the panel unit inside the main unit,
Press power switch to turn on the power
•After the display of current date, it will display "0.0 kg",
"" and " " will blink.
2 Select and confirm your personal number
•Press the button to select your desired personal number (~).
•Your desired personal number blinks, Birth date ()is displayed,
press the button to confirm.
3 Set the date of birth
•Press the button to set the date birth and press
the button to confirm.
•Setting range of year: 1900 to 2045.
Year
Month
Day

10
4 Set the gender
•Press the button to set the gender (MALE) or (FEMALE)
and press the button to confirm.
5 Set the height
•Press the button to adjust the height and press
the button to confirm.
•After setting "Height", the set "Date of Birth, Age and Height"
is displayed, "0.0 kg" appears.
6 After "0.0 kg" is displayed,
Take out the panel unit and start measurement
•The data of body weight and body composition are recorded in the unit to support automatic recognition.
(P13)
Please confirm the measurement method is
correct before starting measurement ( P11)
90°
7 After the measurement results are displayed,
Step off the main unit
•The personal data registration is completed.
8 Press power switch to turn off the power
•To add new personal data, start from the "Step 1".

11
Before using the unit
5. How to Take a Measurement Accurately
5.1 Correct postures during the measurement
90°
Take a measurement on a
hard and level floor
A cushioned floor surface, such
as a mat or carpet, may result in
an inaccurate measurement.
If you stand on the main unit
with socks on, you will not get
correct measurement results.
Set both feet on the foot
electrodes.
Step onto the main unit barefoot.
Place the arches of your feet onto the
center of the main unit.
Holding method of grip electrodes
Postures to Avoid During Measurement
Hold the inner grip electrodes
firmly with your thumb and
index finger.
Hold the outer grip electrodes
with your ring finger and little
finger.
Press your palms firmly
on the grip electrodes.
Place your index finger in the
dent at the back of the grip
electrodes.
Body shaking Arm bent Arm too low
(or arm too high)
Panel unit
facing upward
Knees bent
Your feet are not
correctly positioned
on the electrodes
The arms are horizontally
raised, and the elbows
are extended straight.
Stand with your
knees and back
straight
Extend your arms
straight at a 90° angle
to your body.

12
5.2 Recommended measurement time period and users
Suitable period for measuring:
After getting up and 2 hours after taking food
Get up
Breakfast
Lunch
Shower, supper
Sleep
Recommended period
Recommended period
Recommended period
Recommended period
After getting up Above 2 hours after taking food
Daily activity within 1 day
2 hours
2 hours
2 hours
For users under 10 years old, the unit displays weight and BMI only.
Incorrect measurement might occur to the following users. Because the body composition such as
body water might greatly deviate from the average value.
Elderly people (over 81 years old) / People with a fever / Body builders or highly trained athletes /
Patients undergoing dialysis / Patients with osteoporosis who have very low bone density / Pregnant
women / People with swelling.
5.3 About the "0 kg correction" (Caution for storing)
If the unit is placed as shown below and the recalibration function does not work, implement the "0
kg correction" before taking the measurement.
The unit is leaning
against the the wall or
other objects
The unit is placed
upside down
The unit is placed
on an object
An object is placed
on the unit
5.4 How to implement the "0 kg correction"
1Place the unit on a hard and level floor
2Press power switch to turn on the power
3
After "0.0 kg" is displayed, with the unit still on the floor, press power switch to turn off the power
•This completes the "0 kg correction". Wait for 5 seconds, and then take a measurement.

13
Operating instructions
6. Measuring Weight and Body Composition
If you use the automatic recognition for measurement, please register the Personal Data.
(P7, P9)
1 With the panel unit inside the main unit,
Press power switch to turn on the power
•After the display of current date, it will display "0.0 kg",
"" and " " will blink.
2 After "0.0 kg" is displayed,
Take out the panel unit
3 Taking a Measurement
1Step on the main unit, extend your arms forward at 90° angle to your body
Please confirm the measurement method is
correct before starting measurement ( P11)
90°
During the measurement of
body composition,
the on-going
conditions will be displayed
t
hrough the movement of .
Blinks three times to show that
weight has been determined.
•Then measure body composition.
Keep staying on foot electrodes.

14
2After the measurement results are displayed, step off the main unit.
4 Check your Personal Number
•This product will infer the personal number automatically from weight and body composition. However,
when users of similar body type and body weight are measured, wrong personal number may be displayed.
If your personal number
is correct…
If your personal number
is incorrect…
Press the button to confirm your
personal number.
Inferred personal number
Once your
personal
number is
confirmed,
and "BirthDate"
disappears.
1. Press the button to select
your personal number.
Inferred personal
number
Your personal
number
2. Press the button to confirm
your personal number.
• Before confirming your personal number, you can switch it to a measurement result you want to view with
the or button.
•If you confirmed your personal number incorrectly, press the button so that you can select your
personal number again.
■If "no. 1" to "no. 4" blinks on the display, or "GUEST" is displayed,
your personal data has not been registered in the unit.
•
Press the button to select your desired personal number (~ ),
press the button to confirm, register your personal data. ( P7, P9)
Weight
Body Fat Percentage

15
5 Check the Measurement Results
•The results display rotates automatically as shown below.
•Once you confirm your personal number, you can switch it to a measurement result you want to view with
the button.
•Use Body Fat Percentage, Subcutaneous Fat Percentage,Skeletal Muscle Percentage, Visceral
Fat Level, and BMI classification indicator as a guide to measurement.
•To better understand your measurement results, refer to the information and diagrams in Section
17 and 18.
•You can switch it to a segmental measurement result you want to view with the button.
•Display the segmental subcutaneous fat percentage and skeletal muscle percentage.
SUBCUTANEOUS FAT
PERCENTAGE
Subcutaneous
Fat Percentage
Classification SKELETAL MUSCLE
PERCENTAGE
Skeletal Muscle Percentage
Classification
BODY AGE
BMI
BMI Classification
VISCERAL
FAT LEVEL
RESTING
METABOLISM
Visceral Fat Level
Classification
WEIGHT
BODY FAT
PERCENTAGE
Body Fat Percentage
Classification
SUBCUTANEOUS
FAT PERCENTAGE
Subcutaneous Fat
Percentage Classification
SKELETAL MUSCLE
PERCENTAGE
Skeletal Muscle
Percentage Classification
Whole Body Arms
Legs Tr unk

16
5 Check the Measurement Results
•The results display rotates automatically as shown below.
•Once you confirm your personal number, you can switch it to a measurement result you want to view with
the button.
•Use Body Fat Percentage, Subcutaneous Fat Percentage,Skeletal Muscle Percentage, Visceral
Fat Level, and BMI classification indicator as a guide to measurement.
•To better understand your measurement results, refer to the information and diagrams in Section
17 and 18.
•You can switch it to a segmental measurement result you want to view with the button.
•Display the segmental subcutaneous fat percentage and skeletal muscle percentage.
SUBCUTANEOUS FAT
PERCENTAGE
Subcutaneous
Fat Percentage
Classification SKELETAL MUSCLE
PERCENTAGE
Skeletal Muscle Percentage
Classification
BODY AGE
BMI
BMI Classification
VISCERAL
FAT LEVEL
RESTING
METABOLISM
Visceral Fat Level
Classification
WEIGHT
BODY FAT
PERCENTAGE
Body Fat Percentage
Classification
SUBCUTANEOUS
FAT PERCENTAGE
Subcutaneous Fat
Percentage Classification
SKELETAL MUSCLE
PERCENTAGE
Skeletal Muscle
Percentage Classification
Whole Body Arms
Legs Tr unk
6 Press the power switch to turn off the power
•Please insert the panel unit into the main unit.(P25)
•The power turns off if the unit is not used for 3 minutes.

17
Using the Memory Function
7. Viewing the Measurement Results on the unit
This unit automatically stores up to 30 measurement results per user.
1 With the panel unit inside the main unit,
Press power switch to turn on the power
•
After the display of current date, it will display "0.0 kg",
" " and " " will blink.
2 Select the personal number
•Press the button to select the personal number you want to view (~).
3 Press the button to confirm the personal number
•"0.0 kg" is displayed.
4 Press the button to view the latest
measurement results
5 Press the button to view previous
measurement results
6 Press the button or the button to check other
measurement results
•Please refer to step 5 of section 6. (P15)
7 Press the power switch to turn off the power
•The power turns off if the unit is not used for 3 minutes.
NOTES
•If the memory is full, new results will replace the old results.

18
Using the Memory Function
8.
View the Measurement Results on Your Smart Device
Follow the instructions from the "OMRON connect" app to view your measurement results.
Then you can confirm the variation of your weight and body composition parameters on your smart
device.
Note
•The "OMRON connect" app must be installed on your smart device. (P7)

19
When necessary
9. Selecting Your Personal Number and Taking a
Measurement
If your personal number is not recognized frequently, you can select your personal number and take
the measurement as follows.
1 With the panel unit inside the main unit,
Press power switch to turn on the power
•
After the display of current date, it will display "0.0 kg",
" " and " " will blink.
2 Select your personal number
Press the button to select your personal number (~).
When "BirthDate ()" is displayed,
•Your personal data has not been registered
in your personal number.
•Register your personal data. (P7, P9)
3 Press the button to confirm the personal number
•"0.0 kg" is displayed.
4 After "0.0 kg" is displayed,
Take out the panel unit
5 Taking a Measurement
•Please refer to step 3 of section 6.
Please confirm the measurement method is
correct before starting measurement ( P11)
90°
6 After Checking the Measurement Results,
Press the power switch to turn off the power
•Please insert the panel unit into the main unit. (P25)
•The power turns off if the unit is not used for 3 minutes.
Table of contents
Other Omron Measuring Instrument manuals

Omron
Omron K3MA-J Series User manual

Omron
Omron K6CM series User guide

Omron
Omron K6CM series User manual

Omron
Omron HEM-CS24 User manual

Omron
Omron K3MA-J Series User manual

Omron
Omron H7CX-R11-N User manual

Omron
Omron H7CC-A Series User manual

Omron
Omron H7CX - User manual

Omron
Omron K6PM-TH User manual

Omron
Omron K35-2 User manual

Omron
Omron Z300 User manual

Omron
Omron K3NC User manual

Omron
Omron KE1 User manual

Omron
Omron G9SX Series User manual

Omron
Omron H7E User manual

Omron
Omron STC-FDR-SW01 User manual

Omron
Omron EQUO Series User manual

Omron
Omron K3GN User manual

Omron
Omron K3NX User manual

Omron
Omron Z300 V3 - SETUP User guide