Red or green display color available.
Wide range of scaling settings, including negative
scaling.
Simple average and movement average proces-
sing methods allow 4 s max. to display the process
value, thus reducing display blinking and making it
easier to read the display.
Step display setting adjusts the step of the
displayed rightmost digit to 2, or 5.
It is possible to fix the displayed rightmost digit to 0.
Zero limit setting enables the K3TJ to display zero
for any value less than the set value and is ideal for
water depth display.
Display brightness can be adjusted.
Conforms to the EMC standard EN61010-1
(IEC1010-1).
uC
Ordering Information
DC Voltage Input Model
Voltage measurement range Display color Supply voltage
g
g
p
y
100 to 240 VAC 24 VDC (internally insulated)
1to5VDC,0to5VDC,and0to
1
0
V
D
C
(
l
t
i
)
Red K3TJ-V111R K3TJ-V116R
,
,
10 VDC (multi-range) Green K3TJ-V111G K3TJ-V116G
DC Current Input Model
Current measurement range Display color Supply voltage
g
p
y
100 to 240 VAC 24 VDC (internally insulated)
4- to 20-mA DC Red K3TJ-A111R K3TJ-A116R
Green K3TJ-A111G K3TJ-A116G
Model Number Legend
K3TJ-jjjjj
12345
1, 2. Input Code
V1: DC voltage input
1 to 5 VDC, 0 to 5 VDC, and 0 to 10 VDC (multi-range)
A1: DC current input
4to20mA
3. Series No.
1: Present series
4. Supply Voltage
1: 100 to 240 VAC
6: 24 VDC (internally insulated)
5. Display Color
R: Red LED
G: Green LED (available upon request)

K3TJ K3TJ
5
Accessories (Order Separately)
Name Appearance Model Applicable Unit
Water-resistive Soft Front Cover K32-L49SC K3TE
K3TF
K3TL
K3TJ
Terminal Cover K32-L49TC K3TF
K3TL
K3TJ
Note: 1. Use the Mounting Adapters provided with the K3TJ to mount the above accessories.
2. The Terminal Cover is used to protect against electric shock but is not waterproof.
Specifications
Ratings
Supply voltage 100 to 240 VAC (50/60 Hz); 24 VDC (internally insulated)
Operating voltage range --15% to 10% of supply voltage
Power consumption Approx. 7.7 VA (max. AC load); approx. 2.8 W (max. DC load)
Insulation resistance 10 M!min. (at 500 VDC) between external terminals and case
Dielectric strength 2.000 VAC for 1 minute between input terminals and power supply
2,000 VAC for 1 minute between external terminals and case
Noise immunity AC Model: "1,500 V on power supply terminals in normal or common mode
DC Model: "480 V on power supply terminals in normal mode and "1,500 V on power supply
terminals in common mode
Vibration resistance Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 minutes each in X, Y, and Z
directions
Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Malfunction: 98 m/s2(10G) for 3 times each in 6 directions.
Destruction: 294 m/s2(30G) for 3 times each in 6 directions
Ambient temperature Operating: --10#Cto55
#C (with no icing)
Storage: --20#Cto65
#C (with no icing)
Ambient humidity Operating: 35% to 85% (with no condensation)
Ambient atmosphere Must be free of corrosive gas
Weight 200 g
Case material Heat-resistive ABS/PC
EMC Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air dischanrge (level 3)
Immunity RF-interference: ENV50140: 10 V/m (amplitude modulated, 80 MHz to
1GHz)(level3)
10 V/m (pulse modulated, 900 MHz)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level4)
Approved standards UL (File No. E4151), CSA (File No. LR67027)
Conforms to EN50081-2 and EN50082-2
Note: An initial current of approximately 0.25 A will flow for approximately 35 ms the moment the K3TJ is turned on.

K3TJ K3TJ
6
Characteristics
Input signal DC voltage/current (4 to 20 mA, 1 to 5 V, 0 to 5 V, and 0 to 10 V)
A/D conversion method Double integral method
Sampling time 0.5 s
Display refresh period 0.5 s
Process value averaging method Simple average/movement average
No. of process value averaging
operation 1, 2, 4, or 8 times
Max. displayed digits 4 digits (--1,999 to +9,999)
Display 7-segment red or green LED with a character height of 14.2 mm
Decimal display Selected by the Up and Down Keys and parameter selector
Scaling function Shift/Scaling adjustment is possible with the Up and Down Keys and parameter selector
Scaling range --1,999 to +9,999
Zero-limit range 0to99digits
Overflow display Flashes
Zero-suppress function Available
External control Process value hold (by short-circuiting the rear terminals)
Enclosure rating Front panel: IP51 (see note)
Case: IP20 Refer to IEC
Terminals: IP00
Memory protection Non-volatile memory (no backup battery is required)
Note: IP51 is ensured with the Water-resistive Soft Front Cover, which can be ordered separately. Without the Water-resistive Soft Front
Cover, the front panel meets the requirements of IP50 instead.
Measuring Ranges
Measuring range Input impedance Reliability Max. permissible continuous load
Voltage (DC) 1to5VDC 1M
!"0.1%rdg "1 digit "250 V
g
(
)
0to5VDC 1M
!"0.1%rdg "1 digit "250 V
0to10VDC 1M
!"0.1%rdg "1 digit "250 V
Current (DC) 4to20mADC 100 !"0.1%rdg "1 digit "50 mA
Note: The measurement accuracy values stated in the above table are guaranteed at an ambient temperature of 255#C.
Parameter List
Parameter name Operation Setting method
Display shift By setting a shift value, the displayed value will be shifted and displayed. Set with the
i
t
l
Scaling value By setting a scaling value, the input signal will be converted and displayed.
Negative value scaling is possible. internal
parameter
s
e
l
e
c
t
o
r
a
n
d
k
e
y
Decimal point The decimal point position can be selected. se
l
ec
t
or an
d
k
ey
input.
Average display Displays the process value for 4 s maximum after a simple average or movement
average process.
i
n
p
u
t
.
Zero-limit range input Zero will be displayed for any value below the zero-limit value.
2-digit step display Rounds the rightmost digit to 0, 2, 4, 6, or 8.
5-digit step display Rounds the rightmost digit to 0 or 5.
Rightmost digit at 0 Rounds the rightmost digit to 0.
Display brightness adjustment Adjusts the brightness of the display to one of three levels.

K3TJ K3TJ
7
Nomenclature
PV display Unit of measure
Unit Label (Provided)
Select the applicable unit label from the unit label sheet provided with the K3TJ and attach it to the bottom-right side of the display.
Operation
Removal of Front Panel
Insert a flat-blade screwdriver into the groove on the bottom of the front panel and pull the front panel off.
The following is seen after the front panel is removed.
Parameter
selector
Up Key
Down
Key
1 3456782
ON
No. Name Parameter
1Parameter
selector When any one of parameter selector
pins 1 to 8 is set to ON, the
corresponding setting item can be
changed.
2, 3 Up Key, Down
Key TheUpandDownKeysareusedto
change the set value when the
corresponding parameter selector
pin is set to ON.

K3TJ K3TJ
8
Parameter Selection
WhenaparameterselectorpinissettoOFF,thecorrespondingsetvaluethathasbeenchangedwillbestoredinthenon-volatilememory.Any
datathathasbeenpreviouslysetwillbekept inthenon-volatilememoryregardlessofwhethertheK3TJisturnedonoroff.Thefollowingtable
lists the parameters assigned to parameter selector pins 1 to 8.
13456782
ON
OFF ON Pin no. Setting
1Input range
2Display shift
3Scaling
4Decimal point
5Averaging
6Zero limit
7Step display
8Display brightness
Parameter Setting
The K3TJ is factory-set to display 0 when the minimum input range value is input and display 1,000 when the maximum input range value is
input.
DC Voltage Input Model
Input range Display
0- to 5-VDC input 0to 1000
1- to 5-VDC input
0
t
o
1
0
0
0
0- to 10-VDC input
DC Current Input Model
Input range Display
4 to 20 mA DC input 0to 1000
1000
0max.min.
Display
Input
Adjust the display shift and scaling for the K3TJ
while applying an actual input.
1. Input Range Setting
Select the 0- to 5-V, 1- to 5-V, or 0- to 10-V input range on the DC Voltage Input Model and 4- to 20-mA input range on the DC Current Input
Model.
Example: When selecting the 1- to 5-V input range on the DC Voltage Input Model
Use the Up or Down Keys so that 1- 5 will be displayed.
Up Key or
Down Key
0- 10
1
3
4
5
6
7
8
2
1
3
4
5
6
7
8
2
OFF ON
OFF ON
1- 5
Set parameter selector pin 1 to ON, at which time the
factory-set input range 0- 10 will be displayed.
When 1- 5 is displayed, set parameter selector pin 1 to
OFF to complete the input range setting.
The input range has been changed to
the 1 to 5 V range.
DC Voltage Input Model
Display Input range
0- 5 0to5VDC
1- 5 1to5VDC
0-10 0to10VDC(factory-set)
DC Current Input Model
Display Input range
4-20 4to20mADC

K3TJ K3TJ
9
2. Display Shift Adjustment
The display can be shifted within a range of --1,999 to 9,999.
Adjust the display shift while applying an actual input.
Display after shifting
4mAor1V
4- to 20-mA or 1- to 5-V range
Display after shifting
Input Input
0- to 5-V or 0- to 10-V range
1000
1000 + b
1000 + b
1000
b
0
b
0
Example: When shifting from 10 to 0
Use the Up or Down Key to change the display. To
change the value to 0, use the Down Key. The displayed
value will increase automatically if the Up Key is pressed
for 1 s or more and will decrease automatically if the
DownKeyispressedfor1sormore.
Up Key or
Down Key
10
1
3
4
5
6
7
8
2
OFF ON
0
Set parameter selector pin 2 to ON, at which time the
displaywillnotchangebutadisplayshiftadjustmentwill
be possible.
After 0is displayed, set parameter selector pin 2 to OFF
to complete the display shift adjustment.
The display will be shifted
by --10.
1
3
4
5
6
7
8
2
OFF ON
Display
Shift adjustment
Input
0
10

K3TJ K3TJ
10
3. Scaling Adjustment
TheK3TJis factory-set todisplay 0to 1,000 for the minimumandmaximum input range value.By settingthescaling,theK3TJ can be scaled
within a range of 0 to 9,999 or 0 to --1,999.
Display after scaling
Input
4mAor1V
4- to 20-mA or 1- to 5-V range
Display after scaling
Input
0- to 5-V or 0- to 10-V range
1000
1000 x a
1000 x a
1000
00
Example: When adjusting the factory set value 800 to a scaling value of 1200
Adjust the scaling while applying an actual input.
Use the Up or Down Key to change the display. To
change the value to 1200, use the Up Key. The displayed
value will increase automatically if the Up Key is pressed
for 1 s or more and will decrease automatically if the
DownKeyispressedfor1sormore.
Up Key or
Down Key
800
1
3
4
5
6
7
8
2
OFF ON
1200
Set parameter selector pin 3 to ON, at which time the
display will not change but ascaling adjustment will be
possible.
After 1200 is displayed, set parameter selector pin 3 to
OFF to complete the scaling adjustment
The scaling has been changed.
1
3
4
5
6
7
8
2
OFF ON
Display
Scaling
adjustment
Input
1200
800
0
Display Shift Setting and Scaling Operation
In the following example, 4 to 20 mA is scaled to be 100 to 1,000.
Display
Factory set
Shift ad-
justment
4 mA is input Input
Display
Span adjustment
Input
20 mA is input
0
100
1000
1100
20 mA 0
100
1000
1100
4mA
1. Shift Adjustment 2. Scaling Adjustment
Note: 1. At the time of scaling adjustment, the starting point for changing the inclination of the straight line will be the minimum value of the
input range. Therefore, when using only a part of the input range, repeat shifting and scaling adjustments several times.
2. TurntheK3TJoffandonwhilepressingboththeUpandDownKeyssothattheK3TJ’sshiftingandscalingsettingswillreturntothe
ones preset before shipping.

K3TJ K3TJ
11
4. Decimal Point Setting
The decimal is set to the desired position.
Use the Up or Down Key to change the
decimal point position.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF ON
Setparameterselectorpin4toONtoset
the decimal.
After changing the decimal point, set
parameter selector pin 4 to OFF to
complete the new decimal point set-
ting.
1
3
4
5
6
7
8
2
OFF ON Display Decimal point
0000 No decimal point (factory-set)
000.0 Next to 101digit on the left
00.00 Next to 102digit on the left
0.000 Next to 103digit on the left
Note: In thecase ofa rangeof --0.001to --0.999, -.001to-.999 will
be displayed.
5. Average Process Setting
There are two ways to input signals: the simple average processing method and the movement average processing method.
Inthesimpleaverageprocessingmethod,themeanvalueisdisplayedaftersamplingntimes.Thismethodiseffectivewhentheuserrequiresa
long display refresh period.
Inmovementaverageprocessingmethod,thesamplingdataobtainedfromsamplingntimesincludingthepresentsamplingoperationisaver-
aged and displayed. This method is effective for removing the periodical noise overlapped with the input signals.
Use the Up or Down Key to change the
average processing method.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF ON
Setparameterselectorpin5toONtoset
the average processing.
Afterselectingtheaverageprocessing
method,setparameterselectorpin5to
OFF to complete the average process
setting.
1
3
4
5
6
7
8
2
OFF ON Display Average processing
1No average processing is possible (factory set)
a- 2 Simple average processing by sampling twice
a- 4 Simple average processing by sampling four times
a- 8 Simple average processing by sampling eight
times
b- 2 Movement average processing by sampling twice
b- 4 Movement average processing by sampling four
times
b- 8 Movement average processing by sampling eight
times

K3TJ K3TJ
12
6. Zero Limit Setting
Zero limit setting enables the K3TJ to display zero for any value less than the set value. This is effective if the user needs to have the K3TJ
displayzeroinsteadofanegativevalueortheuserneedstohavetheK3TJdisplayzerofortheminimuminputrangevalue.Thesettingrangeis
from 00 to 99. When no zero limit is set, off will be displayed.
Use the Up or Down Key to input the
zero limit value. The displayed value
will increase automatically if the Up Key
is pressed for 1 s or more and will de-
crease automatically if the Down Key is
pressed for 1 s or more.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF ON
Setparameterselectorpin6toONtoset
the zero limit.
Aftersettingthezerolimit, set parame-
ter selector pin 6 to OFF to complete
the zero limit setting.
1
3
4
5
6
7
8
2
OFF ON Display Zero limit setting
99 to
00 Zero limit setting range
off No zero limit (factory set)
Zero Limit Setting Range
Display
Zero limit
setting
value Input
7. Step Display Setting
Step display setting is usedto changethe step of thedisplayed rightmost digit changes. This setting is effective if the input signal repeatedly
displays 999 and 1000 and is difficult to read. The following table shows the step display patterns.
Use the Up or Down Key to select the
display pattern.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF ON
Setparameterselectorpin7toON toset
thestepdisplay.
After selecting the display pattern, set
parameter selector pin 7 to OFF to
complete the step display setting.
1
3
4
5
6
7
8
2
OFF ON Display Step display pattern
1No step display (factory set)
2With every two digits
5With every five digits
10 With every ten digits (the rightmost digit is fixed to
0)
Step Display Parameter
The display step of the rightmost digit can be selected.
1 2 3 4 5 6 7 8 9 10 11 12 13 140
0
2 4 6 8 10 12 14
51015
010
Input value
2-digit step
5-digit step
Fixedtobezero
Displayed
value
0

K3TJ K3TJ
13
8. Display Brightness Adjustment
It is possible to change the display brightness in three steps.
Use the Up or Down Key to select the
proper display brightness.
Up Key or
Down Key
1
3
4
5
6
7
8
2
OFF ON
Set parameter selector pin 8 to ON, at
which time the display will not change
but a display brightness adjustment will
be possible.
After the display brightness has been
selected, set parameter pin 8 to com-
plete the display brightness setting.
1
3
4
5
6
7
8
2
OFF ON
Error Message
Refer to the following table in the case of an error.
Display Cause Remedy
e01 The internal memory has malfunctioned. Turn the K3TJ OFF and ON. If the error condition of the
K
3
T
J
d
o
e
s
n
o
t
c
h
a
n
g
e
c
o
n
s
u
l
t
y
o
u
r
O
M
R
O
N
r
e
p
r
e
s
e
n
t
a
t
i
v
e
e02 The non-volatile memory has malfunctioned. K3TJ does not change, consult your OMRON representative.
e03 The calibration value stored in the non-volatile memory has
been corrupted.
e10 The input range set value stored in the non-volatile memory
has been corrupted. Select the input range again according to the input range
setting procedure.
e11 The shift value stored in the non-volatile memory has been
corrupted. Execute display shift again according to the display shift
adjustment procedure.
e12 The scaling value stored in the non-volatile memory has
been corrupted. Execute scaling again according to the scaling adjustment
procedure.
e13 The decimal point set value stored in the non-volatile
memory has been corrupted. Set the decimal point again according to the decimal point
setting procedure.
e14 The average processing set value stored in the non-volatile
memory has been corrupted. Select average processing again according to the average
processing setting procedure.
e15 The zero limit value stored in the non-volatile memory has
been corrupted. Set the zero limit value again according to the zero limit
value setting procedure.
e16 The step value stored in the non-volatile memory has been
corrupted. Set the step display pattern again according to the step
display setting procedure.
e17 The brightness setting value in the non-volatile memory has
been corrupted. Set the display brightness again according to the display
brightness adjustment procedure.
Note: TurntheK3TJOFFandONwhilepressingboththeUpandDownKeyssothattheK3TJ’sshiftingandscalingsettingswillreturntothe
ones preset before shipping.

K3TJ K3TJ
14
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Panel Cutouts
75 min.
120 min.
LED Display Character Size
14.2 mm
7.8 mm
45+0.6
-- 0
92+0.8
-- 0
66
98
92
96
48
3.5
45
Installation
External Connections
24 VDC
HOLD GND
GND0to10VDC
0to5VDC
1to5VDC
4to20mADC
INPUT POWER
321 4 5 6 7 8 9
100to240VAC
Note: Terminals 3 and 6 are connected internally. The power supply terminals are insulated from other circuits.
Connection Example with Inverter
+
--
E
0to10VDC 1
GND
3
3G3jV8888
Analog
monitor
Analog output
K3TJ
R
S
T
R
S
T
U
V
WIM
Three-phase
power supply
Circuit breaker Inverter ’s
internal
circuitry

K3TJ K3TJ
15
Precautions
Mounting
Recommended panel thickness is 1 to 3.2 mm.
Mount the K3TJ by attaching the mounting bracket supplied as an
accessory from the rear of the K3TJ. Turn each mounting screw
clockwise and tighten it to a torque of 5 kgf $cm (0.49N $m).
Mount the K3TJ as horizontally as possible.
Never use the K3TJ in locations where corrosive gas (particularly
sulfuric or ammonia gas) exists.
AvoiduseoftheK3TJ in locations subjectto severeshock orvibra-
tion, excessive dust, or excessive moisture.
Select mounting locations where the ambient operating tempera-
ture is --10#Cto55
#C.
Others
Whenselectingparametersormakingsettings,thefrontpanelcov-
ershouldberemoved.Donot touchpartsotherthanthe DIP switch
andkeyswithyourhandorametalobject,especiallywhentheK3TJ
is turned ON.

K3TJ K3TJ
16
OMRON Corporation
Systems Components Division
28th Fl., Crystal Tower Bldg.
1-2-27, Shiromi, Chuo-ku,
Osaka 540 Japan
Phone: 06-949-6012 Fax: 06-949-6021
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. N080-E1-1C In the interest of product improvement, specifications are subject to change without notice.
Printed in Japan
1096-0.5M (0694) a
Table of contents
Other Omron Measuring Instrument manuals

Omron
Omron Z300 User manual

Omron
Omron K7GE-MG User manual

Omron
Omron H7CX - User manual

Omron
Omron Peak-Air PF9940 User manual

Omron
Omron K3NC User manual

Omron
Omron M22 User manual

Omron
Omron K3MA-J Series User manual

Omron
Omron K7DD User manual

Omron
Omron K3HB-C Series User manual

Omron
Omron ZN-KMX21 Series User manual

Omron
Omron ZX-GT - User manual

Omron
Omron Sysmac NA Series Instructions for use

Omron
Omron Sti G9SX-SM032 Series User manual

Omron
Omron Z300 V3 - SETUP User guide

Omron
Omron Supergate 8615 User manual

Omron
Omron EQUO Series User manual

Omron
Omron STC-FDR-SW01 User manual

Omron
Omron G9SX-LM User manual

Omron
Omron K3GN - V1.04 User manual

Omron
Omron K3HB-P User manual