A-220 Standard Photoelectric Sensors
Sensors
Amplifier Units
Note: 1.Analog output outputs up to approximately 6 V (24 mA). Outputs 1 V (4 mA) when there is no incoming light.
2.F.S. stands for full scale. For a current output, full scale is 16 mA (4 to 20 mA).
Voltage output: 4 V (1 to 5 V)
3.Definition of the luminous energy integral: The physical unit of the luminous energy integral is energy (J: joules) and this value is calculated by multiplying the
UV intensity (mV) by the time of exposure (s), but it is dimensionless when this sensor's analog output value (V) is used for the UV intensity. The integral is
measured with an 11 ms sampling time.
Optical Fiber Type
Item Model F3UV-XW11*1
*1. A model with 5 times the sensitivity is also available.
F3UV-XW41 F3UV-XA
Power supply voltage 12 to 24 VDC ±10%
Current consumption 75 mA max. 15 mA max.
Out-
put
Analog output Current (4 to 20 mA)/Voltage (1 to 5 V) (when using light intensity monitor
and light intensity integration mode)
Voltage (1 to 5 V) (offset voltage of
0.2 V or less)
Discrimination
output
NPN open collector output, 100 mA
or less, residual voltage 1 V or less
(when using light intensity monitor
and light intensity integration
mode)
PNP open collector output, 100 mA
or less, residual voltage 2 V or less
(when using light intensity monitor
and light intensity integration
mode)
---
Answer-back
output
NPN open collector output, 100 mA
or less, residual voltage 1 V or less
(when using light intensity monitor
and light intensity integration
mode)
PNP open collector output, 100 mA
or less, residual voltage 2 V or less
(when using light intensity monitor
and light intensity integration
mode)
---
In-
puts
Remote
teaching input
When ON: 0 V short circuit (short
circuit current of 1 mA or less)
When OFF: Open circuit (open or 9
V or higher and 24 V or less)
When ON: Power supply voltage
short circuit or 9 V or higher and
24 V or less (short circuit current
of 3 mA or less)
When OFF: Open circuit (open or
1.5 V or less)
---
Reset input
When ON: 0 V short circuit (short
circuit current of 1 mA or less)
When OFF: Open circuit (open or
9 V or higher and 24 V or less)
When ON: Power supply voltage
short circuit or 9 V or higher and
24 V or less (short circuit current of
3 mA or less)
When OFF: Open circuit (open or
1.5 V or less)
---
Protective circuits Protection from load short-circuit and reversed power supply connection
Response time*2
*2. Response time: 10% to 90% of rise and fall time of analog output signal.
500 ms max. 300 ms max.
Sensitivity setting Teaching 8-revolution dial type
Indicator lamp
Measurement/teaching indicator lamp (green/red) Operation indicator
lamp (orange) 7 segment digital percent display (red) 7 segment digital
threshold value display (red)
Power display (green) Operation
display (orange)
Repetition precision ±2% F.S. max.
Ambient illuminance Fluorescent light 1,000 lx max.*3
*3. An analog output of up to 6 V (or 24 mA) can be output. The output is 1 V (or 4 mA) when there is no incident UV light.
Fluorescent light 1,000 lx max.*4
*4. Shows value at which offset voltage can maintain 1 V or less using fluorescent lamp.
Temperature drift ±0.1% of F.S./°C max 0.2% of F.S./°C max.
Ambient temperature Operating: -25 to +55°C, Storage: -40 to +70°C (with no icing or condensation)
Ambient humidity Operating/storage: 35% to 85% RH
Insulation resistance 20 M min. at 500 VDC
Dielectric strength Lead wires to case: 1,000 V AC 50/60 Hz
Vibration resistance 10 to 150 Hz, half amplitude of 0.1 mm, or 15 m/s2, 2h each in X, Y, and Z directions
Shock resistance 150 m/s2, 3 times each in X, Y, and Z directions
Protective structure IEC Standard IP30 IEC 60529 IP50
Connection method Pre-wired models (standard length: 2 m)
Weight (Packed state) Approx. 270 g Approx. 60 g
Material ABS
Accessories Instruction manual Operation manual, adjustment
driver, clamps