manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Omron
  6. •
  7. Measuring Instrument
  8. •
  9. Omron H7E User manual

Omron H7E User manual

Other manuals for H7E

1

This manual suits for next models

3

Other Omron Measuring Instrument manuals

Omron H7CX-N - User manual

Omron

Omron H7CX-N - User manual

Omron V700-HMD11 User manual

Omron

Omron V700-HMD11 User manual

Omron K3HB-P User manual

Omron

Omron K3HB-P User manual

Omron HEM-RML30 User manual

Omron

Omron HEM-RML30 User manual

Omron K3HB-C Series User manual

Omron

Omron K3HB-C Series User manual

Omron Z500 Series User manual

Omron

Omron Z500 Series User manual

Omron KE1 User manual

Omron

Omron KE1 User manual

Omron K3GN User manual

Omron

Omron K3GN User manual

Omron K3NX User manual

Omron

Omron K3NX User manual

Omron K7DD User manual

Omron

Omron K7DD User manual

Omron KM1 User manual

Omron

Omron KM1 User manual

Omron F3UV Series User manual

Omron

Omron F3UV Series User manual

Omron K3MA-L User manual

Omron

Omron K3MA-L User manual

Omron K3MA-J Series User manual

Omron

Omron K3MA-J Series User manual

Omron K7DD User manual

Omron

Omron K7DD User manual

Omron H8PS User manual

Omron

Omron H8PS User manual

Omron K6PM-TH User manual

Omron

Omron K6PM-TH User manual

Omron K3MA-J Series User manual

Omron

Omron K3MA-J Series User manual

Omron H7CC-A Series User manual

Omron

Omron H7CC-A Series User manual

Omron K6PM-TH User guide

Omron

Omron K6PM-TH User guide

Omron K6CM series User guide

Omron

Omron K6CM series User guide

Omron Z500 Series User manual

Omron

Omron Z500 Series User manual

Omron Z300 V3 - SETUP User guide

Omron

Omron Z300 V3 - SETUP User guide

Omron K3MA-L User manual

Omron

Omron K3MA-L User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CSM_H7E_-N_DS_E_9_3
1
Self-powered Totalizer
New H7E
Compact Economical Totalizer with High Visibility
Available with Backlit LCD Display
• Large display with 8.6-mm character height.
• Includes new models with backlight for improved visibility in dimly lit places. (Requires 24-VDC power supply.)
• Black and light-gray cases now available.
• PNP/NPN universal DC voltage input types now available.
• Battery is replaceable for Totalizer reuse and conservation of the environment.
• Key-protect switch to prevent faulty reset key operation.
• Dual operation mode.
• Front face compatible with NEMA4/IP66.
• Short body, all models have a depth of 48.5 mm.
• Finger protection terminal block conforms to VDE0106, Part100.
• Conforms to UL, CSA, and CE marking.
Conforms to EN61010-1 (pollution degree 2/overvoltage category III.)
• Conforms to EMC standards and EN61326, thus allowing use in residential, commercial and light- and heavy-industry environ-
ments.
• Six-language instruction manual provided.
• PCB-mounting models available. (Requires 3-V power supply.)
■Broad Line-up of the New H7E Series
Contents
Self-powered Totalizers
H7EC..................................................................................................................... 2
H7ET ..................................................................................................................... 9
H7ER..................................................................................................................... 16
H7E@-N@P ........................................................................................................... 22
Common to All Totalizers
Accessories........................................................................................................... 27
Precautions ........................................................................................................... 29
New H7E
Total Counter
•8-digit
Time Counter Tachometer
New H7EC New H7ET New H7ER New H7E@-N@P
PCB-mounting Counter
•Total Counter (8-digit)
•Time Counter (999999.9h)
•999999.9h/
3999d23.9h
•999h59min59s/
9999h59.9min
•1,000 s-1 with
1 pulse/rev. encoder
•1,000.0 s-1 with
10 pulse/rev. encoder
•1,000 min-1 with
60 pulse/rev. encoder
•10,000 min-1 with
60 pulse/rev. encoder
•1,000.0 min-1 with
600 pulse/rev. encoder
Downloaded from Arrow.com.
2
Self-powered Total Counter
New H7EC
• Eight-digits, counting range 0 to 99999999.
• Dual input speed: 30 Hz ←→ 1 kHz (except for AC/DC multi-
voltage input models)
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
■Model Number Legend
Note: Some configurations are not available.
Note:
Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details.
Ordering Information
■Total Counters
■Accessories (Order Separately)
Note: 1. Provided with H7EC. (Order additional Brackets separately as required.)
2. Built into H7EC. Order replacements using the above model number before the service life expires.
123
H7EC - N -
1. Count Input
2. Case Color
3. Display
None: No-voltage input
V: PNP/NPNuniversal DC voltage input
FV: AC/DC multi-voltage input
None: Light gray
B: Black
None: 7-segment LCD without backlight
H: 7-segment LCD with backlight
Count input Max. counting speed Display Model
Light-gray body Black body
PNP/NPN universal DC
voltage input
(4.5 to 30 VDC)
30 Hz ←→ 1 kHz
(switchable) 7-segment LCD with
backlight H7EC-NV-H H7EC-NV-BH
7-segment LCD H7EC-NVH7EC-NV-B
AC/DC multi-voltage input
(24 to 240 VAC/VDC) 20 Hz 7-segment LCD H7EC-NFVH7EC-NFV-B
No-voltage 30 Hz ←→ 1 kHz
(switchable) 7-segment LCD H7EC-N H7EC-N-B
Name Model
Compact Flush Mounting Bracket Y92F-35
Flush Mounting Bracket (See note 1) Y92F-34
Wire-wrap Terminal (set of two Terminals) Y92S-37
Lithium Battery (See note 2) Y92S-36
Waterproof Packing (See note 1) Y92S-32
Downloaded from Arrow.com.Downloaded from Arrow.com.
New H7EC
3
Specifications
■General
Note: 1. Separately ordered Wire-wrap Terminals (Y92S-37) are required.
2. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
■Ratings
Note: ON/OFF ratio 1:1
Item H7EC-NV-@
H7EC-NV-@HH7EC-NFV-@H7EC-N-@
Operating mode Up type
Mounting method Flush mounting
External connections Screw terminals, optional Wire-wrap Terminals (see note 1)
Reset External/Manual reset
Number of digits 8
Count input PNP/NPN universal DC voltage in-
put AC/DC multi-voltage input No-voltage input
Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 2)
Max. counting speed 30 Hz/1 kHz 20 Hz 30 Hz/1 kHz
Case color Light gray or black (-B models)
Attachment Waterproof packing, Y92F-34 Flush Mounting Bracket
Approved standard UL863, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III)
Conforms to VDE0106/P100
Item H7EC-NV-@
H7EC-NV-@HH7EC-NFV-@H7EC-N-@
Supply voltage Backlight model: 24 VDC (0.3 W max.)
(only for backlight)
No-backlight model: Not required
(powered by built-in battery)
Not required (powered by built-in battery)
Count input High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC
(Input impedance: Approx. 4.7 kΩ)
High (logic) level: 24 to 240 VAC/VDC,
50/60 Hz
Low (logic) level: 0 to 2.4 VAC/VDC, 50/
60 Hz
No voltage input
Maximum short-circuit impedance:
10 kΩmax.
Short-circuit residualvoltage: 0.5Vmax.
Minimum open impedance: 750 kΩmin.
Reset input No voltage input
Maximum short-circuit impedance:
10 kΩmax.
Short-circuit residualvoltage: 0.5Vmax.
Minimum open impedance: 750 kΩmin.
Max. counting
speed (see note) 30 Hz or 1 KHz
(Switchable with switch) 20 Hz 30 Hz or 1 KHz
(Switchable with switch)
Minimum signal
width 20 Hz: 25 ms
30 Hz: 16.7 ms
1 KHz: 0.5 ms
Reset system External reset and manual reset: Minimum signal width of 20 ms
Terminal screw
tightening torque 0.98 N·m max.
Ambient tempera-
ture Operating: –10°C to 55°C (with no condensation or icing)
Storage: –25°C to 65°C (with no condensation or icing)
Ambient humidity Operating 25% to 85%
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
New H7EC
4
■Characteristics
Note: 1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
2. Weight includes waterproof packing and flush mounting bracket.
■Reference Value
Item H7EC-NV-@
H7EC-NV-@H
H7EC-NFV-@H7EC-N-@
Insulation resistance 100 MΩmin. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts, and between the backlight power
supply terminal and count input termi-
nals/reset terminals for backlight mod-
els
100 MΩmin. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
and between count input terminals and
reset terminals
100 MΩmin. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
and between the backlight power sup-
ply terminal and count input terminals/
reset terminals for backlight models
3,700 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
2,200 VAC, 50/60 Hz for 1 min between
reset terminals and exposed non-cur-
rent-carrying metal parts and between
count input terminals and reset termi-
nals
1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal parts
Impulse withstand
voltage
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
3 kV between input terminals and reset
terminals
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
±600 V (Between count input terminals/
Between reset terminals)
±480 V (Between the backlight power
supply terminals for backlight models)
±1.5 kV (Between count input termi-
nals)
±500 V (Between reset terminals)
±500 V (Between count input terminals/
Between reset terminals)
Static immunity ±8 kV (malfunction)
Vibration resistance Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance Malfunction: 200 m/s23 times each in 6 directions
Destruction: 300 m/s2 3 times each in 6 directions
EMC (EMI) EN61326-1 (See note 1.)
Emission Enclosure: EN55011 Group 1 class B
(EMS) EN61326-1 (See note 1.)
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
EN61000-4-3: 10 V/m (900 MHz ±5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power line (level 3)
2 kV I/O signal line (level 4)
Degree of protection Front panel: IP66, NEMA4
Terminal block: IP20
Weight (see note 2.) No-backlight model: Approx. 60 g
Backlight model: Approx. 65 g
Approx. 60 g Approx. 60 g
Item Value Note
Battery life 7 years min. with continuous input at 25°C
(lithium battery)
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
New H7EC
5
Connections
■Terminal Arrangement
Bottom view: View of the Total Counter rotated horizontally 180°
■Connections
H7EC Total Counter
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are func-
tionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector ≥50 V
Leakage current < 100 µA
Backlight Model No-backlight Model
Backlight
24 VDC
Count
input Reset
input
Count
input Reset
input
PNP/NPN Universal DC Voltage Input Model With Backlight
1. Contact Input (Input by a Relay or Switch Contact) 2. Solid-state Input
Relay
Input Reset
Relay
or Switch or Switch
Input Reset
Backlight
24 VDC
Open collector of a
PNP transistor Open collector of a
PNP transistor
Backlight
24 VDC
or Open collector of an
NPN transistor or Open collector of an
NPN transistor
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
New H7EC
6
No-voltage Input Model
1. Contact Input (Input by a Relay or Switch Contact)
AC/DC Multi-voltage Input Model
PNP/NPN Universal DC Voltage Input Model Without Backlight
1. Contact Input (Input by a Relay or Switch Contact)
2. Solid-state Input
Relay Input Reset Relay
or Switch or Switch
or Switch
Input Reset
Relay
Relay
Input Reset
or Switch or Switch
Relay
Input Reset
Relay
or Switch or Switch
Input Reset
Open collector of a
PNP transistor Open collector of a
PNP transistor
or Open collector of an
NPN transistor or Open collector of an
NPN transistor
Note: 1. Terminals 2 and 4 (input circuit and reset circuit) are
functionally isolated.
2. Select input transistors according to the following:
Dielectric strength of the collector ≥50 V
Leakage current < 100 µA
or Open collector of
an NPN transistor
Note: Select input transistors according to the following:
Dielectric strength of the collector ≥50 V
Leakage current < 1 µA
Terminals 2 and 4 are
internally connected.
Note: Use Relays and Switches that have high contact
reliability because the current flowing from terminals
1 or 3 is small. It is recommended that OMRON's
G3TA-IA/ID be used as the SSR.
2. Solid-state Input
(Open Collector Input of an NPN Transistor)
Open collector of an
NPN transistor Open collector of an
NPN transistor
Terminals 2 and 4 are
internally connected.
Note: 1. Residual voltage in the output section of Proximity
Sensors or Photoelectric Sensors becomes less than
0.5 V because the current flowing from terminals 1 or 3
is small thus allowing easy connection.
2. Select input transistors according to the following:
Dielectric strength of the collector ≥50 V
Leakage current < 1 µA
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
New H7EC
7
Operation
■Operating Modes
Nomenclature
Note: 1. Perform switch setting before mounting to a control panel.
2. If the counting speed setting is changed, the present value will not be held. Press the Reset Key on the front panel.
3. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional.
H7EC Total Counter
Reset
Counting display values
Full-scale
Count input
Incrementing Operation
(Up)
(Full-scale
−1)
H7EC
1 kHz
Front view
Bottom view
Reset Key
Key-protect Switch
Countingspeed switch
Key-protect
Front panel
ON
Terminal block
Countingspeed
Front panel
Terminal block
For all models except for H7EC-NFV-@.
If the counting speed setting is changed,
the present value will not be held and so
press the Reset Key on the front panel.
Setting
(see note)
30 Hz
(default setting)
Setting
(see note)
OFF
(default setting)
Reset the count value. Not operable
under key-protect.
Concave
side
Concave
side
The Reset Key is not operable while the
key-protect switch is set to ON.
Concave
side
Concave
side
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
New H7EC
8
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H7EC-N
Note: A Compact Flush Mounting Bracket (Y92F-35) can also be used. Refer to Accessories for details.
22.2
+0.5
0
45
+0.5
0
22.2
+0.5
0
Panel Cutout
Dimensions with Y92F-34 Flush Mounting Bracket
Separate mounting
Dense mounting
40 min.
(48 Units −2.5)+1.0
0
Waterproofing is not possible for
dense mounting
•When mounting, insert the Counter into
the cutout, insert the adapter from the
back and push in the Counter while
making the gap between the front panel
and the cutout panel as small as
possible. Use screws to secure the
Counter.If waterproofing is desired,
insert the waterproof packing.
•When several Counters are installed,
ensure that the ambient temperature
will not exceed specifications.
•The appropriate thickness of the panel
is 1 to 5 mm.
M3.5 terminal screw
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
9
Self-powered Time Counter
New H7ET
• Seven digits, time range 0 to 3999d23.9h.
• Dual time range: 999999.9 ←→ 3999d23.9h or
999h59m59s ←→ 9999h59.9m
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
■Model Number Legend
Note: Some configurations are not available.
Note:
Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details.
Ordering Information
■Time Counters
■Accessories (Order Separately)
Note: 1. Provided with H7ET. (Order additional Brackets separately as required.)
2. Built into H7ET. Order replacements using the above model number before the service life expires.
12 34
H7ET - N -
1. Count Input
2. Time Range
3. Case Color
4. Display
None: No-voltage input
V: PNP/NPNuniversal DC voltage input
FV: AC/DC multi-voltage input
None: 999999.9h/3999d23.9h
1: 999h59m59s/9999h59.9m
None: Light gray
B: Black
None: 7-segment LCD without backlight
H: 7-segment LCD with backlight
Timer input Display Time range
999999.9h ←→ 3999d23.9h
(switchable) 999h59min59s ←→ 9999h59.9min
(switchable)
Light-gray body Black body Light-gray body Black body
PNP/NPN universal DC volt-
age input
(4.5 to 30 VDC)
7-segment LCD with back-
light H7ET-NV-H H7ET-NV-BH H7ET-NV1-H H7ET-NV1-BH
7-segment LCD H7ET-NVH7ET-NV-B H7ET-NV1H7ET-NV1-B
AC/DC multi-voltage input
(24 to 240 VAC/VDC) 7-segment LCD H7ET-NFVH7ET-NFV-B H7ET-NFV1H7ET-NFV1-B
No-voltage input 7-segment LCD H7ET-N H7ET-N-B H7ET-N1 H7ET-N1-B
Name Model
Compact Flush Mounting Bracket Y92F-35
Flush Mounting Bracket (See note 1) Y92F-34
Wire-wrap Terminal (set of two terminals) Y92S-37
Lithium Battery (See note 2) Y92S-36
Waterproof Packing (See note 1) Y92S-32
Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.Downloaded from Arrow.com.
New H7ET
10
Specifications
■General
Note: 1. Only PNP/NPN universal DC voltage input models (-H models) have a backlight.
2. The frequency range for an AC voltage is 50 to 60 Hz.
3. “-hours”, “-d-h”, “-h-m”, and “-h-m-s” labels are included.
4. Zero suppression: Zeros are not displayed to increase readability. For example, "000008.2" is displayed as "8.2" if zero suppression is
set. If the range is set to 3999d23.9h, the value is "008.2".
■Ratings
Item H7ET-NV-@
H7ET-NV-@HH7ET-NFV-@H7ET-N-@H7ET-NV1-@
H7ET-NV1-@HH7ET-NFV1-@H7ET-N1-@
Operating mode Accumulating
Mounting method Flush mounting
External connections Screw terminals
Reset External/Manual reset
Display 7-segment LCD with or without backlight, zero suppression (character height: 8.6 mm) (see note 1)
Number of digits 7
Time range 0.0h to 999999.9h ←→ 0.0h to 3999d23.9h
(switchable with switch) 0s to 999h59min59s ←→ 0.0min to 9999h59.9min
(switchable with switch)
Timer input PNP/NPN univer-
sal DC voltage in-
put
AC/DC multi-volt-
age input No-voltage input
(see note 2) PNP/NPN univer-
sal DC voltage in-
put
AC/DC multi-volt-
age input No-voltage input
Case color Light gray or black (-B models)
Attachment Waterproof packing, Y92F-34 Flush Mounting Bracket, time unit labels (see note 3)
Approved standard UL863, CSA C22.2 No.14, Lloyds
Conforms to EN61010-1/IEC61010-1 (pollution degree2/overvoltage category III)
Conforms to VDE0106/P100
Item H7ET-NV@-@
H7ET-NV@-@HH7ET-NFV@-@H7ET-N@-@
Supply voltage Backlight model: 24 VDC (0.3 W max.)
(for backlight)
No-backlight model: Not required (pow-
ered by built-in battery)
Not required (powered by built-in battery)
Timer input High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC
(Input impedance: Approx. 4.7 kΩ)
High (logic) level: 24 to 240 VAC/VDC,
50/60 Hz
Low (logic) level: 0 to 2.4 VAC/VDC, 50/
60 Hz
No voltage input
Maximum short-circuit impedance:
10 kΩmax.
Short-circuitresidualvoltage:0.5Vmax.
Minimum open impedance: 750 kΩmin.
Reset input No voltage input
Maximum short-circuit impedance:
10 kΩmax.
Short-circuit residual voltage:0.5 V max.
Minimum open impedance: 750 kΩmin.
Minimum pulse
width 1 s
Reset system External reset and manual reset: Minimum signal width of 20 ms
Terminal screw
tightening torque 0.98 N·m max.
Ambient tempera-
ture Operating: –10°C to 55°C (with no condensation or icing)
Storage: –25°C to 65°C (with no condensation or icing)
Ambient humidity Operating: 25% to 85%