Omron ZN-KMX21 Series User manual

ZN-KMX21-
Power Sensor Station
©OMRON Corporation
2011-2018
All Rights Reserved.
Tighten the terminal screws at a recommended torque: 0.69
to 0.88N·m. Make sure that the screws are not slanted away
from the center after tightened.
40
2-4 Dia.
2-M3
60
56.8
117.2
24.6 0.7
48.6
49.4
40
60
■Dimensions
PRECAUTIONS ON SAFETY
Indicates a potentially hazardous situation which, if
not avoided, will result in minor or moderate injury, or
may result in serious injury or death. Additionally
there may be significant property damage.
This product uses a lithium battery that contains perchlorate that is
regulated by California State Law. Appropriate measures must be taken to
comply with regulations.
For details, refer to the URL as below:
www.dtsc.ca.gov/hazardouswaste/perchlorate
WARNING
Indicates a potentially hazardous situation which, if
not avoided, may result in minor or moderate injury or
in property damage.
●Meaning of Precaution Symbols
●Mandatory Requirement
Indicates a general mandatory requirement.
●Prohibition
Indicates general prohibition.
●Disassembly Prohibition
Indicates the possibility of accidents such as an electric shock
caused by unit disassembly.
●Electric Shock Warning
Warns against an electric shock under specific conditions.
●Explosion Warning
Warns against an explosion under specific conditions.
CAUTION
●Perchlorate regulations by the State of California, USA
●Meanings of Signal Words
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet primarily
describes precautions required in installing and operating the product.
Before operating the product, read the sheet thoroughly to acquire
sufficient knowledge of the product. For your convenience, keep the
sheet at your disposal.
The mounting magnets provided with the product have
strong magnetism. If the product is mounted using these
magnets, anyone wearing a heart pacemaker must not
operate the product; or the product must not be in proximity
of such a person.
This product contains lithium batteries. Serious injury may
occur due to fire or explosion. Do not attempt to
disassemble the product, deform it by applying pressure,
heat it in a high temperature (100°C℃ or more), or burn it
for disposal.
●Warning Indications
WARNING
CAUTION
A minor or moderate injury or property damage may occur
due to explosion. Do not use the product in an environment
containing an inflammable or explosive gas.
An electric shock may occur. Do not replace the batteries
when the unit is clamped to a conductor for measurement.
Observe the following precautions to ensure safe operation.
• Do not install the product in the places subject to exposure to water, oil, or chemical splashes.
• Only the provided AC adapter (not other) must be used when using AC power supply.
• If a voltage that exceeds the rated voltage is applied to the AC adapter, smoking may occur. Do
not connect a power supply that exceeds the rated voltage. In a situation where a voltage
higher than the rating is applied, use protective equipment so that the power supply voltage
does not exceed the rated voltage.
• Dispose of the product as industrial waste.
• Do not let the product drop or subject it to a shock, which may cause its damage or malfunc-
tion. Use screws to secure the product when mounting it on the wall. Stop using the product if
it has been applied with a strong impact.
• When inserting or removing an SD card, securely hold the product to prevent it from dropping,
which may cause a damage. Do the same when inserting or detaching an AC adapter, alarm
output cable, or sensor connector.
• Do not bring the product close to magnetic products (e.g. magnetic cards), sensitive electronics
equipment (e.g. computers or clocks), when the product is attached with the mounting magnets.
• Small pieces may be chipped off the mounting magnets when they are attracted to the surface.
Make sure the pieces do not enter the eyes. Consult a medical doctor if this happens.
• When using the mounting magnets to install the product, take caution not to allow a finger to
be caught between the product(s) and the magnetic surface.
• Do not install the product at a high place when using the mounting magnets.
• Apply an appropriate load to the alarm output terminals to prevent possible smoking.
• If liquid crystal leaks due to a damage to the LCD panel, take caution not to allow it to contact
your skin, to be inhaled or swallowed. If it has contacted your skin or entered your mouth, seek
medical attention.
• Take anti-static electricity measures (e.g. touching grounded metal object) when handling the
product.
■Applicable standards
・EN61326-1
・Electromagnetic environment : Industrial electromagnetic environment
(EN/IEC 61326-1 Table 2)
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
1. Avoid installing the product in the following places:
• Places exceeding the rated ambient temperature
• Places exposed to extreme temperature changes (where condensation occurs)
• Places subject to relative humidity exceeding the rated humidity range
• Places subject to corrosive or flammable gases
• Places subject to mist, droplets, coarse particles, fiber, salt, metal dust, or large amount of
particles
• Places subject to direct shock or vibration
• Places subject to direct sunlight
• Places subject to exposure to water, oil, or chemical splashes
• Places subject to strong magnetic field or electric field
• Outdoors
2. Wiring
• Wire the product cable separately from high-voltage or power lines. Placing them in the same
wiring or the same duct may cause induction, resulting in the product malfunction or damage.
• Make sure that the I/O terminals are inserted or removed with the power turned OFF. Doing
this with the power ON may result in a failure.
• When using a DC cable, connect the white-lined wire of the cable to the power input (24 VDC
± 3%) and the non-lined wire to 0V.
• Use a ferrite core to reduce the noise to/from other device when supplying power to the unit
via a DC cable. To use the provided DC cable, attach the provided ferrite core as shown
below.
3.Mounting screw holes
• The screw holes provided on the product are M3 and 4 mm deep. Do not screw deeper than 4
mm, which may damage the product.
4.Operation
When using the product, also read KM series power sensor/monitor instruction sheets for
necessary information relevant to the product.
• The Power Sensors/Monitors that can be connected to the product are KM20-B40-FLK,
KM50-C, KM50-E, KM100, KM-N1-FLK, KM-N2-FLK and KM-N3-FLK.
To directly connect KM-N1-FLK, KM-N2-FLK and KM-N3-FLK to ZN-KMX21-, please
purchase a separately sold dedicated connection cable ZN9-KMC30-N.
5.Long Term Storage
If the product will not be used for a long period of time, store the product in the location
where the temperature is not too high. Otherwise the built-in battery may drain faster.
Screw hook holes dimensions
Mounting hole process dimensions
Screw hook hole
Mounting screw hole 2-M3,
4 mm in depth
Reset switch
LAN port SD card slot Alarm output terminal
Sensor head connector
Power supply
input terminal
MODE key
Select key
(upper direction)
Select key
(lower direction)
SET/REC/STOP key
Display
(Unit: mm)
Single winding
Portable Power Monitor unit side
approx. 100 mm Power supply side
Model
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
TRACEABILITY INFORMATION:
Importer in EU:
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
*9521958-0G*

■Overview and Features
By connecting the power monitor/sensor KM series (sold separately), the ZN-KMX21-
□
allows you to record the measured data of the power monitor/sensor (KM series) and set
various operations.
●Display and judgment output
The display of the measured data can be switched with the ▲and ▼keys. Also,
you can select the measurement target of the monitoring target and set the
threshold value to output an alarm from the output terminal.
●Data output and viewing
Measurement values can be recorded to the unit's memory and the recorded
measurement values can be stored into the SD card.
SD card : Data is in CSV format.
Measured values collected on multiple sensors can be displayed as a graph and
combined as a single file by using the PC software that can be downloaded from
the product page.
■Names and Functions
Display MODE key
Item select key
( key)
Item select key
( key)
SET/REC/STOPkey
Alarm output terminal
SD card slot
Sensor head
connector
AC adapter terminal
Mounting
screw hole
Reset switch
Screw hook hole
Function
Switches operating modes
Releases error and alarm (holding)
Cancels during settings
Moves setting items (upper direction)
Switches display screens (reverse direction)
Changes the setting value (increasing)
Moves the setting items (lower direction)
Switches the display screens (forward direction)
Changes the setting value (decreasing)
Confirms the setting value
Starts/stops record (holding)
Saves recorded data to the SD memory card.
Used to secure screws (M3x4 mm female hole)
For screw head hook
Restarts the unit.*
Name
MODE key
Item select key
( key)
Item select key
( key)
SET/REC/STOP key
Mounting screw hole
Screw hook hole
Reset switch
* Used when an SD card is not available when recording stops, or when error
recovery cannot be made.
LAN port
■Alarm Output Specifications
GND
External
power
supply
OUT
0V
Load
GND OUT
●Terminals
●Output Specifications
Terminal names are inscribed on the unit.
For wire used for a terminal block,consider the following.
Wire length:30m and less
(1) OUT
Judgment result allocated in THR mode is output.
(2) GND
Common terminal.
Do not directly connect the external power supply between OUT and GND.
Be sure to connect the load.
External power
supply voltage
Load current
ON residual voltage
OFF leakage current
Internal circuit
diagram
12 to 24 VDC
12 to 24 VDC ±10%
45 mA max.
1.2 V max.
0.1 mA max.
■Display Unit
Display Meaning and operation when turned on
Communication with LAN cable.
Integral power consumption reset interval is set.
The setting is OFF when it is not displayed.
LAN cable is connected and network communication is possible.
Recording data into the internal memory.
Recording start wait using timer when blinking.
Power is supplied.
Indicates the upper limit threshold value.
Indicates the maximum total momentary power value.
Indicates the minimum total momentary power value.
Indicates the average total momentary power value.
The unit is currently operating in RUN mode.
The unit is currently operating in FUN mode.
The unit is currently operating in THR mode.
SD card has been inserted.
SD card is being accessed while light blinking.
A total integrated power consumption has exceeded the specified
upper threshold value.
■7-segment Display List
■Ratings
Item
Connectable Power Sensor/Monitor
Model
KM20-B40-FLK, KM50-C, KM50-E, KM100, KM-N1-FLK, KM-N2-FLK and KM-N3-FLK
ZN-KMX21-□
Accessories
10 to 150 Hz, 0.7 mm double amplitude, acceleration: 50 m/s2 for each in X, Y and Z directions for 80 min
*
7
150 m/s2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each*7
Instruction Sheet (This sheet), Startup Guide,
Alarm Output Connector*7, AC Adapter*8, *9, DC Cable*9, and Dedicated Connection Cable
ABS
IP30
Magnet mounting, screw mounting, hook, free standing
Approx. 500 g
Shock Resistance
Material
Degree of Protection
Mounting
Weight (in Package)
Max. Number of Connectable
Power Sensor/Monitor Units
Display
Recording Interval
Recorded data
Operation Function
Recording Mode
External Output
Communication Interface
Memory Capacity (Internal)
Memory Capacity (External)
Power Supply
Current Consumption
Operating Temperature
Operating Humidity
Storage Humidity/Temperature
Insulation Resistance
Withstand Voltage
Vibration Resistance
7-seg. 5-digit 2-step LCD display, auxiliary information indicator displays
1 s, 2 s, 5 s, 10 s, 20 s, 30 s, 1 min.
Momentary power, Integrated power, Power factor, Sum of pulse input counts 1 and 2 *1
Integrated power total sum, integrated momentary power, electricity rate total sum
Continue mode*2, Ring mode *3
Alarm output (Photocoupler output) *4
Ethernet (10BASE-T, 100BASE-TX)
Internal memory: approx. 200 data items (at maximum load); approx. 6800 data items*5 (at minimum load)
SD card with SDHC compatibility (measured value and converted value saving/set value saving and reading):
Recommended SD card: HMC-SD291(2GB)/HMC-SD491(4GB)(manufactured by OMRON) *6
DC input: 24 VDC±10%, AC adapter: 100 to 240 VAC/50 to 60 Hz
80 mA max. (at 24 VDC); 70 mA max. (AC adapter used)
Without Ethernet: -10°C to 40°C (no condensation or icing) With Ethernet: 0°C to 40°C (no condensation or icing)
20 to 85%RH (no condensation or icing)
-15°C to +60°C, 20 to 85%RH (no condensation or icing)
20 MΩ (500 VDC)
1000 VAC, 50/60 Hz, 1 min.
31 units
*1: Only supported for KM50-C and KM50-E.
*2: Automatically writes the data to the SD memory card when the internal memory reaches its capacity and continues recording until the SD card memory capacity reaches its limit. The
unit stops operation if there is no SD memory card inserted when the internal memory reaches its capacity. (Recording can be resumed after inserting an SD memory card and
outputting the data to it at a press of button.)
*3: Continues the recording of the latest measured values until the internal memory reaches its capacity. (If the internal memory capacity exceeds the capacity, data is overwritten from
the oldest one in the memory.)
*4: Output when the integrated power upper limit specified in THR mode is exceeded.
*5: The maximum load is applied when 10 KM50-� units are connected; and the minimum load, when a single KM20-B40-FLK is connected.
*6: When using third party SD card, please use industrial SD card (flash memory is SLC type) with high reliability and durability. Available SD card is SD standard or SDHC standard,
Class 4 or higher, (SDXC standard can not be used) You must confirm the operation of third party SD card yourself.
*7: The vibration resistance when mounted using the ZN9-EM01-S magnets (separately sold): 10 to 55 Hz, 0.3mm double amplitude, acceleration: 20m/s2 for each in X, Y and Z
directions for 50 min. The installation place must be free from physical shock.
*8: OMRON's XW4B-02B1-H1 connector.
*9: This provided AC adapter must be used.
*10: An AC adapter is provided in the ZN-KMX21 package; and a DC cable and ferrite core are included in the ZN-KMX21-A package.

10. Unit Setting
Select UNIT in FUN mode and input the number of the connected KM series units.
The Power Sensor Station resets itself to apply the setting, when the mode is
changed from FUN to THR.
8. KM series settings
Set the KM series as shown below. For details, refer to the instruction manual of
the KM series.
Communication Speed: 38.4 kbps
Data Bit Length: 7-bit
Stop Bit Length: 2-bit
Vertical Parity: EVEN
When connecting multiple KM series, assign unique consecutive numbers for the
unit No. of each device.
7. Turning ON the power supply of KM-□□
Turn ON the power supply of the KM series first to initialize the sensor unit
normally.
6. Connecting the sensor to the power monitor/sensor KM□□
Connect the terminal part of the provided dedicated cable to KM□□. Connect the
RS-485(+) side to RS-485(+) of the KM□□side, and the RS-485(-) side to
RS-485(-). (Recommended tightening torque: 0.69 to 0.88 Nm)
Insert the connector (male) into the sensor head connector (female) of the right side
of the unit.
9. Turning ON the power supply of the unit
(1) Insert the plug of the AC adapter or DC cable into the power supply input
terminal of the unit.
(2) For AC adapter, connect the AC plug into an outlet (100 VAC to 240 VAC).
For DC cable, connect the cable with white line to the power supply (24
VDC±10%) and cable without a line into the 0 V.
CYCLE
UNIT
INT H
REC
INTEG
INIT
ETC
RESTR
BCKUP
CLOCK
IP
RATE
CONV
UTOFS
REREC
YEAR
MONTH
DAY
TIME
TOTAL
IP1 to IP4
SUB1 to SUB4
Electricity rate total
sum/CO2 emission
conversion value
Conv. unit
Uno1*
Uno1*
- -
-
IP1
SUB 1
This product is precision equipment. Be careful not to drop the product when
mounting it.
Do not drop the product or apply strong impact to the product.
If strong impact is applied to the product, stop using the product.
■Mounting
M3
screws
1. When using mounting screw holes
The unit screw hole depth is 4 mm. Be careful not to tighten the screw for more
than 4 mm.
The product can be mounted with magnet by mounting mounting magnets
(ZN9-EM01-S, sold separately) to the screw hole. (tightening torque: 0.4 N/cm to
0.6 N/cm)
Do not stress to the sensor head cables, when mounting the magnet.
Flat head screws (M3x6)
Mounting magnets
2. When using screw hook holes
There are two hook holes below the convex section of the upper unit. Use M3 screws
to hook the screw head on the screw hook holes. Set an interval of 2.5 mm or more
between the bottom of the screw head and the wall surface.
Enlarged view of the hook screw
3. Floor installation
Use the product on a desk, etc.
Be careful of the installation location not to drop the product.
2.5 mm min.
4. Inserting the SD card
Insert an SD card into the SD card connector at the bottom of the unit. Insert it with
the terminal side of the SD card to the front side of the unit.
5. Mounting the alarm output terminal
Connect OUT and GND to the load according to the output specifications. Insert the
signal line to the alarm output connector and tighten it with flathead screwdriver.
AC adapter DC power supply
■Transition of Major Menu Displays
Press the MODE key twice.
Transition is not available during recording.
MODE key
MODE key
FUN mode THR mode
RUN mode
Momentary
power total sum
Momentary power
total sum
Elapsed time
(min., sec.)*
Elapsed time
(day, hr.)*
Auto switching
Auto switching
Auto switching Auto switching
Average of recorded
momentary power
total sum
Momentary power
total sum
* The elapsed time from the measurement start.
Displayed in "min., sec." units during the first hour.
Maximum of recorded
momentary power
total sum
Minimum of recorded
momentary power
total sum
Momentary power
Momentary power
total sum
Integrated power
total sum
Threshold value
Integrated power
total sum
Threshold rate*
Number of data
items recorded in
the internal memory
Current time
Displayed up to No. 31
in the same way.
* Represents "Unit No. 1".
* The current power ratio of integrated
power total sum for the configured
threshold value.
Setting value (kWh)
Displayed only
when ETC setting
is DISP Displayed only when
CLOCK setting is
DISP
Displayed only
when IP setting is
DISP
DC power supply

UNIT No. of connected Power
Sensor Station/Monitor 1 to 31
Sets the number of connected Power Sensor Stations/Monitors. 1
REC - -
- -
- -
- -
- -
UTOFS Unit No. offset setting
1 to 99
1
●FUN mode
■Major Error Displays and Countermeasures
E1100
E2001
E2002
E2003
E3000
E3002
E3003
E5000
E5001
E5002
HARD
Display Description
Failed to write recorded data to the SD memory card. Insert a write-enabled SD card. Hold the MODE key for 3 seconds or more to cancel the error display.
A sensor different from the one auto-registered at startup is mounted. Restart the unit.
Communication with the sensor failed. Check the wiring between the sensor and the main unit. To cancel the error display, press and hold the MODE key for 3 seconds or more.
Failed to register the sensor in the initial processing on startup. Check the wiring between the sensor and the main unit, and restart the main unit.
If you turn on the power of the main unit before the sensor starts up, the sensor cannot be properly registered.
An SD memory card is not inserted. Insert a write-enabled SD card. Hold the MODE key for 3 seconds or more to cancel the error display.
The SD memory card is write-protected. Replace it with a write-enabled one. Hold the MODE key for 3 seconds or more to cancel the error display.
Failed to recognize the SD card. Insert a normal SD memory card. Hold the MODE key for 3 seconds or more to cancel the error display.
The setting data in the SD memory card is invalid e.g. an invalid model type or setting values. Hold the MODE key for 3 seconds or more to cancel the error display.
Failed to write setting files to the SD memory card. Insert a write-enabled SD card. Hold the MODE key for 3 seconds or more to cancel the error display.
There is no setting files contained in the SD memory card. Replace it with an SD memory card with setting files.
Hold the MODE key for 3 seconds or more to cancel the error display.
There may be a failure on the hardware. Please contact the distributor or OMRON representative office.
Overview
Recorded data writing failure
Sensor error
Sensor communications error
Sensor registration failed
No SD memory card inserted
Write-protected SD memory card
SD card recognition error
Invalid setting file data
Setting file writing failure
Setting file reading failure
Hardware error
■List of Major Setting Items
RUN
FUN
THR
Mode Description
Performs measurement/recording.
Sets various parameters.
Performs condition settings regarding alarm outputs.
Item
Measurement execution mode
Function setting mode
Threshold setting mode
●Operation mode
Item Overview Setting rangeDescription Default
Specifies the starting (offset) unit number set for the Power Sensor/Monitor units to
be connected. To use the unit numbers from No.10 to No.15, for example, "10" is set
for the offset number (this setting item), while "6" is set for the number of Power
Sensor/Monitor units to be connected (UNIT).
CYCLE Recording interval setting 1s/2s/5s/10s
20s/30s/1min
Sets an recording interval of the measured value. 10s
Recording operation mode setting
CONT/RING
Sets operation for a case in which the internal memory capacity reaches the limit during recording.
CONT
CONT Continue mode Outputs a recorded value to the SD card and continues recording when the
internal memory capacity reaches the limit during recording.
RING Ring mode Overwrites a recorded value to the SD card and continues recording when the
internal memory capacity reaches the limit during recording.
INTEG Setting of reset interval of
integrated power consumption OFF/30 m
1 h/24 h
Specifies the integrated power reset interval. The integrated power value is reset at the
specified time interval, displaying the data belonging to that interval.
OFF
INIT Setting initialization
Initializes the unit setting to the factory default value. Holding the SET/REC/STOP key
starts initialization. Changing measurement operation mode with the MODE key after
DONE is displayed initializes the settings and the unit restarts.
ETC Display setting for other items OFF/DISPSets whether displaying other setting items. OFF
RESTR Read setting data Recovers the setting from the SD card in which the setting data
of the sensor unit is stored. Insert the SD card and hold the
SET/REC/STOP key. Writing completes when DONE is displayed.
BCKUP Write setting data
Writes the setting data of the sensor unit to the SD card as a backup. Insert the SD card
and hold the SET/REC/STOP key. Writing completes when DONE is displayed.
CLOCK Time setting OFF/DISP
Sets whether displaying the time setting item. OFF
RATE Rate conversion setting 0.000 to 99.999Sets the conversion coefficient to convert the integrated power consumption to rate. 0
CONV Conversion unit setting
JPY/USD/EUR
CNY/KRW/CO2
Sets the conversion unit. JPY
REREC Power failure REC restoration OFF/ONSets whether writing data and starting recording at next startup
after power shutdown during recording. OFF
INT H (Unit: kWh)
Displayed item Setting range
0 to 99999
Overview
Upper threshold setting of the integrated power consumption (kWh or more)
Default
0
●THR mode
■Connected Units and Recording Interval
1 second
2 seconds
5 seconds
10 seconds
20 seconds
30 seconds
1 minute
Minimum recording interval 1 unit
Up to 2 units
Up to 6 units
Up to 12units
Up to 24 units
Number of units
Up to 31 units
The possible minimum recording interval varies depending on the number of power
sensors/monitors. Check the following table of the number of units that can be
connected to set the recording interval.
■Recording Interval and Internal Memory
Recording Interval
Approx. 1 hr. 50 min.
Approx. 3 hr. 40 min.
Approx. 9 hr. 30 min.
Approx. 19 hr.
Approx. 1 day 14 hr.
Approx. 2 days
Approx. 4 days
Min. load
(KM20 x 1 unit)
-
-
-
-
-
Approx. 1 hr. 40 min.
Approx. 3 hr. 20 min.
Max. load
(KM50 x 31 units)
Example of possible recording time in the internal memory
An example of the possible recording time in the internal memory that varies
depending on the recording interval setting is shown below.
1 second
2 seconds
5 seconds
10 seconds
20 seconds
30 seconds
1 minute
IP IP address display setting OFF/DISPSets whether performing IP address setting. OFF
●Notice for Korea Radio Law
A급 기기(업무용 방송통신기자재)
이 기기는 업무용(A급) 전자파적합기기로서 판매자
또는 사용자는 이 점을 주의하시기 바라며,가정외의
지역에서 사용하는 것을 목적으로 합니다.
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR ANAPPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters
Other manuals for ZN-KMX21 Series
1
This manual suits for next models
2
Other Omron Measuring Instrument manuals

Omron
Omron K35-2 User manual

Omron
Omron KM1 User manual

Omron
Omron H8PS User manual

Omron
Omron H7CX - User manual

Omron
Omron K3GN User manual

Omron
Omron K7DD User manual

Omron
Omron K3HB-C Series User manual

Omron
Omron Sti G9SX-SM032 Series User manual

Omron
Omron K3GN - V1.04 User manual

Omron
Omron K3NC User manual

Omron
Omron G9SX-SM User manual

Omron
Omron EQUO Series User manual

Omron
Omron HEM-RML30 User manual

Omron
Omron K6CM series User manual

Omron
Omron H7CC-A Series User manual

Omron
Omron OKA-450R User manual

Omron
Omron K6CM series User guide

Omron
Omron K6CM series User manual

Omron
Omron K6PM-TH User manual

Omron
Omron K3MA-J Series User manual