1
Switching Power Supply S82J
Compact and Economical Switching Power Supplies with Capacities Up to 600 W
Power range from 10 W up to 600 W.
Output Voltages: 5 V, 12 V, 15 V, or 24 V.
Wide AC input range
50-/100-W, 24-V output models: 100 to 240 VAC on one body
150-W models: 100 or 200 VAC selected automatically
300-/600-W models: 100 or 200 VAC selectable
Open-frame and covered types available.
Top terminal- and connector-type available in addition to front terminal type (100-/150-W models).
Mounting brackets provided for mounting to control panels.
Easily mounted to DIN track with S82Y (sold separately).
Maintenance-free up to 300 W due to natural ventilation.
Protection-ON alarm indicator shows valuable protection functions in action (300-/600-W models).
Conforms to EMC standards: EN50081-2 and EN50082-2.
With
an external filter
, achieves conformance to EN50081-1 for universal
usage on EMI (300-/600-W models).
Finger protection terminal block to meet VDE0106/P100
(50-/100-/150-W, 24-V output, covered type)
Class 2 approved (50-W, 24-V output models)
The UL Listed Power Supplies (50-/100-/150-W, 24-V output models) can be used at full rated power at any
location.
Approved by UL/CSA standards, EN60950, and EN50178 (VDE0160).
Six-language instruction manual provided.
WuRC
S82J
<10 W to 100 W>
•100-VAC input
•200-VAC input
•100 to 240 VAC (50-/100-W
24-V output models)
<150 W>
•100 or 200 VAC (selected
automatically)
<10 W to 100 W>
•100-VAC input
•200-VAC input
•100 to 240 VAC (50-/100-W
24-V output models)
<150 W>
•100 or 200 VAC (selected
automatically)
<300/600 W>
•100 or 200 VAC (selectable)
Covered TypeOpen-frame Type Enclosure Type

S82J S82J
2
Ordering Information
S82J
Configuration Input
Voltage Power
ratings Output
voltage Output
current Front
terminals
T
op terminals
Connector
Open-frame
t
100 V
AC
10 W
5 V 2 A
S82J-0105 --- ---
Ope a e
type
12 V
1 A
S82J-0112 --- ---
15 V
0.7 A
S82J-0115 --- ---
24 V
0.5 A
S82J-0124 --- ---
25 W
5 V 5 A
S82J-0205 --- ---
12 V
2.1 A
S82J-0212 --- ---
15 V
1.7 A
S82J-0215 --- ---
24 V
1.1 A
S82J-0224 --- ---
50 W
5 V
10 A
S82J-0505 --- ---
12 V
4.2 A
S82J-0512 --- ---
100 W
5 V
20.0 A
S82J-10005A1 S82J-10005B1 S82J-10005C1
12 V
8.5 A
S82J-10012A1 S82J-10012B1 S82J-10012C1
15 V
7.0 A
S82J-10015A1 S82J-10015B1 S82J-10015C1
200 V
AC
10 W
5 V 2 A
S82J-2105 --- ---
12 V
1 A
S82J-2112 --- ---
15 V
0.7 A
S82J-2115 --- ---
24 V
0.5 A
S82J-2124 --- ---
25 W
5 V 5 A
S82J-2205 --- ---
12 V
2.1 A
S82J-2212 --- ---
15 V
1.7 A
S82J-2215 --- ---
24 V
1.1 A
S82J-2224 --- ---
50 W
5 V
10 A
S82J-2505 --- ---
12 V
4.2 A
S82J-2512 --- ---
100 W
5 V
20.0 A
S82J-10005A2 S82J-10005B2 S82J-10005C2
12 V
8.5 A
S82J-10012A2 S82J-10012B2 S82J-10012C2
15 V
7.0 A
S82J-10015A2 S82J-10015B2 S82J-10015C2
100 to
240 V
AC
50 W
24 V
2.1 A
S82J-05024A --- ---
00 o
240 V
AC
100 W 24 V 4.5 A
S82J-10024A --- ---
100 or
200 V
AC
(selected
automatically)
150 W 24 V 6.5 A
S82J-15024A S82J-15024B S82J-15024C

S82J S82J
3
Configuration ConnectorT
op terminals
Front terminals
Output
current
Output
voltage
Power
ratings
Input
Voltage
Covered type
100 V
AC
10 W
5 V 2 A
S82J-5105 --- ---
Co e ed ype
12 V
1 A
S82J-5112 --- ---
15 V
0.7 A
S82J-5115 --- ---
24 V
0.5 A
S82J-5124 --- ---
25 W
5 V 5 A
S82J-5205 --- ---
12 V
2.1 A
S82J-5212 --- ---
15 V
1.7 A
S82J-5215 --- ---
24 V
1.1 A
S82J-5224 --- ---
50 W
5 V
10 A
S82J-5505 --- ---
12 V
4.2 A
S82J-5512 --- ---
100 W
5 V
20.0 A
S82J-10005D1 S82J-10005E1 S82J-10005F1
12 V
8.5 A
S82J-10012D1 S82J-10012E1 S82J-10012F1
15 V
7.0 A
S82J-10015D1 S82J-10015E1 S82J-10015F1
200 V
AC
10 W
5 V 2 A
S82J-6105 --- ---
12 V
1 A
S82J-6112 --- ---
15 V
0.7 A
S82J-6115 --- ---
24 V
0.5 A
S82J-6124 --- ---
25 W
5 V 5 A
S82J-6205 --- ---
12 V
2.1 A
S82J-6212 --- ---
15 V
1.7 A
S82J-6215 --- ---
24 V
1.1 A
S82J-6224 --- ---
50 W
5 V
10 A
S82J-6505 --- ---
12 V
4.2 A
S82J-6512 --- ---
100 W
5 V
20.0 A
S82J-10005D2 S82J-10005E2 S82J-10005F2
12 V
8.5 A
S82J-10012D2 S82J-10012E2 S82J-10012F2
15 V
7.0 A
S82J-10015D2 S82J-10015E2 S82J-10015F2
100 to
240 V
AC
50 W
24 V
2.1 A
S82J-05024D --- ---
00 o
240 V
AC
100 W 24 V 4.5 A
S82J-10024D --- ---
100 or
200 V
AC
(selected
automatically)
150 W 24 V 6.5 A
S82J-15024D S82J-15024E S82J-15024F
Enclosure
t
100 or 200
VAC
300 W 24 V
14.0 A
S82J-30024 ---
c osu e
type
00 o 00
VAC
(selectable)
600 W 24 V
27.0 A
S82J-60024 ---
(
se
l
ec
t
a
bl
e
)
300 W 24 V
14.0 A
S82J-30024N ---
600 W 24 V
27.0 A
S82J-60024N ---

S82J S82J
4
Model Number Legend:
50
(24 V)-/100-/150-/300-/600-W Models
1.Power Ratings
050:
50 W
100:
100 W
150:
150 W
300:
300 W
600:
600 W
2. Output Voltage
05:
5 V
12:
12 V
15:
15 V
24:
24 V
3. Configuration
A:
Open-frame type, front terminals
B:
Open-frame type, top terminals
C:
Open-frame type, connector
D:
Covered type, front terminals
E:
Covered type, top terminals
F:
Covered type, connector
N:
Without Mounting Brackets
None:
Enclosure type, front terminals with
Mounting Brackets
S82J - 1 32 4
4.
Input V
oltage
1:
100 V
AC
2:
200 V
AC
None:
100 or 200 V
AC, selectable (for 300-/600-W models)
100 or 200 V
AC, selected automatically (for 150-W model)
100 to 240 V
AC (for 50-/100-W
, 24-V output models)
10-/25-/50 (5, 12 V)-W Models
1.Input V
oltage/Configuration
0:
100 V
AC/Open-frame type
2:
200 V
AC/Open-frame type
5:
100 V
AC/Covered type
6:
200 V
AC/Covered type
2. Power Ratings
1:
10 W
2:
25 W
5:
50 W
3. Output Voltage
05:
5 V
12:
12 V
15:
15 V
24:
24 V
S82J - 1 2 3
Accessories (Order Separately)
Name S82J-j1jj S82J-j2jj S82J-j5jj S82J-100jjjj
S82J-15024jj S82J-30024j
S82J-60024j
DIN
T
rack Mounting Bracket
S82Y-01N S82Y-03N S82Y-05N S82Y-10N ---
Mounting Bracket
S82Y-J10F
for 100 W
, 24 V
(F-type) only
---
Fan --- S82Y-JFAN for
600-W models
only
Ferrite Ring Core --- S82Y-JC-T (set of
3 pieces in
package)
Noise Filter
--- S82Y-JF3-N (for
30- W models)
S82Y-JF6-N (for
600-W models)
Mounting T
rack
PFP-100N, PFP-50N, PFP-100N2

S82J S82J
5
Specifications
Ratings/Characteristics
Item 100
V
AC input/200 V
AC input
100 or 200 V
AC
(selectable)
100 to 240 V
AC input
100 or 200
VAC
(selected
automatic
ally)
10 W 25 W 50 W
(5, 12 V)
100 W (5,
12, 15 V) 300 W 600 W
50 W
(24 V)
100 W
(24 V)
150 W
Ef
ficiency (typical)
67% min. 76% min. 82% min. 77% min. 83% min. 82% min.
Input Voltage
100 V
AC
input
100 V
AC (85 to 132 V
AC), 1
10 to 170 VDC
(see note 1)
100 (85 to 132) or 200
(170 to 253) V
AC
(selectable)
100 to 240 V
AC (85 to
264 V
AC)
100 (85 to
132) or 200
(170 to
264) V
AC
200 V
AC
input
200 V
AC (170 to 264 V
AC)
264) V
AC
(selected
automatical
ly)
Frequency
50/60 Hz (47 to 450 Hz)
Current
(see note
2)
100 V
AC
input
0.35 A
max.
0.8 A
max.
1.4 A
max.
2.5 A
8 A max.
14 A max.
1.4 A
max.
2.5 A
max.
3.5 A max.
(see
note
2)
200 V
AC
input
0.3 A
max.
0.6 A
max.
0.8 A
max.
1.4 A
4 A max. 7 A max.
0.8 A
max.
1.5 A
max.
2.1 A max.
Leakage
current
(t
100 V
AC
input
0.5 mA max.
current
(see note
2)
200 V
AC
input
1 mA max.
Inrush
current
(
25°C,
100 V
AC
input
25 A max. 30 A max. 25 A max.
(25 C
,
cold start)
(see note
2)
200 V
AC
input
50 A max. 60 A max. 50 A max.
Noise filter
Yes
Output
(see note
3)
V
oltage adjustment
range ±
10% (adjustable with variable resistor (V
.ADJ))
(see
note
3)
Ripple (see note 2)
2% (p-p) max.
Input
variation
ifl
100 V
AC
input
0.4% max. (at 85 to 132 V
AC input, 100% load)
0.4% max.
variation
influence
200 V
AC
input
0.4% max. (at 170 to 264 VAC input, 100% load)
Load variation
influence
0.8% max. (with rated input, 10% to 100% load)
T
emperature variation
influence 0.05%/°
C max. (with rated input and output)
Rise time
200 ms max. (up to 90% of output voltage at
rated input and output)
300 ms max. (up to
90% of output voltage
at rated input and
output)
500 ms min. (up to 90% of output
voltage at rated input and output)
Hold time (see note 2) 20 ms min.
Additional
function
Overload protection
105% min. of rated load current, inverted L drop type, automatic reset (For
the 600-W model, the circuit will be shut OFF when the overload exceeds
5±
3s. Protection-ON alarm indicator lit. (see note 4)).
105 to 160% of rated
load current, inverted L
drop/Intermittent
operation type,
automatic reset)
105% min.
of rated
load
current,
inverted L
drop type,
automatic
reset
Overvoltage protection
(see note 5)
No Y
es (5-V
output
models
only)
Y
es, protection-ON
alarm indicator lit.
No Yes No
Overheat protection
No Yes,
protection
-ON
alarm
indicator
lit (see
note 4)
No
Protection-On alarm
indicator No Y
es (color
, red)
No
Parallel operation
No Y
es, 5 units max.
No
Series operation
No Yes

S82J S82J
6
Item
100 or 200
VAC
(selected
automatic
ally)
100 to 240 V
AC input
100 or 200 V
AC
(selectable)
100 V
AC input/200 V
AC input
Item
150 W100 W
(24 V)
50 W
(24 V)
600 W300 W100 W (5,
12, 15 V)
50 W
(5, 12 V)
25 W10 W
Other
Ambient temperature
Operating: See the derating curve in the Engineering Data section.
Storage: –25
°
C to 65
°
C (with no condensation and icing)
Ambient humidity Operating: 25% to 85%
Storage: 25% to 90%
Dielectric strength
3.0 kV
AC, 50/60 Hz for 1 min (between all inputs and all outputs)
Dielectric
strength
2.2 kV
AC, 50/60 Hz for 1 min (between all inputs
and all inputs/GR terminals)
2.2 kV
AC, 50/60 Hz for 1 min (between all inputs and GR
terminals)
---
1.0 kV
AC, 50/60 Hz for 1 min (between all outputs and GR
terminal)
Insulation resistance
100 M
Ω
min. (between all outputs and all inputs/GR terminals at 500 VDC)
V
ibration resistance
10 to 55 Hz, 0.375-mm double amplitude for 2 h each in X, Y
, and Z directions
Shock resistance
294 m/s
2
, 3 times each in
±
X,
±Y
, and
±
Z directions
T
erminal screw
tightening torque
0.74 N
S
m
1.08 N
S
m
0.74 N
S
m
1.08 N
S
m
Output indicator
Y
es (green)
Electromagnetic
interference (see note
2)
Conforms to FCC Class A
EMC
Emission Enclosure:
EN5501
1 class A
Emission AC Mains:
EN5501
1 class A
Immunity ESD:
EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: ENV50140:
10 V/m
2
(80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance:
ENV50141: 10 V (0.5 to 80 MHz) (level 3)
Immunity Burst:
EN61000-4-4:
2 kV power-line (level 3)
2 kV output line (level 4)
EMC standards
Conforms to EN50081-2 and EN50082-2
Conforms to
EN50081-2 and
EN50082-2 (see note
6)
With noise filter
,
confirms to EN50081-1
(see note 6 and 7)
Conforms to EN50081-2 and
EN50082-2
Approved
standards UL UL508/1012 UL508 UL508/1012
Class 2
(per
UL1310),
UL508
(Listing)/
1950
UL508 (Listing)/
1012/1950
(see note 8)
CSA
CSA C22.2 No. 14
CSA EB1402C
Class 2
(per CSA
C22.2 No.
950),
CSA
C22.2 No.
14/
No. 950
CSA C22.2 No. 14/No.
950
VDE
EN50178 (VDE0160) and EN60950 EN50178 (VDE0160) and EN60950
For covered types, conforms to VDE
0106/P100
Weight
250 g
max. (see
note 9)
350 g
max. (see
note 9)
400 g
max. (see
note 9)
1,000 g
max.
2,000 g
max.
2,500 g
max.
500 g
max.
600 g
max.
1,000 g
max.
Note: 1. DC
inputs not included in safety standard approvals.
2.
At 100% load for rated input voltage (100 V
AC or 200 V
AC).
3.
The output specification is defined at the power supply output terminals.
4.
For resetting, turn OFF the power supply
, leave for more than three minutes, and then turn ON the power supply
.
5. For
resetting, turn OFF the power supply
, leave for more than one minutes (90 seconds min. for the 300-W models and 3 minutes
min.
for the 600-W models), and then turn ON the power supply
.
6. T
o ensure the Emission Enclosure rating ferrite ring cores (recommended model: S82Y-JC-T) should be used on all cabling.
7. To
ensure the Emission AC Mains rating for EN50081-1 (only for 200-V
AC input), a nose filter (recommended models: S82Y
-JF3-N
for
300-W
, S82Y
-JF6-N for 600-W) should be used on the input lines.
8.
With UL508, 150-W connector type has “Recognized” approval.
9.
The weight indicated is the weight of the open-frame type.

S82J S82J
7
Reference Value
Item Value Definition
Reliability
(MTBF)
135,000 hours
MTBF stands for Mean Time Between Failures, which is
calculated according to the probability of accidental device
failures, and indicates reliability of devices. Therefore, it does
not necessarily represent a life of the product.
Life expectancy
10-/25-/50 (5, 12 V)-/100 (5,
12, 15 V)-/150-W Models
8 yrs. Min.
The life expectancy indicates average operating hours under
the ambient temperature of 40
°
C and a load rate of 50%.
N ll thi i d t i d b th lif t f th
50 (24 V)-/100 (24 V)-/
300-/600-W Models
10 yrs. Min.
Normally this is determined by the life expectancy of the
built-in aluminum electrolytic capacitor
.
Engineering Data
Derating Curve
10-/25-/50-/100 (24 V)-/150-W Model
Open-frame type
Load (%)
Ambient
temperature (
°C)
Covered-type
Load (%)
Ambient temperature (
°C)
Standard Installation
Natural air-cooling
Forced air-cooling Forced
air-cooling
Natural air-cooling
Note: The derating curve shown is for
standard
installation. The derating
curve depends on the mounting
direction
of the Power Supply
.
100 (5, 12, 15 V)-W Model
Open-frame Type
Load (%)
Ambient
temperature (
°C)
Covered Type
Load (%)
Ambient
temperature (
°C)
Standard Installation
Note: The derating curve shown is for
standard
installation. The derating
curve depends on the mounting
direction
of the Power Supply
.
Natural air-cooling
Forced air-cooling (1 m3/min) Forced air-cooling
(1 m
3/min)
Natural air-cooling

S82J S82J
8
300-W Model
600-W Model
Single Operation
Parallel Operation
Standard mounting
Single Operation
Parallel Operation
Standard Mounting
20
mm min.
20 mm min.
20 mm min. 20 mm min.
Load (%)
Ambient
temperature (
°C)
Load (%)
Ambient temperature (
°C)
Load (%)
Ambient temperature (
°C)
Load (%)
Ambient temperature (
°C)
Forced air-cooling
(1 m
3/min)
(Standard mounting)
Natural air-cooling
(Standard mounting)
Forced air-cooling
(1 m
3/min)
(Side mounting)
Natural cooling
(Side mounting)
20 mm min. 20 mm min.
20 mm min. 20 mm min.
Natural air-cooling
(Standard mounting)
Forced air-cooling
(1 m
3/min)
(Side mounting)
Natural cooling
(Side mounting)
Forced air-cooling
(1 m
3/min)
(Standard mounting)
120
120
120
100 100
100
100
120
Note: Provide
a minimum clearance of 20 mm between the Power Supplies.

S82J S82J
9
Overload Protection
10- to 300-W Models
The
Power Supply is provided with an overload protection function
that
protects the load and the power supply
from possible damage
by overcurrent. When the output current rises above 105% of the
rated
output current (105% to 160% of the rated output current for 50
(24
V)-W and 100 (24 V)-W models), the protection function is
trig
-
gered,
decreasing the output voltage. When the output current falls
within the rated range, the overload protection function is automati
-
cally
cleared.
Output voltage (V)
Output
current (%)
Intermittent
operation
500 100
Output voltage (V)
Output current (%)
Rated voltage
10-
to 300-W Models
(except for 50 (24 V)-W and
100 (24 V)-W Models)
50 (24 V)-W and
100 (24 V)-W Models
Rated voltage
600-W Models
If
an excessive current flows for 5 s
or more, the output will be turned
off and simultaneously protection-ON alarm indicator will be lit. To
reset
the S82J, turn of
f the input voltage, leave the S82J for at least
three
minutes, and then apply the input voltage again.
Note: Do not continue using the S82J with the output terminals
short-circuited or the overcurrent condition continued,
otherwise the internal elements of the S82J may be dam-
aged
or broken.
Overvoltage Protection
100 (5, 24 V)-W Models
The
Power Supply is provided with an overvoltage protection func
-
tion
that protects the load and the Power Supply from possible dam
-
age
by overvoltage. When the
output voltage rises above a set val
-
ue
(120% of the rated output voltage),
the protection function is trig
-
gered, shutting of
f the output voltage. If this occurs, reset the Power
Supply by turning it off for 1 minutes min. and then turning it on
again.
Rated output
voltage
Output voltage (V)
Overvoltage
protection
operating
Variable range
300- and 600-W Models
If
a voltage that is 120% of the rated output
voltage or above is out
-
put,
the output voltage will be turned of
f and simultaneously protec
-
tion-ON
alarm indicator will be lit. T
o
reset the S82J, turn of
f the input
voltage, leave the S82J for at least three minutes if it is a 600-W
model
or at least 90 seconds if it is a 300-W model, and then apply
the
input voltage again.
Overheat Protection Function
600-W Model Only
If
the internal temperature of the S82J rises excessively as a
result
of
fan failure or any other reason, the overheat protection circuit will
be
triggered to protect the internal elements of the S82J and simul
-
taneously a protection-ON alarm indicator will be lit. To reset the
S82J,
turn of
f the input
voltage, leave the S82J for at least three min
-
utes,
and then apply the input voltage again.
Inrush Current, Rise Time, Hold Time
Input ON Input OFF
AC input
voltage
AC input
current
Output
voltage Rise time
(200 ms
max.)
Hold time
(20 ms
min.)
Inrush current on input application
90% 96.5%

S82J S82J
10
Operation
Block Diagrams
S82J-j1jj
(10 W)
S82J-j2jj
(25 W)
S82J-j5jj
(50 W
, 5-/12-V Output)
S82J-05024j
(50 W
, 24-V Output)
Drive
control
circuit
+V
–V
DC
Output
AC(L)
AC(N)
Fuse*
Noise filter
Inrush current
protection circuitRectifier
Rectifier
DetectorPhotocoupler
INPUT
*Fuse capacity: 10 W
, 2 A
25 W
, 2 A
50 W, 3.15 A for 100-V input
3 A for 200-V input
INPUT
AC(L)
AC(N)
Fuse (3 A)
Noise filter
Control circuit
Overload
detection
circuit Photocoupler
Overload
detection
circuit
+V
–V
DC Output
Inrush current
protection
circuit
Rectifier Smoothing
circuit Rectifier and
smoothing
circuit
+V
–V
DC Output
Input
AC (L)
AC (N)
*Fuse capacity
100-W, 100-V input type: 5 A
100-W, 200-V input type: 2.5 A
Fuse*
Noise filter
Inrush current
protection circuit Rectifier
Drive control circuit
Overcurrent
detector
Rectifier and smoothing
circuit
Detector
Overvoltage
detector
Overvoltage
protection circuit (5 V
only)
Photocoupler
S82J-100jjjj
(100 W
, 5-/12-/15-V Output)

S82J S82J
11
INPUT
AC(L)
AC(N)
Fuse
(5 A)
Noise filter
Control circuit
Overload
detection
circuit Photocoupler
Detector
+V
–V
DC Output
S82J-10024j (100
W
, 24-V Output)
Rectifier Inrush current
protection
circuit
Smoothing
circuit Rectifier and
smoothing
circuit
Photocoupler
Overload
detection
circuit
+V
–V
DC OutputInput
AC (L)
AC (N)
Fuse (8 A)
Noise filter
Inrush current
protection circuit Rectifier
Control circuit
Overcurrent
detector
Rectifier
and
smoothing
circuit
Detector
Photocoupler
S82J-15024j (150 W)
100 or 200 V
(selected au-
tomatically)
S82J-30024j
(300 W)
Parallel operation selector
100/200 V (selectable)
Note: Short-circuit
the input voltage terminals if
the
input is 100 to 120 V
AC. Keep the ter
-
minals
open if the input is 200 to 230 V
AC.
Fuse
(10 A)
Noise filter
Inrush current
protection circuit Rectifier
and
smoothing
circuit
Detector
Photocoupler
Overvoltage
detector
Photocoupler
Control
circuit
Overcurrent
detector
Rectifier and
smoothing circuit

S82J S82J
12
S82J-60024j
(600 W)
Parallel operation selector
100/200 V (selectable)
Note: Short-circuit
the input voltage terminals if
the
input is 100 to 120 V
AC. Keep the ter
-
minals
open if the input is 200 to 230 V
AC.
Fuse
20 A
Noise filter
Inrush current
protection circuit Rectifier
and
smoothing
circuit
Detector
Photocoupler
Photocoupler
Control
circuit
Overcurrent
detector
Fan
Overheat
detector Overvoltage
detector
Rectifier and
smoothing circuit

S82J S82J
13
Dimensions
Note: All
units are in millimeters unless otherwise indicated.
S82J-j1jj (10 W)
S82J-j2jj (25 W)
S82J-j5jj (50 W)
S82J-05024j(50 W)
Mounting
Holes
(Surface Screw Mounting)
Side Mounting
Bottom Mounting
3.5
90±1
97±1
65±0.5
5
82±0.5
Two, 3.5 dia.
3.5 dia.
78±0.5
6.5
M3.5 terminal
screw
3.5
28 35±1
50±0.5
17.5
15 Two, M3
For track mounting bracket
(4 mm deep max.)
12 max.
5
82±0.5
65±0.5
Two, M3
78±0.5
Two, M3
M3.5 terminal
screw Two, 3.5 dia.
Two, M3
For track mounting bracket
(4 mm deep max.)
124±1
3.5
97±1
65±0.5
28 40±1
3.5
112±0.5
3.5 dia.
12 max.
17.5
21.5 83±0.5
6.5
5116±0.5
6
Mounting
Holes
(Surface Screw Mounting)
Side Mounting
Bottom Mounting
112±0.5
Two, M3
Two, M3
65±0.5
116±0.5
Mounting
Holes
Side Mounting
Bottom Mounting
97±1
65±0.5
3.5
161±112
max.
M3.5 terminal
screw
5
6.5
22 127±0.5 Three, M3
For track mounting bracket
(4 mm deep max.)
150.5±0.5
153±0.5
3.5
10 28 40±1
Two, 3.5 dia.
3.5 dia.
7
153±0.5
Two, M3
150.5±0.5
65±0.5
Two, M3
20
20±0.5

S82J S82J
14
S82J-10024j(100 W)
M3.5 terminal
screw
170±112 max.
4.5
97±1
65±0.5
7
162±0.5
160±0.5
100±0.5
15
25±0.5
4.5
28±0.5
50±1
Three, M4
6.5
4.5 dia.
27.5
15
4.5 dia.
5162±0.5
65±0.5
Two, M3
Two, M3
160±0.5
Mounting
Holes
Side Mounting
Bottom Mounting
S82J-100jjjj (100 W)
S82J-15024j(150 W) 198 (see note)
188
180±0.5
4 max.
4.5
97
50
4.5
89±0.5
35±0.5
25±0.5
55±0.3100±0.5
27.5±0.3
7±0.3
178±0.5 3±0.25
3±0.25
8.1
9.5
M4 x 8
Three, M4
(6 mm max. deep)
4.5 dia.
4.5 dia.
Mounting holes
(on both sides)
Note: Top
terminal and connector models
are 188 mm wide.
15
Mounting Holes
(Surface Screw Mounting)
Side Mounting
Bottom Mounting
180±0.5
82±0.8
Two, M4
178±0.5
Two, M4
S82J-30024j(300 W) Eight, M4 holes
(depth: 8 max.
on both sides)
Four, M4 holes (depth: 8 max.)
Nine, M4 terminal screws
Side
4 max. (19)
Mounting
Holes
(Surface Screw Mounting)
Side Mounting
Bottom Mounting
150±0.5
50±0.5
Four, 4.5 dia.
150±0.5
100±0.5
Four, 4.5 dia.

S82J S82J
15
S82J-60024j(600 W)
Four, M4 holes (depth: 8 max. on one side)
Four, M4 holes
(depth: 8 max.)
Eight, M4 holes
(depth: 8 max.
on both sides)
Nine, M4 terminal screws
Mounting
Holes
(Surface Screw Mounting)
Side Mounting
Bottom Mounting
150±0.5
50±0.5
Four, 4.5 dia.
150±0.5
100±0.5
Four, 4.5 dia.
Dimensions with Provided Mounting Brackets
10-/25-/50-/100
(24 V)-W Models
Mounting Holes Using the Mounting Bracket
Attach the mounting bracket to the panel and
loosely tighten the two screws. Insert the projected
parts of the bracket (b) to the square holes of the
power supply (a). Then securely tighten the
screws.
Note:
The mounting screws are order separately
.
1.5 11
9
60
520
31.5
15
20.5
4.7
4.6
11
74
15±0.2
Mounting bracket
(b)
(b)
(a)
(a)
Power supply unit
Two, M3
60
20
4.6
Two,
3.5 dia.
t=1.0
Mounting bracket
120 MAX
Two, 5 dia.
30±0.5
110±0.5
100-
(5, 12, 15 V) and 150-W Models
Mounting with Brackets
Note:
The brackets are for front-mounting.
5 dia.
38
1.5
6.5
11
t=0.8
23.5

S82J S82J
16
300-W
Models
600-W Models
10 dia.
Two, 5 dia.
Note: To provide ventilation
space,
the body will shift
forward
by 21.6 mm
from
the
mounting surface.
Note: T
o provide ventilation space, the body will
shift
forward
by 23.6 mm from the mounting surface.
t=
1.6

S82J S82J
17
Accessories (Order Separately)
DIN Track Mounting Bracket
By
attaching the DIN T
rack Mounting Bracket to the Switching
Power Supply
, the Switching Power Supply can be mounted to a DIN-track with
ease.
Item S82Y-01N S82Y-03N S82Y-05N S82Y-10N
Applicable
supply
unit
S82J-j1jj S82J-j2jj S82J-j5jj S82J-100jjjj
S82J-15024j
Dimensions Power Supply Bracket
PFP-100N or
PFP-100N2
L1
L2
Two, 4.5-dia holes
DIN track
58
47
47 104
Dimensions: L1 113
mm
143 mm 163 mm 185 mm
L2
(see note)
1
14.8 mm 144.8 mm 164.8 mm 186.8 mm
Note: The
values given for L2 are for when the PFP-100N Mounting T
rack is used. If the PFP-100N2 is used, added 10.5 mm
to the values
given
for L2.
4.5
15 25 25 25 25 15
10 10
1,000
35±0.3 27 24
16
29.2
1 1.5
PFP-100N2
Twelve, 25 x 4.5
elliptic holes
Mounting Track
PFP-100N/PFP-50N
4.5
15 25 25 25 25
10 10
1,000 (500)
(see note)
7.3±0.15
35±0.3 27±0.15
1
15 (5)
(see note)
Note: The
values
shown in parentheses are for the PFP-50N.

S82J S82J
18
Ferrite Ring Core
S82Y-JC-T
Noise Filter
S82Y-JF3-N for 300-W Models
S82Y-JF6-N for 600-W Models
39±0.5
16
max.
A max.
B±1
Two, 4.8 dia.
(Mounting
holes) D±1
6.5
4Six, M4
6.5
C±0.5
16 max.
4
Nameplate 47±1
13±130±1
39±1
34±1
Model A B C D
S82Y-JF3-N 107 75 90 26
S82Y-JF6-N 117 85 100 30
Front-mounting Bracket for 100-W, 24-V (F-type)
S82Y-J10F
Mounting
Holes
Note:
The Front Mounting Bracket cannot be used for 5-, 12-, or 15-V S82J (100-, 150-W models).
Three, 4.5-dia. holes Three, M4

S82J S82J
19
Installation
10-/25-/50-/100-/150-W Models
Note: 10-/25-/50-/100
(24 V)-W models are available only as Front T
erminal Models.
5
6
1
3
2
+V
–V
AC
(L)
AC (N)
5
6
1
3
2
+V
–V
AC (L)
AC (N)
5
6
1
3
2
+V
–V
AC (L)
AC (N)
NC
9
Front
T
erminals Model
T
op T
erminals Model
Connector Model
GR
GR GR
Connectors
Connector
Connector on the PCB side
Housing Terminal
Input W
afer (Made by Molex) 5277-04A-RE
Housing (Made by Molex) 5196-04-RE
or 5196-04
T
erminal (Made by Molex) 5194T or
5194TL
Output T
ab header (Made by Nippon
AMP)
1-178140-5
Rise housing (Made by Nippon AMP)
1-178129-6
Rise contact (Made by Nippon
AMP)
1-175196-5 or 1-175218-5
Note:
The permissible current of the output connector is 8 A per pin.

S82J S82J
20
1. DC Output Terminals:
Connect the load lines to these terminals.
2.
Input T
erminals:
Connect the input lines to these terminals.
Note
: A fuse is inserted into the AC (L) side.
3. Ground Terminal (GR):
Connect a ground line to this terminal.
4. Input
V
oltage T
erminals:
Short-circuit the terminals if the input is 100 to 120 V
AC and open the terminals if the input is 200 to 230 V
AC
5. Output Indicator (DC ON):
Lights while a Direct Current (DC) output is ON.
6. Output V
oltage Adjuster (V
.ADJ):
It is possible to increase or decrease the output voltage by 10%.
7. Protection-ON
Alarm Indicator:
The red indicator will be lit if the overvoltage (for a 300-/600-W model) or overheat protection (for a
600-W
model) circuit is triggered. This indicator will also be lit when overcurrent (for a 600-W model) is detected.
8.
Parallel/Single Operation Selector:
Set the selector to P
ARALLEL if the Units are in parallel operation.
9. NC Terminals:
Leave unconnected.
600-W Models
+V
+V
*V
*V
5
6
1AC
(L)
AC (N) 2
4
3
GR
300-W Models
165 7
8
423
AC
(L)
AC (N)GR
8
Side view
7
Side view
Other manuals for S82J Series
3
Table of contents
Other Omron Power Supply manuals

Omron
Omron S8VT User manual

Omron
Omron S82K User manual

Omron
Omron S8VK-WA Series User manual

Omron
Omron ZEN-PA03024 User manual

Omron
Omron S8JX - User manual

Omron
Omron S8VK-G15-W User manual

Omron
Omron S8VS User manual

Omron
Omron S8FS-C Series User manual

Omron
Omron S8VS-24024A User manual

Omron
Omron S82J Series User manual

Omron
Omron S82K User manual

Omron
Omron S8AS User manual

Omron
Omron S82K User manual
![Omron CP1E-N[]S1 User manual Omron CP1E-N[]S1 User manual](/data/manuals/1j/0/1j0uf/sources/omron-cp1e-n-s1-power-supply-manual.jpg)
Omron
Omron CP1E-N[]S1 User manual

Omron
Omron S8VK-T Series User manual

Omron
Omron S82K-00305 User manual

Omron
Omron S8VS Series User manual

Omron
Omron S8T-DCBU-01 User manual

Omron
Omron S8T-DCBU-01 User manual

Omron
Omron S8FS-G Series User manual