Optex Fit Series User manual

ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL PORTUGUÊS
EN-1
FTN-ST Standard model with 2 PIRs
FTN-AM FTN-ST with anti-masking
No.59-2263-1
INSTALLATION INSTRUCTIONS
Compact outdoor
detector
Compact outdoor
detector
fit series
fit series
• Compact design
• 190° adjustable bracket
• Intelligent AND logic
• Digital anti-masking (AM model)
• Wall tamper (option)
CONTENTS
The check mark indicates recommendation. The nix sign indicates prohibition.
Warning
Caution
Failure to follow the instructions provided with this indication and improper handling may cause
death or serious injury.
Failure to follow the instructions provided with this indication and improper handling may cause
injury and/or property damage.
Warning Caution Caution
Do not remove the PCB.
ON
2 3 4
1
0.8 to 1.2 m
(2.6 to 3.9 ft.)
Parallel
Mounting height.
Tilt
Keep the detector parallel to the ground. Consider the direction of the intruder,
for the setting of the detection area.
Do not touch the PCB except for the
DIP switch.
1 INTRODUCTION
1-1 BEFORE INSTALLATION ...................................... 1
1-2 PARTS IDENTIFICATION...................................... 2
1-3 DETECTION AREA................................................ 2
2 INSTALLATION
2-1 INSTALLATION...................................................... 3
3 WALK TEST
3-1 WALK TEST ........................................................... 5
4 DIP SWITCH SETTING
4-1 LED ........................................................................ 5
4-2 ALARM OUTPUT ................................................... 5
4-3 PIR SENSITIVITY .................................................. 5
4-4 ANTI-MASKING...................................................... 6
5 OTHERS
5-1 WALL TAMPER (OPTION) CONNECTION ........... 6
5-2 EXAMPLE OF EOL WIRING.................................. 7
5-3 LED LIGHT PATTERN ........................................... 7
6 SPECIFICATIONS
6-1 SPECIFICATIONS.................................................. 8
6-2 DIMENSIONS......................................................... 8
WIRED MODEL
1INTRODUCTION
1-1
BEFORE INSTALLATION

ENGLISHFRANÇAISDEUTSCHITALIANOESPAÑOLPORTUGUÊS
EN-2
0
10
0
0
5
5
5
10
10
10
15
15
15
2345
1
1
1
2
3
4
5
(m)
(ft.)
(ft.)
(m)
2
4
5
3
-Optional accessories
Wall tamper (WRS-02)
Bracket
Sponge Fixture
Main unit
Main unit cover
Lens
Screw kit
Screw (3 × 20 mm)
0 5 10 15
0.8
0
(m)
1.0
1.2
2.6
0
(ft.)
3.3
3.9
10 2 3 4 5
(m)
(ft.)
0 5 10 15
0.8
0
(m)
1.0
1.2 10 2 3 4 5
(m)
2.6
0
(ft.)
3.3
3.9
(ft.)
Top view Side view
2 m detection length
5 m detection length
Adjustable range: 95°
(by 5° pitch)
Adjustable range: 95°
(by 5° pitch)
Sponge
Install the detector in a place where it is free from false alarm factors. For example:
• Objects moving in the wind
• Heat source
• Sunlight and reflection
1-2
PARTS IDENTIFICATION
1-3
DETECTION AREA

ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL PORTUGUÊS
EN-3
0
10
0
0
5
5
5
10
10
10
15
15
15
2345
1
1
1
2
3
4
5
(m)
(ft.)
(ft.)
(m)
2
4
5
3
-Optional accessories
Wall tamper (WRS-02)
Bracket
Sponge Fixture
Main unit
Main unit cover
Lens
Screw kit
Screw (3 × 20 mm)
0 5 10 15
0.8
0
(m)
1.0
1.2
2.6
0
(ft.)
3.3
3.9
10 2 3 4 5
(m)
(ft.)
0 5 10 15
0.8
0
(m)
1.0
1.2 10 2 3 4 5
(m)
2.6
0
(ft.)
3.3
3.9
(ft.)
Top view Side view
2 m detection length
5 m detection length
Adjustable range: 95°
(by 5° pitch)
Adjustable range: 95°
(by 5° pitch)
Sponge
Install the detector in a place where it is free from false alarm factors. For example:
• Objects moving in the wind
• Heat source
• Sunlight and reflection
1-2
PARTS IDENTIFICATION
1-3
DETECTION AREA
1
Open the main unit cover.
2
Remove the fixture.
3
Hold the top of the bracket
lifted and remove the main unit.
4
Note>>
• For wall tamper wiring (option), refer to 5-1.
5
1.
3.
2.
2.
1.
Bracket
Main unit
Put the wire extending from the wall through the
wiring hole in the bottom of the bracket, and
mount the bracket on the wall.
Pull the wire through the main unit.
Lift the top of the bracket slightly and mount the main
unit to the bracket.
83.5 mm
(3.29 inches)
Screw (3 × 20 mm)
Mounting height:
0.8 to 1.2 m
(2.6 to 3.9 ft.)
Screw (3 × 20 mm)
Sponge
Fixture
6
Wire terminal connections.
Notes>>
-Power cable length
The power cable should be limited to the following length.
FTN-ST FTN-AM
12 V 14 V 12 V 14 V
Power input (+)
Power input (-)
Alarm output
COM
Spare
Tamper
FTN-ST
+
-
AL
C
SP
TP
TP
(-)
Alarm output
COM
Trouble output
Tamper
FTN-AM
Power input (+)
Power input
+
-
AL
C
TR
TP
TP
• Anti-masking output is recognized as
TROUBLE.
• For EOL, refer to 5-2.
Unit: m (ft.)
Cable diameter
AWG22 (0.33 mm2)
AWG20 (0.52 mm2)
AWG18 (0.83 mm2)
340 (1120)
530 (1740)
850 (2790)
730 (2400)
1160 (3810)
1850 (6070)
290 (950)
450 (1480)
720 (2360)
620 (2030)
980 (3220)
1570 (5150)
2INSTALLATION
2-1
INSTALLATION

ENGLISHFRANÇAISDEUTSCHITALIANOESPAÑOLPORTUGUÊS
EN-4
8Determine the detection length. (2 m or 5 m)
Side view
0 5 10 15
2.6
0(ft.)
3.3
3.9
0.8
0
(m)
1.0
1.2
(ft.)
10 2 3 4 5
(m)
0 5 10 15
0.8
0
(m)
1.0
1.2
2.6
0(ft.)
3.3
3.9
10 2 3 4 5
(m)
(ft.)
Side view
5 m detection length (Factory default)
2 m detection length
If 2 m is required, rotate the lower
lens 180 degrees.
9Attach the main unit cover. 10 Perform walk test.
Note>>
• To prepare for walk test, check that DIP switch
1 (WALK TEST MODE) is set to “ON (TEST)”
before attaching main unit cover.
7Determine the horizontal detection angle
and attach the fixture.
1.
3.
2.
• When the unit is mounted on the
wall to look transversely,
choose the guide-mark
engraved.
• When the unit is mounted on the
corner to look ahead along the wall,
choose the guide-mark
located on the opposite
side of the wall.
Note>>
• Check that the fixture and
bracket engage correctly.
Note>>
Align the detection area
parallel to the wall to
reduce interference with
the wall.
Note>>
• To make adjustments, remove the fixture.
Note>>
• Do not remove the upper lens.

ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL PORTUGUÊS
EN-5
2
1
Set DIP switch 1 (LED) to “ON”.
ON
1234
Note>>
• The switch is set to “ON” by factory default.
DIP switch
Check that LED lights for 2 seconds
when the intended object is detected.
3
ON
1234
If the LED does not need to be turned on at all times,
set the DIP switch 1 (LED) to “OFF”.
DIP switch
N.O.
N.C.
STD
LOW
ON
1234
ON
1234
Do not touch the PCB except
for the DIP switch and the
terminal.
●: Factory default
DIP switch
1 LED
2 ALARM OUTPUT
3 PIR SENSITIVITY
4 ANTI-MASKING
ON
(Factory default)
LED OFF
LED ON
FunctionPosition
OFF
N.O.
N.C. output
N.O. output
FunctionPosition
N.C.
(Factory default)
STD
(Factory default)
Low sensitivity
Normal sensitivity
FunctionPosition
LOW
ON
OFF
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
ON
1234
3WALK TEST
4DIP SWITCH SETTING
3-1
WALK TEST
4-1
LED DIP switch 1 FTN-ST
FTN-AM
4-2
ALARM OUTPUT DIP switch 2 FTN-ST
FTN-AM
4-3
PIR SENSITIVITY DIP switch 3 FTN-ST
FTN-AM
Detected Not detected

ENGLISHFRANÇAISDEUTSCHITALIANOESPAÑOLPORTUGUÊS
EN-6
Note>>
-ANTI-MASKING function
ANTI-MASKING test mode
The trouble is output after 20 seconds.
Normal mode
The trouble is output after 3 minutes.
10 minutes1 minute
Teaching
When masking condition continues more than 3 minutes, TROUBLE will be generated.
TROUBLE is generated after 20 seconds under the anti-masking test mode.
Please close the main unit cover before turning on the power supply.
“Teaching mode” will begin immediately after the power is supplied.
Re-starting the power is necessary if the power has been applied prior to the closing.
Please be careful not to leave any object within 1 m from the unit.
• If a trouble is output (mal-detection of anti-masking) immediately after the operation has
started, set the DIP switch 4 (ANTI-MASKING) to “OFF” and then to “ON”, and close the cover.
ON
OFF
Connect the tamper lead as shown below when connecting a wall tamper (option).
CAL
+SP TP TP
Twist and swage
the wires.
Control panel
-Mounting position
Note>>
• Pull the wire through the bracket before
installing the wall tamper (option).
Bracket
Sponge
ON
(Factory default)
ANTI-MASKING OFF
ANTI-MASKING ON
FunctionPosition
OFF
4-4
ANTI-MASKING DIP switch 4 FTN-ST
FTN-AM
5OTHERS
5-1
WALL TAMPER (OPTION) CONNECTION
ON
1234
Wall tamper (option)
WRS-02

ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL PORTUGUÊS
EN-7
Note>>
-ANTI-MASKING function
ANTI-MASKING test mode
The trouble is output after 20 seconds.
Normal mode
The trouble is output after 3 minutes.
10 minutes1 minute
Teaching
When masking condition continues more than 3 minutes, TROUBLE will be generated.
TROUBLE is generated after 20 seconds under the anti-masking test mode.
Please close the main unit cover before turning on the power supply.
“Teaching mode” will begin immediately after the power is supplied.
Re-starting the power is necessary if the power has been applied prior to the closing.
Please be careful not to leave any object within 1 m from the unit.
• If a trouble is output (mal-detection of anti-masking) immediately after the operation has
started, set the DIP switch 4 (ANTI-MASKING) to “OFF” and then to “ON”, and close the cover.
ON
OFF
Connect the tamper lead as shown below when connecting a wall tamper (option).
CAL
+SP TP TP
Twist and swage
the wires.
Control panel
-Mounting position
Note>>
• Pull the wire through the bracket before
installing the wall tamper (option).
Bracket
Sponge
ON
(Factory default)
ANTI-MASKING OFF
ANTI-MASKING ON
FunctionPosition
OFF
4-4
ANTI-MASKING DIP switch 4 FTN-ST
FTN-AM
5OTHERS
5-1
WALL TAMPER (OPTION) CONNECTION
ON
1234
Wall tamper (option)
WRS-02
1234567
Alarm relay Trouble relay Tamper
Tamper-EOL-ResistanceAlarm-EOL-Resistance
Control panel Control panel
Positive (+)
terminal
Negative (-)
terminal
Alarm
(N.C./N.O.) COM Trouble (N.C.) Tamper (N.C.) Tamper (N.C.)
Since the alarm and trouble outputs share the COM terminal, the wire connection should be
made for the fit series detector according to the following diagram.
-Double EOL
-Triple EOL
1234567
Alarm relay Trouble relay Tamper
Tamper-EOL-ResistanceAlarm-EOL-Resistance
Control panel Control panel
Positive (+)
terminal
Negative (-)
terminal
Alarm
(N.C./N.O.) COM Trouble (N.C.) Tamper (N.C.) Tamper (N.C.)
1234567
Alarm relay Trouble relay Tamper
Tamper-EOL-
Resistance
Alarm-EOL-
Resistance
Control panel Control panel
Positive (+)
terminal
Negative (-)
terminal
Alarm
(N.C./N.O.) COM Trouble (N.C.) Tamper (N.C.) Tamper (N.C.)
Trouble-EOL-
Resistance
The following explains the LED light pattern.
Detector condition LED indicator
Warm-up
Note>>
• The LED blinks even if the DIP switch 1 (LED)
is set to “OFF”.
• The LED blinks even if the DIP switch 1 (LED)
is set to “OFF”.
Blinks for approx. 60 seconds.
Lights for 2 seconds.
Alarm
Masking detection
(FTN-AM only)
Note>>
Blinks 3 times and then repeats.
LED
Blink Light OFF
5-2
EXAMPLE OF EOL WIRING
5-3
LED LIGHT PATTERN

ENGLISHFRANÇAISDEUTSCHITALIANOESPAÑOLPORTUGUÊS
EN-8
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optex-europe.com
OPTEX SECURITY SAS (France)
URL: http://www.optex-security.com
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.com.pl OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com
Copyright (C) 2016 OPTEX CO.,LTD.
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com
OPTEX (Thailand) CO., LTD. (Thailand)
URL: http://www.optex.net/th/th
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex.net/in/en/sec
OPTEX TECHNOLOGIES B.V.(The Netherlands)
URL: http://www.optex.eu
Note>>
• These units are designed to detect an intruder and activate an alarm control panel. Being only a part of
a complete system, we cannot accept responsibility for any damages or other consequences resulting
from an intrusion.
Unit: mm (inch)
35
(1.38) 42.5
(1.67)
155 (6.10)
* Specifications and design are subject to change without prior notice.
Model
Detection method
PIR coverage
Detection length limit
Detectable speed
Sensitivity
Operation voltage
Current draw
Alarm period
Warm-up period
Alarm output
Trouble output
Tamper output
LED indicator
Operation temperature
Environment humidity
Weatherproof
Mounting
Mounting height
Weight
Accessories
FTN-AMFTN-ST
Passive infrared
5 × 1 m (16.4 × 3.3 ft.)
2 m, 5 m (6.6 ft., 16.4 ft.)
0.3 to 1.5 m/s (1 to 4.9 ft./s)
2.0°C (at 0.6 m/s) (3.6°F (at 2 ft./s))
9.5 to 18 VDC
2.0 ±1.0 sec.
Approx. 60 sec. (LED blinks)
-20°C to +60°C (-4°F to +140°F)
N.C. 28 VDC 0.1 A (max.)
open when the cover is removed
95% max.
IP55
Wall (Outdoor, Indoor)
0.8 to 1.2 m (2.6 to 3.9 ft.)
100 g (3.5 oz.)
17 mA (max.)
(at 12 VDC)
-
20 mA (max.)
(at 12 VDC)
N.C. 28 VDC 0.1 A (max.)
N.C./N.O. Selectable 28 VDC 0.1 A (max.)
Light/Blink: Warm-up, alarm,
masking detection (FTN-AM only)
Screw (3 × 20 mm) × 2
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net
6SPECIFICATIONS
6-1
SPECIFICATIONS
6-2
DIMENSIONS
■ EU contact information
Manufacturer:
OPTEX CO., LTD.
5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN
Authorised representative in Europe:
OPTEX (EUROPE) LTD. / EMEA HEADQUARTERS
Marandaz House 1 Cordwallis Park, Clivemont Road,
Maidenhead, Berkshire, SL6 7BU U.K.
Other manuals for Fit Series
1
This manual suits for next models
2
Table of contents
Other Optex Security Sensor manuals

Optex
Optex ELITE T User manual

Optex
Optex AX100 User manual

Optex
Optex AX-70TN User manual

Optex
Optex MX-40QZ Quick start guide

Optex
Optex VX-402 User manual

Optex
Optex inSight INS-HX-80N User manual

Optex
Optex VX Infinity Series User manual

Optex
Optex AP-20NB(C) User manual

Optex
Optex QX Infinity Series User manual

Optex
Optex HX-80N User manual