59-xxxx-0 2102-18
Quick Guide
Full information is available at
https://navi.optex.net/manual/50426
• This “Quick Guide” is the part of the entire installation instructions
that guides the installation procedures for installers.
Get the full information of the installation instructions in the web site.
If you need a guide to the operation of the whole system, please
consult your installer of the entire system.
•
•
Warning
- 1 -
Caution
Prohibition
Recommendation
Failure to follow the instructions provided with this indication
and improper handling may cause death or serious injury.
Failure to follow the instructions provided with this indication
and improper handling may cause injury and/or property
damage.
NOTE
Special attention is
required to the
section of this symbol.
1-2. Install a mounting plate
1-1. Disassemble
Hook the fall prevent wire.
Camera and PIR detector
Mounting height
Tilt
123
1
2
3
4
5
6
- Parts identification
- Accessories
- Manufacture’ s statement
- Detection area
- Specifications
- Dimensions
- Compliance
- How to reset to the factory default
Before installation
Others
<< Contents >>
- Parts identification
- Accessories
4 x 20 mm
Mounting screws
T20 Torx wrench
Waterproof cap
for LAN connection
- Manufacture’ s statement
Before installation
PIR detector
Bracket angle adjusting screw
PIR cover
Camera unit Camera angle adjusting screw
Back cover
1Installation
Step
IP camera settings
CHeKT settings
Page
1
2
3
4
Step
Mounting plate
Enable
Disable
Detection area settings and walk test
Installation
Registration InSight to CHeKT portal site
DHCP
IP address settings
Camera angle settings
System check
PIR area masking strips
(Both side “e” are attached
to the lens in the factory)
Section
“e”
2.2 m (7 3 ) to 2.7 m (8 11 )
Caution
Do not use the vertical angle adjustment of
the main unit other than adjusting the
detection area surface to be parallel to the
ground inclination.
The display of the detection area helps to set the area.
- 2 -
4-1. PIR area direction
Parallel Adjusting the detection range
Vertical: 0°to -20°
Horizontal: ±95°
1-4. Assembling
1 2
1-3. Wiring
PoE LAN cable
DC power cable
12 V DC power for camera and PIR
The connector can be fixed inside
the main body with double-sided tape.
NOTE
2IP address settings
Step
3Registration InSight to CHeKT portal
Step
The default network type of InSight is dynamic. If you do not
have a DHCP server, access the following IP address.
Change the InSight network type to Static and set the
IP address;
Initial address: Refer to the label on the InSight
User name: root
Default password: OPTEX
Refer to the “IP Camera Setting Manual”
in more detail.
The default network type of InSight is dynamic. If you have a DHCP server,
it will automatically set the IP address.
1. Setup your CHeKT Dealer Portal:
2. Before getting started with CHeKT, you will need
access to a CHeKT dealer web portal.
Access to this portal allows you to install and manage
the InSight series. If you do not have an account, please
request a dealer account by visiting:
www.chekt.com/registration
Refer to the “https://support.chekt.com” for more detail.
Detection area settings and walk test
4
Step
Put the main body back on mounting plate.
Cut the rubber and put the LAN cable into
(a), then (b) will be assembled to (a) tightly.
As a final step, (c) need to be assembled
to (b) without making any space.
Waterproof cap
for LAN connection
Caution
Do not pinch the cable when restoring
the PIR detector.
1
2
Raise up
Pull back
Remove the Back cover by hand. Adjust PIR area direction
12Settings on the InSight web
It is possible to refer the location of the detection area following procedure.
SETUP -> PIR DETECTOR -> PIR area viewer
In this step, do not change the camera tilt angle on InSight web settings.
NOTE
4-2. Detection area masking 4-3. DIP switch settings 4-4. Close the PIR cover
Details for
4-2. and 4-3
CHeKT settings
IP camera settings
8-pin I/O cable
Tamper
Alarm
Power
+- SP N/A COM AL TP TP
Pink
Orange
Yellow
Brown
Green
Purple
Black
Red
Do not connect to the N/A terminal.
Caution
It can be also used as a back up for POE
- 3 -
4-5. Walk test
1
2
Default
Camera angle settings
5
Step
If the angle of the camera is adjusted up or down, the detection area display
of the detector on the screen will be different from the actual one.
Adjust the display on the web. See the IP camera manual.
System check
6
Step
Check the image at the time of detection on the monitoring portal.
Camera angle adjustment
Loosen the screw to adjust camera angle
Angle can be adjusted with either left or right screw.
Settings on the InSight web
Replace the Back cover by hand.
Replace the back cover
1Turn LED back ON, if it was turned OFF (DIP switch No. 1, Default ON).
Walk around the detection area to make sure it is set as intended.
If necessary, turn LED OFF again.
Fix the cover with the cover lock screw included in the housing,
after completion as necessary.
2
For the walk test, walk at least 1.0 m (3’ 3” ) away from the detector.
Caution
3
4
NOTE
For confirmation, the LED will light up according to the alarm output for 3 minutes
after the detector cover is installed again in any setting.
Conduct a walk test at least once a year.
20°min.
35°max.
30°
1 2
3
Unit: mm (inch)
EU contact information
Manufacturer:
OPTEX CO., LTD.
5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN
Authorized representative in Europe:
OPTEX (EUROPE) LTD./EMEA HEADQUARTERS
Unit 13, Cordwallis Park, Clivemont Road,
Maidenhead, Berkshire, SL6 7BU U.K.
OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com
OPTEX SECURITY B.V.
(The Netherlands)
www.optex-europe.com/nl
OPTEX SECURITY SAS (France)
www.optex-europe.com/fr
OPTEX SECURITY Sp.z o.o. (Poland)
www.optex-europe.com/pl
OPTEX PINNACLE INDIA,
PVT., LTD. (India)
www.optexpinnacle.com
OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
www.optex.co.th
Copyright (C) 2021 OPTEX CO.,LTD.
OPTEX CO., LTD. (JAPAN)
www.optex.net
- 4 -
- Detection area
Others - Specifications
- Dimensions
- How to reset to the factory default
FCC notification
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Personal Information
This product is equipped with the function to produce moving image of the designated area and
its surrounding, but not equipped with the function to store or register such image.
Prior to the installation of this product, the compliance to local laws and regulations needs to be
confirmed by the user of this product for the lawful installation and use of this product, and
signage and notification when using this product. User of this product is deemed to be
responsible for the compliance of any laws and regulations relating to personal information,
privacy protection and rights of portrait upon use of this product. Image taken by this product is
required to be treated appropriately under the responsibility of the user of this product.
Installation of this product, producing image, monitoring, recording with camera and handling of
personal information or data shall all be performed under discretion and responsibility of user of
this product, and OPTEX shall not be held liable for any dispute between a user and a third party.
- Compliance
12
3
Follow the steps below to perform a factory reset (for example, forget the password).
The IP address, ID, password and camera settings are initialized.
Caution
Do not pinch the cable when restoring the PIR detector.
Cable
Factory reset switch
About distribution of source code for open source software
This product includes open source software(” OSS”)
distributed under OSS License. In
compliance with the OSS Licenses such as GPL (GNU GENERAL PUBLIC LICENSE), LGPL
(GNU LESSERGENERAL PUBLIC LICENSE), and/or others included, we are making the source
code of the OSS available, at the actual cost, to our customer upon his/her request. The source
code corresponding to OSS included in this product will be provided in a prescribed manner for
at least than three(3) years after the date of purchase. Please note that the OSS is provided
without warranty of any kind.
Press to reset for 5 seconds.
• These units are designed to detect an intruder and activate an alarm control panel.
Being only a part of a complete system, we cannot accept responsibility for any
damages or other consequences resulting from an intrusion.
• Specifications and designs are subject to change without prior notice.
INS-QXI-ST
Passive infrared
12.0 m (40') 75°wide
32 zones
0.3 to 2.0 m/s (1' to 6'7"/s)
2.0℃( 3.6°F) at 0.6 m/s
PoE (IEEE 802.3af compliant)
Mini-jack 12 V DC 420 mA max.
Terminal 9.5 to 16 V DC/ 20 mA max. at 12 V DC
2.0 ± 0.5 s
Approx. 60 s (LED blinks)
N.C/N.O. switchable, 28 V DC 0.1 A max.
N.C. 28 V DC 0.1 A max.
Open when the cover is opened
[1] Warm-up [2] Alarm [3] Walk test end
1/2.8” CMOS
H: 114° V: 61°
Color: 0.02 lux. 0 lux. with IR
Visible up to 12 m
Day & Night Automatic/Manual switching
H.264, H.265, MJPEG
1080/ 30 fps, D1 (704 x 480 or 704 x 576)
IPv4: TCP/IP, UDP, RTP(UDP/TCP), RTSP, NTP, HTTP,
HTTPS, SSL, DHCP, SNMPv1/v2/v3(MIB-2), ONVIF
HTTPS(SSL), IP filtering, 802.1x, Digest authentication (ID/PW)
-30℃to +50℃(-22°F to +122°F)
95% max.
IP 54
Wall (Outdoor, Indoor)/Gang box
2.2 to 2.7 m (7' 3" to 8'11")
xxx g (x.xx oz)
[1] Mounting screw (4 x 20 mm) x 2
[2] T20 Torx wrench x 1
[3] Area masking strips x 1
[4] Waterproof cap for LAN connector x 1
Model
Detection method
PIR coverage
PIR zones
Detectable speed
Sensitivity
Power input
Alarm period
Warm-up period
Alarm output
Tamper output
LED indicator
Image sensor
Viewing angle
Minimum illumination
IR illumination
Night vision
Image compression
Resolution/ frame rate
Network protocol
Security
Operation temperature
Environment humidity
International protection
Mounting
Mounting height
Weight
Accessories
Top view
Side view
30 35
25
0
10
912 m
4
7.5 m
2
0
2
510 20
15
3
4
6
40 ft.
5
15
25 ft.
7.5 m
5
10
15
25 ft.
0
0
20
6
6 20
35
30
25
9
20
6
2.2 m
0
1510
5
0
3 12 m
40 ft.
2.7 m
b
c
d
e
e
fb
c
d
f
Area on both sides are masked with the area strips by default.
e
a
Caution Pet alley can not be set because the camera performance is not fully exhibited.
Do not slide the main unit of the detector.
Do not raise the mirror of the detector.
•
•
PIR
Camera
7’ 3”
8’ 11”
214 (8.43)
84 (3.31) 209 (8.23)
140 (5.51)
83.5 (3.29)

Other manuals for InSight INS-QXI-ST

2

Other Optex Security Sensor manuals

Optex FTN-RRHW User manual

Optex

Optex FTN-RRHW User manual

Optex Smart Line SL-350 QNR User manual

Optex

Optex Smart Line SL-350 QNR User manual

Optex CDX-AM Quick start guide

Optex

Optex CDX-AM Quick start guide

Optex QX Infinity Series User manual

Optex

Optex QX Infinity Series User manual

Optex Fit Series User manual

Optex

Optex Fit Series User manual

Optex RXC-DT-X5 User manual

Optex

Optex RXC-DT-X5 User manual

Optex RLS-50100V User manual

Optex

Optex RLS-50100V User manual

Optex inSight INS-HX-80N User manual

Optex

Optex inSight INS-HX-80N User manual

Optex HX-40 User manual

Optex

Optex HX-40 User manual

Optex OVS-6000 User manual

Optex

Optex OVS-6000 User manual

Optex FASTUS CD22-15 Series User manual

Optex

Optex FASTUS CD22-15 Series User manual

Optex SL-100 TNR User manual

Optex

Optex SL-100 TNR User manual

Optex REDSCAN Series User manual

Optex

Optex REDSCAN Series User manual

Optex SL-100 TNR User manual

Optex

Optex SL-100 TNR User manual

Optex AX-100TFR Series User manual

Optex

Optex AX-100TFR Series User manual

Optex AX-70TN User manual

Optex

Optex AX-70TN User manual

Optex OML-ST User manual

Optex

Optex OML-ST User manual

Optex RXC-DT-X5 User manual

Optex

Optex RXC-DT-X5 User manual

Optex REDWALL-V Guide

Optex

Optex REDWALL-V Guide

Optex RXC-RST User manual

Optex

Optex RXC-RST User manual

Optex URX-P01 User manual

Optex

Optex URX-P01 User manual

Optex REDBEAM Series Quick start guide

Optex

Optex REDBEAM Series Quick start guide

Optex AX-350DH MK III User manual

Optex

Optex AX-350DH MK III User manual

Optex FlipX Series User manual

Optex

Optex FlipX Series User manual

Popular Security Sensor manuals by other brands

CLAS AC 5028 manual

CLAS

CLAS AC 5028 manual

DFA SqwidNET Visio Tamper installation guide

DFA

DFA SqwidNET Visio Tamper installation guide

MiLi PURE II user guide

MiLi

MiLi PURE II user guide

Ortus PIR-R Operation manual

Ortus

Ortus PIR-R Operation manual

KeCheng KC-090 user manual

KeCheng

KeCheng KC-090 user manual

KRATOS SAFETY Gravity Series manual

KRATOS SAFETY

KRATOS SAFETY Gravity Series manual

Schulz TES013 instruction manual

Schulz

Schulz TES013 instruction manual

Vision ZP3113IN-8 Installation & operation manual

Vision

Vision ZP3113IN-8 Installation & operation manual

Sygonix SY-4755358 operating instructions

Sygonix

Sygonix SY-4755358 operating instructions

Honeywell Filtrex TC844A1007 installation instructions

Honeywell

Honeywell Filtrex TC844A1007 installation instructions

U-Prox PIR Combi user manual

U-Prox

U-Prox PIR Combi user manual

DSC AMB-600 installation instructions

DSC

DSC AMB-600 installation instructions

Schwaiger ZHS21 user manual

Schwaiger

Schwaiger ZHS21 user manual

Politec ALES 60 quick start guide

Politec

Politec ALES 60 quick start guide

Rielta OCHRANA ORLAN installation guide

Rielta

Rielta OCHRANA ORLAN installation guide

See Water Radar Pro RPRO-2000 Installation and operation manual

See Water

See Water Radar Pro RPRO-2000 Installation and operation manual

Grace 850 Operation and maintenance

Grace

Grace 850 Operation and maintenance

Texecom Prestige Orbit QD installation manual

Texecom

Texecom Prestige Orbit QD installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.