The is a managed industrial Ethernet switch with eight
10/100/1000Base-T(X) ports and four 100/1000Base-X SFP ports. The
eight RJ45 Ethernet ports are P.S.E-enabled, which can transmit electrical
power up to 30 watts per port. With Layer-3 support for higher network
performance on large-scale LANs, the switch is optimized to transmit data
as fast as Layer-2 switches. With complete support of Ethernet redundancy
protocols, O-Ring (recovery time < 30ms for over 250 connected devices)
and MSTP (RSTP/STP compatible) can protect your mission-critical
applications from network interruptions or temporary malfunctions. With a
wide operating temperature from -40 C to 70 C, the device can be
managed centralized via ORing’s proprietary Open-Vision platform as
well as via Web-based interfaces, Telnet and console (CLI).
IGPS-R9084GP
oo also
Therefore,
the switch is one of the most reliable choice for highly-managed and fiber
Ethernet applications.
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient:
Reduced Air Flow:
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Safety & Warnings
Dimension
Panel Layouts
1. Reset button
2. PWR status LED
3. PWR1 LED
4. PWR2 LED
5. R.M. status LED
6. Ring status LED
7. Faulty relay indicator
8. Console port
9. Link/action LED for Gigabit PoE
LAN ports (Odd PoE ports)
10. Gigabit Ethernet ports
11. Link/action LED for Gigabit PoE
LAN ports (Even PoE ports)
12. SFP port
13. Link/Act LED for SFP port
14. PoE LED for LAN ports
Package Contents
Front View
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
Installation
IGPS-R9084GP
QIG IGPS-R9084GP
1907-2-29-IGPSR9084GP-1.0
Mechanical Loading:
Circuit Overloading:
Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Consideration should be given to the connection of the equipment
to the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
GIGABIT
INDUSTRIAL
SWITCH
PoE
Industrial Managed PoE Gigabit Switch
Step 1:
Step 2:
Slant the switch and screw the Din-rail kit onto the back of the switch, right in
the middle of the back panel.
Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch
clicks into the rail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the two pieces of wall-mount kits onto both ends of the rear panel of the
switch. A total of six screws are required, as shown below.
Use the switch, with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Insert four screw heads through the large parts of the keyhole-shaped apertures,
and then slide the switch downwards. Tighten the four screws for added stability.
Wall-mounting
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch
uses CAT 3, 4, 5, 5e UTP cables to connect to any other network devices (PCs,
servers, switches, routers, or hubs). Please refer to the following table for cable
specifications.
Cable Types and Specifications:
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (3 28 ft) RJ-45
33.0
145.5
87.0
48.0
17.5
94.0
124.0
48.0
58.0
7.50
R2.5
R3.95
80.50
62.0
87.9
IGPS-R9084GP
10.9
15.0
70.5
154.0
96.4
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
IGPS-R9084GP
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
9
10
8
2
3
4
5
6
7
1
14
13
12
11
Top PanelRear View
12
PWR-1PWR-2
1A@24V
DC50-57V
V2-V2+ V1-V1+
Fault
1
1. Wall-mount screw holes
2. Din-rail screw holes
2
1. Terminal blocks: PWR1, PWR2
, Relay
2. Ground wire.
1
IGPS-R9084GP
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
QIG Quick Installation Guide
PRINTED ON RECYCLED PAPER
Version 1.0
Quick Installation Guide
Power
Redundant Input power
Power consumption(Typ.)
(PoE output not included) 19W(PoEoutputnotincluded)
Overload current protection Present
Physical Characteristic
Enclosure IP-30
Dimension(WxDxH) 96.4x145.5x154mm(3.8x5.73x6.06inch)
RS-232 Serial Console Port
Switch Properties
Switch latency: 7 us
Switch bandwidth: 24Gbps
Max. Number of Available VLANs: 256
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
Security Features
Device Binding
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
Single 802.1x and Multiple 802.1x
MAC-based authentication
QoS assignment
Guest VLAN
MACaddresslimit
TACACS+
VLAN (802.1Q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Web and CLI authentication and authorization
Authorization (15 levels)
IP source guard
Https / SSH enhance network security
Software Features
Hardware routing, RIP and static routing
IEEE 1588v2 clock synchronization
IEEE 802.1D Bridge, auto MAC address learning/aging and MAC address (static)
Multiple Registration Protocol (MRP)
RSTP/MSTP (IEEE 802.1w/s)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging
Voice VLAN
IGMP v2/v3 Snooping
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server/Client/snooping
DHCP Relay
Modbus TCP
DNS client proxy
ARP inspection
SMTP Client
Network Redundancy O-Ring, Open-Ring, O-Chain, MRP, MSTP (RSTP/STP compatible)
RS-232 in RJ45 connector with console cable. Baud rate setting: 115200bps, 8, N, 1
Weig ht (g) 1560 g
Jumbo frame Up to 9.6K Bytes
Weig ht (g) 710 g 740 g722 g 735 g 735 g 740 g
Environmental
-40to85 C(-40to185F)
oo
Storage Temperature
-40to70 C(-40to158F)
oo
Operating Temperature
5% to 95% Non-condensingOperating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class AEMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27Shock
IEC60068-2-32
IEC60068-2-6Vibration
EN60950-1
Safety
Free Fall
Warranty
5 years
ORing Industrial Networking Corp.
Copyright© 2014 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
Fault Contact
Relay Relayoutputtocarrycapacityof1Aat24VDC
Reverse Polarity Protection
Present
QIG
GIGABIT
INDUSTRIAL
SWITCH
PoE
Industrial Managed PoE Gigabit Switch
1000Base-T P.S.E. RJ-45 Port
Pin No.
BI_DA+ with PoE Power input +
#1
Assignments
#2
#3
#4
BI_DA- with PoE Power input +
BI_DB+ with PoE Power input -
BI_DC+
BI_DC-
#5
#6
#7
#8
BI_DB- with PoE Power input -
BI_DD+
BI_DD-
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X p ort
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3RD+(receive)TD+(transmit)
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment RS-232 with DB9 (female) pin
assig nment (RJ45-D B9 cabl e) RJ45 pin assign ment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5 GND PIN#5 GND PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
STEP 1:
STEP 2:
PWR-1PWR-2
1A@24V
V2-V2+ V1-V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_ DA+ B I_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5BI_DC-BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD - BI_DC-
Resetting
To reboot the switch, press the button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the button for 5 seconds.
Reset
Reset
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are ). After logging in, you should
see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
admin
Follow the steps to set up the switch:
Specifications
ORing Switch Model
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3ab for 1000Base-T
IEEE 802.z for 1000Base-X
IEEE 802.3x for Flow control
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
IEEE802.3atPoEspecification(upto30WattsperportforP.S.E.)
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.1p for COS (Class of service)
10/100/1000Base-T(X) with
P.S.E.PortsinRJ45Auto
MDI/MDIX
MAC Table 8K
Priority Queues 8
Processing Store-and-Forward
8
IGPS-R9084GP
Dual DC inputs. 50-57VDC on 6-pin terminal block
100/1000Base-X with SFP port 4
10/100Base-T(X) P.S.E. RJ-45 Port
Pin No.
TD+ with PoE Power input +
#1
Assignments
#2
#3
#6
TD- with PoE Power input +
RD+ with PoE Power input -
RD- with PoE Power input -
LED Color Status Description
PWR Gree n On DC power on
PWR 1 Green On DC power module 1 activated
PWR 2 Green On DC power module 2 activated
R.M Green On Ring Master
On R ing enabled
Ring Green Blinking Ring structure is broken (i.e. part of the ring is
disconnected)
Fault Amber On Faulty relay(power failure or port disconnected)
PoE Gree n On Power supplied over Ethernet
10/100/1000Base-T(X) Gigabit PoE Ether net ports
On Port l ink at 100 0Mbps
Green Blinking Data transmitted
On Port l ink at 10/100Mbps
LNK/ACT
with speed Amber
Blinking Data transmitted
SFP ports
On Port l ink up
LNK/ACT Green
Blinking Data transmitted
IGPS-R9084GP
IGPS-R9084GP

Other ORiNG Switch manuals

ORiNG IPS-2042 Series User manual

ORiNG

ORiNG IPS-2042 Series User manual

ORiNG IES-2050A User manual

ORiNG

ORiNG IES-2050A User manual

ORiNG IPS-3082GC-AT User manual

ORiNG

ORiNG IPS-3082GC-AT User manual

ORiNG IGS-9844GPFX Series User manual

ORiNG

ORiNG IGS-9844GPFX Series User manual

ORiNG IGS-P9164 Series User manual

ORiNG

ORiNG IGS-P9164 Series User manual

ORiNG RGS-7244GP User manual

ORiNG

ORiNG RGS-7244GP User manual

ORiNG IGS-1042GPA User manual

ORiNG

ORiNG IGS-1042GPA User manual

ORiNG IPS-2042TX Series User manual

ORiNG

ORiNG IPS-2042TX Series User manual

ORiNG IGS-3044GC User manual

ORiNG

ORiNG IGS-3044GC User manual

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG IGPS-1082GP Series User manual

ORiNG

ORiNG IGPS-1082GP Series User manual

ORiNG TPS-1080-M12 User manual

ORiNG

ORiNG TPS-1080-M12 User manual

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG IES-3160 User manual

ORiNG

ORiNG IES-3160 User manual

ORiNG IGS-9122GPM User manual

ORiNG

ORiNG IGS-9122GPM User manual

ORiNG TGPS-9084GT-M12 User manual

ORiNG

ORiNG TGPS-9084GT-M12 User manual

ORiNG TRGPS-9084GT-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084GT-M12X-BP2-MV User manual

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG TPS-141TX-M12 Series User manual

ORiNG

ORiNG TPS-141TX-M12 Series User manual

ORiNG IPS-3082GC-24V User manual

ORiNG

ORiNG IPS-3082GC-24V User manual

ORiNG IES-3240 User manual

ORiNG

ORiNG IES-3240 User manual

ORiNG IGS-1050A User manual

ORiNG

ORiNG IGS-1050A User manual

ORiNG IGPS-9080-24V User manual

ORiNG

ORiNG IGPS-9080-24V User manual

ORiNG IES-180-L User manual

ORiNG

ORiNG IES-180-L User manual

Popular Switch manuals by other brands

hager TS 204 User instruction

hager

hager TS 204 User instruction

Omron ER6022 datasheet

Omron

Omron ER6022 datasheet

SMC Networks TigerStack II SMC8926EM Specifications

SMC Networks

SMC Networks TigerStack II SMC8926EM Specifications

Marmitek Connect 421 UHD user manual

Marmitek

Marmitek Connect 421 UHD user manual

Allied Telesis AlliedWare Plus x220 Series installation guide

Allied Telesis

Allied Telesis AlliedWare Plus x220 Series installation guide

Linksys USB2HUB4 - ProConnect USB Hub Specifications

Linksys

Linksys USB2HUB4 - ProConnect USB Hub Specifications

Luxlink OSM-6222-XY operating instructions

Luxlink

Luxlink OSM-6222-XY operating instructions

Juniper EX4300 manual

Juniper

Juniper EX4300 manual

Network Instruments Matrix user guide

Network Instruments

Network Instruments Matrix user guide

Interlogix NS4702-24P-4X Command guide

Interlogix

Interlogix NS4702-24P-4X Command guide

Sony SB-V60S - Auto Switcher AV Selector operating instructions

Sony

Sony SB-V60S - Auto Switcher AV Selector operating instructions

Alpha Technologies Cordex CXRF 48-3.6kW Installation and operation manual

Alpha Technologies

Alpha Technologies Cordex CXRF 48-3.6kW Installation and operation manual

Midas HUB4 quick start guide

Midas

Midas HUB4 quick start guide

Sun Microsystems N2000 Series Quick installation

Sun Microsystems

Sun Microsystems N2000 Series Quick installation

SICK T4000 Standard operating instructions

SICK

SICK T4000 Standard operating instructions

Magnetrol C29 Installation and operating manual

Magnetrol

Magnetrol C29 Installation and operating manual

HP FlexNetwork 5130 HI series Command reference

HP

HP FlexNetwork 5130 HI series Command reference

peplink PEPWAVE SD Switch Series user manual

peplink

peplink PEPWAVE SD Switch Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.