manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ORiNG
  6. •
  7. Switch
  8. •
  9. ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

Quick Installation Guide
Version 1.1
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
Q I G
ORing's Transporter series managed Ethernet switches are designed for
TM
industrial applications such as rolling stock, vehicle, and railway. The
TRGPS-9084TG-M12X-BP2-MV, which is compliant with the EN50155
standard, is a managed 10G/2.5G Redundant Ring Ethernet switch with
8x10/100/1000Base-T(X) P.S.E. ports and 4x10GBase-T ports which is
specifically designed for the toughest and fully compliant with EN50155
requirement. The switch support Ethernet Redundancy protocol, O-Ring
(recovery time < 30ms over 250 units of connection), O-Chain and MSTP
(RSTP/STP compatible) can protect your mission-critical applications from
network interruptions or temporary malfunctions with its fast recovery
tech nology. It is specifical ly designed for the toughest industrial
environments. EN50155 Ethernet switchTRGPS-9084TG-M12X-BP2-MV
uses M12 connectors to ensure tight, robust connections, and guarantee
reliable operation against environmental disturbances, such as vibration
and shock. also support Power overTRGPS-9084TG-M12X-BP2-MV
Ethernet, a system to transmit electrical power up to 30 watts, along with
data, to remote devices over standard twisted-pair cable in an Ethernet
n e t w o r k . E a c h s w i t c h h a sT R G P S - 9 0 8 4 T G - M 1 2 X - B P 2 - M V
8x10/100/1000Base-T(X) P.S.E. (Power Sourcing Equipment) ports. P.S.E.
is a device (switch or hub for instance) that will provide power in a PoE
connection. And support wide operating temperature from -40 C to 75 C.
o o
TRGPS-9084TG-M12X-BP2-MV can also be managed centralized and
convenient by Open-Vision, Except the Web-based interface, Telnet and
console (CLI) configuration. Therefore, the switch is one of the most
reliable choice for highly-managed and Ethernet application.
Package Contents
Installation
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative
for assistance.
Preparation
Before you begin installing the device, make sure you have all of the
package contents available and a PC with Microsoft Internet Explorer 6.0 or
later, for using web-based system management tools.
Elevated Operating Ambient: If installed in a closed environment, make sure
the operating ambient temperature is compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Safety & Warnings
For pin assignments of power, console and relay output ports, please refer to the following tables.
Contents
TRGPS-9084TG-M12X-BP2-MV
Pictures Number
1
Dimension
Panel Layouts
Front View
1. Reset button
2. Power status LED
3. R.M. status LED
4. Ring status LED
5. Fault LED
6. Power connector
7. Relay output port
8. Console port
Wiring
Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the grounding pin on the power connector to the grounding
surface prior to connecting devices.
Power port pinouts
The device supports one set of power supply and uses the M12 S-coded
4-pin male connector on the front panel for power input.
Step 1: Insert a power cable to the power connector on the device.
Step 2: Rotate the outer ring of the cable connector until a snug fit is
achieved. Make sure the connection is tight.
Relay output port pinouts
Relay N.C.
3A@24VDC
Network Connection
The switch has eight 10/100/1000Base-T(X) PoE and four 10/100/1000Base-T(X) non-PoE
Ethernet ports in the form of M12 connector. Depending on the link type, the switch uses CAT 3, 4,
5,5e UTP cables to connect to network devices (PCs, servers, switches, routers, or hubs). Please
refer to the following table for cable specifications.
TRGPS-9084TG-M12X-BP2-MV
TRGPS-9084TG-M12X-BP2-MV 1907-200-Q9084TX2M1-FX021
S w i tc h
E N 5 0 1 5 5
EN50155 Rack-mount managed
10G/2.5G PoE Ethernet switch
I N D U S T R I A L
The switch uses the M12 A-coded 5-pin female connector
on the front panel for relay output. Use a cable with an M12
A-coded 5-pin male connector to connect the relay. The
relay contacts will detect user-configured events and form
an close circuit when an event is triggered.
Cable
Type
Max. Length
Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft)
8-pin female M12
X-coding connector
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft)
8-pin female M12
X-coding connector
1000BASE-T Cat. 5/Cat. 5e 100-ohm UTP UTP 100 m (328 ft)
8-pin female M12
X-coding connector
For pin assignments of the Ethernet ports, please refer to the following tables.
Rack-mounted kit (L&R) 1
Console port pinouts
RSVD
RXD
RS-23 2, 115200bps, 8, N , 1
GND
TXD
N.C.
N.C
V-
V+
CD 1
QIG 1
Rack-Mount
9. PoE-enabled Gigabit Ethernet ports
10. Link/ACT LED for PoE-enabled Gigabit ports
11. PoE indicator for PoE-enabled Gigabit ports
12. Speed LED for PoE-enabled Gigabit ports
13. 1G/2.5G/ 5G/ 10GBase-T Ethernet ports with bypass
14. Link/ACT LED for non-PoE Gigabit ports
15. LED for 5G/2.5Gbps Ethernet speed indicator
16. LED for 10G/1Gbps Ethernet speed indicator
Rack-mounting
Step 1: Install left and right front mounting brackets to the switch using 4 M3 screws on each side
provided with switch.
Step 2: With front brackets orientated in front of the rack, nest front and rear brackets
together. Fasten together using remaining M4 screws into counter sunk holes.
Step 3: Fasten the front mounting bracket to the front of the rack.
1G/2.5G/5G/10GBase-T M12
X-coding
Pin No.
Pin Definition
#1
BI_DA+
#2
BI_DA-
#3
BI_DB+
#4
BI_DB-
#5
BI_DD+
#6
BI_DD-
#7
BI_DC-
#8
BI_DC+
10/100/1000Base-T(X) P.S.E. M12
X-coding
Pin No.
Pin Definition
#1
BI_DA+ with PoE Vout+
#2
BI_DA- with PoE Vout+
#3
BI_DB+ with PoE Vout-
#4
BI_DB- with PoE Vout-
#5
BI_DD+
#6
BI_DD-
#7
BI_DC-
#8
BI_DC+
Unit =mm (Tolerance ±0.5mm)
Reduced Air Flow: Make sure the amount of air flow required for safe operation of the
equipment is not compromised during installation.
Mechanical Loading: Make sure the mounting of the equipment is not in a hazardous
condition due to uneven mechanical loading.
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
N.C.
Pow er
72~110 VDC
Rel ay Con sole
Rese t
LNK /ACT LNK /ACT
PoE
Spe ed
TRGPS-908 4TG -M12X-B P2- MV
10G /1G
Ring
Faul t
R.M
PWR
G1 G2 G3 G4 G 5 G6 G7 G8 TG1
TG1 TG3TG2 T G4
TG2 TG3 T G4
Powe r
Fail ure
Bypa ss
1.BI _DA+/ PoE Vout +
2.BI _DA- /P oE Vout+
3.BI _DB+/ PoE Vout -
4.BI _DB- /P oE Vout-
G1~ G8 TG1~T G4
1.BI _DA+
2.BI _DA-
3.BI _DB+
4.BI _DB-
5.BI _DD+
6.BI _DD-
7.BI _DC-
8.BI _DC+
5.BI _DD+
6.BI _DD-
7.BI _DC-
8.BI _DC+
1
2
5
15
67 8 9 10 11
12
13 14
16
N/A
3
5G/ 2.5G
4
LED
Color
Status
Description
PWR Green On DC power module activated
R.M Green On Device operating in Ring Master mode
Ring Green
On Ring enabled
Blinking Ring structure is broken
Fault Amber On Errors occur (i.e. power failure or port malfunctioning)
10/100/1000Base-T(X) P.S.E Ethernet ports
LNK/ACT Green On Port is linked
Blinking Transmitting data
PoE Green On Power supplied over Ethernet
Speed
Green On Port is running at 1000Mbps
Amber On Port is running at 100Mbps
Green/Amber Off Port is running at 10Mbps
1G/2.5G/5G/10GBase-T Ethernet ports
LNK/ACT Green On Port is linked
Blinking Transmitting data
5G/2.5G Amber On Port is running at 2.5Gbps
Green On Port is running at 5Gbps
10G/1G Amber On Port is running at 1Gbps
Green On Port is running at 10Gbps
Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Version 1.1
Q I G
Specifications
S w i tc h
E N 5 0 1 5 5
1. Launch the Internet Explorer and type in IP address of the device. The default static
IP address is 192.168.10.1
Follow the steps below to log in and access the system:
2. Log in with default user name and password (both are ).admin
3. After logging in, you should see the following screen. For more information on
configurations, please refer to the user manual. For information on operating the device
using ORing’s Open-Vision management utility, please go to ORing website.
Resetting
To restore the device configurations back to the factory defaults, press the button for 5Reset
seconds. Once the power indicator starts to flash, release the button. The device will then reboot
and return to factory defaults.
Configurations
After installing the and connecting cables, he green power LEDswitch t
should turn on. Please refer to the following tablet for LED indication.
Power
Redu nd ant Input Power
Physical Chara cteristic
Enclosure IP-30
Dimension (W x D x H) 43 8 (W ) x 25 0 (D ) x 44 ( H) m m (1 7. 24 x9 .8 4x1.73 inch)
Weight (g)
Environmenta l
-40 to 85 C (-40 to 185 F)
o o
Storage Temperature
5% t o 95 % Non-condensing
Operating Humidity
Regulatory App rovals
EN 55024 (IEC 61000-4-2 (ESD), IEC 61000-4-3 (RS), IEC 61000-4-4 (EFT), IEC 61000-4-5 (Surge),
IEC 61000-4-6 (CS), IEC 61000-4- 8 (P FM F) , IE C 61 00 0- 4- 11 ( DI P) )
EMS
IEC60068-2-27
Shock
IEC60068-2-31
IEC60068-2-6
Vibration
Free Fall
MTBF
EN60950-1
Other
Fault Contact
Relay Relay output to carry capacity of 3A at 24VDC on M12 connector (5-pin M12 A-c od in g, fe ma le c on nector)
Overload Current Protec ti on
Revers e Polarity P ro tection P re se nt
-40 to 75 C (-40 to 167 F)
o o
Operating Tempe rature
ORing Switch Model
10/100/1000 Base-T(X ) Ports
in M12 Auto MDI/MDIX with
P. S. E.
8 x M12 connect or (8 pin X-coding, )female conn ector
Physical Ports
Technology
Ethernet Standard s
IEEE 802.3i for 10Base-T
IEEE 802.3u for 100Base -TX
IEEE 802.3ab for 1000 Ba se -T
IEEE 802.3bz for 2.5G Ba se-T
IEEE 802.3an for 10GB as e-T
IEEE 802.3x for Flow co nt rol
IEEE 802.3ad for LACP ( Li nk A ggregation Contro l Pr otocol)
IEEE 802.1p for COS (Cl as s of Service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spa nn ing Tree Pr ot ocol)
IEEE 802.1s for MSTP (M ul tiple Spanning Tree Protocol)
IEEE 802.1x for Authent ic ation
IEEE 802.1AB for LLDP (Li nk L ay er D iscovery Protocol)
IEEE 802.3at PoE specificatio n (u p to 30 Watts per po rt f or P.S.E .)
IEEE 802.3af PoE specificatio n (u p to 15.4 Watts pe r po rt f or P.S.E.)
32K
MAC Table
8
Priority Queues
1G/2.5G/ 5G/1 0G Base-T
Port s in M12 Auto MDI/MDIX
4 x M12 connect or (8-pin X-coding, )female co nnector
Store-and-Forward
Processing
Sw itch Properties
Sw itching latency: 7 us
Sw itching bandwidth: 96 G bp s
Max. Number of Ava ilable VLANs: 4095
IGMP multicast grou ps : 128 for each VLAN
Port rate limi ti ng: User Define
Security Features
Device Binding securi ty f eature
Enable/disable po rt s, MAC based port securit y
Port b as ed network access contr ol ( 802.1x)
VLAN (802.1Q) to segr eg ate and secure network traffi c
Radi us c entralized password manag em ent
SNMPv3 encrypted au th entication and access s ec urity
Https / SSH enhance network s ec urity
Software Fea tures
STP/RSTP/MSTP (IE EE 8 02.1D/w/s)
Redu nd ant Ring (O-Ring) wit h re co ve ry t ime less than 30ms
TOS/ Di ffserv supported
Quality of Service (802 .1 p) for real-time traffic
VLAN (802.1Q) with VLAN t ag ging and GVRP support ed
IGMP Snooping
IP-based bandwidt h ma nagement
Application based Q oS m an agement
DOS/DDOS auto preventio n
Port c on figura tion, status, stati st ics, monitoring, se cu rity
DHCP Server / Client suppor t
SMTP Client
Modbus TCP
Network Redundancy
O-Ring
O-Chain
MSTP (RSTP/STP comp at ible)
Up to 10.2K Bytes
Jumbo frame
RS-232 Serial Conso le Port RS-232 in 5-pin M12 connector with optional console cable which can be purchased separat el y.
11 5200bps, 8, N, 1
Powe r Co nsumption(Typ.)
ORing Industrial Networking Corp.
Copyright© 2019 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com
TRGPS-9084TG-M12X-BP2-M V
110 (50.4-154) VDC on 4-pin S-coding, male connector
41 Watts (power consumption of P.S.E. is not included)
3919g
Warranty
5 ye ar s
15 0865 hrs
EN 55032, CISPR32, EN 6100-3-2, EN 6100-3-3,FCC Pa rt 1 5B class A
EMI
Present
TRGPS-9084TG-M12X-BP2-MV
I N D U S T R I A L
Rack-Mount
TRGPS-9084TG-M12X-BP2-MV
TRGPS-9084TG -M12X-BP2-MV
CE EMC (EN 55024, EN 55032), FCC Part 15 B, EN50155 (EN50121-3-2, EN55011)
EMC
EN50155 12-por t managed 10G/2.5G PoE Ethernet switc h with
8x10/100/100 0Base-T(X) P.S .E. and 4 x100/1G/2.5G/10GBase-T(X),
M12 connector an d 2xbypass included
EN50155 Rack-mount managed
10G/2.5G PoE Ethernet switch

Other manuals for TRGPS-9084TG-M12X-BP2-MV

1

Other ORiNG Switch manuals

ORiNG IGS-9122GPM User manual

ORiNG

ORiNG IGS-9122GPM User manual

ORiNG TPS-1080-M12 User manual

ORiNG

ORiNG TPS-1080-M12 User manual

ORiNG RES-3242GC User manual

ORiNG

ORiNG RES-3242GC User manual

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG

ORiNG CPS-3080-C Operating and maintenance instructions

ORiNG IPS-1080A User manual

ORiNG

ORiNG IPS-1080A User manual

ORiNG IES-3160 User manual

ORiNG

ORiNG IES-3160 User manual

ORiNG IES-3080 Series User manual

ORiNG

ORiNG IES-3080 Series User manual

ORiNG IGS-9844GPFX Series User manual

ORiNG

ORiNG IGS-9844GPFX Series User manual

ORiNG IES-2060 Series User manual

ORiNG

ORiNG IES-2060 Series User manual

ORiNG IGS-1042GPA User manual

ORiNG

ORiNG IGS-1042GPA User manual

ORiNG IGPS-9042GP-24V User manual

ORiNG

ORiNG IGPS-9042GP-24V User manual

ORiNG IBS-102FX User manual

ORiNG

ORiNG IBS-102FX User manual

ORiNG IPS-2042TX Series User manual

ORiNG

ORiNG IPS-2042TX Series User manual

ORiNG Thunder Series User manual

ORiNG

ORiNG Thunder Series User manual

ORiNG RGS-9244GP User manual

ORiNG

ORiNG RGS-9244GP User manual

ORiNG IGPS-1041GTA User manual

ORiNG

ORiNG IGPS-1041GTA User manual

ORiNG IES-180-L User manual

ORiNG

ORiNG IES-180-L User manual

ORiNG TRGPS-9084GT-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084GT-M12X-BP2-MV User manual

ORiNG IES-2050A User manual

ORiNG

ORiNG IES-2050A User manual

ORiNG IPS-3082GC-AT User manual

ORiNG

ORiNG IPS-3082GC-AT User manual

ORiNG IES-1080A User manual

ORiNG

ORiNG IES-1080A User manual

ORiNG TPS-3162GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3162GT-M12-BP1 User manual

ORiNG IGPS-9084GP User manual

ORiNG

ORiNG IGPS-9084GP User manual

ORiNG IES-3162GC Series User manual

ORiNG

ORiNG IES-3162GC Series User manual

Popular Switch manuals by other brands

StarTech.com IES101002SFP quick start guide

StarTech.com

StarTech.com IES101002SFP quick start guide

TEUCER TSS-2G manual

TEUCER

TEUCER TSS-2G manual

H3C FS5100-EI Series manual

H3C

H3C FS5100-EI Series manual

Honeywell C6097 technical information

Honeywell

Honeywell C6097 technical information

NetComm NP2008 User's installation guide

NetComm

NetComm NP2008 User's installation guide

HP A7533A - Brocade 4Gb SAN Switch Base Hardware reference guide

HP

HP A7533A - Brocade 4Gb SAN Switch Base Hardware reference guide

TP-Link Tapo S500 user guide

TP-Link

TP-Link Tapo S500 user guide

Festo EduTrainer 576309 operating instructions

Festo

Festo EduTrainer 576309 operating instructions

Digitus DN-651113 user manual

Digitus

Digitus DN-651113 user manual

Samsung SmartThings Hub manual

Samsung

Samsung SmartThings Hub manual

Apex Digital ADP1 Quickspecs

Apex Digital

Apex Digital ADP1 Quickspecs

SWR mo'CONTROL user guide

SWR

SWR mo'CONTROL user guide

Extron electronics SW HD 4K PLUS Series user guide

Extron electronics

Extron electronics SW HD 4K PLUS Series user guide

EMP-Centauri OMS5/4 instruction manual

EMP-Centauri

EMP-Centauri OMS5/4 instruction manual

American Dynamics AD1476-C Installation and operating instructions

American Dynamics

American Dynamics AD1476-C Installation and operating instructions

LEGRAND 0 672 63 quick start guide

LEGRAND

LEGRAND 0 672 63 quick start guide

hiltbrand DUNGS GGW A4 Series instructions

hiltbrand

hiltbrand DUNGS GGW A4 Series instructions

LINK-MI LM-SW121 manual

LINK-MI

LINK-MI LM-SW121 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.