manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ORiNG
  6. •
  7. Switch
  8. •
  9. ORiNG IGS-9080 User manual

ORiNG IGS-9080 User manual

IGS-9080
PWR
PWR1
PWR2
R.M
Ring
Fault
10/100/
1000T
G3
G4
G1
G2
G7
G8
G5
G6
Reset
Quick Installation Guide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
The is a managed industrial Ethernet switch with eight
10/100/1000Base-T(X) ports. The series consists of the and
models to meet different application needs. The former
supports IEEE 1588v2 clock synchronization while the latter does not.
The switch supports Ethernet Redundancy protocol, O-Ring (recovery time
< 30ms over 250 units of connection) and MSTP (RSTP/STP compatible) to
protect mission-critical applications from network interruptions or
temporary malfunctions with fast recovery technology. With a wide
operating temperature from -40 C to 70 C, the device can be managed
centrally via ORing’s proprietary Open-Vision platform as well as via Web-
based interfaces, Telnet, and console (CLI). The switch is one of the most
reliable choices for highly-managed and fiber Ethernet applications.
IGS-9080 series
IGPS-9080
IGPS-9080-NP
oo
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient:
Reduced Air Flow:
Mechanical Loading:
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven mechanical
loading.
Safety & Warnings
Dimension
Panel Layouts
11
1. Reset button
2. PWR status LED
3. PWR1 LED
4. PWR2 LED
5. R.M. status LED
6. Ring status LED
7. Faulty relay indicator
8. Console port
9. Port speed LED
10. Port link LED
11. Gigabit Ethernet ports
Package Contents
Contents
DIN-rail Kit
CD
IGS-9080 /
IGS-9080-NP
Pictures Number
X1
X1
X1
Front View
Top Panel
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
QIG
Console Cable
X1
X1
X1
Wall-mount Kit
10
Rear View
12
1
1. Wall-mount screw holes
2. Din-rail screw holes
1. Terminal blocks: PWR1, PWR2
(12-48V DC), Relay
1
Installation
Step 1:
Step 2:
Slant the switch and screw the Din-rail kit onto the back of the switch, right in
the middle of the back panel.
Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch
clicks into the rail firmly.
DIN-rail Installation
Step 1:
Step 2:
Step 3:
Screw the wall-mount kit onto the rear panel of the switch. A total of six
screws are required, as shown below.
Use the switch, with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Insert a screw head through the large parts of the keyhole-shaped apertures,
and then slide the switch downwards. Tighten the screws for added stability.
Wall-mounting
IGS-9080 Series
QIG IGS-9080 1907-2-29-IGS9080-1.0
Circuit Overloading: Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might have
on overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
9
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch uses
CAT 3,4,5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable
specifications.
Cable Types and Specifications:
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 1 00-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (328 ft) RJ-45
54.3
32.2
45.0
14.0
40.0
50.0
25.3
33.6
12.5
54.3
145.1
108.5
32.0
32.2
116 .0
18.0 18.15
51.0
209.3 7.35
187.4
R2.5
R3.95
46.0
IGS-9080
PWR
PWR1
PWR2
R.M
Ring
Fault
10/100/
1000T
G3
G4
G1
G2
G7
G8
G5
G6
Reset
8
2
3
4
5
6
7
1
IGS-9080
PWR
PWR1
PWR2
R.M
Ring
Fault
10/100/
1000T
G3
G4
G1
G2
G7
G8
G5
G6
Reset
QIG Quick Installation Guide
PRINTED ON RECYCLED PAPER
Version 1.0
Quick Installation Guide
Resetting
To reboot the switch, press the button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the button for 5 seconds.
Reset
Reset
Specifications
GIGABIT
INDUSTRIAL
SWITCH
Industrial Managed Gigabit Switch
For pin assignments for different types of cables, please refer to the following
tables.
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment RS-232 with DB9 (female) pin
assig nment (RJ45-DB9 cable) RJ45 pin assignment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5 GND PIN#5 GND PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
STEP 1:
STEP 2:
PWR-1PWR-2
1A@24V
V2-V2+ V1-V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are ). After logging in, you should
see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
admin
Follow the steps to set up the switch:
ORingSwitchModel IGS-9080
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3ab for 1000Base-T
IEEE 802.3x for Flow control
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
IEEE 1588v2 clock synchronization
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.1p for COS (Class of service)
Power
Redundant Input power
Power consumption(Typ.)
Dual DC inputs. 12-48VDC on 6-pin terminal block
10.92 watts
Overload current protection Present
Physical Characteristic
Enclosure IP-30
Dimension(WxDxH) 54.1(W)x106.1(D)x145.4(H) mm (2.13x4.18x5.72 inch.)
10/100/1000Base-T(X) Ports
in RJ45 Auto MDI/MDIX
MAC Table 8K
RS-232 Serial Console Port
Priority Queues 8
Processing Store-and-Forward
Switch Properties
Switch latency: 7 us
Switch bandwidth: 16Gbps
Max. Number of Available VLANs: 256
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
VLAN (802.1q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Software Features
STP/RSTP/MSTP (IEEE 802.1D/w/s)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
IP-based bandwidth management
Application-based QoS management
DOS/DDOS auto prevention
Port configuration, status, statistics, monitoring, security
DHCP Server / Client support
SMTP Client
Modbus TCP
Network Redundancy O-Ring, Open-Ring, O-chain, MRP, MSTP (RSTP/STP compatible)
RS-232 in RJ45 connector with console cable. Baud rate setting: 115200bps, 8, N, 1
Weig ht (g ) 776 g
8
Jumbo frame Up to 9.6K Bytes
Weig ht (g ) 710 g 740 g722 g 735 g 735 g 740 g
Environmental
-40to85C(-40to185F)
oo
Storage Temperature
-40to70C(-40to158F)
oo
Operating Temperature
5% to 95% Non-condensingOperating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class AEMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
IEC60068-2-27Shock
IEC60068-2-32
IEC60068-2-6Vibration
EN60950-1
Safety
Free Fall
Warranty
5 years
LED Color Status Description
PWR Gree n On DC power on
PWR 1 Green On D C power module 1 activated
PWR 2 Green On D C power module 2 activated
R.M Green On Ring Master
On Rin g enabl ed
Ring Green Blinking Ring structure is broken (i.e. part of the ring is
disconnected)
Fault Amber On Faulty relay (power failure or port disconnected)
10/100/1000Base-T(X) Gigabit Ethernet ports
On Port l ink UP
LNK/ACT Green
Blinking Data transmitted
Green On Port lin k at 1000Mbps
Amber On Port l ink at 10/100Mbps
Speed
Green/Amber Off Port link at 10Mb ps
ORing Industrial Networking Corp.
Copyright© 2014 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X p ort
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3RD+(receive)TD+(transmit)
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_ DA+ B I_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5BI_DC-BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
1000Base-T RJ-45 Port
Pin Number Assi gnment
1BI_DA+
2BI_DA-
3BI_DB+
4BI_DC+
5 BI_DC-
6BI_DB-
7BI_DD+
8 BI_DD-
10/10 0 Base- T(X) RJ-45 Port
Pin Number Assignments
1TD+
2TD-
3 RD+
4 Not used
5 Not used
6RD-
7 Not used
8 Not used
IGS-9080-NP
IEEE 1588v2 cloclk
synchronization
supported Not supported
Fault Contact
Relay Relay output to carry capacity of 1A at 24VDC
ReversePolarityProtection
Present
IGS-9080 Series
QIG IGS-9080

This manual suits for next models

1

Other ORiNG Switch manuals

ORiNG IES-3240 User manual

ORiNG

ORiNG IES-3240 User manual

ORiNG IPS-3082GC-AT User manual

ORiNG

ORiNG IPS-3082GC-AT User manual

ORiNG IES-1041FX-MM-SC User manual

ORiNG

ORiNG IES-1041FX-MM-SC User manual

ORiNG IES-3080 Series User manual

ORiNG

ORiNG IES-3080 Series User manual

ORiNG IGS-3044GC User manual

ORiNG

ORiNG IGS-3044GC User manual

ORiNG TPS-3162GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3162GT-M12-BP1 User manual

ORiNG IPS-1080-24V User manual

ORiNG

ORiNG IPS-1080-24V User manual

ORiNG IGPS-1411GTPA User manual

ORiNG

ORiNG IGPS-1411GTPA User manual

ORiNG TES-250-M12 User manual

ORiNG

ORiNG TES-250-M12 User manual

ORiNG TRGPS-9084GT-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084GT-M12X-BP2-MV User manual

ORiNG TGXPS-1080-M12-24V Series User manual

ORiNG

ORiNG TGXPS-1080-M12-24V Series User manual

ORiNG IGS-9844GPFX Series User manual

ORiNG

ORiNG IGS-9844GPFX Series User manual

ORiNG IGPS-9084GP User manual

ORiNG

ORiNG IGPS-9084GP User manual

ORiNG IGPS-1041GTA User manual

ORiNG

ORiNG IGPS-1041GTA User manual

ORiNG IGPS-R9084GP User manual

ORiNG

ORiNG IGPS-R9084GP User manual

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG IGS-1050A User manual

ORiNG

ORiNG IGS-1050A User manual

ORiNG IGS-9084GP-FB2 User manual

ORiNG

ORiNG IGS-9084GP-FB2 User manual

ORiNG IGPS-1080A User manual

ORiNG

ORiNG IGPS-1080A User manual

ORiNG GS-9164GF Series User manual

ORiNG

ORiNG GS-9164GF Series User manual

ORiNG IGS-9168GP series User manual

ORiNG

ORiNG IGS-9168GP series User manual

ORiNG IGPS-9822DGP+ User manual

ORiNG

ORiNG IGPS-9822DGP+ User manual

ORiNG IES-2050 User manual

ORiNG

ORiNG IES-2050 User manual

Popular Switch manuals by other brands

Lenovo ThinkSystem NE25720 installation guide

Lenovo

Lenovo ThinkSystem NE25720 installation guide

MORLEY ABYES manual

MORLEY

MORLEY ABYES manual

TRENDnet TEG-S16R - DATA SHEETS Quick installation guide

TRENDnet

TRENDnet TEG-S16R - DATA SHEETS Quick installation guide

Emerson TARTARINI V/31-2-AP-E Series instruction manual

Emerson

Emerson TARTARINI V/31-2-AP-E Series instruction manual

3Com 3C16670 - LinkBuilder FMS II Hub Configuration guide

3Com

3Com 3C16670 - LinkBuilder FMS II Hub Configuration guide

Crestron infiNET CLW-SLVS1RF Operation guide

Crestron

Crestron infiNET CLW-SLVS1RF Operation guide

Hama USB 3.0 Hub 1:4 Operating	 instruction

Hama

Hama USB 3.0 Hub 1:4 Operating instruction

Crestron DM-MD8X1-4K-C Supplemental guide

Crestron

Crestron DM-MD8X1-4K-C Supplemental guide

Crystal Image Technologies LCDK2003 user manual

Crystal Image Technologies

Crystal Image Technologies LCDK2003 user manual

Kobold NV operating instructions

Kobold

Kobold NV operating instructions

Digicom 8E4090 brochure

Digicom

Digicom 8E4090 brochure

Ocean Matrix OMX-DEM100 instruction manual

Ocean Matrix

Ocean Matrix OMX-DEM100 instruction manual

Goobay 60811 manual

Goobay

Goobay 60811 manual

Extron electronics System 8 Plus installation instructions

Extron electronics

Extron electronics System 8 Plus installation instructions

ATEN Slideaway CL5708 user manual

ATEN

ATEN Slideaway CL5708 user manual

Manhattan 162272 instructions

Manhattan

Manhattan 162272 instructions

Lenovo RackSwitch G8296 installation guide

Lenovo

Lenovo RackSwitch G8296 installation guide

Hawking CS112U Specifications

Hawking

Hawking CS112U Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.