General information
This manual is about pump speed control. Every pump type has its own manual; MA25-01 for pump type P01 and MA25-05 for
pump type VISE. User and installer should read both the speed control manual concerning the pump type carefully in order to
ensure the pump correct functioning and long service life.
If the product is used improperly, is not suciently maintained or modied there is a risk of injury to humans or materials.
Pahlén AB is not responsible for the product warranty in case of any damage due to improper installation, mishandling
or maintenance.
Modication or change of the product may only be done upon manufacturer’s approval. Use only spare parts or accessories
approved by the manufacturer.
Transportation and seasonal storage:
Keep the pump in a dry environment at a stable temperature. (Sharp temperature changes and humid environments can cause
damage from corrosion to the motor windings or metal parts.)
Product description
The speed-controlled pump is intended for circulation of ltered water in pools with chlorine disinfection (organic, inorganic
chlorine types). Pahlén cannot guarantee the pump’s long service life and good performance with other types of disinfectants.
Follow the water values recommended in the pump manual.
Speed control provides options for changing speed of the pump as required. Lower speed reduces pump power consumption
and noise levels. There are three preset speeds, as well as ve complete weekly timer programs to choose from. They are
enough for most of the requirements. There is also an option to congure the weekly timer and speed on your own manually.
Technical data
Maximum temperature of pool water/surroundings +45°C
IP protection rating IP55
Refer to the pump model rating plate for information about maximum lifting height (Hmax).
Electric installations
NOTE! The pump must never be started without being water lled.
The pump electric motor must be installed by a qualied electrician, and the installation must comply with national regulations.
Electrical installation must be done after pipes installation.
The pump must be shielded and powered via a ground fault switch which will disengage operation not exceeding 30mA.
The pump must also be equipped with an all-pole switch and approved engine protection to be set according to the motor
current value. Refer to the pump motor nameplate for information on voltage and type of connection.
External connection of speed control
(Potentially free alternating contacts)
NOTE! If the external cable will not be used, these cable ends
should be isolated from one another.
Brown (d1)
Black (
GND
)
Green (d2)
(max 100mA)
Red + 5V
White (rEL)
1-phase
1~230 V