Quick User Guide for Paradox
Spectra SP Series
SYSTEM MASTER CODE 12 4
1) How to ARM the alarm system
a) How to do (REGULAR ARMING) the alarm system
Hold [ARM] 3 seconds or [ARM] + [Access code]
) How to do (STAY ARMING) the alarm system
Hold [STAY] 3 seconds or [STAY] + [Access code]
c) How to do (SLEEP ARMING) the alarm system
Hold [SLEEP] 3 seconds or [SLEEP] + [Access code]
2) How to DISARM the alarm system
[OFF] + [Access Code]
) How to BYPASS a zone
SP Series panel does not allow the system to e armed when
there is a defective sensor. User will need to manually
BYPASS the zones where the defective sensor is installed.
4) How to view most recent alarm trigerred zone
After the alarm triggered, all triggered zone will e stored in
Press [MEM] Key
memory. The [MEM] key will light on.
Press [CLEAR] to Exit
5) How to change System Master code?
System Master code elongs to the owner. Master code can
add/edit/delete Access codes.
6) How to create Access Code?
Access code is assigned to the tenant that is renting the room.
After tenant stops renting, owner can use the Master code
to delete the old Access code and assign a new Access Code
to new tenant.
7) How to check Panel problem?
Press [TBL] and the keypad num ers will light up corresponding
When there is technical pro lem arise, the [TBL] light on
to the pro lem detected.
keypad will turn on.
[2] Power trou le
[3] Bell (Siren) trou le
[4] Communication trou le
[8] Timer loss
[0] Module Supervision Loss
Press the num er to see more details on the pro lems detected.
[2] Power trouble
[1] Panel low attery
[2] AC power loss
[3] Aux. overload on panel
[ ] Bell (Siren) trouble
[1] Bell disconnected
[2] Bell overload
[4] Communication trouble
[1] Telephone line monitoring on control panel
[2] Fail to communicate on CMS telephone 1
[3] Fail to communicate on CMS telephone 2
[4] Fail to communicate on pager
[5] Fail to communicate on voice telephone
[6] Fail to communicate with PC
[8] Timer Loss
Set current date & time:
[TBL] + [8] + [HH:MM] (key in 12 hours format) + [2=am, 3=pm]
+ (YYYY) + (MM) + (DD) + [CLEAR]
[0] Module Supervision Loss
To clear us module trou le:
Enter Programming Section 955 > Wait few seconds to refresh
v1.1 (Aug'13)
Prepared y:
Belco Security Sdn Bhd
14, Jalan Intan 1, Taman Puchong Intan, 47150
Puchong, Selangor. Tel: 03-8062 3100 Fax: 03-9235 1118
[ ] + [System Master Code] + [01] + [New System Master Code] +
[Repeat New System Master Code] + [ENTER, CLEAR]
[ ] + [System Master Code] + [04] + [New Access Code] + [Repeat
New Access Code] + [ENTER, CLEAR]
[BYP] + [Access Code] + (2-digit Zone Num ers) + [ENTER]
Quick Programming Guide for Paradox
Spectra SP Series
DEFAULT INSTALLER CODE: 0000
v1.1 (Aug'13)
To enter Programming mode, press (ENTER) + (INSTALLER CODE)
Programming mode status: ARM + STAY indicators linking
Step 1: Define Zones
Set Zone 1 as entry delay
Set Zone 2 as Instant
Set Zone 3 as Instant
Set Zone 4 as Instant
Set Zone 5 as Instant
Set Zone 6, Zone 7 and so on…
01 = Entry Delay 1
05 = Follow
08 = Instant
09 = Instant (Sleep/Full Arm)
10 = Instant (Full Arm)
16 = 24Hr. Burglary
26 = Keyswitch Momentary
*Refer Paradox Programming Guide Manual for more Zone Types
Zone Options
[1] Auto-zone Shutdown [4] [5]
[2] Bypassa le Zone
OFF OFF Audi le Alarm
[3] RF Zone Supervision OFF ON Pulsed Alarm
[6] Intellizone ON OFF Silent Alarm
[7] Delay Alarm Transmission ON ON Report Only
[8] Force Zone
Step 2: Set System Options and Timer
Ena le EOL resistor (if resistor eing used)
Set Entry Delay 1 timer [000] to [255] seconds
Set Exit Delay 1 timer [000] to [255] seconds
Set Bell cut timer = 5 minutes
Set Zone 1 sensitivity = 10 ms
Set Zone 2 sensitivity = 10 ms
Set Zone 3 sensitivity = 10 ms
Set Zone 4 sensitivity = 10 ms
Set Zone 5 sensitivity = 10 ms
Set Zone 6, Zone 7 sensitivity and so on…
Ena le for Audi le Panic:
(1: Panic 1) - Hold key [1]+[3] together
(2: Panic 2) - Hold key [4]+[6] together
(3: Panic 3) - Hold key [7]+[9] together
(4: Audi le alarm for Panic 1 utton)
(5: Audi le alarm for Panic 2 utton)
(6: Audi le alarm for Panic 3 utton)
ENTER, CLEAROn key [1, 2]108002
Command
Description ConfirmZone OptionsPartitionZone TypeSection
ENTER, CLEAROn key [1, 2, 8]101001
Follow
Entry Delay 1
Follow
Entry Delay 1Entry Delay 1
Follow
ENTER, CLEAROn key [1, 2]1
ENTER, CLEAROn key [1, 2]1
08003
006, 007 and so on…
Full ArmSleep ArmStay ArmZone Type
ENTER, CLEAROn key [1, 2]108005
08004
Instant
Arm/Disarm when receive signal
Zone can trigger alarm even in DISARM mode
Instant
Instant
Instant
Instant
Not ArmedNot Armed
Not Armed
Instant
Description
CLEAR
CLEAR
CLEAR
CLEAR
CLEAR
ConfirmTimer & OptionSection
Command
ENTEROn key [2]706
ENTER, CLEAROn key [1, 2, 3, 4, 5,6]702
CLEAR
CLEAR
CLEAR
CLEAR
710
010
010
010
010
010
010
005
060
030
046, 047 and so on…
045
044
043
041
747
745
042
Step : Optional Settings
Partitioning
(to ena le 2 partitions)
Ena le Bell Squawk when arm/disarm
with Keypad / Generic Remote Control
Change Installer Code (Default: 0000)
Change Master Code (Default: 1234)
Reset All Programming to Default
Remote Control Assignment
611 for Rem#1, 612 for Rem#2,… up to 642 for Rem#32
Enroll Remote Control (REM15)
651 for Rem#1, 652 for Rem#2,.. Up to 682 for Rem#32
Step 4: Set Telephone Programming (Dial Out when alarm triggers)
Set Dialing attempts
Activate VDMP3 function*
Rings to pickup y panel*
*Only required if VDMP3 Voice Module installed
To e done in Stand y Mode (Exit Programming Mode first):
Set to dial telephone #1
Set to dial telephone #2
Set to dial telephone #3
Set to dial telephone #4
Set to dial telephone #5
Step 5: Set Central Monitoring Station (CMS) Function
(only required if connected to ADT, CHUBB, PROTECS etc)
Set Contact ID Format
Set Account num er Partition 1
Set Account num er Partition 2
Set Telephone 1 (primary)
Set Telephone 2 (secondary)
Set Alternate Dial:
Set always report disarm
Set send daily test report
Set time for test signal
Step 6: Perform Walk Test
The Installer Test mode will allow you to perform walk tests where the siren will squawk to indicate opened zones.
To Activate: [ENTER] [INSTALLER CODE] [TBL] [CLEAR] To DeActivate: [ENTER] [INSTALLER CODE] [TBL] [CLEAR]
Step 7: Hard Reset Panel
If settings have een entered wrongly and the panel does not work as desired, panel can e reset y doing the following:
i) Press & Hold Reset utton on Main Panel for 5 seconds, then notice the Status LED linking.
ii) Once linking, quickly release the utton and press again one time to reset to factory defaults.
Prepared y: Belco Security Sdn Bhd
14, Jalan Intan 1, Taman Puchong Intan, 47150
Puchong, Selangor. Tel: 03-8062 3100 Fax: 03-9235 1118
651
Description Command
ConfirmTimer & Option
611
950
ENTER, CLEAR704
ENTER, CLEAR
399
397
700
New Code: XXXX
New Code: XXXX
(Default is OFF)
ON key [5]
Description Command
Section Timer & Option Confirm
(Auto call the secondary num er if primary
num er is usy)
ENTERTelephone num er 2817
ENTERTelephone num er 1815
4 digit Account num er812
Section
841
(Default is OFF)
ON key [1]
Press and Hold any utton for
2 times
ENTER, CLEAR[1888] [8888]
ENTER
Command
Description
005
ENTER, CLEAR
ENTER, CLEAR
010
On key [8]
901
703
[ ] + [Master code] + [MEM] + [7] + [5th phone num er] + ENTER, CLEAR
[ ] + [Master code] + [MEM] + [6] + [4th phone num er] + ENTER, CLEAR
[ ] + [Master code] + [MEM] + [5] + [3rd phone num er] + ENTER, CLEAR
[ ] + [Master code] + [MEM] + [4] + [2nd phone num er] + ENTER, CLEAR
[ ] + [Master code] + [MEM] + [3] + [1st phone num er] + ENTER, CLEAR
ENTER, CLEAR4 digit Account num er811
4, 4810
ConfirmTimer & OptionSection
ENTER, CLEAROn key [4]800
850 [ HH:MM ]
ENTER, CLEAR001840
ENTER, CLEAROff key [1]801

Other Paradox Security System manuals

Paradox StayD Series User manual

Paradox

Paradox StayD Series User manual

Paradox SP6000 Operating instructions

Paradox

Paradox SP6000 Operating instructions

Paradox ESPRIT 728 ULT Operating instructions

Paradox

Paradox ESPRIT 728 ULT Operating instructions

Paradox Magellan MG5050E User manual

Paradox

Paradox Magellan MG5050E User manual

Paradox MG-RTX3 User manual

Paradox

Paradox MG-RTX3 User manual

Paradox Paradox User manual

Paradox

Paradox Paradox User manual

Paradox SPECTRA 1727 User manual

Paradox

Paradox SPECTRA 1727 User manual

Paradox Magellan MG5050 EN User manual

Paradox

Paradox Magellan MG5050 EN User manual

Paradox 1686V User manual

Paradox

Paradox 1686V User manual

Paradox K07C User manual

Paradox

Paradox K07C User manual

Paradox Digiplex EVO48 V1.20 User manual

Paradox

Paradox Digiplex EVO48 V1.20 User manual

Paradox SR120 User manual

Paradox

Paradox SR120 User manual

Paradox Magellan K636 User manual

Paradox

Paradox Magellan K636 User manual

Paradox Magellan DCT2 User manual

Paradox

Paradox Magellan DCT2 User manual

Paradox Esprit 727 Service manual

Paradox

Paradox Esprit 727 Service manual

Paradox SP5500 Operating instructions

Paradox

Paradox SP5500 Operating instructions

Paradox DGP2-641 User manual

Paradox

Paradox DGP2-641 User manual

Paradox Esprit 727 User manual

Paradox

Paradox Esprit 727 User manual

Paradox ESPRIT 728 ULT Operating instructions

Paradox

Paradox ESPRIT 728 ULT Operating instructions

Paradox Spectra User manual

Paradox

Paradox Spectra User manual

Paradox SR150 User manual

Paradox

Paradox SR150 User manual

Paradox SR150 User manual

Paradox

Paradox SR150 User manual

Paradox Digiplex EVO DGP2-640 User manual

Paradox

Paradox Digiplex EVO DGP2-640 User manual

Paradox PGM4 User manual

Paradox

Paradox PGM4 User manual

Popular Security System manuals by other brands

Smartek NUBI 4.0 manual

Smartek

Smartek NUBI 4.0 manual

Smanos SS-20 user manual

Smanos

Smanos SS-20 user manual

Langmatz EK 533 operating instructions

Langmatz

Langmatz EK 533 operating instructions

HomeMatic 4047976424085 Installation and operating manual

HomeMatic

HomeMatic 4047976424085 Installation and operating manual

Tenda K4P-4TR installation guide

Tenda

Tenda K4P-4TR installation guide

SORHEA BIRIS II 50 installation instructions

SORHEA

SORHEA BIRIS II 50 installation instructions

Evolveo Alarmex Pro ACSALMBTZ manual

Evolveo

Evolveo Alarmex Pro ACSALMBTZ manual

DyGSM G66A user manual

DyGSM

DyGSM G66A user manual

CIAS Elettronica S.r.l. BF installation manual

CIAS Elettronica S.r.l.

CIAS Elettronica S.r.l. BF installation manual

Assa Abloy Yale Easy Fit EF Series quick start guide

Assa Abloy

Assa Abloy Yale Easy Fit EF Series quick start guide

EURO One Operator's instruction manual

EURO

EURO One Operator's instruction manual

Climax BX-32 quick start guide

Climax

Climax BX-32 quick start guide

Barnett Engineering ProTalk LINK operating manual

Barnett Engineering

Barnett Engineering ProTalk LINK operating manual

Eaton 415-TF Instruction leaflet

Eaton

Eaton 415-TF Instruction leaflet

HOMCLOUD WL-RFSLS manual

HOMCLOUD

HOMCLOUD WL-RFSLS manual

Silent Alert UM3A-2212-EU MK XI quick start guide

Silent Alert

Silent Alert UM3A-2212-EU MK XI quick start guide

Sygonix DD01 operating instructions

Sygonix

Sygonix DD01 operating instructions

dixell XJA50D Installation and operating instructions

dixell

dixell XJA50D Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.