Paramount Fitness MDX-R3 Programming manual

295 East Corporate Place • Suite 100 • Chandler, AZ 85225
Phone: 0011 + 1 + 480.893.7607 • Fax: 0011 + 1 + 480.753.3397
[email protected] • www.1Paramount.com
US and Foreign patents and patents pending see www.1paramount.com/about/patents/
004-027-8826-00 ECN_1298 REV072117
MDX-R3 FOR FIBERGLASS POOLS
OWNER’S MANUAL AND INSTALLATION GUIDE -
AUSTRALIA
SUBMERGED SUCTION OUTLET
FOR MULTIPLE DRAIN USE FOR USE ON FLOOR
Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety
Act ANSI/APSP - 16 - 2011
Compliant with ANSI/APSP - 7 - 2006.
WARNING
MDX-R3 and SDX2 must be installed in accordance with Paramount’s written instruction
manual, and in conformity with applicable Federal, State, Local and Swimming pool industry
building and safety codes.
To Installers: Read and follow these instructions. Give these instructions to the facility owner to
keep for future reference. Follow all codes and regulations that apply to the design, installation
and use of suction outlet fittings.
NOTICE
For technical assistance call 1.800.621.5886 or contact your regional representative
2
PLEASE REVIEW THE OWNER’S MANUAL AND INSTALLATION GUIDE IN ITS ENTIRETY AND HEED
ALL SAFETY INFORMATION. Failure to follow these instructions and warnings can result in DEATH OR
SERIOUS INJURY.
DANGER indicates
a hazardous
situation which, if
not avoided, will result in death or serious injury.
DANGER
Signal Words and Symbols Used In This Manual
This Owner’s Manual and Installation Guide contains specific precautions and symbols to identify safety-
related information. You will find DANGER, CAUTION, WARNING and NOTICE symbols which require
special attention. Please read them carefully and follow these precautions as indicated! They will explain how to
avoid hazards that may endanger you or persons using or maintaining your pool or spa.
SUCTION ENTRAPMENT HAZARD:
DEATH or SERIOUS INJURY will result if a drain cover or grate is not
installed and used correctly.
• Pool and spa pumps produce high levels of suction and move high volumes of
water, which can cause death or serious injury if a person comes in close proximity to pool or spa drains.
• Keep clear of pool and spa drains to avoid death or serious injury from suction.
DEATH or SERIOUS INJURY will result from pool or spa drain covers or
grates that are improperly installed, missing, clogged, or broken.
• Inspect pool and spa before each use to ensure that drain covers and
grates are properly in place and secured.
• Ensure that drain covers are not damaged, cracked, broken, loose, clogged, not properly secured, or
missing because these conditions increase the chance of death or serious injury from entrapment.
• If a drain cover is discovered damaged, cracked, broken, loose, clogged, not properly secured, or
missing, you should:
• Close the pool or spa immediately; and,
• Post a closure notice and keep the pool or spa closed until an appropriate ANSI/APSP -16-2011
certified drain cover is properly installed.
DANGER DEATH or SERIOUS INJURY will result from hair entanglement or
limb entrapment.
• Keep clear of pool and spa drains.
• Hair sucked into pool or spa drains will tangle and knot trapping the
swimmer underwater. Avoid placing your hair near a pool or spa drain.
• Avoid sitting on pool or spa drains because the suction can cause
severe intestinal damage, evisceration, and/or disembowelment.
DANGER
DANGER
DANGER DEATH or SERIOUS INJURY will result from contact with a damaged,
loose, or missing drain cover.
• Do not allow limbs to contact or be inserted into a drain pipe with a
damaged, loose, or missing drain cover. This could result in swelling of
the limb and/or trapping a swimmer underwater.
• Avoid mechanical entrapment of jewelry, swimsuit, hair decorations,
finger, toe, or knuckle in a drain pipe with damaged, loose, or missing
drain cover. This may result in trapping a swimmer underwater.
• Do not allow body to come into contact with a drain pipe that has a
damaged, loose, or missing drain cover. This may result in trapping a
swimmer underwater.
WARNING indicates
a hazardous situation
which, if not avoided,
could result in death or serious injury.
WARNING
CAUTION indicates
a hazardous situation
which, if not avoided,
could result in minor or moderate injury.
CAUTION NOTICE is used to
address practices
not related to
physical injury.
NOTICE
For technical assistance call 1.800.621.5886 or contact your regional representative
3
MAINTENANCE INSTRUCTIONS & WARNINGS:
DEATH or SERIOUS INJURY can result from pool or spa drain covers or
grates that are clogged by debris.
• All pool and spa drain covers may become obstructed by debris and should be cleaned periodically
due to clogging from debris, such as pieces of plastic, hair, fabric, twigs, leaves, seeds, etc.
• The frequency of periodic cleaning will vary depending on the amount and type of debris introduced
into the pool or spa
• Clogging of the drain cover will increase the suction effect and increase the likelihood of death or
serious injury from those hazards listed above.
• A clogged drain can negatively affect the safety of the drain.
• It is advisable to have a qualified pool or spa professional perform this inspection and debris removal
from the pool an spa drain covers.
• When servicing the drain cover, the pump connected to the suction must be turned off.
• Do not perform any service of the drain cover in water level above your waist.
• Use drain covers only with a pumping system rated for the corresponding flow or less. Failure to do
so can result in hair or body entrapment which can cause death or serious injury. If in doubt about the
rating of your system, consult a qualified pool or spa professional.
• Use only the supplied stainless-steel screws with the drain cover. Screws put into the frame anywhere
except in the original screw holes will not hold and will allow the drain cover to come off the main
drain, causing an entrapment hazard. If a screw hole(s) is stripped, inserts missing, loose, or damaged,
consult your owner’s manual and installation guide for proper steps to replace, correct, or reattach the
compromised drain or drain component.
WARNING Suction can pose a serious hazard to swimmers just as electricity can be a
hazard. Both are important for proper water filtration and both must be treated
with respect. Suction safety begins with a professional design that includes a
quality suction system installed by a certified contractor.
Certified builders will address the following issues when designing and installing a proper filtration system:
• Properly bond-grounded pumps, time clocks, switches and any other metal in or near water. This is required to
address Electrical Shock Hazards.
• Design the suction piping so there are no single-point suction hazards; single-point suction (one drain) is a
leading cause of Body Suction Entrapment Hazards. Note: your certified builder has many effective options for
addressing this hazard; they may include dual-drain systems, like MDX-R3, skimmers, gutters, negative edge
features and many more products and piping designs known to professionals.
• Install ANSI/APSP - 16 - 2011 listed drains, suction covers and debris removal systems. This is the ONLY
approved option for preventing Hair Entrapment Hazards, the leading cause of suction related injuries.
• Design and install an effective circulation system (including optional cleaning systems), to direct filtered water
to all areas and interior surfaces. NOTE: Suction fittings can NOT clean or direct filtered water for proper
sanitation; that can only be done on the pressure (return) side of the filtration system.
While suction injuries are extremely rare, drowning and diving injuries are far too common and there is little
your certified builder can do to eliminate these hazards. You must educate yourself and your guests. Below are
some important safety issues every swimmer must know and recognize.
• PREVENT DROWNING: Watch children at all times, no swimming alone.
• NO DIVING IN SHALLOW WATER: You can be permanently injured.
• PREVENT SUCTION ENTRAPMENT: Inspect suction covers before swimming, keep swimmers away
from suction fittings, protect long hair, don’t swim with loose clothing or large and dangling jewelry.
For more information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer
Product Safety Commission at (301) 504-7908 or visit www.cpsc.gov.
Always turn off all power to the pool pump before installing the cover
or working on any suction outlet.
WARNING
WARNING
MDXR3 ANTI-ENTRAPMENT DEBRIS DRAIN
STANDARD POOL DESIGN, AUSTRALIA
DUAL DRAIN
SDX
SIZE TO MATCH
CIRCULATION LINE
SECOND DRAIN
ANY ORIENTATION
ENLARGED SUCTION
ELEMENT
50MM OR LARGER
CIRCULATION LINE
Design Flow Rate = 132 GPM (500 LPM)
Maximum GPM (LPM) = 132 (500)
Velocity at 132 GPM (500 LPM) = 1.294 FPS (.39 MPS)
0011 + 1 + 480.893.7607 or contact your
regional representative.
MDX-R3 SYSTEM DESIGN
These MDX-R3 instructions provide methods with or without skimmer to choose from. Your local codes may require
additional safety measures. Paramount Pool & Spa Systems and its representatives cannot recommend or endorse instal-
lation methods other than those provided in these MDX-R3 instructions.
Maximum Pump Size:
MDX-R3 is rated for a maximum of 132 GPM (500 LPM). While system flow rate will vary with
pump size and the Total Head Loss for a given system, virtually any modern pump is capable of
exceeding this limit, therefore it is the responsibility of the system designer to make sure it is not
possible to exceed 132 GPM (500 LPM).
NOTICE
In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a
flow rating capable of the full flow of the pump(s) for the specific suction system.
MDX-R3 and SDX2 must be installed in accordance with Paramount’s written instruction
manual, and in conformity with applicable Federal, State, Local and Swimming pool industry
building and safety codes.
WARNING
Plumbing of the included enlarged suction element (13” of 4” pipe) to the 4" port
of the MDX-R3 is required. After the enlarged suction element, the included reducer
adapter may then be used to reduce the pipe size to 2½”. A 3” coupler may be attached to
the outside diameter of the reducer or a 4” coupler directly to the enlarged suction element
for systems where the flow through the MDX-R3 is intended to exceed 90 GPM. Use of 2½”
pipe minimum throughout the suction side of the system is strongly encouraged for
optimum performance. For your convenience, Paramount Pool & Spa Systems includes the
enlarged suction element, and the reducer adapter with the MDX-R3. To order separately, please
see page 11 for the part number.
NOTICE
NOTICE
The use of two 45˚ in place of a 90˚ allows for the best debris removal and minimizes large
debris from getting caught in the line.
0.00
0.20
0.40
0.60
0.80
1.00
1.20
30
(114)
40
(151)
50
(189)
60
(227)
70
(265)
80
(303)
90
(341)
100
(379)
110
(416)
120
(454)
130
(492)
140
(530)
150
(568)
160
(606)
170
(643)
180
(681)
190
(719)
200
(757)
210
(795)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
FLOW HEAD LOSS CURVE
FLOW GPM (LPM)
HEAD LOSS (INHG)
HEAD LOSS (CMHG)
MDX-R3 INSTALLATION WHEN USING A SKIMMER
SDX
2ND SUCTION OUTLET
MV FUSE IN
CANISTER
50mm
50mm
50mm
ENLARGED SUCTION ELEMENT
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE
IF NOT USING HYDROSTAT
PLUG 50mm PORT
TO PUMP & SKIMMER
BYPASS
WITH CANISTER AND MV FUSE
MV FUSE
DECK SIDE
50mm
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE
ENLARGED SUCTION ELEMENT
METHOD 1 WITH DECK CANISTER AND MV FUSE
IF NOT USING HYDROSTAT
PLUG 50mm PORT
50mm
SDX
2ND SUCTION OUTLET
TO PUMP &
SKIMMER BYPASS
50mm
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE
50mm
ENLARGED SUCTION ELEMENT
WITH CANISTER WITHOUT MV FUSE
IF NOT USING HYDROSTAT
PLUG 50mm PORT
50mm
SDX
2ND SUCTION OUTLET TO PUMP &
SKIMMER BYPASS
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE
WITHOUT CANISTER AND WITHOUT MV FUSE
50mm
ENLARGED SUCTION ELEMENT
IF NOT USING HYDROSTAT
PLUG 50mm PORT
50mm
SDX
2ND SUCTION OUTLET
TO PUMP &
SKIMMER BYPASS
*Note: Canister requires 40mm equalizer line through pool wall. (Not Shown)
*Note: Canister requires 40mm equalizer line through pool wall. (Not Shown)
WITH CANISTER WITHOUT CANISTER
TO PUMP
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE.
65mm OR 90mm
ENLARGED SUCTION ELEMENT
WITH CANISTER AND MV FUSE
IF NOT USING HYDROSTAT
PLUG 2" PORT
MV FUSE IN
CANISTER
IF NOT USING HYDROSTAT
PLUG 2" PORT
65mm OR 90mm
WITH CANISTER WITHOUT MV FUSE
ENLARGED SUCTION ELEMENT
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE.
TO PUMP
WITH CANISTER
WITH CANISTER
WITHOUT CANISTER
WITHOUT CANISTER
TO PUMP
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE.
65mm OR 90mm
ENLARGED SUCTION ELEMENT
WITH DECK FUSE
IF NOT USING HYDROSTAT
PLUG 2" PORT
MV FUSE DECK SIDE
TO PUMP
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE.
65mm OR 90mm
WITHOUT CANISTER, WITHOUT MV FUSE
ENLARGED SUCTION ELEMENT
IF NOT USING HYDROSTAT
PLUG 2" PORT
*Note: Canister requires 40mm equalizer line through pool wall. (Not Shown)
*Note: Canister requires 40mm equalizer line through pool wall. (Not Shown)
ENLARGED SUCTION ELEMENT
IF NOT USING HYDROSTAT
PLUG 2" PORT
SDX
2ND SUCTION OUTLET
2 1/2"
2 1/2"
TO PUMP
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE.
WITH CANISTER AND MV FUSE
MV FUSE IN
CANISTER
IF NOT USING HYDROSTAT
PLUG 2" PORT
ENLARGED SUCTION ELEMENT
2 1/2"
2 1/2"
TRUNK LINE MUST BE
SIZED TO MEET MAXINUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE.
TO PUMP
SDX
2ND SUCTION OUTLET
WITH DECK SIDE MV FUSE
MV FUSE DECK SIDE
SDX
2ND SUCTION OUTLET
2 1/2"
2 1/2"
ENLARGED SUCTION ELEMENT
IF NOT USING HYDROSTAT
PLUG 2" PORT
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE.
TO PUMP
WITH CANISTER, WITHOUT MV FUSE
TO PUMP
TRUNK LINE MUST BE
SIZED TO MEET MAXIMUM
VELOCITY REQUIREMENTS
FOR SUCTION PLUMBING
PER LOCAL CODE.
SDX
2ND SUCTION OUTLET
2 1/2"
ENLARGED SUCTION ELEMENT
WITHOUT CANISTER, WITHOUT MV FUSE
IF NOT USING HYDROSTAT
PLUG 2" PORT
2 1/2"
*Note: Canister requires 1½” equalizer line through pool wall. (Not Shown)
MDX-R3 INSTALLATION WITHOUT SKIMMER INSTALLED
MDX-R3 INSTALLATION WITHOUT SKIMMER INSTALLED
Fig. 3
UP Arrow
Solid Gasket
Fiberglass Shell
Fig. 2
SUMP INSTALLATION TO SHELL
1.
Apply sealing compound to top surface of MDX-R3
sump flange.
2.
From outside of pool shell, align sump with screw
holes in mounting ring and sweep ninety pointing to
side of pool shell.
3.
Install (12) 12 x 1” flat head screws every hole.
(Fig. 1)
4.
Secure 2nd Suction Outlet fitting through sidewall in
desired locations.
FIBERGLASS SHELL
Fig. 1
SDX2 Fiberglass Installation
1.
Select the installation location for the SDX2 drain.
(Additional SDX2 drain may be used.)
2.
For Fiberglass Wall: Cut one 4.5” (11.43 cm) hole
using a 4.5” (11.43 cm) hole saw.
3.
Install the SDX2 Bulkhead Fitting with the “UP” arrow
located at the top. (Fig. 3)
For Fiberglass Shells: (Fig. 2)
a.
Place the solid Gasket with the smooth side
against the Bulkhead Fitting flange. (Silicone
adhesive may be substituted for the Gasket if
preferred.)
b.
Mount the SDX2 Bulkhead Fitting in the hole with
the UP arrow at the top of each fitting.
c.
Secure with the SDX2 Nut.
4.
Make plumbing connection between 2nd Suction
Outlet and MDX-R3 Sump by connecting to side outlet
of tee as shown in install methods 1on page 2. Pipe
must be equal diameter to circulation line.
FIBERGLASS INSTALLATION
Fiberglass Cover Assembly (Fig. 4)
1. Prior to installing the Support, apply adhesive to the
non-ribbed side of the two notched gaskets.
2. Align the gaskets with the alignment tabs and
screw holes, then press the gaskets onto the
Bulkhead Fitting and the Bulkhead Support.
3. Align the SDX2 Vinyl/Fiberglass Support with
the alignment tab located at the top of the SDX2
Bulkhead Fitting. (Fig. 3)
4. Install five(5) self-tapping screws (Fig. 5) through
the SDX2 Bulkhead Support with the
T25 Security Screw Driver (Fig. 6). Secure the
screws without over tightening.
5. Align the SDX2 Cover with the SDX2 Support
holes.
6. Install three (3) security screws through the SDX2
cover. Secure the screws without over tightening.
Fig. 5 Fig. 6
Fiberglass
Shell
Solid Gasket
Fig. 4
HYDROSTATIC FITTING: The hydrostatic port inside the MDX-R3 Sump is
equivalent to a 2” Threaded Female Adapter and a 63mm Slip Fitting Outside the
MDX-R3 Sump. This port is for the purpose of a hydrostat only. Paramount recommends
the use of the 2” thread plug provided. Do not use check valves here that are prone to sticking open causing the
need to open the drain cover exposing a suction risk. If a hydrostat is not used, plug this port from bottom with pipe
and cap. Do not install any suction equipment (pump) to this port!
NOTICE
With Pressure Plugs
Pressure should remain on the system through
construction until right before filling with water.
4" PLUG
2 1/2" PORT
2" HYDROSTAT PLUG
MDX-R3 PRESSURE TESTING
Pressure Test-READ BEFORE INSTALLATION:
New Style Test Plug
The 4” pressure test plugs (005-252-1610-00)
use an o-ring to make the seal.
Wrap once with Teflon tape to prevent plastic
threads from binding. Insert plug into threaded
socket. Use an adjustable wrench, a 1½” 12pt
socket or pliers on lug and tighten by hand until
snug. Over tightening may cause parts to break.
SUMP INSTALLATION
SUMP INSTALLATION TO SHELL BEFORE SETTING POOL
Fig. 7
1.
Sand and clean this bottom surface area well
(see arrow). This is where the gasket will seal.
(Fig. 7)
2.
Glue gaskets to the face of the sump with
RTV Silicon glue. Be sure to line up all gasket
holes with the corresponding hole in the
sump. (Fig. 8)
TO POOL WALL
SCREW HOLES
Fig. 8
Assemble the Drain PRIOR to Adding Water -
See Illustration on Page 9:
1.
Remove 4” pressure plug.
2.
Install funnel assembly (#3) onto sump (#9) and
secure with 4 (four) security screws (#2) with
screw driver security T25 (#24).
Fig. 9
3.
Line up ninety of the sump to face the side of
the pool. Using two people or by reaching
thru from the inside of the pool position the
sump so the screw holes line up keeping the
sweep ninety facing the side of the pool.
Using the 12 flathead screws affix the sump to
the mounting ring. (Fig. 8)
3.
Install the cover (#1) onto the funnel assembly
(#3) and secure with 3 (three) security screws
(#2).
Release pressure on the
system before removing plugs
WARNING
MDX-R3 FIBERGLASS WINTERIZATION
WITH CANISTER WITHOUT CANISTER
If vacuum relief suction outlets are located below freeze
line skip steps 1 and 2.
1. Remove grate from second suction and install a
13-¾ blow through plug and blow line to achieve
airlock.
2. If 3rd suction line is installed remove grate, install
13-¾ blow-through plug and blow line to achieve
airlock.
3. Go to canister instructions step 1 - 5 below.
4. If vent tube is installed, install blow through plug
and blow line to achieve airlock. Repeat vacuum out
canister. Then complete canister step 5.
If vacuum relief suction outlets are located below freeze
line skip steps 1 and 2.
1. Remove grate from second suction and install
13-¾ blow through plug and blow line to achieve
airlock.
2. If 3rd suction line is installed remove grate, install
13-¾ blow-through plug and blow line to achieve
airlock.
3. If vent line is installed in main suction line, plug vent
line and install blow through plug in pump inlet and
blow line to achieve airlock.
4. Lastly, blow vent line to achieve airlock.
VENT TUBE WARNING LABELS
Included in each MDX-R3 are two warning labels that
need to be placed on the pool equipment if the pool is
to be winterized and has a vent tube on any of the drains
plumbed on the pool. Attach the smaller label to the vent
pipe where it terminates to atmosphere. (See Fig. 9)
Attach the larger label to the control panel next to the
controller for the pump with the vent tube plumbed to it.
(See Fig. 10)
Fig. 9
Fig. 10
WARNING
When starting pool after winterization, remove plug
from atmospheric vent pipe before energizing pool
pump(s)!
Test vent by blocking drain. Air should enter the pipe
and cause the pump to cavitate releasing the suction on
the drain block.
Ave RtIssemeNt
Lors du démarrage de la piscine après l’hiver, retirez le
bouchon du tuyau de ventilation atmosphérique avant
de mettre la pompe (s) de la piscine en marche!
Testez la ventilation en bloquant le drain. L’air doit entrer
dans le tube et provoquer la cavitation de la pompe et
relâcher l’aspiration sur le bloc de drainage.
001-025-8216-00 REV 051314
WARNING
High Suction Atmospheric Vent!
Do not operate pool pump(s) with this pipe plugged!
If necessary to plug vent to winterize the pool do not
restart pool until plug is removed
Ave RtIssemeNt
Ventilation atmosphérique à grande succion!
Ne pas faire fonctionner la pompe (s) de la piscine
avec un bouchon dans ce tuyau!
S’il est nécessaire mettre un bouchon pour hiverner
la piscine, ne pas redémarrer la piscine jusqu’à ce
que le bouchon soit enlevé. 001-025-8215-00 REV 043014
004-282-2241-XX MDX-R3 FOR FIBERGLASS POOLS
Item Part Number Description
1 005-252-2110-XX Cover (XX = Color Code)
2 ** Screw No. 10 X 7/8 Security Head
3 005-252-8234-XX Funnel Assembly (Includes Support, Cover Screw and Adapter) **
4 ** Screw No. 12 X 1 Pil Flt Hd.
5* 005-252-2048-00 Mounting Ring
6 005-252-0010-00 Gasket Vinyl (2 pcs)
7 005-252-1605-00 Plug 2” NPT (6 pcs)
8 005-252-1045-00 Funnel Adapter
9 005-252-2009-00 Sump
10 005-252-1610-00 4” Plug with O-Ring
11* ** 50mm Pipe - Not Included - Cap If Not Used
12* ** 50mm Cap - Not Included - Cap If Not Used
13 005-252-5524-00 Enlarged Suction Element
14 ** Pipe 10” Long
15 ** 4” Elbows
16 005-252-2550-00 Coupler Reducer 4” X 2½”/3”
* 005-282-0842-00 Screw Pack Fiber (19 pc)
17 004-182-2212-XX SDX2 High Flow Safety Drain - Fiberglass (2 pk) (XX = Color Code)
18 005-252-0821-00 Screw: 10 X 1 1/4” TORX W/PIN SS B (12 pcs)
19 005-252-2086-XX SDX2 Cover w/ Screws Vinyl/Fiberglass
20 005-252-0816-00 Screw: 12-14
X
1” B (12 pcs)
21 005-252-2068-00 SDX2 Support Vinyl/Fiberglass
22 005-252-0072-00 SDX2 Gasket Vinyl/Fiberglass
23 005-252-2035-00 SDX2 Bulkhead Vinyl/Fiberglass 2½”
24 005-252-0074-00 SDX2 Bulkhead Gasket Fiberglass
25 005-252-2090-00 SDX2 Bulkhead Nut
26 005-252-0895-00 T25 Security Screw Driver
* Not part of MDX-R3
1
23
4
5
6
7
8
9
10
11
12
15
15
16
13
14
14
2
3
5
7
9
10
TCP
13
1
4
6
8
11
12
R1
14
17
18
20
19
21
22
23
24
25
26
2
3
5
7
9
10
TCP
13
1
4
6
8
11
12
R1
14
17
18
20
19
21
22
23
24
25
26
Replace within 05 installed years

Other manuals for MDX-R3

6

Other Paramount Fitness Lighting Equipment manuals

Paramount Fitness MDX2 retro User manual

Paramount Fitness

Paramount Fitness MDX2 retro User manual

Paramount Fitness MDX-R3 Programming manual

Paramount Fitness

Paramount Fitness MDX-R3 Programming manual

Paramount Fitness PARASCOPE User manual

Paramount Fitness

Paramount Fitness PARASCOPE User manual

Paramount Fitness MDX-R3 Programming manual

Paramount Fitness

Paramount Fitness MDX-R3 Programming manual

Paramount Fitness ECO POOL 006-527-6316 Series User manual

Paramount Fitness

Paramount Fitness ECO POOL 006-527-6316 Series User manual

Paramount Fitness Paraskim V Programming manual

Paramount Fitness

Paramount Fitness Paraskim V Programming manual

Paramount Fitness SDX 2 User manual

Paramount Fitness

Paramount Fitness SDX 2 User manual

Paramount Fitness MDX-R3 Programming manual

Paramount Fitness

Paramount Fitness MDX-R3 Programming manual

Paramount Fitness ECOSYSTEM User manual

Paramount Fitness

Paramount Fitness ECOSYSTEM User manual

Paramount Fitness MDX2 retro User manual

Paramount Fitness

Paramount Fitness MDX2 retro User manual

Paramount Fitness Paraskim V Programming manual

Paramount Fitness

Paramount Fitness Paraskim V Programming manual

Paramount Fitness MDX-R3 User manual

Paramount Fitness

Paramount Fitness MDX-R3 User manual

Paramount Fitness MDX DEBRIS REMOVAL SYSTEM User manual

Paramount Fitness

Paramount Fitness MDX DEBRIS REMOVAL SYSTEM User manual

Popular Lighting Equipment manuals by other brands

Vision & Control A-DIF-90x120-G525-SL Instructions for use

Vision & Control

Vision & Control A-DIF-90x120-G525-SL Instructions for use

John Lewis Outdoor Moroccan user guide

John Lewis

John Lewis Outdoor Moroccan user guide

MS Sedco AccuGuard HP2 installation instructions

MS Sedco

MS Sedco AccuGuard HP2 installation instructions

RZB HB 302 Instruction

RZB

RZB HB 302 Instruction

Smitson JM-LED02 user manual

Smitson

Smitson JM-LED02 user manual

Middle Atlantic Products Forward instruction sheet

Middle Atlantic Products

Middle Atlantic Products Forward instruction sheet

Luxibel LX152 user manual

Luxibel

Luxibel LX152 user manual

Qlightec S150US user manual

Qlightec

Qlightec S150US user manual

HERA PD 60 DYNAMIC WHITE SERIES User manual & installation guide

HERA

HERA PD 60 DYNAMIC WHITE SERIES User manual & installation guide

Ritelite COBRA Operating/safety instructions

Ritelite

Ritelite COBRA Operating/safety instructions

Solid Apollo SA-PROF-CROWN-78 product manual

Solid Apollo

Solid Apollo SA-PROF-CROWN-78 product manual

Clas Ohlson 36-4190 operating instructions

Clas Ohlson

Clas Ohlson 36-4190 operating instructions

SLV 113150/51 operating manual

SLV

SLV 113150/51 operating manual

Connect Pro MT033-CP manual

Connect Pro

Connect Pro MT033-CP manual

MegaLite Drama W50 LED user manual

MegaLite

MegaLite Drama W50 LED user manual

Expolite Tour-BAR 64 Pre-Manual

Expolite

Expolite Tour-BAR 64 Pre-Manual

PowerSmith PWLR010CM Operator's manual

PowerSmith

PowerSmith PWLR010CM Operator's manual

Mark SIDIUS ZOOM 555 user manual

Mark

Mark SIDIUS ZOOM 555 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.