manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PeakTech
  6. •
  7. Measuring Instrument
  8. •
  9. PeakTech 9017 User manual

PeakTech 9017 User manual

Other PeakTech Measuring Instrument manuals

PeakTech 5060 User manual

PeakTech

PeakTech 5060 User manual

PeakTech 5170 User manual

PeakTech

PeakTech 5170 User manual

PeakTech 3296 User manual

PeakTech

PeakTech 3296 User manual

PeakTech 5310 A User manual

PeakTech

PeakTech 5310 A User manual

PeakTech 2170 User manual

PeakTech

PeakTech 2170 User manual

PeakTech 2800A User manual

PeakTech

PeakTech 2800A User manual

PeakTech 5165 User manual

PeakTech

PeakTech 5165 User manual

PeakTech 2675 User manual

PeakTech

PeakTech 2675 User manual

PeakTech 1610 User manual

PeakTech

PeakTech 1610 User manual

PeakTech 5305 User manual

PeakTech

PeakTech 5305 User manual

PeakTech 1235 User manual

PeakTech

PeakTech 1235 User manual

PeakTech 1125 User manual

PeakTech

PeakTech 1125 User manual

PeakTech 3430 User manual

PeakTech

PeakTech 3430 User manual

PeakTech 5307 User manual

PeakTech

PeakTech 5307 User manual

PeakTech 2790 User manual

PeakTech

PeakTech 2790 User manual

PeakTech 3349 User manual

PeakTech

PeakTech 3349 User manual

PeakTech 3203 User manual

PeakTech

PeakTech 3203 User manual

PeakTech TK-60 User manual

PeakTech

PeakTech TK-60 User manual

PeakTech 5201 User manual

PeakTech

PeakTech 5201 User manual

PeakTech 1650 User manual

PeakTech

PeakTech 1650 User manual

PeakTech 4135 User manual

PeakTech

PeakTech 4135 User manual

PeakTech 2705 User manual

PeakTech

PeakTech 2705 User manual

PeakTech 5310 User manual

PeakTech

PeakTech 5310 User manual

PeakTech 4350 User manual

PeakTech

PeakTech 4350 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1. Operating safety precautions
This product complies with the requirements of the following European
Community Directives: 89/336/EC (Electromagnetic Compatibility).
* Introduction
This electronic measuring instrument is a high technology products made
under strict quality control. We guarantee its exceptional precision and
utmost reliability. To ensure safe operation of this instrument, be sure to
follow the warning and precautions provided as bellow.
Warning !
* Do not use this product or equipment connected to it in an explosive,
ignitable, or flammable atmosphere, as this will result in the risk of
explosion.
* Do not connect this product to a piece of equipment or cable having
a voltage with respect to ground on its chassis, as such connection
can result in the risk of electrical shock.
* Use a proper Battery charger for charging internal rechargeable
battery pack.
Caution
* Do not remove the case cover, as this can risk failures or loss of
performance.
* Do not allow water to enter the product. This product is not waterproof.
* If condensation forms on this product due to a sudden change in
temperature, use this product only after allowing it to dry sufficiently.
-19-
6.3. Weitere Meßfunktionen
6.3.1. Spitzenwerthaltefunktion
Die Spitzenwerthaltefunktion dient dem „Einfrieren“ des höchsten
Meßwertes und erleichtert somit das Installieren von Antennen-
systemen. Bei Messung eines neuen Spitzenwertes wird der alte
Wert automatisch überschrieben. Für Informationen zur Aktivierung
dieser Funktion siehe Abschnitt 6.1.4.
6.3.2. Akustische Überwachung der Signalstärke (Monitorbetrieb)
Die akustische Signalüberwachung gibt Aufschluß über die Signal-
stärke des Eingangssignals und erleichtert somit die Installation und
Ausrichtung von Antennensystemen ganz beträchtlich. Das 1kHz-
Tonsignal variiert in Abhängigkeit von der Signalstärke des Eingangs-
signals. Für Informationen zur Aktivierung dieser Funktion siehe
Abschnitt 6.1.4.
6.3.3. Automatische Wiederwahl der vor dem Ausschalten des Gerätes
benutzten Einstellungen beim erneuten Einschalten des Gerätes
Beim Einschalten wählt das Meßgerät automatisch wieder den
vor dem Ausschalten zuletzt benutzten Kanal und dessen Einstel-
lungen.
6.3.4. LCD-Hintergrundbeleuchtung
Die Hintergrundbeleuchtung erleichtert das Ablesen der Meßwerte
unter ungünstigen Lichtverhältnissen. Die Hintergrundbeleuchtung
wird mit der Funktionstaste LAMP ein- und ausgeschaltet.
6.3.5. Abschaltautomatik
Die interne Abschaltautomatik bewirkt eine automatische Abschal-
tung des Gerätes ca. 10 Minuten nach der letzten Betätigung einer
Taste. Sie bewirkt auch ein Abschalten des Gerätes bei ungenü-
gender Batteriespannung. Beim erneuten Einschalten wählt das
Gerät automatisch den vor dem Ausschalten zuletzt benutzten
Kanal und dessen Einstellungen.
-16-
6.2. Pegelmessungen
Pegelmessungen können sowohl mit voreingestellten, gespeicherten Werten
als auch durch Eingabe eigener Werte durchgeführt werden.
6.2.1. Pegelmessung mit voreingestellten, gespeicherten Werten
* Auf die Funktion „Aufruf ge-
speicherter Werte“ durch
Drücken der CALL-Taste
umschalten und mit den UP/DOWN-
Tasten den Kanal mit den gewünschten gespeicherten
Werten aufrufen.
* Meßkabel an Eingangsbuchse des
LNB-Verstärkers anschließen und
Meßwert in der LCD-Anzeige
ablesen.
6.2.2. Pegelmessung durch Eingabe eigener Werte
* Mit der SHIFT-Taste auf die
Frequenzmeßfunktion um-
schalten und zu messende
Frequenz mit den UP/DOWN-Tasten einstellen (siehe
Abschnitt 6.1.3 „Änderung der Meßfrequenz“)
* Mit der SHIFT-Taste die erforderlichen
Einstellungen (Funktionen) Ausgangs-
pegel und Meßeinheit wählen und mit
Tasten UP/DOWN die gewünschten
Meßkriterien einstellen.
* Den Wert des Eingangspegels vom Display ablesen.
6.2.3. Messung des LNB-Stromwertes
Zur Messung des LNB-Stromwertes wie beschrieben verfahren:
* Mit der SHIFT-Taste auf Strom-
messung umschalten.
* Mit den UP/DOWN-Tasten die
Funktion "mA DC" anwählen.
* Meßwert in der LCD-Anzeige ablesen.
* Zur Rückkehr zu normaler Meßfunktion Taste CALL 2 x
drücken. -15-
2. Introduction
This professional SAT Level Meter has been designed for the installation and
maintenance of analogue and digital satellite TV system. The inside circuitry
and mechanical design has been carefully developed in order to obtain very
light, slim typed field strength meter. To allow the installer to work in the best
conditions, it is also offering built-in LNB powering and hang-on-the neck
type carrying case. The LCD display with Back-light is shown several kinds
of information such as Frequency, Measuring level, Function, units and bar
graph. The compact metal cabinet will be a right choice for heavy-duty field
use. It is a real instrument to measure, verify and optimize satellite TV
systems at any stage of installation.
2.1. Features
* Handheld, portable SATELLITE IF SIGNAL STRENGTH METER
* PLL tuning control for Frequency Selection (From 900 MHz to
2,150 GHz)
* 13V, 18V, 22kHz and DiSEqCTM1.0 leveled signal output for
selecting LNB
* LNB Current measurement (Up to 250mA)
* Built in Rechargeable Battery pack for powering LNB
* Auto power off
* 99 Favorite Channel memory
* Peak holder function for detecting Max. Input level Display
* Buzzer for Acoustic signal strength monitoring
* Multi LCD display with Back light
* Last condition Store & memory
* Key Entry control
* Deluxe HANG-ON-NECK type CARRYING CASE for hand-free use
3. Technical Specifications
Measuring Frequency Range 900 to 2,150 GHz (First IF Frequency)
Frequency Tuning Resolution 250 kHz
Frequency Tuning Method PLL Frequency Synthesizer
-20-
Level Measurement
- Measuring Range 40 to 80 dBuV (-67 to –27 dBm)
- Resolution 0.1 dB
- Accuracy ±3 dB (0 to 40°C)
- Bandwidth 27 MHz (- 3 dB)
RF Input F type , 75 ohm
Output signal to Antenna System 13 V, 18 V, 22 kHz, DiSEqC 1.0 signal
LNB Current Measurement 0 to 250 mA with 0.1 mA resolution
Favorite Channel Memory
- Number of channels 99
- Storable Items Frequency: 900MHz to 2,150GHz in
250kHz step
Function: Normal, Peak holder,
Sound Unit of Level: dBuV, dBm,
mADC
Output signal to LNB: 13V, 18V, 13V +
22kHz, 18V+22kHz, DiSEqC (A,B,C,D)
Auto power off Preset to 10 Minutes
Internal Power
- Capacity of Rechargeable
battery 12V/1200mA AH (MH)
- Battery Life 2 HRS at 250mA LNB Load
Power requirement for charging DC12 V / 500 mA (Charge & Adaptor)
Display Multi LCD Display with Backlight, Fre-
quency, Channel, Level, dBuV, dBm,
mADC, Function, Battery level, Output
Signal for Antenna, Bar Graph
-21-
6.1.10.Messung des Eingangspegels mit Hilfe gespeicherter Daten
(Kanäle)
* Zur Umschaltung auf die Kanal-
wahlfunktion Taste CALL drücken.
Es blinkt das Symbol CH.
* Mit den UP/DOWN-Tasten Kanal
mit den gewünschten gespeicherten
Daten anwählen.
* Gewählten Kanal durch erneutes
Drücken der Taste CALL aktivieren.
* Wenn CH blinkt, wird der vorher gespeicherte Wert und
die Daten für die Messung angewendet.
6.1.11.Batteriezustandsanzeige
Die Batteriezustandsanzeige (siehe Tabelle) gibt Aufschluß über
den Ladezustand der Batterie:
Batteriesymbol Max. Betriebsdauer
Voll geschwärzt (3 Balken) ca. 2,0 Stunden
2 Balken schwarz ca. 1,0 Stunden
1 Balken schwarz ca. 0,5 Stunden
blinkendes Symbol Batterie muß geladen
werden. Ein Summer
ertönt und das Gerät
schaltet automatisch ab.
-14-
6.1.8. Umschaltung auf einen anderen Kanal
* Mit der Taste SHIFT auf die Kanal-
wahlfunktion umschalten. In der LCD-
Anzeige blinkt CH.
* Gewünschten Kanal (01...99) durch
entsprechendes Drücken der UP/DOWN-
Tasten wählen.
* Zur Speicherung des gewählten Kanals
Taste STORE 2 x drücken. Das Um-
schalten auf eine andere Meßfunktion
erfolgt mit der Taste SHIFT.
6.1.9. Speicherung von geänderten Einstel-
lungen auf einem Kanal.
Nach Eingabe aller erforderlichen Parameter
für die einzelnen Meßfunktionen können
diese in einem beliebigen Kanal (01...99)
gespeichert werden.
* Die in den Abschnitten 6.1.3 bis 6.1.7 beschriebenen
Einstellungen durchführen.
* en zur Speicherung der Daten gewünsch-
ten Kanal eingeben (siehe Abschnitt
6.1.8).
* Daten durch 2-maliges Drücken der
Taste STORE im aufgerufenen Kanal
speichern.
* Zur Speicherung von Daten auf weiteren Kanälen neuen
Kanal wählen (Abschnitt 6.1.8) und wie oben beschrieben
verfahren.
* Das Gerät wurde werkseitig mit den üblichen Grundein-
stellungen programmiert. Die Einstellung und Speicherung
von Daten auf den einzelnen Kanälen bleibt den Erforder-
nissen des Kunden vorbehalten.
-13-
Environmental Conditions
- Operating Temperature Range 0 to 40 °C
- Operating Humidity Range 30 to 85 % RH
- Storage Temperature Range -10 to 50 °C
Dimensions and Weight 180(W) x 75(H) x 150(D) mm
Approx. 1.5 kg
Supplied Standard Accessories 1 x Battery Charger (12V / 500mA)
1 x Carrying Case
1 x User’s Manual
4. Initial Inspection
This instrument was carefully inspected both mechanically and electrically
before shipment. It should be physically free of damage. To confirm this, the
instrument should be inspected for physical damage in transit. Also, check
for supplied accessories.
4.1. Charging and Discharging Instruction
New batteries are supplied in an uncharged state. To ensure the maximum
battery performance, a new battery (or long time not-used-battery) should be
charged for at least 10 hours before use.
a. A new battery will require several full-charge/discharge cycles in
order to achieve its optimum performance. After 1st full charge, use
battery until full discharge level, and 2nd charge to full level, Repeat
this cycle several times before starting the main use of battery.
b. Best battery performance will be achieved when you regularly
charge and discharge batteries.
c. If left unused, a fully charged battery will discharge itself in approx. one
month.
** Please refer to “8.2 Battery Charging, page 4-1“ for the details of
charging method.
-22-
4.2. Cooling and Ventilation
No special cooling and ventilation is required. However, the instrument
should be operated where the ambient temperature is maintained.
5. Operation Procedure
5.1. Front Panel Description
5 4 3 1 2
1. Power; Power on / off (Momentary switch). Turning
on the power with beep sound when the switch is pressed.
2. Input Terminal; Accepts IF signal from LNB. Outputs signal (13V, 18V,
13V+22kHz, 18V+22kHz and DiSEqC signal) to Antenna system (LNB or
Switch Box).
Caution: Maximum input is as follows:
Signal: 100dBuV
DC Voltage: 50V
Excessive voltage can damage to internal
circuit.
-23-
6.1.6. Wahl und Einstellung des DiSEqC-
Ausgangs (Digitales Satellitenempfang-
Steuersignal)
Das DiSEqC 1.0 Signal dient der Wahl der für den LNB-
Verstärker von Mehrfach-Antennensystemen erforderlichen
Ausgangsspannung. Zur Einstellung der Ausgangsspannung für das
jeweilige Antennensystem oder den LNB-Verstärker, Spannungs-
erfordernisse für das jew. System überprüfen (DiSEqC A, B, C, D).
* Mit der SHIFT-Taste Gerät auf DiSEqC-Ausgang
umschalten. In der LCD-Anzeige blinken die ent-
sprechenden Anzeigen.
* Mit den UP/DOWN-Tasten erforderliches Ausgangs-
signal wählen.
* Ausgangssignal durch 2-maliges Drücken der
STORE-Taste speichern und mit der SHIFT-Taste auf
eine andere Meßfunktion umschalten.
Hinweis: Die DiSEqC-Pegel 1,0 Steuer-
Befehle bestehen aus DiSEqC-infor-
mationen <A, B, C, D> und einem Ton-
burst-Steuersignal <SA (AC), SB (BD)>
die einer konventionellen 13 V/18 V DC-
Spannung mit 22 kHz-Informationen zur
Steuerung einer 4-fach Eingangsweiche
(Steuerung durch DiSEqE-Befehle) bzw.
einer 2-fach Weiche (Steuerung durch
Tonburst- oder DiSEqC-Befehle über-
Lagert sind.
6.1.7. Wahl der Meßeinheit
Die Meßwertanzeige erfolgt entweder in dBuV/
dBmV (Pegelwert) oder mA DC. Gewünschte
Meßeinheit wie beschrieben wählen:
* Mit der SHIFT-Taste auf die Funktion „Wahl der
Meßeinheit“ umschalten.
* Gewünschte Meßeinheit (dBµV, dBmV oder
mADC) mit den UP/DOWN-Tasten wählen.
Messung durchführen.
* Zur Umschaltung auf eine andere Meßfunktion-
Taste SHIFT erneut drücken.
* Wenn mA DC gewählt wurde, wird die
Stromversorgung des LNB angezeigt.
-12-
6.1.4. Wahl der Meßfunktionen
Zur Wahl der einzelnen Meßfunktionen (Normal,
Spitzenwerthaltefunktion (Peak), Ton wie beschrieben
vorgehen:
* SHIFT-Taste drücken. Es blinken
die Funktionswahltasten FUNCTION.
* Gewünschte Meßfunktion (Spitzenwert-
haltefunktion, akustischer Monitorbetrieb,
normaler Meßbetrieb) mit den UP/DOWN-
Tasten wählen. Das entsprechende Funk-
tionssymbol leuchtet auf (bei normalem Meßbetrieb
leuchtet kein Funktionssymbol).Der angezeigte
Spitzenwert wird bei Messung eines höheren
Wertes automatisch überschrieben.
* Zur Speicherung des Meßwertes Taste
STORE 2 x drücken. Das Umschalten auf
eine andere Meßfunktion erfolgt mit der
Taste SHIFT.
6.1.5. Anschluß des Satellitenpegelmeßgerätes an ein
Antennensystem
Ausgangsspannung am Pegelmeß-
gerät auf den für das Antennen-
system bzw. den LNB-Verstärker erforderlichen Wert einstellen
(12 V, 18 V, bzw. 13 V+22 kHz oder 18 V+22 kHz).
Dazu wie beschrieben vorgehen:
* Mit der Shift-Taste auf die Funktion
"Ausgangsspannung" umschalten.
Die entsprechenden Anzeigen blinken.
* Erforderliche Ausgangsspannung mit
den UP/DOWN-Tasten einstellen.
* Zum Speichern der eingestellten
Ausgangsspannung Taste STORE 2 x
drücken. Zur Umschaltung auf eine
andere Meßfunktion Taste SHIFT
drücken.
-11-
3 Function;
- Set the frequency, Function, Output
Signal and units.
- Store the function and data for
desired channel and call the stored
channel.
- Turning on back-light.
Use to select the function of Up/Down key.
(Frequency, Channel, Function, Output signal, unit)
Use to store the desired conditions of each channel
(push two times) (Frequency, Function, Audio Sub-
carrier, measuring unit) Use to change the measuring
conditions in selected channel momently (push one
time)
Use to call stored channel
Use to turn on and off back light
Up
Down
Use to change the value in selected function by key.
•Change of Frequency (From 900MHz to 2,150GHz
in 250kHz step)
•Change of Channel (CH 01,02,… up to 99)
•Change of function (Normal, Peak holder, Sound)
•Change of Output signal
(13V,18V,13V+22kHz,18V+22kHz,DiSEqC)
•Change of measuring unit (dBuV, dBm, mADC)
4. LCD Display; Displays measurement level and various information.
5. DC INPUT for charging internal battery pack;
Accepts external DC power from AC adaptor and Cigar socket of Car for
charging internal battery pack. When the AC adaptor is used for charging,
DC 12V500 mA is required. The input power jack could be accepting with
center plus (+).
-24-
5.2. LCD Panel Description
1
^7
2 6
3
4 5
1. Bar-Graph;
Displays signal level. Minor division
indicates 1 dBuV. Same quantities of bar
will be displayed with input level
from 40dBuV to 80dBuV.
2. Function (Peak holder, Sound, Battery level)
Displays selected function (Peak, Sound) and
the level of internal battery pack.
3. Channel
Displays selected channel number
4. Level
Displays signal level with dBuV or dBm,
and current value to LNB with mADC.
5. Frequency
Displays selected IF frequency
-25-
6.1.2. Anschluß des Satelliten-
meßgerätes an Mehrfach-
Empfangssysteme
Abb. 3-3 zeigt die Anschlußkon-
figuration für den Anschluß an
2 LNB- oder Antennensysteme.
Ausgang des Pegelmeßgerätes
an die Antennenbuchse oder
den Ausgang der Weiche über
einen DC-Block anschließen (siehe Abschnitt
6.1.5 "Anschluß des Pegelmeßgerätes an das
Antennensystem.
Abb. 3-3
6.1.3. Änderung der Meßfrequenz
Die gewünschte Frequenz kann un-
mittelbar nach Einschalten des
Gerätes oder nach erfolgter Kanal-
wahl gewählt werden. Die Eingabe der
Frequenz (900 MHz – 2,150 GHz in
in 250 kHz-Schritten) erfolgt mit den
UP/DOWN (AUF/AB) Tasten. Zum
Speichern der eingegebenen Frequenz
Taste STORE 2 x drücken oder zur Um-
schaltung auf eine andere Meßfunktion
Taste SHIFT drücken.
-10-
5. Frequenzanzeige:
Angezeigte Frequenz entspricht der
gewählten ZF-Frequenz.
6. Meßeinheit-Symbole:
Es leuchtet jeweils das entsprechende
Symbol der gewählten Meßfunktion (dBuV,
dBm, mA DC).
7. Ausgangssignal an Antenne bzw. LNB:
13 V, 18 V, 13 V+22 kHz, 18 V+22 kHz,
DiSEqC (A, B, C, D)
6. Grundeinstellungen
6.1. Anschluß des Satelliten-
meßgerätes an den LNB
Verstärker:
Eingang des Pegelmeßge-
rätes über ein 75 ΩKoaxial-
kabel mit dem LNB-Verstärker
verbinden (siehe Abb. 3-1).
Am Meßgerät geeignete
Abb. 3-1 Verbindung mit LNB Ausgangsspannung
(13 oder 18 V) wählen.
Anschluß des Satelliten-
pegelmeßgerätes an den
Satellitenempfänger:
Pegelmeßgerät über einen
Splitter mit DC-Block an den
Satellitenempfänger an-
schließen (Siehe Abb. 3-2).
Abb. 3-2 Anschluß mit Sat-Empfänger
Hinweis:
Ausgang des Pegelmeßgerätes nicht mit dem Eingang am DC-Block des
Splitters verbinden.
-9-
6. Units
Displays selected units
(dBuV and dBm for level, mADC for current)
7. Output signal to antenna signal
displays selected output signal to LNB
or antenna system. 13 V, 18 V, 13 V
with 22 kHz, 18 V with 22 kHz,
DiSEqC signal (A, B, C, D)
6. Basic Operation
6.1. Basic Operation
6.1.1.Connecting with LNB
a. Powered by SAT Level
Meter: Connect the LNB
and INPUT Connector of
this meter using a 75ohm
coaxial cable. (See figure
3-1). Set the output
voltage for proper operation.
(13V or 18V) Fig. 3-1 Connecting with LNB
b. Powered by Satellite
receiver: Use “Splitter with
DC-block” for connecting
this meter and Satellite
receiver. (See figure 3-2)
Note :
Do not apply output voltage Fig. 3-2 Powered by Satellite
from this meter by connecting Receiver
to “DC Blocked terminal”
of Splitter.
-26-
6.1.2. Setup for Multi-Site Viewing
Figure 3-3 is shown a set-up
example for two LNB (or antenna)
system. When connect this meter to
the outlet (or Output of switch Box),
connect through “DC Block” to cut
the OUTPUT Signal form this meter.
Refer to Section 6.1.1: “Connecting
with LNB” for connecting this meter
to the LNB (or Antenna system).
Fig. 3-3
Setup for Multi-Site viewing
6.1.3. Change of Frequency to measure
The frequency can be changed in initial
status of operation and after selecting Channel.
a. Select desired frequency to measure level by
using “Up”,“Down” key. (900MHz – 2,150GHz
with 250kHz step)
** The frequency change is speed up by
pressing “Up/Down” key for fast change
of frequency.
b. Move to other selecting function by using
“Shift” key or push “Store” key(two times) to store.
-27-
5.2. LCD-Anzeigen
1
7
2
6
1. Balkengrafik:
Zur Darstellung des Signalpegels. Eine kleine
Skalenmarkierung entspricht 1 dBuV. Die
Anzahl der erleuchteten Skalenmarkierungen
bleibt bei einem Eingangssignal zwischen 40
und 80 dBuV konstant.
2. Funktionsanzeigen:
Anzeigen für Spitzenwerthaltefunktion, Batterie-
zustand und akustischen Monitorbetrieb. Es
leuchtet die der jeweils gewählten Funktion
entsprechende Anzeige.
3. Kanalanzeige:
Anzeige des gegenwärtig gewählten Kanals.
4. Pegelanzeige:
Pegelanzeige in dBuV oder dBmV bzw.
Stromwert zum LNB in mA DC.
-8-
3
4 5
Taste CALL :
Zum Aufruf von gespeicherten Daten (Kanälen)
Taste LAMP :
Zum Ein- und Ausschalten der LCD-Hintergrundbeleuchtung.
Tasten UP/DOWN Up / Down:
Zum Einstellen und Ändern der mit der SHIFT-Taste gewählten
Meßparameter
- Frequenzeinstellung von 900 MHz - 2,150 GHz in Schritten von 250 kHz.
- Kanalwahl (Kanal 1...99).
- Wahl der Meßfunktion (Normal, Spitzenwerthaltefunktion, akustische
Überwachung der Signalstärke)
- Änderung des Ausgangssignals (13 V, 18 V, 13 V+22 kHz, 18 V+22 kHz,
DiSEqC).
- Änderung auf eine alternative Meßeinheit (dBuV, dBmV, mA DC).
4. LCD-Anzeige
Zur Anzeige des Messpegels und anderer Meßgrößen.
5. DC-Eingang
Zum Anschluß eines Ladegerätes zum Laden des internen Akkus.
Geeignete Ladegeräte: AC/DC-Adapter, 12 V/500 mA Ausgang oder
Zigarettenanzünder im Auto.
-7-
6.1.4. Setup Function of measurements
The measuring function (Normal, Peak Holder,
Sound monitoring) can be selected.
a. Move to “Function” selection group by using
“Shift” key. Function group will be blinking.
b. Select desired function by using “Up/Down” key.
- Sound: Acoustic signal strength monitoring
- Peak Holder: Displayed Measuring level is
changed when new measuring level is higher
than previous measured value.
- Normal: Displayed Measuring level from input terminal.
(Blank of Function display)
c. Move to other selecting function by using
“Shift” key or push “Store” key(two times) to store.
6.1.5. Setup Output for Antenna system
To set up outputs for antenna system
(LNB), check the required signal of LNB.
(13V, 18V, 13V+22kHz, 18V+22kHz)
a. Move to “Output” selection group by using “Shift” key.
Outputs group will be blinking.
b. Select desired output signal by using “Up”
"Down” key.
c. Move to other selecting function by using
“Shift” key or push “Store” key(two times) to store.
6.1.6. Setup DiSEqC output
The DiSEqC 1.0 output can be used for
selecting proper LNB in “multi-combined
antenna systems with DiSEqC switch” in
Europe.
** DiSEqC: Digital Satellite Equipment Control