INSTRUCTIONS FOR USE
Insect Light Traps (ILTs)
Confidence in
Fly Control
www.pestwest.com
Rev: Mar 2023
Facebook
Twitter
Find us on: LinkedIn

The Mantis 1x2IP is a professional grade ying insect
management system, which has been designed for
installation in designated hazardous environments of
wet and dust. This system is tested for compliance to the
highest standards applicable within this grade of product
– EN60529:1992 IP66. However, the zoning classication
for IP66 environments requires proper interpretation and
each installation must be judged on its merits.
ALWAYS TURN OFF POWER TO THE SYSTEM BEFORE
SERVICING. DO NOT ATTEMPT TO OPEN THE LID OF
THE SYSTEM. THERE ARE NO USER SERVICEABLE
PARTS INSIDE THIS SYSTEM. REMOVAL OF ANY
PART INSIDE THIS SYSTEM WILL VOID BOTH THE
IP66 RATING AND PESTWEST WARRANTY. THIS
SYSTEM MUST BE FACTORY SERVICED ONLY.
PRODUCT DESCRIPTION
PestWest Mantis systems are made using the highest
quality materials.The frame of the Mantis 1x2IP is
made of 304 brushed stainless steel. A 316 marine
grade stainless steel guard protects the ultraviolet
lamps against damage and also prevents operators from
accidental contact with the glue board. The Mantis 1x2IP
is IP66 rated to the EN 60529-1992 standard for dust and
water ingress protection.
UNPACKING YOUR SYSTEM
Each Mantis 1x2IP is carefully inspected and packed
before leaving our factory.Before discarding the outer
carton, examine for obvious evidence of transport
damage.
Remove the system, and before installation, pay
particular attention to the removal of all packing
materials.
OPERATION
Insect Light Trap (ILT) systems operate on the principle
that most ying insects are attracted to light, particularly
to the ultraviolet (UV) end of the light spectrum. Since
insects will y at night, systems should operate 24 hours
a day.
System ecacy can be aected by the intensity of other
light sources (daylight and overhead lighting). For good
results, mount the system where competition from other
light sources is minimal. For best results, install all your
systems using the PestWest UV-AMETER.
• In food areas, mount the system adjacent to, but
not directly over, exposed food or food preparation
surfaces (attract ies away from food preparation
areas). Always refer to the current local, State and
Federal Food Codes.
• Observe where ies tend to aggregate and install
your system adjacent to that area.
• Mount systems adjacent to y ingress points
(service/overhead doors, and windows).
• Do not position the system over lock-out, tag-out
areas.
• Mount the system above head-level and clear of any
trac, such as forklift trucks.
The system is manufactured with an 8-foot power cord
and operates from a 120V 60Hz electrical supply. The
power cord is hard-wired for electrical safety.
When installing in a wet or dust area, the power
cord MUST be terminated by a connector designed
specically for that environment. Furthermore, it is
the recommendation of PestWest that this system be
installed by a licensed electrician qualied for these
environments.
INSTALLATION
The system is designed to be wall mounted and a bracket
is supplied. Using the wall bracket as a template, mark o
thepositions on the mounting surface. Screws and plastic
plugs are provided to mount the bracket in place, making
sure that the mounting lip of the bracket is highest in
place. Hook the 1x2IP system securely onto the bracket.
Secure the power cord to the wall or other rm surface
prior to connecting to the power supply. Remove the
backing paper from the glue board to reveal the adhesive
surface.
PRECAUTIONS: All PestWest systems are fully
insulated, Class I appliances. Observe the following
precautions:
• Do not submerge the system in water.
• Do not install where dangerous concentrations of
ammable gases or dusts are likely to occur.
• Ensure the system is properly grounded.
• Be certain to have a secure working platform while
servicing the system.
• Do not allow the glue board to become over-lled
with dead insects.
• The Mantis 1x2IP, when permanently mounted,
may be used both indoors and outdoors (if under a
covered area and installed by a licensed electrician).
CLEANING AND MAINTENANCE
ALWAYSTURN OFF POWER TOTHE SYSTEM BEFORE
SERVICING.
To maintain the attractive appearance of the system
wipe down and clean as often as required. Use a cloth
dampened with water and detergent or a proprietary
cleaner. Do not use scouring pads or abrasives.
Change the glue board at regular intervals, as required by
insect captures, or at least every 8 weeks.
It is recommended to lubricate all moving parts such as
the catch-tray spring-loaded retainer on an annual basis,
particularly in harsh environments.
If Mantis 1x2IP systems are placed within a food or
pharmaceutical plant, a pharmaceutical-grade lubricant
may be required.
The UVA lamps in ying insect management systems
should be changed once per year. Lamps that are less
than one year old are most attractive to targeted ying
insects. UVA is highly attractive to photo-positive
insects and is emitted from our Quantum lead-
free, shatter-resistant lamps already installed in
this system. UVA light is invisible to the human eye.
Daily switching on and o of the lamps results in an even
faster loss of the eective UVA emission. Use the PestWest
UV-AMETER to measure lamp ecacy.
Adding PestWest Indian Meal moth pheromone
monitors to the glue board further enhances the capture
experience.
IT IS MOST EFFECTIVE TO LEAVE THE SYSTEM ON
CONTINUOUSLY AND TO CHANGE THE QUANTUM
LAMPS AT LEAST ONCE PER YEAR PREFERABLY
POSTWINTER ONSET OF INCREASED INSECT
ACTIVITY.
PestWest’s exclusive FEP shatter-resistant lamp coating
is the highest quality available. FEP is both UVA and
operating temperature tolerant while allowing maximum
UVA emission at critical wavelengths.
CHANGING THE GLUE BOARD
ALWAYSTURN OFF POWER TOTHE SYSTEM BEFORE
SERVICING. DUE TO INSECT CONTAMINATION THE GLUE
BOARD SHOULD BE CHANGEDWHEN FULL OR AT LEAST
EVERY EIGHT WEEKS.
Remove the catch tray by pulling out and holding the
spring-loaded silver knob on the side of the tray. Remove
the old glue board by pulling down and out of the system.
Remove the backing paper from the new board and slide
into position, sticky side facing the UV lamps, ensure
it clicks into place under the retainers at the top of the
system. Replace catch tray.
Note that given the environment that this system is
designed to go in to, may require more frequent glue
board changes than in a less dusty environment.
REPLACEMENT
PARTS
DESCRIPTION / PRODUCT CODE
LAMPS: 15W QUANTUM BL SHATTER-
RESISTANT 130-000171
GLUE BOARD: 135-000057 (PLASTIC)
STARTERS: SERIES STARTER - PhilipsS22 or
800-000292
Use only genuine PestWest replacement parts to ensure
high eciency. Use of non-approved parts will void the
warranty.

CHANGING THE LAMPS
ALWAYSTURN OFF POWER TOTHE SYSTEM BEFORE
SERVICING.
Remove the catch tray by pulling out and holding
the spring-loaded silver knob on the side of the tray.
Open the guard; this pivots downwards from its lower
edge.Unclip thetop of the guard from the body by
pushing it upwards which will allow it to be hinged
forward on the lower pivot points. This will permit access
to the lamps and starters. Grasp the lamp with one hand
and unscrew the white waterproof cap counterclockwise
with the other hand until it slides free from the lamp
holder. Repeat this operation with thewaterproof capat
the other end of the lamp.
Care should be taken when removing each waterproof
cap to ensure that its rear black rubber water-sealingring
does not become displaced and remains on the lamp
holder body. Should this occur, it must be removed
and retted into the annular ring on the back of the
waterproof cap before the cap is screwed back onto the
lamp holder.
With the waterproof caps removed the lamp may now
be removed from the system. Repeat the operation with
theother lamp.
PestWest’s Mantis 1x2IP system is manufactured with the
revolutionary reusable Reectobakt® sleeves, a PestWest
innovation introduced to improve the performance
of the system.The Reectobakt® sleeve is a screen
positioned between the source of the UV light and the
glue board, reducing the amount of UV striking the board,
(signicantly increasing the life of the adhesive).
Unclip the Reectobakt® sleeves from the used lamps
and install them onto the new lamps following the
instructions described under – INSTALLING THE
REFLECTOBAKT® SLEEVE.
Position the waterproof caps on the new lamps, with
Reectobakt® sleeves, ret into the lamp holders by
pushing the lamps into place. Ret each waterproof cap
in turn while holding the lamp down in position with one
hand to avoid it springing out of place while the caps are
being tightened. The caps should be fully screwed down
to ensure a watertight seal with the lamp.
Be sure the Reectobakt sleeves are correctly placed
(shielding the glue board from the lamps). Ensure a
Reectobakt sleeve is centered on each lamp.
INSTALLING THE REFLECTOBAKT®
SLEEVE
ALWAYSTURN OFF POWER TOTHE SYSTEM BEFORE
SERVICING.
Take the lamp and line up the two leading edges of the
Reectobakt® sleeve with the pairs of pins at either end
of the lamp - see Fig 1. Ensure that the sleeve is centered
on the lamp so that the small gap between the end of the
sleeve and the metal end of the lamp is the same at both
ends. Carefully push the sleeve so it is in contact along
the length of the lamp surface. It should grip and stay in
position. Re-t the lamp into the lamp holder; the sleeve
should be positioned at the back of the lamp, (between
the lamp and the glue board), keeping the light o the
glue board. At all times, handle the shield with care.The
edges may be sharp and the dimensions are critical to
proper t upon the lamp.
Method of assembling Reectobakt® showing alignment
in relation to pins:
Fig 1
STARTER REPLACEMENT
(replace annually)
ALWAYSTURN OFF POWER TOTHE SYSTEM BEFORE
SERVICING.
The starters should be replaced every time lamps are
changed.This operation ismost easilyaccomplished
when the upper lamp is removed.To gain access to the
starters the white waterproof caps located on thelower
surface of the frame tray need to be removed. If they have
previously been tightened using tools,the use ofa pair of
electricians’pliers will enable this task to be more easily
accomplished.
To access the caps, rst remove the catch tray and drop
the front guard down (follow the procedure described
under CHANGING THE LAMPS). Unscrew one cap by
turning it counterclockwise. Remove the starter from its
housing by turning it counterclockwise, then extracting
it downwards. Repeat the same operation with the other
starter. Install the new starters following the above
procedure in reverse order. Be certain the blacksealing
gasket ringlocated on the starter cap is properly in place
to ensure a watertight t.
Reectobakt® is the registered trademark of PestWest
Electronics Limited.
Manufacturer reserves the right to vary
model specications without notice.
NOTE:
The Mantis 1x2IP is a professional grade ying insect
management system which has been designed for
installation in designated hazardous damp or dust
environments and has been tested for compliance to
the highest standards applicable within for this grade
of product – EN60529:1992 IP66. However the zoning
classication for IP66 environments requires proper
interpretation and each installation must be judged on
its merits.
Do not install where dangerous concentrations of
ammable gases or dust are likely to occur. This system
is not intended for hazardous locations. Call PestWest for
systems designed for these areas.
PestWest is able to provide, upon request, copies of
independent safety test certicates applicable to the
model, to enable a suitability assessment to be made for
a particular installation and no claims other than those
therein identied on these certicates are expressed or
implied. It is the ultimate responsibility of the installer to
ensure that the Mantis 1x2IP is suitable for a particular
environment.
Warranty information must be received and on le
with PestWest USA LLC for proper coverage.
For additional specialty products contact PestWest USA
LLC at 941.358.1983 or click to: www.pestwest.com/
Specialty Range
Lamp contains mercury (Hg),
dispose or recycle in accordance
with applicable laws. In US, consult
www.lamprecycle.org or 1-800-
922-6693 for measures to be taken
in case of breakage; safe handling
procedures; and recycling and
disposal options.
Outside of US, please contact your
local authorities.
Scan the QR code to register your 3-year
warranty or visit
https://support.pestwest.com/pestwest-
warranty/
RESTRICTIONS APPLY.
•
3
Y
E
A
R
W
A
R
R
A
N
T
Y
•
3
Y
E
A
R
W
A
R
R
A
N
T
Y
3
WARNING:
Cancer and/or Reproductive Harm
www.P65Warnings.ca.gov
30/8/07 09:34 Page 2 of 2 Issue 2 March 2003 Chameleon 1x2IP
RENEWING STICKY BOARDS
ALWAYS SWITCH OFF THE MACHINE BEFORE SERVICING.
DUE TO INSECT CONTAMINATION THE STICKY BOARDS
SHOULD BE CHANGED WHEN FULL OR AT LEAST EVERY
EIGHT WEEKS.
Remove the catch tray by pulling out and holding the spring-
loaded silver knob on the side of the tray. Remove the old sticky
board(s) by pulling down and out of the machine. Remove the
backing paper from the new boards and slide into position in the
machine, sticky side facing the UV tubes, ensuring they click into
place under the sprung retainers at the top of the machine.
Replace catch tray.
REPLACEMENT PARTS
TUBE: QUANTUM BL SHATTERPROOF
F15T8BL350SH
GLUE BOARD: VABB427
STARTER: SERIES STARTER - PhilipsS2 or
Sylvania typeFS22.
Universal 240v starters are unsuitable
and may cause unreliable starting of the
unit.
Only use genuine PestWest replacement parts to ensure high
efficiency. Use of non-approved parts may void the
guarantee.
CHANGING THE TUBES Remove the catch tray by pulling out and
holding the spring-loaded silver knob on the side of the tray. Open
the guard; this pivots downwards from its lower edge.Unclip
thetop of the guard from the body by pushing it upwards which will
allow it to be hinged forward on the lower pivot points. This will
permit access to the tubes and starters.
Grasp the tube with one hand and unscrew the white waterproof
cap anticlockwise with the other hand until it slides free from the
lamp holder. Repeat this operation with thewaterproof capat the
other end of the tube.
Care should be taken when removing each waterproof cap to
ensure that its rear red rubber water-sealingring does not become
displaced and remains on the lamp holder body. Should this occur,
it must be removed and refitted into the annular ring on the back of
the waterproof cap before the cap is screwed back onto the lamp
holder.
With the waterproof caps removed the tube may now be removed
by withdrawing it away from the unit. Repeat the operation with
theother tube.
PestWest's Chameleon 1x2 IP unit is fitted with the revolutionary
new Reflectobakt
®
sleeves, a PestWest innovation introduced to
improve the performance of the units. The Reflectobakt
®
sleeve is a
screen positioned between the source of the UV light and the sticky
board, reducing the amount of UV striking the board, and
significantly increasing the life of the adhesive.
Unclip the Reflectobakt
®
sleeves from the used tubes and fit them
onto the new tubes following the instructions described under –
FITTING THE REFLECTOBAKT
®
SLEEVE.
Position the waterproof caps on the new tubes, fitted with
Reflectobakt
®
sleeve, refit into the lamp holders by pushing the
tubes into place.Refit each waterproof cap in turn whilst holding the
tube down in position with one hand to avoid it springing out of
place whilst the caps are being tightened. The caps should be fully
screwed down to ensure a watertight seal with the tube.
Check that the Reflectobakt
®
sleeves are correctly placed, shielding
the glue board from the light emitted by the tubes thus maintaining
its effectiveness. Ensure the Reflectobakt
®
is positioned at an equal
distance from each end of the tube.
FITTING THE REFLECTOBAKT® SLEEVE Take the tube and line
up the two leading edges of the Reflectobakt
®
sleeve with the pairs
of pins at either end of the tube - see Fig 1. Ensure that the sleeve
is fitted centrally to the tube so that the small gap between the end
of the sleeve and the metal end of the tube is the same at both
ends. Carefully push the sleeve so it is in contact along the length
of the tube surface. It should grip and stay in position. Re-fit the
tube into the unit; the sleeve should be positioned at the back of the
tube, keeping the light off the sticky board. At all times, handle the
shield with care, as the dimensions are critical in order that it fits the
tube properly.
Method of assembling Reflectobakt
®
showing alignment in
relation to pins:
Fig 1
STARTER REPLACEMENT (if necessary). Should be replaced
every time tubes are changed. This operation ismost
easilyaccomplished when the upper tube is removed.To gain
access to the starters the white waterproof caps located on
thelower surface of the chassis tray need to be removed. If they
have previously been tightened using toolsthe use ofa pair of
electricians’pliers will enable this task to be more easily
accomplished. To access the caps, first remove the catch tray and
drop the front guard down (follow the procedure described under
CHANGING THE TUBES). Unscrew one cap by turning it
anticlockwise. Remove the starter from its housing by turning it
anticlockwise, then extracting it downwards. Repeat the same
operation with the other starter. Fit the new starters following the
above procedure in reverse order. Take great care that the
blacksealing gasket ring located on the starter cap is properly in
place to ensure a watertight fitting.
Reflectobakt
®
is the registered trademark of PestWest Electronics
Limited.
Manufacturer reserves the right to vary model specifications without
notice.
lamp
glue board

Confidence in
Fly Control
PestWest USA LLC
7135 16th Street E, Suite 124
Sarasota, FL, 34243
Oce: 941.358.1983
Fax: 941.358.1916
Toll Free: 866.476.7378
Email: [email protected]
www.pestwest.com
PestWest Electronics Ltd operates a quality
management system certified to ISO 9001
WARNING:
Cancer and/or Reproductive Harm
www.P65Warnings.ca.gov
Facebook
Twitter
Find us on: LinkedIn
Rev: Mar 2023
Insect Light Traps (ILTs)
Other PestWest Pest Control manuals

PestWest
PestWest CHAMELEON EXG X User manual

PestWest
PestWest Nemesis QUATTRO User manual

PestWest
PestWest flyDetect User manual

PestWest
PestWest Mantis Range 1X2 User manual

PestWest
PestWest Naturale User manual

PestWest
PestWest Mantis QUALIS User manual

PestWest
PestWest Mantis Uplight User manual

PestWest
PestWest Chameleon Sirius X User manual

PestWest
PestWest Chameleon Sirius User manual
Popular Pest Control manuals by other brands

Eazyzap
Eazyzap FT990 instruction manual

Isotronic
Isotronic 2eye 92405 Instructions for use

Huazheng
Huazheng HZQ-1090 quick start guide

Silverline
Silverline gardenSystem A-Frequency Sound Power 80 quick start guide

MARGO SUPPLIES
MARGO SUPPLIES MARGO ELECTRA 1100 manual

Hot Shot
Hot Shot ACCUSHOT operating instructions