CHANGING THE LAMPS
ALWAYSTURN OFF POWER TOTHE SYSTEM BEFORE
SERVICING.
Remove the catch tray by pulling out and holding
the spring-loaded silver knob on the side of the tray.
Open the guard; this pivots downwards from its lower
edge.Unclip thetop of the guard from the body by
pushing it upwards which will allow it to be hinged
forward on the lower pivot points. This will permit access
to the lamps and starters. Grasp the lamp with one hand
and unscrew the white waterproof cap counterclockwise
with the other hand until it slides free from the lamp
holder. Repeat this operation with thewaterproof capat
the other end of the lamp.
Care should be taken when removing each waterproof
cap to ensure that its rear black rubber water-sealingring
does not become displaced and remains on the lamp
holder body. Should this occur, it must be removed
and retted into the annular ring on the back of the
waterproof cap before the cap is screwed back onto the
lamp holder.
With the waterproof caps removed the lamp may now
be removed from the system. Repeat the operation with
theother lamp.
PestWest’s Mantis 1x2IP system is manufactured with the
revolutionary reusable Reectobakt® sleeves, a PestWest
innovation introduced to improve the performance
of the system.The Reectobakt® sleeve is a screen
positioned between the source of the UV light and the
glue board, reducing the amount of UV striking the board,
(signicantly increasing the life of the adhesive).
Unclip the Reectobakt® sleeves from the used lamps
and install them onto the new lamps following the
instructions described under – INSTALLING THE
REFLECTOBAKT® SLEEVE.
Position the waterproof caps on the new lamps, with
Reectobakt® sleeves, ret into the lamp holders by
pushing the lamps into place. Ret each waterproof cap
in turn while holding the lamp down in position with one
hand to avoid it springing out of place while the caps are
being tightened. The caps should be fully screwed down
to ensure a watertight seal with the lamp.
Be sure the Reectobakt sleeves are correctly placed
(shielding the glue board from the lamps). Ensure a
Reectobakt sleeve is centered on each lamp.
INSTALLING THE REFLECTOBAKT®
SLEEVE
ALWAYSTURN OFF POWER TOTHE SYSTEM BEFORE
SERVICING.
Take the lamp and line up the two leading edges of the
Reectobakt® sleeve with the pairs of pins at either end
of the lamp - see Fig 1. Ensure that the sleeve is centered
on the lamp so that the small gap between the end of the
sleeve and the metal end of the lamp is the same at both
ends. Carefully push the sleeve so it is in contact along
the length of the lamp surface. It should grip and stay in
position. Re-t the lamp into the lamp holder; the sleeve
should be positioned at the back of the lamp, (between
the lamp and the glue board), keeping the light o the
glue board. At all times, handle the shield with care.The
edges may be sharp and the dimensions are critical to
proper t upon the lamp.
Method of assembling Reectobakt® showing alignment
in relation to pins:
Fig 1
STARTER REPLACEMENT
(replace annually)
ALWAYSTURN OFF POWER TOTHE SYSTEM BEFORE
SERVICING.
The starters should be replaced every time lamps are
changed.This operation ismost easilyaccomplished
when the upper lamp is removed.To gain access to the
starters the white waterproof caps located on thelower
surface of the frame tray need to be removed. If they have
previously been tightened using tools,the use ofa pair of
electricians’pliers will enable this task to be more easily
accomplished.
To access the caps, rst remove the catch tray and drop
the front guard down (follow the procedure described
under CHANGING THE LAMPS). Unscrew one cap by
turning it counterclockwise. Remove the starter from its
housing by turning it counterclockwise, then extracting
it downwards. Repeat the same operation with the other
starter. Install the new starters following the above
procedure in reverse order. Be certain the blacksealing
gasket ringlocated on the starter cap is properly in place
to ensure a watertight t.
Reectobakt® is the registered trademark of PestWest
Electronics Limited.
Manufacturer reserves the right to vary
model specications without notice.
NOTE:
The Mantis 1x2IP is a professional grade ying insect
management system which has been designed for
installation in designated hazardous damp or dust
environments and has been tested for compliance to
the highest standards applicable within for this grade
of product – EN60529:1992 IP66. However the zoning
classication for IP66 environments requires proper
interpretation and each installation must be judged on
its merits.
Do not install where dangerous concentrations of
ammable gases or dust are likely to occur. This system
is not intended for hazardous locations. Call PestWest for
systems designed for these areas.
PestWest is able to provide, upon request, copies of
independent safety test certicates applicable to the
model, to enable a suitability assessment to be made for
a particular installation and no claims other than those
therein identied on these certicates are expressed or
implied. It is the ultimate responsibility of the installer to
ensure that the Mantis 1x2IP is suitable for a particular
environment.
Warranty information must be received and on le
with PestWest USA LLC for proper coverage.
For additional specialty products contact PestWest USA
LLC at 941.358.1983 or click to: www.pestwest.com/
Specialty Range
Lamp contains mercury (Hg),
dispose or recycle in accordance
with applicable laws. In US, consult
www.lamprecycle.org or 1-800-
922-6693 for measures to be taken
in case of breakage; safe handling
procedures; and recycling and
disposal options.
Outside of US, please contact your
local authorities.
Scan the QR code to register your 3-year
warranty or visit
https://support.pestwest.com/pestwest-
warranty/
RESTRICTIONS APPLY.
•
3
Y
E
A
R
W
A
R
R
A
N
T
Y
•
3
Y
E
A
R
W
A
R
R
A
N
T
Y
3
WARNING:
Cancer and/or Reproductive Harm
www.P65Warnings.ca.gov
30/8/07 09:34 Page 2 of 2 Issue 2 March 2003 Chameleon 1x2IP
RENEWING STICKY BOARDS
ALWAYS SWITCH OFF THE MACHINE BEFORE SERVICING.
DUE TO INSECT CONTAMINATION THE STICKY BOARDS
SHOULD BE CHANGED WHEN FULL OR AT LEAST EVERY
EIGHT WEEKS.
Remove the catch tray by pulling out and holding the spring-
loaded silver knob on the side of the tray. Remove the old sticky
board(s) by pulling down and out of the machine. Remove the
backing paper from the new boards and slide into position in the
machine, sticky side facing the UV tubes, ensuring they click into
place under the sprung retainers at the top of the machine.
Replace catch tray.
REPLACEMENT PARTS
TUBE: QUANTUM BL SHATTERPROOF
F15T8BL350SH
GLUE BOARD: VABB427
STARTER: SERIES STARTER - PhilipsS2 or
Sylvania typeFS22.
Universal 240v starters are unsuitable
and may cause unreliable starting of the
unit.
Only use genuine PestWest replacement parts to ensure high
efficiency. Use of non-approved parts may void the
guarantee.
CHANGING THE TUBES Remove the catch tray by pulling out and
holding the spring-loaded silver knob on the side of the tray. Open
the guard; this pivots downwards from its lower edge.Unclip
thetop of the guard from the body by pushing it upwards which will
allow it to be hinged forward on the lower pivot points. This will
permit access to the tubes and starters.
Grasp the tube with one hand and unscrew the white waterproof
cap anticlockwise with the other hand until it slides free from the
lamp holder. Repeat this operation with thewaterproof capat the
other end of the tube.
Care should be taken when removing each waterproof cap to
ensure that its rear red rubber water-sealingring does not become
displaced and remains on the lamp holder body. Should this occur,
it must be removed and refitted into the annular ring on the back of
the waterproof cap before the cap is screwed back onto the lamp
holder.
With the waterproof caps removed the tube may now be removed
by withdrawing it away from the unit. Repeat the operation with
theother tube.
PestWest's Chameleon 1x2 IP unit is fitted with the revolutionary
new Reflectobakt
®
sleeves, a PestWest innovation introduced to
improve the performance of the units. The Reflectobakt
®
sleeve is a
screen positioned between the source of the UV light and the sticky
board, reducing the amount of UV striking the board, and
significantly increasing the life of the adhesive.
Unclip the Reflectobakt
®
sleeves from the used tubes and fit them
onto the new tubes following the instructions described under –
FITTING THE REFLECTOBAKT
®
SLEEVE.
Position the waterproof caps on the new tubes, fitted with
Reflectobakt
®
sleeve, refit into the lamp holders by pushing the
tubes into place.Refit each waterproof cap in turn whilst holding the
tube down in position with one hand to avoid it springing out of
place whilst the caps are being tightened. The caps should be fully
screwed down to ensure a watertight seal with the tube.
Check that the Reflectobakt
®
sleeves are correctly placed, shielding
the glue board from the light emitted by the tubes thus maintaining
its effectiveness. Ensure the Reflectobakt
®
is positioned at an equal
distance from each end of the tube.
FITTING THE REFLECTOBAKT® SLEEVE Take the tube and line
up the two leading edges of the Reflectobakt
®
sleeve with the pairs
of pins at either end of the tube - see Fig 1. Ensure that the sleeve
is fitted centrally to the tube so that the small gap between the end
of the sleeve and the metal end of the tube is the same at both
ends. Carefully push the sleeve so it is in contact along the length
of the tube surface. It should grip and stay in position. Re-fit the
tube into the unit; the sleeve should be positioned at the back of the
tube, keeping the light off the sticky board. At all times, handle the
shield with care, as the dimensions are critical in order that it fits the
tube properly.
Method of assembling Reflectobakt
®
showing alignment in
relation to pins:
Fig 1
STARTER REPLACEMENT (if necessary). Should be replaced
every time tubes are changed. This operation ismost
easilyaccomplished when the upper tube is removed.To gain
access to the starters the white waterproof caps located on
thelower surface of the chassis tray need to be removed. If they
have previously been tightened using toolsthe use ofa pair of
electricians’pliers will enable this task to be more easily
accomplished. To access the caps, first remove the catch tray and
drop the front guard down (follow the procedure described under
CHANGING THE TUBES). Unscrew one cap by turning it
anticlockwise. Remove the starter from its housing by turning it
anticlockwise, then extracting it downwards. Repeat the same
operation with the other starter. Fit the new starters following the
above procedure in reverse order. Take great care that the
blacksealing gasket ring located on the starter cap is properly in
place to ensure a watertight fitting.
Reflectobakt
®
is the registered trademark of PestWest Electronics
Limited.
Manufacturer reserves the right to vary model specifications without
notice.
lamp