6
Drill the marked o points to a depth of approximately 1.5”using a 5/16 drill bit. Place the plastic anchors into the wall
then screw the screws into the plastic anchors leaving the head of the screw approximately 0.4” from the wall. If the wall is
drywall or stud partition, repeat the above procedure with the lower two attachment points.
The system will hook over the screws because of the keyhole feature. Fully tighten the screws to secure the system to the
wall.You may need to adjust the screws slightly so they don’t interfere with inserting the glue board. Re-install the LED
Lamp. CAUTION: refer to the“CHANGINGTHE LED LAMPS”section to ensure the LED lamp is installed correctly. Re-install
glue board (opposite procedure to removal). Secure the power cord to the wall or other rm surface prior to connecting to
the power supply.
MAINTENANCE
Always switch the Mantis Qualis o for maintenance.To clean your Qualis, always use a cloth dampened with water and a
MILD non-abrasive detergent. Do not use scouring pads or abrasives.
The Mantis Qualis Quantum X LED lamps should be replaced at least once every 3 years. Record the system installation
date on the label.
The Quantum X LED lamp is made from glass and has a shatter-resistant coating (use in glass exclusion zones).This shatter-
resistant coating is the highest quality available. FEP shatter-resistant coating is both UVA and operating temperature
tolerant, while allowing high UVA emission.
CHANGINGTHE GLUE BOARD
To ensure optimum performance of the Mantis® Qualis, install only PestWest LED 21”glue boards.The specialty
LED glue board has been developed in combination with the PestWest Quantum X LED lamp. Using any other glue
board will have a negative impact on the performance.
Regular assessments of the glue board are recommended. Switch o the system before servicing.The glue board should
be changed when full or at least every 6-8 weeks. Need help with identication? Connect with the PestWest technical team,
get assistance at https://www.pestwest.com/us/ask-dr-stuart-mitchell/
Open the front cover by lifting outwards from the bottom.When the cover is opened approximately 45° it will stay open on
its own.To remove the glue board, twist the glue board retainer tabs at the bottom of the Qualis outwards. Pull the old glue
board downward.
The glue board has a perforation line about 1.2”from the edge that allows this small section to be folded at a 90° angle.This
folded section will help catch any debris falling from the upper part of the glue board. Before removing the backing paper,
fold this section, and then remove the backing paper from the glue board.
Figure 4 – Folding the glue board in place
Slide the glue board into position (glue-side facing the UVA LED lamps). Ensure
the glue board clicks into place under the spring retainers at the top of the
Qualis. Fold the board retainer tabs back into the original closed position (to
hold the folded section of the glue board in place) and close the front cover.
Switch the system back on.