Models:
Measuring ranges:
water: 5...60 ml/min – 60...150 l/min
air: 0,6...2,2 Nl/min – 200...650 Nl/min
(referenced to 1 bar abs, 20°C)
Materials: Brass or stainless steel versions
Technical Data:
Max. Pressure:
DS 2.1 DS 2.2 DS 2.3/4
Liquids: 200 bar (MS)
300 bar (VA)
300 bar (MS)
350 bar (VA)
300 bar (MS)
350 bar (VA)
Gases: 300 bar (MS)
350 bar (VA)
300 bar (MS)
350 bar (VA)
250 bar (MS)
300 bar (VA)
Pressure loss: DS02.1: 0,02–0,2 bar
DS02.2: 0,02–0,3 bar
DS02./4: 0,02–0,4 bar
Max. media-
temperature: 100 °C (optional 160 °C) for liquids
120 °C (optional 160 °C) for gases
Ex-devices acc. to. ATEX-marking
Operating temp.: 70 °C with analogue transmitter AZ06
Electr. Connection: DS 2.1 and DS 2.2:
angle plug acc. to EN 175301-803,
form C (DIN 43650)
DS 2.3 and DS 2.4
angle plug nach EN 155301-803,
form A (DIN 43650),
Ex-contact 3S and 3U with 2 m cable
optional: cable connection
round plug M12 x 1 acc. to EN 50044,
angle plug with LED or glow lamp
Accuracy: ± 10 % of full scale
(for vertical installation)
Materials:
Brass version:
Wetted parts:
Meas. tube: brass (outside nickel plated)
Spring: st. steel 1.4571
Gaskets*: NBR, optional: EPDM, FKM
Magnet: ferrite
all other wetted parts: brass
Stainless steel version 1.4571:
Wetted parts:
Gaskets*: FKM, optional EPDM, NBR
Magnet: ferrite
all other wetted parts: stainless steel1.4571
*only for reduced connection
Order Code:
Order Number: DS 2.
Miniature variable area flowmeter-
and switch
1. 1. 1. W13. 1. 1. .
Connection female thread:
1 = G 1/4 1N = 1/4“ NPT*
2 = G 1/2 2N = 1/2“ NPT*
3 = G 3/4* 3N = 3/4“ NPT*
4 = G 1 4N = 1“ NPT*
*) reduced
Material:
1 = brass
2 = stainless steel 1.4571
Scale:
1 = for water
2 = for air (at 1 bar abs., 20 °C)
Measuring ranges:
Water Air:
only DS 2.1:
W101 = 5–60 ml/min L1002 = 0,6–2,2 Nl/min
W102A = 40–130 ml/min L1006 = 1,7–6,0 Nl/min
W106 = 0,1–0,6 l/min L1008 = 2,5–8,0 Nl/min
W11 = 0,2–1,2 l/min L1012 = 3–12 Nl/min
W12 = 0,4–2 l/min L1022 = 3–22 Nl/min
W13 = 0,5–3 l/min L1024 = 7–24 Nl/min
W15 = 1,0–5 l/min L1034 = 12–34 Nl/min
L1056 = 16–56 Nl/min
L1080 = 20–80 Nl/min
only DS 2.2:
W202 = 0,02–0,2 l/min L2010 = 2,5–10 Nl/min
W206 = 0,2–0,6 l/min L2020 = 5,5–20 Nl/min
W21 = 0,4–1,8 l/min L2030 = 8–30 Nl/min
W23 = 0,8–3,2 l/min L2035 = 10–35 Nl/min
W27 = 2–7 l/min L2090 = 45–90 Nl/min
W213 = 3–13 l/min L2220 = 55–220 Nl/min
W220 = 4–20 l/min L2240 = 65–240 Nl/min
W230 = 8–30 l/min L2300 = 80–300 Nl/min
L2525 = 140–525 Nl/min
DS 2.3 or DS 2.4
W3030 = 10–30 l/min L30180 = 60–180 Nl/min
W3045 = 15–45 l/min L30300 = 100–300 Nl/min
W3060 = 20–60 l/min L30650 = 200–650 Nl/min
W3090 = 30–90 l/min
only DS 2.4
W4150 = 60–150 l/min
Addition S...= special scale
Number of contacts:
0 = without contact (only for devices with indication and/or AZ06)
1 = 1 contact
2 = 2 contacts
Contact function / Analogue output:
(contact or analogue transmitter available)
0 = without
1 = N/O
2 = SPDT
2X = SPDT for SPS application (for devices from 1/2")
3ST5 = Ex-N/O, T5 (100 °C), with 2 m cabel, not for DS02.1
3ST6 = Ex-N/O, T6 (80 °C), with 2 m cabel, not for DS02.1
3UT5 = Ex-SPDT, T5 (100 °C), with 2 m cabel, not for DS02.1
3UT6 = Ex-SPDT, T6 (80 °C), with 2 m cabel, not for DS02.1
3SM = Ex-N/O, only DS02.1 and DS02.2
3UM = Ex-SPDT, only DS02.1 and DS02.2
AZ06.1.I = analogue transmitter 4...20 mA
AZ06.1.V = analogue transmitter 0...10 V
Options:
0 = without
1 = please specify in plain text
AZ = with pointer indication (not for DS02.1)
HT = high temperature version 160 °C
M12 = round plug M12 x 1 acc. to EN 50044 (Tmax. 85 °C)
Kx = cable version 1 m, 2 m, 5 m or 10 m
PKP Prozessmesstechnik GmbH
Borsigstr. 24 • D-65205 Wiesbaden
S +49 (0) 6122-7055-0 • T +49 (0) 6122 7055-50
Flow