1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
(Failure to follow these instructions may lead to re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to re, electric shock, or product damage.)
5.
When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
(Failure to follow this may cause damage to property, re, electric shock and loss of life.)
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
Please follow the instruction below to ensure safe and correct use of explosion proof products.
1. Explosion proof products should be managed according to explosion-proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2.
The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Use cable glands that satisfy the product’s explosion proof grade and temperature grade.
4. Unused cable entries must be lled with material that meets the explosion proof grade and temperature rating.
5. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product are
fully understood.
6. Installation, maintenance and repair of the product must be performed by experts in the explosion proof eld, or persons who have
received relevant training.
7. For safety, the product should be installed and operated in environments that avoid high temperature and high pressure.
8. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
9. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
10. This product requires grounding.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s specication.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, re, and electric shock.
7. Static electricity may be generated by physical contact due to the surface characteristics of this product so please use a wet towel
or anti-static cleaner to remove the foreign substances on the product.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
Please scan the QR code
for more
detailed product information.
www.qlight.com
6040 5040 4540
66
Ex

2
Zone
denitions(Gas)
Zone 1
High risk gas/vapour(Gas)
Zone 2
Medium risk gas/vapour(Gas)
Group
denitions(Gas)
GROUP II A
Acetone, Petrol, Methanol, Propane, Toluene
GROUP II B
Ethylene, City gas
GROUP II C
Hydrogen, Acetylene, Carbon sulphide
Maximum surface
temperature of
electrical equipment
T1
450
°C
T2
300°C
T3
200°C
Zone
denitions(Dust)
T4
135
°C
T5
100
°C
Group
denitions(Dust)
T6
85
°C
Zone 21
High risk powder/dust(Dust)
Zone 22
Medium risk powder/dust(Dust)
Group
denitions(Dust)
GROUP II A
Ignitible bers/yings(more than 0.5mm)
GROUP II B
Non-conductive dusts
GROUP II C
Conductive dusts
Model number
QNE(Al/ STS)
QNES(Al/ STS)
Range of
operating voltage
DC 12V or 24V
AC 120V or 230V
Ex mark
IECEX - Ex db IIC T5/T6 Gb
ATEX - II2G Ex db IIC
T5/T6 Gb
KCs - Ex db IIC T5/T6
Ambient operating
temperature
QNE
–40°C ≤ Ta ≤ 60°C (T5)
–40°C ≤ Ta ≤ 50°C (T6)
QNES
–40°C ≤ Ta ≤ 60°C (T5)
–40°C ≤ Ta ≤ 45°C (T6)
Explosion proof
Zone
Zone1, Zone2
Material
ALDC12.1, STS316L
Protection rating
IP66
QNES
-
WS
-
110/230
-
R
-
SUS
[Model
number] [Sound] [Voltage] [Color] [Housing
material]
|
| | | |
• QNES
• WS
-Warning sounds
• WP
-Special warning
sounds
• WM-Melodies
• WA-Alarms
• WV
-Customizable
sounds
• 12/24
-DC12V-24V
• 110/230
-AC110V-230V
R-Red
A-Amber
G-Green
B-Blue
• (Blank) - Al
• SUS - STS
QNE
-
110/230
-
R
-
SUS
[Model
number] [Voltage] [Color] [Housing
material]
| | | |
• QNE
• 12/24
-DC12V-24V
• 110/230
-AC110V-230V
R-Red
A-Amber
G-Green
B-Blue
• (Blank) - Al
• SUS - STS
•
QNE
•
QNES
Ordering Specications
Product Specications
■
Explosion Proof Specications
■
General Product Specications
Model number Voltage
Power consumption
Current Certicates Weight Color
QNE
DC12-24V Max. 7W Max. 0.558A
2.05kg R-Red
A-Amber
G-Green
B-Blue
AC110-230V Max. 20W Max. 0.136A
QNE-SUS
DC12-24V Max. 7W Max. 0.558A
4.65kg
AC110-230V Max. 20W Max. 0.136A
Model number Voltage
Power
consumption
Current Sound pattern and volume
Certicates
Weight Color
QNES
DC12-24V Max. 23W Max. 1.872A
• WS-5 Warning sounds : Max.110dB
• WP-5 Special warning sounds : Max.110dB
• WM-5 Melodies : Max.105dB
• WA-5 Alarms : Max.105dB
• WV-5 Customizable voices : Max.103dB
3.15kg
R-Red
A-Amber
G-Green
B-Blue
AC110-230V Max. 43W Max. 0.301A
QNES-SUS
DC12-24V Max. 23W Max. 1.872A
7.60kg
AC110-230V Max. 43W Max. 0.301A

3
Dimensions
(Units : mm)
98
150.6
10
125 100
225
38.5
CABLE ENTRY NPT 1/2"
6565
130
98
10
72 100
172
CABLE ENTRY NPT 1/2"
146.6
38.5
65 66
131Ø130
Ø130
PCD155
360˚/3-Ø8 FITTING HOLES
PCD155
360˚/3-Ø8 FITTING HOLES
QNE/ QNE-SUS
QNES/ QNES-SUS

4
Sound Setting - Select using the switch inside
of the unit(QNES only).
•
Standard unit has 5 built-in sound
tones.
Select different built-in sounds using
the sound setting switch.
Sound Setting - Select using External
contact(LC)(QNES only).
• Customized wiring available to select the sound tone via external
contact or transistor wiring type (Model number : -LC)
•
External power line -
UL1015 AWG18(0.75sq) x 2C 400mm
• External signal line -
UL1007 AWG22(0.3sq) 400mm
QNES-DC/AC
Ch1
Ch2
Ch3
Ch4
Ch5
Ch1
Ch2
Ch3
Ch4
Ch5
EXTERNAL CONTACT
EXTERNAL TRASISTOR-NPN
Common
Common
Power
Power
Fuse
Fuse
• Disassemble the cover assembly set.
①
Loosen four M6 bolts.
•
For detailed wiring instructions, please refer to Terminal Box PCB image below. Please assemble the cover set in reverse order of disassembly.
※ Please be careful of signal line jams during reassembly of the cover set.
Terminal Block Instructions
5-Ch(White)
1-Ch(Red)
3-Ch(Green)
(+)
4-Ch(Blue)
COM(Black)
2-Ch(Amber)
(
-
)
①
Sound setting switch
Terminal Box PCB
)
Power
Volume Adjustment(QNES only)
• The volume output of this
product is adjustable.
•
Turn the volume dial clockwise
to increase the volume, and
turn counter clockwise to
decrease the volume.
• There will be no sound when
the dial is put at MIN.
Volume Dial
VOL.
MIN.MAX.
Category Sound pat-
tern Channel Sound Tone
volume
(Max.)
WS
5 Warning
sounds
Ch1 Fire.A-ANG
110dB
Ch2 Emergency WA-U
Ch3 Ambulance PI-PO
Ch4 Machinery Fault
Ch5 High Expansion
WP
5
Special
Warning
sounds
Ch1 Fire.A-ANG
110dB
Ch2 Abandon Alarm
Ch3 Machinery Fault
Ch4 High Expansion
Ch5 7 Short PI. / 1 Long
WM
5 Melodies
Ch1 Sweet Home
105dB
Ch2 For Elise
Ch3 Cuckoo's Waltz
Ch4 Piano Sonata
Ch5 Turkish March
WA
5 Alarms
Ch1 Beep Intermittent
105dB
Ch2 Door Chime
Ch3 Phone Ring
Ch4 PI.PI.PI Short
Ch5 Tripping Beat
WV
5
Customiz-
able sounds
Ch1
Available upon
request
(customized voice
type)
103dB
Ch2
Ch3
Ch4
Ch5
Red
Amber
Green
Blue
White
White
Black
Black
Red
Amber
Green
Blue
White
White
Black
Black
■ Sound Type by Group

5
3-Ø9 HOLES
PCD 155
①
Parts Denition/ Installation/ Light Function Selection
•
First, machine taps or holes on the mounting surface
①
.
•
The mounting hole of this product is 8mm in diameter.
•
When machining taps, fasten the bolt through the mounting hole of
the product.
•
When machining holes, insert the bolt through the hole of the
product, and tighten the nut from the opposite side of the mounting
surface.
■
Parts Denition/ Installation ■ Light Function Selection
Protection cage
: STS316L
Lens
(Tempered glass)
Housing(AI)
•• Please refer to the chart below to use light function
selection switch located inside the product.
• Default function is set at steady LED. Select the desired function
for your application during installation.
Light function
No. 1 2
Operation
0 0 0
Steady LED
1 0 1
Flashing LED
2 1 0
Strobe LED
3 1 1
Simulated revolving/
ashing LED
ON(1)
OFF(0)
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP66.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP66), it may cause malfunction or damage to the product.
• For further information, please visit our website (www.qlight.com).
Mounting Hole Specications/ Grounding Instructions
• Machine holes on the mounting surface
referring to the diagram below.
QNE/ QNES
■ Mounting Hole Specications ■ Grounding Instructions
M4 ground contact part
• Please use an M4 bolt at the location marked in the diagram above
to ground the product.
• When connecting the grounding cable, please use a ring terminal.
• Please use a ring terminal made of C5212 material as it has the
same electrical properties of the conductor.
• Please use a grounding cable with a diameter greater than 4mm.
Light function
selection switch

ISO
International Organization for
Standardization
IECEx
International Explosion
Qlight quality assurance systems have been
KS Q ISO 9001:2009 regulation.
RoHS2
Restriction of Hazardous
Substances Directive
Qlight c omplies with the Restriction of Hazardous
Substances Directive by limiting its use of hazardous
materials.
KR
Korean Register of Shipping
Qlight’s design and quality assurance system has
CCS
Qlight’s design and quality assurance system has
ATEX
The European Regulatory
Framework or Manufacture,
Installation and Use of Equip-
ment in Explosive Atmospheres
Qlight’s explosion proof products comply with ATEX
Directives 94/9/EC.
manufactured and manage according to
international standards.
NEPSI
National Supervision and Inspection
Center for Explosion Protection
and Safety of Instrumentation
Qlight’s design and manufacturing system
meets the People’s Republic of China National
explosion proof Standard.
(Chinese Standard-GB3836/GB12476)
KCs
Explosion Proof Device
Safety Certification System
The safety performance of machines and
Technical capability and production system have
standards.
TIIS
Japan Explosion-proof
TIIS is a Japanes explosion proof test and certification
system accordance with the Ministry of Health, Labour
and Welfare Notice and the explosion proof guidelines for
factory electrical equipment. Qlight's explosion proof
products hasve been tested and certified by TIIS.
UL Underwriters Laboratories
Qlight’s design and quality assurance system has
been certified from UL to ensure the stability
of consumption goods and to protect consumers.
ABS
American Bureau of Shipping
Qlight’s design and quality assurance system
Shipping.
CCC
CCCF
Security & Protection
Qlight’s has obtained CCC which guarantees safety,
protection against fraud, environment, etc.
Qlight has passed the rigorous examination process
of "Passing Fire Protection Products Centering" In order
to sell fire-fighting products such as fire alarm equipment
to Chinese market.
CE
European Commission
KC
Commission.
LR
Lloyd’s Register
RMRS
Russian Maritime
Register of Shipping
Qlight’s design and quality assurance system has
Qlight’s products are certified by KC for preventing
accident caused by fire.
Qlight’s design and quality assurance system has
Shipping.
ICAO
International Civil Aviation
Organization
Qlight guarantees our products satisfy the criteria
regulated by the International Civil Aviation
Organization(ICAO, FAA).
E-mark
Commission Directive
Regarding Vehicle Industry
KCC
Conformity Assessment of Broad-
casting Communication Equipment
Qlight has obtained EU mark for approved vehicles and
vehicle components sold into the EU(EEA : European
Economic Area)
environment that causes unwanted electromagnetic
waves from the device, communication failure due to
other devices or external radio waves, and malfunction
of the device.
Qlight has been certified to protect the electromagnetic
Technical Certication
•
Qlight products are designed to meet strict quality and technical standards. Thus, the Qlight brand is widely recognized for its high quality
and technical innovations from leading institutions around the world.

MEMO

Head Ofce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight Overseas Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team Ofce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739
China Factory/ Shanghai Sales Ofce | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805)
For your safety
Specication and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - QNE -2007A
Head Ofce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111
(Toll free. +82-80-328-1111) Fax. +82-55-328-4064
Qlight Overseas Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong)
Tel.
+82-51-620-4100 Fax. +82-51-243-9826
Qlight Public Relations & Marketing Team Ofce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong)
Tel.
+82-51-245-0017
This manual suits for next models
1
Table of contents
Other Qlight Work Light manuals

Qlight
Qlight QML60 User manual

Qlight
Qlight QLEX-SLM Series User manual

Qlight
Qlight QL-PL User manual

Qlight
Qlight QMFL-300-Ex-24 User manual

Qlight
Qlight STA25SLM User manual

Qlight
Qlight QWL20 User manual

Qlight
Qlight QWL40 User manual

Qlight
Qlight QMHL-150-D User manual

Qlight
Qlight QMFLN Series User manual

Qlight
Qlight QML User manual
Popular Work Light manuals by other brands

Hella
Hella 959037 Series Mounting instructions

Cembre
Cembre CBL04-WA Operation and maintenance manual

CREE LIGHTING
CREE LIGHTING KR Series Installation instructions ans

Milwaukee
Milwaukee 49-24-0155 Operator's manual

Leotek
Leotek Arieta AR13 installation guide

Renkforce
Renkforce Murcia 1398933 operating instructions