Qlight STA25SLM User manual

PB 1
STA25/ 35/ 45SLM
23 44
90dB
5030
Ordering Specications
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o-• the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s speci¿cation.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, ¿re, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. During wiring or maintenance, please completely turn o-• the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a ¿re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to ¿re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, ¿re, electric shock and loss of life.)
STA25SLM
-3-220 -RAG
[Model
number] [Layer] [Voltage] [Color]
| | | |
• STA25SLM
• STA35SLM
•
Layer
1-1
•
Layer
2-2
•
Layer
3-3
•
Layer
4-4
•
Layer
5-5
• 12-DC12V
• 24-DC24V
• 110-AC110V
• 220-AC220V
R-Red
A-Amber
G-Green
B-Blue
W-White
Slim LED Tower Lights
STA45SLMP
-3-24 -RAG -QZ18
[Model number] [Layer] [Voltage] [Color]
[Mounting option]
| | | | |
• STA45SLM
• STA45SLM-BZ
• STA45SLMP
• STA45SLMP-BZ
•
Layer
1-1
•
Layer
2-2
•
Layer
3-3
•
Layer
4-4
•
Layer
5-5
• 12-DC12V
• 24-DC24V
R-Red
A-Amber
G-Green
B-Blue
W-White
• (Blank)
- Standard type
• Mounting type
-LB18 -LW18
-QZ18 -SZ18
-QL18 -SL18
• STA25SLM/ STA35SLM • STA45SLM(P)
Please scan the QR code
for more
detailed product information.
www.qlight.com

2 3
• Protection rating : IP44
• Ambient operating temperature : -30°C to +50°C
※CE compliant : DC24V
※UL listed : DC24V
※CE compliant : DC24V
※UL listed : DC24V
※CE compliant : DC24V
※UL listed : DC24V
※CE compliant : DC24V
Product Specications
• STA25SLM • STA35SLM
Model
number
Layer Voltage
Current
Certi¿cate
Weight
Color
STA25SLM
steady type
1
AC/DC12V
AC/DC24V
AC110V
AC220V
0.080A
0.040A
0.020A
0.020A
0.19kg
R-Red
2
AC/DC12V
AC/DC24V
AC110V
AC220V
0.160A
0.080A
0.040A
0.040A
0.21kg
R-Red
G-Green
3
AC/DC12V
AC/DC24V
AC110V
AC220V
0.240A
0.120A
0.060A
0.060A
0.23kg
R-Red
A-Amber
G-Green
4
AC/DC12V
AC/DC24V
AC110V
AC220V
0.320A
0.160A
0.080A
0.080A
0.24kg
R-Red
A-Amber
G-Green
B-Blue
5
AC/DC12V
AC/DC24V
AC110V
AC220V
0.400A
0.200A
0.100A
0.100A
0.26kg
R-Red
A-Amber
G-Green
B-Blue
W-White
Model
number
Layer Voltage
Current
Certi¿cate
Weight
Color
STA35SLM
steady type
1
AC/DC12V
AC/DC24V
AC110V
AC220V
0.100A
0.050A
0.020A
0.020A
0.38kg
R-Red
2
AC/DC12V
AC/DC24V
AC110V
AC220V
0.200A
0.100A
0.040A
0.040A
0.40kg
R-Red
G-Green
3
AC/DC12V
AC/DC24V
AC110V
AC220V
0.300A
0.150A
0.060A
0.060A
0.42kg
R-Red
A-Amber
G-Green
4
AC/DC12V
AC/DC24V
AC110V
AC220V
0.400A
0.200A
0.080A
0.080A
0.45kg
R-Red
A-Amber
G-Green
B-Blue
5
AC/DC12V
AC/DC24V
AC110V
AC220V
0.500A
0.250A
0.100A
0.100A
0.48kg
R-Red
A-Amber
G-Green
B-Blue
W-White
• STA45SLM • STA45SLMP
Model
number
Layer Voltage
Current
Certi¿cate
Weight
Color
STA45SLM
steady type
STA45SLM
-BZ
Steady
/w built-in
buzzer
1
AC/DC12V
AC/DC24V
0.100A
0.050A
0.50kg
R-Red
2
AC/DC12V
AC/DC24V
0.200A
0.100A
0.54kg
R-Red
G-Green
3
AC/DC12V
AC/DC24V
0.300A
0.150A
0.58kg
R-Red
A-Amber
G-Green
4
AC/DC12V
AC/DC24V
0.400A
0.200A
0.63kg
R-Red
A-Amber
G-Green
B-Blue
5
AC/DC12V
AC/DC24V
0.500A
0.250A
0.68kg
R-Red
A-Amber
G-Green
B-Blue
W-White
Model
number
Layer Voltage
Current
Certi¿cate
Weight
Color
STA45SLMP
steady type
STA45SLMP
-BZ
Steady
/w built-in
buzzer
1
AC/DC12V
AC/DC24V
0.100A
0.050A
0.56kg
R-Red
2
AC/DC12V
AC/DC24V
0.200A
0.100A
0.60kg
R-Red
G-Green
3
AC/DC12V
AC/DC24V
0.300A
0.150A
0.64kg
R-Red
A-Amber
G-Green
4
AC/DC12V
AC/DC24V
0.400A
0.200A
0.69kg
R-Red
A-Amber
G-Green
B-Blue
5
AC/DC12V
AC/DC24V
0.500A
0.250A
0.74kg
R-Red
A-Amber
G-Green
B-Blue
W-White
• Protection rating : IP44(standard type), IP23(buzzer type).
• Ambient operating temperature: : -30°C to +50°C

2 3
Ø25 Ø45
Ø35 Ø45
Ø18
LAYER
1
2
3
4
5
L
368
398
428
458
488
LAYER
1
2
3
4
5
L
198
243
288
333
378
LAYER
1
2
3
4
5
L
205
250
295
340
375
LAYER
1
2
3
4
5
L
398
443
488
533
568
1030328
L
M23x 2.5 THREAD
5
1045
150
L31
M20 x 2.5 THREAD
15150200
L
M18x 1.5 THREAD
15150
31 L
M20 x 2.5 THREAD
45
45
STA25SLM
STA35SLM
STA45SLM STA45SLM-BZ
STA45SLMP STA45SLMP-BZ
Dimensions
(Units : mm)

4 5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
Wiring using external contact
DC
steady type
Wiring Instructions
• STA25SLM, STA35SLM, STA45SLM(P) can be wired by using both external contact and transistor.
• In case of wiring by transistor, please make sure if it is NPN type or PNP type. Please carefully follow wiring instruction below.
Transistor(I/O unit)
DC
steady type
(NPN
Transistor)
DC
steady type
(PNP
Transistor)
Red
Amber
Green
Blue
White
Black
Red
Amber
Green
Blue
White
Black
Red
Amber
Green
Blue
White
Black
Red
Amber
Green
Blue
White
Brown
Black
Red
Amber
Green
Blue
White
Brown
Black
Red
Amber
Green
Blue
White
Brown
Black
EXTERNAL CONTACT EXTERNAL CONTACT
Power
Power
Power
Power
Power
Power
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
EXTERNAL TRANSISTOR-NPN
EXTERNAL TRANSISTOR-PNP
EXTERNAL TRANSISTOR-NPN
EXTERNAL TRANSISTOR-PNP
Steady
Steady
Steady
Steady
Steady
Steady
Layer1
Layer2
Layer3
Layer4
Layer5
Layer1
Layer2
Layer3
Layer4
Layer5
Layer1
Layer2
Layer3
Layer4
Layer5
Layer1
Layer2
Layer3
Layer4
Layer5
Buzzer
Layer1
Layer2
Layer3
Layer4
Layer5
Buzzer
Layer1
Layer2
Layer3
Layer4
Layer5
Buzzer
• External power line/ External signal line - UL1007 AWG22(0.3sq) 400mm
STA25SLM-DC
STA35SLM-DC
STA25SLM-DC
STA35SLM-DC
STA25SLM-DC
STA35SLM-DC
STA45SLM/ST45SLMP-DC
STA45SLM/ST45SLMP-DC
STA45SLM/ST45SLMP-DC

4 5
STA25SLM/ STA35SLM STA45SLM
Dimensions
STAWB25 STAWB45
STA35SLM/ STA45SLM
STA25SLM
Ø24 CABLE ENTR
YØ22 CABLE ENTRY
Ø24 CABLE ENTRYØ
22 CABLE ENTRY
Ø12 CABLE ENTRY
84
50
25
50
86
44
PCD40~50
4-Ø4.5 HOLES
360°/6-Ø5 HOLES
Ø12
Ø12 CABLE ENTRY
4-Ø4.5 HOLES
360°/6-Ø5 HOLES
Ø12
60
35
20
04
66
36
PCD30~40
13
50
84
50
20
44
86
12
35
60
40
12
36
66
10
6
PCD30~40
4-Ø5 HOLES
360°/3-
Ø5 HOLES
4-Ø5 HOLES
360°/3-
Ø5 HOLES
PCD40~50
Ø12 CABLE ENTRY
84
50
25
50
86
44
PCD40~50
4-Ø4.5 HOLES
360°/6-Ø5 HOLES
Ø12
Ø12 CABLE ENTRY
4-Ø4.5 HOLES
360°/6-Ø5 HOLES
Ø12
60
35
20
04
66
36
PCD30~40
13
50
84
50
20
44
86
12
35
60
40
12
36
66
10
6
PCD30~40
4-Ø5 HOLES
360°/3-
Ø5 HOLES
4-Ø5 HOLES
360°/3-
Ø5 HOLES
PCD40~50
Parts Denition/ Installation Mounting Hole Specications
Installation Environment and Protection Rating
• This product is designed for indoor use with protection rating of IP44(standard type) or IP23(buzzer type).
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated, it may cause malfunction or damage to the product.
• For further information, please visit our website (www.qlight.com).
Cover(ABS)
Housing(Al)
Spring washer
Nut
Washer
Bolt(M5)
Bracket(Steel)
Lens(AS)
•
Machine holes on the mounting surface referring to
the diagram below.
Mounting Accessories (Sold Separately)
• Please refer to the dimensions below for installation of mounting brackets
■ STA25SLM/ STA35SLM/ STA45SLM-Direct Mounting Type Model

6
Mounting Accessories (Sold Separately)
• Please refer to the dimensions below for installation of mounting brackets
■ STA45SLMP - Pole Mounting Type Model
Dimensions
STA45SLMP
18mm SCREW & NUT LB18
LW18 SZ18
QZ18 SL18
QL18
Ø18
Ø18
32
34 24
Ø70
51
M18x1.5
THREAD
75
52
69
Ø18
Ø18
66
52
38
34
46
50
58
Ø28
1/2" PF
4-Ø5 HOLES
12x22
CABLE ENTRY
Ø70
50
Ø18
4-Ø5 HOLES
PCD 56
4-Ø5.5 HOLES
2-Ø8.5 HOLES
PCD 54~56
Ø18
Ø18
Ø70
51.5 67
4-Ø5.5 HOLES
Ø18 CABLE ENTRY
PCD 54~56
Ø90
4-Ø6 HOLES
Ø11 CABLE ENTRY
66
45.5
PCD 73

Product installation direction
■ Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product.
ㆍ ELECTRONIC SOUNDER/SIGNAL HORN
Sounder part shall not be facing the sky.
Sounder part shall not be facing the sky.
ㆍBEACON/SIGNALING LIGHT
Power cord inlet part shall not be facing the sky.
Power cord inlet part shall not be facing the sky.
ㆍSIGNAL TOWER LIGHTS
ㆍHEAVY-DUTY & EXPLOSION PROOF SIGNALINGS
※For products with a protection rating of less than IPX4, please install it vertically.
※For products with a protection rating of less than IPX4, please install it vertically.

Head O-ce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight OverSEAs Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team O-ce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739
China Factory/ Shanghai Sales O-ce | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China
Tel +86
-
513
-
8384
-
9999 Fax +86
-
513
-
8384
-
9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea ( Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea ( Postal Code : 50805)
For your safety
Speci¿cation and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - STA45SLM - 2211A
This manual suits for next models
2
Table of contents
Other Qlight Work Light manuals

Qlight
Qlight QML series User manual

Qlight
Qlight QML60 User manual

Qlight
Qlight QWL40 User manual

Qlight
Qlight QWL20 User manual

Qlight
Qlight QMFLN Series User manual

Qlight
Qlight QMFL-300-Ex-24 User manual

Qlight
Qlight QMHL-150-D User manual

Qlight
Qlight QML User manual

Qlight
Qlight EPLUS Series User manual

Qlight
Qlight QL-PL User manual