Qlightec QA85LSE User manual

1
LED Warning Lights for Heavy Equipment
QA85LSE
65
5030
• Protection rating : IP65
• Ambient operating temperature : -30°C to +50°C
• Operation mode can be selected upon order
Model
number Voltage
Operation
mode
Current Flashing rate
Weight Color
QA85LSE
DC12V-24V
steady
Max. 0.150A
-
0.16kg
R-Red
A-Amber
G-Green
B-Blue
ashing
Max. 0.290A 60-80/min
Strobe 1
Max. 0.180A 60-80/min
Strobe 2
Max. 0.180A 40-60/min
QA85LSE - 12/24 - A
[Model number] [Voltage] [Color]
| | |
• QA85LSE
• 12 / 24
- DC12V - 24V R-Red
A-Amber
G-Green
B-Blue
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failuretofollowtheinstructionsbelowmaycausealossoflifeorseriousphysicalinjury.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o- the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s speci¿cation.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, ¿re, and electric shock.
Precautions for Correct Use
Failuretofollowtheproperinstructionsmaycausedamagetoproperty,theproduct,ormalfunctionofthe
productthatwouldvoidthewarranty.
1. During wiring or maintenance, please completely turn o- the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a ¿re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to ¿re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to ¿re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, ¿re, electric shock and loss of life.)
Ordering Specications Product Specications
Please scan the QR code for more
detailed product information.
www.qlight.com

2
• External power line -
20AWG (0.5sq) × 2C 400mm
•
DC type : Black output line is negative(-)
QA85LSE
Ø5 CABLE ENTRY
PCD 117~120
Ø85.7
Ø132
90
20
360°/ 3-Ø5.2 HOLES
DC
Red
Black
Fuse Power
DC12-24V
• Machine holes on the mounting surface referring to the
diagram below.
360°/3-Ø5.2 HOLES
QA85LSE
PCD 117~120
Lens(PC)
LED
Bolt
Housing(ABS)
Flange nut
• First, machine taps or holes on the mounting surface.
• The mounting hole of this product is 5.2mm in diameter.
• When machining holes, insert the bolt through the hole of
the product, and tighten the nut from the opposite side of the
mounting surface.
■ Parts Denition ■Installation
■ Mounting Hole Specications
Wiring Instructions
Parts Denition/ Installation/ Mounting Hole Specications
Dimensions
(Units : mm)
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP65.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP65), it may cause malfunction or damage to the product.
• In case of outdoor applications, installation in the upright position is suggested to minimize the e-ect of rain on the product.
• For further information, please visit our website (www.qlight.com).

Product installation direction
■ Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product.
ㆍ ELECTRONIC SOUNDER/SIGNAL HORN
Sounder part shall not be facing the sky.
Sounder part shall not be facing the sky.
ㆍBEACON/SIGNALING LIGHT
Power cord inlet part shall not be facing the sky.
Power cord inlet part shall not be facing the sky.
ㆍSIGNAL TOWER LIGHTS
ㆍHEAVY-DUTY & EXPLOSION PROOF SIGNALINGS
※ For products with a protection rating of less than IPX4, please install it vertically.
※ For products with a protection rating of less than IPX4, please install it vertically.

Head O-ce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight OverSEAs Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team O-ce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739
China Factory/ Shanghai Sales O-ce | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China
Tel +86
-
513
-
8384
-
9999 Fax +86
-
513
-
8384
-
9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea ( Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea ( Postal Code : 50805)
For your safety
Speci¿cation and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - QA85LSE - 2303A
Other Qlightec Security System manuals
Popular Security System manuals by other brands

Lucent Technologies
Lucent Technologies PacketStar user guide

König
König SEC-ALARM210 manual

TELUS
TELUS LivingWell Companion Go user manual

Silent Alert
Silent Alert UM3A-2212-EU-MIC quick start guide

Bulldog Security
Bulldog Security 742 Installation and owner's guide

Lorex
Lorex U222AA-Z Quick connection guide