Qlightec S125DML User manual

1
Signal/ Waring Lights with Built-in Sounder
S125DML
S125DML
-
WS
-
220
-
R
[Model number] [Sound] [Voltage] [Color]
| |
| |
• S125DML • WS-Warning
• WM-Melody
• WA-Alarm
• WV-Customizable sound
• 12/24-DC12/24V
• 110/220-AC110/220V
R-Red
A-Amber
G-Green
B-Blue
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn o the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s specication.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, re, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, and or malfunction of the
product that would void the warranty.
1. During wiring or maintenance, please completely turn o the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to re, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, re, electric shock and loss of life.)
Ordering Specications
5030
54
105
HORN

2
S125DML
S125DML-DC/AC
• External power line - UL1015 AWG18(0.75sq) x 2C 400mm
• External signal line - UL1007 AWG22(0.3sq) 400mm
■ Wiring Instructions ■ Sound Type by Group
Group
Sound Channel
Type of sound
Max.
WS
5 Warning
Sounds
Ch1
Fire.A-ANG
105dB
Ch2
Emergency WA-U
Ch3
Ambulance PI-PO
Ch4
Machinery Fault
Ch5
High Expansion
WM 5 Melodies
Ch1
Sweet Home
105dB
Ch2
For Elise
Ch3
Cuckoo's Waltz
Ch4
Piano Sonata
Ch5
Turkish March
WA 5 Alarms
Ch1
Beep Intermittent
103dB
Ch2
Door Chime
Ch3
Phone Ring
Ch4
PI.PI.PI Short
Ch5
Tripping Beat
WV 5 Customizable
sounds
Ch1
Available upon
request
(customized
voice type)
95dB
Ch2
Ch3
Ch4
Ch5
Ø110
Ø119
Ø10
CABLE ENTRY
15
112 108
222
PCD70
360°/3-M5 BOLT
Model number Voltage Current Sound pattern and volume Certicates Weight Color
S125DML
DC12-24V Max.0.400A
• WS-5 Warning sounds : 105dB
• WM-5 Melodies : 105dB
• WA-5 Alarms : 103dB
• WV-5 Customizable sounds : 95dB
-
0.88Kg
R-Red
A-Amber
G-Green
B-Blue
AC110-220V Max.0.140A 0.93Kg
• Protection rating : IP54
• Ambient operating temperature : -30°C to +50°C
Product Specications
Dimensions
(Units : mm)
Wiring Instructions/ Sound Type by Group
Red
Red
Ch 1
Ch 1
EXTERNAL CONTACT
Ch 2
Ch 2
Ch 3
Ch 3
Ch 4
Ch 4
Ch 5
Ch 5
Amber
Amber
Green
Green
Blue
Blue
Fuse
Fuse
White
White
White
White
Black
Black
Black
Black
Power
Power
EXTERNAL TRANSISTOR-NPN
Common
Common

3
S125DML
Lens(AS)
LED unit
Light function
No. 1 2
000Steady LED
101Flashing LED
210Strobe LED
311Simulated revolving/
ashing LED
ON(1)
OFF(0)
Parts Denition/ Installation/ Light Function Selection/ Volume Adjustment
•• Please refer to the chart below to use light function selection
switch located inside the product.
• Default function is set at steady LED. Select the desired function
for your application during installation.
■ Parts Denition/ Installation ■ Light Function Selection
Flange nut
Resonance chamber
(ABS)
Housing(ABS)
Rubber spacer
• First, remove the ange nuts from bolts and place the
product through the mounting surface holes.
•
Fasten the ange nuts on the opposite side of the mounting
surface until the product is tightened securely.
• Machine holes on the mounting surface
referring to the diagram below.
Mounting Hole Specications
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP54.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating indica-
ted(IP54), it may cause malfunction or damage to the product.
• In case of outdoor applications, install the product in the upright or horizontal position. Do not install the product upside-down or in
positions where water can potentially penetrate into the product and impact its operation.
• For further information, please visit our website (www.qlight.com).
3-
Ø6
HOLES
Min. Ø5 CABLE ENTRY
PCD70
■Volume Adjustment
• The volume output of this
product is adjustable.
•
Turn the volume dial clockwise
to increase the volume, and
turn counter clockwise to
decrease the volume.
• There will be no sound when
the dial is put at MIN.
Volume Dial
VOL.
MIN.MAX.

Head Oce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight OverSEAs Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team Oce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739
China Factory/ Shanghai Sales Oce | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China
Tel +86
-
513
-
8384
-
9999 Fax +86
-
513
-
8384
-
9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805)
For your safety
Specication and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - S125DML - 2106A
Other Qlightec Security System manuals