Reliable F1 56 User manual

Model F1 56 Sprinkler
Standard Pendent
Model F1 56 Recessed Sprinkler Types
Recessed Pendent/F1 and F2
Recessed Pendent/FP
Corrosion Resistant (UL, ULC) Polyester Coated
Model F1 56
Model F1 56 Recessed
Standard Response
Sprinklers
The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523
Bulletin 013 Rev.B
Recessed Pendent/FP
Bulletin 013 Rev.B
Listings & Approvals
1. Listed by Underwriters Laboratories, Inc. (UL)
2. Listed by Underwriters’ Laboratories of Canada (ULC)
3. Certified by FM Approvals
UL Listing Category
Sprinklers, Automatic & Open
UL Guide Number
VNIV
Product Description
The F1 56 Glass Bulb Sprinkler combines the durability of
a standard sprinkler with the attractive low profile of a
decorative sprinkler. Whether installed on exposed piping
or in an office ceiling, it is functional and attractive.
Beautifully versatile is the description for the Reliable
Model F1 56 Recessed glass bulb sprinkler. Recessing the
F1 56 enhances its already low profile decorative
appearance, and facilitates a rapid and perfect installation.
Model F1 56 Recessed escutcheon is highly adjustable.
The two piece construction makes field installation a very
easy and rapid task. This also allows ceiling panels to later
be removed without shutting down the fire protection
system, thus facilitating maintenance of above ceiling
services.
The F1 56 Automatic Sprinkler utilizes a frangible glass
bulb. The glass bulb consists of an accurately controlled
amount of special fluid hermetically sealed inside of a
precisely manufactured glass capsule. This glass bulb is
specially constructed to provide fast thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid phase and in the vapor phase. The vapor
phase can be seen as a small bubble. As heat is applied,
the liquid expands forcing the bubble smaller and smaller
as the liquid pressure increases. Continued heating forces
the liquid to push out against the bulb, causing the glass to
shatter, opening the waterway and allowing the deflector to
distribute the discharging water.
The F1 56 Sprinkler temperature rating is identified by the
color of the glass bulb capsule as well as frame color where
applicable.
Recessed Pendent/F1
Pendent
Model F1 56 Pendent Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Model F1 56 Recessed Pendent Sprinkler
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Model F1 56/F1 or F2
2.
Nominal
Orifice
Thread
Size
K Factor Sprinkler
Height
Approval
Organizations
Sprinkler Identification
Number (SIN)
US Metric
12" (15mm) 12" NPT (R1/2) 5.6 80 2.25" (57mm) 1,2,3(2) RA1314
(2) FM Approval
- Light Hazard - No Limitations
- Ordinary Hazard - Groups1&2,WetSystems only.
Pendent
Sprinkler Type K Factor Sprinkler
Height
Approval
Organizations
Sprinkler Identification
Number (SIN)
US Metric
12" (15mm) Standard Orifice with 12" NPT (R1/2) Thread 5.6 80 2.25" (57mm) 1,2,3 RA1314
Model F1 56/FP
3.
Finish
(1) UL, ULC and FM approved. UL and ULC listed corrosion
resistant sprinkler.
(2) FP Push on-thread off escutcheon.
Sprinkler Escutcheon
White Polyester Coated(1)(2) White Painted
Model F1 56 & F1 56 Recessed Sprinklers
Application
Model F1 56 and F1 56 Recessed sprinklers are used in
fixed fire protection systems: Wet, Dry, Deluge or Preaction.
Care must exercised that the orifice size, temperature rating,
deflector style and sprinkler type are in accordance with the
latest published standards of the National Fire Protection
Association or the approving Authority Having Jurisdiction
Installation.
Installation
Model F1 56 sprinklers are standard response sprinklers
intended for installation as specified in NFPA 13. They must
also be installed with the Model D Sprinkler Wrench
specifically designed by Reliable for use with these
sprinklers.
The Model F1 56 Recessed Sprinklers are to be installed
with a maximum recess of ¾ inch (19mm). The Model F1 56
Escutcheon illustrated is the only recessed escutcheon to be
used with the Model F1 56 Pendent Sprinklers. The use of
any other recessed escutcheon will void all approvals and
negate all warranties. When installing Model F1 56
Recessed Pendent use the Model GFR2 Sprinkler Wrench.
Any other type of wrench may damage these sprinklers.
Note: A leak tight ½" NPT (R1/2) sprinkler joint can be
obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not
tighten sprinklers over maximum recommended torque. It
may cause leakage or impairment of the sprinklers.
Glass bulb sprinklers have orange covers to protect the
bulb during the installation process. REMOVE THIS
PROTECTION ONLY AFTER THE SYSTEM HAS BEEN
HYDROSTATICALLY TESTED AND, WHEN APPLICABLE,
THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO
wrenches are designed to install sprinklers when covers are
in place.
Temperature Ratings
Classification
Sprinkler
Temperature Max. Ambient
Temp.
Bulb
Color
°C °F
Ordinary
Ordinary
Intermediate
Intermediate
High (1)
Extra High (1)
57
68
79
93
141
182
135
155
175
200
286
360
100°F(38°C)
100°F(38°C)
150°F(66°C)
150°F(66°C)
225°F (107°C)
300°F (149°C)
Orange
Red
Yellow
Green
Blue
Mauve
(1) Not available for F1 Recessed.
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating:
- Specify Bulb Size when ordering
- Model F1 EC HSW Sprinkler
6. Sprinkler Finish
7. Escutcheon Finish (where applicable)
Maintenance
The Models F1 56 and F1 56 Recessed Sprinklers
should be inspected quarterly and the sprinkler system
maintained in accordance with NFPA 25. Do not clean
sprinklers with soap and water, ammonia or any other
cleaning fluid. Remove any sprinkler which has been
painted (other than factory applied) or damaged in any
way. A stock of spare sprinklers should be maintained to
allow quick replacement of damaged or operated
sprinklers. Prior to installation, sprinklers should be
maintained in the original cartons and packaging until
used to minimize the potential for damage to sprinklers
that would cause improper operation or non-operation.
Note: When Model F1FR 56 Recessed Sprinklers are
ordered, the sprinklers and escutcheons are packaged
separately.
Escutcheon
Model Approvals Adjustment "A"
Dimension
Face of Fitting to
Ceiling or Wall
Dimension
F1 1, 2 Max Recessed
Min Recessed
112"
(38.1mm)
84"
(19.1mm)
316"-1116"
(5mm - 24mm)
F2 1, 2, 3 Max Recessed
Min Recessed
112"
(38.1mm)
1"
(25mm)
316"-1116"
(5mm - 24mm)
FP Push-on/
Thread-off
1, 2 Max Recessed 719"
(11mm)
112"
(38.1mm)
1, 2 Min Recessed 15 16"
(24mm)
1"
(25mm)
Escutcheon Data
No Dimensional Figure for FP
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research
Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
The Reliable Automatic Sprinkler Co., Inc.
(800) 431–1588 Sales Offices
(800) 848–6051 Sales Fax
(914) 829–2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by
Revision lines indicate updated or new data
Recycled
Paper
EG. Printed in U.S.A. 8/07 P/N9999970299
•Automatic sprinklers
•Flush automatic sprinklers
•Recessed automatic sprinklers
•Concealed automatic sprinklers
•Adjustable automatic sprinklers
•Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
•Water flow detectors
Reliable...ForCompleteProtection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
•Deluge valves
•Detector check valves
•Check valves
•Supertrol electrical system
•Sprinkler emergency cabinets
•Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gauges
• Identification signs
•Fire department connections

This manual suits for next models

1

Other Reliable Irrigation System manuals

Reliable F1 Series Manual

Reliable

Reliable F1 Series Manual

Reliable JL-14 User manual

Reliable

Reliable JL-14 User manual

Reliable G5-56 Dry User manual

Reliable

Reliable G5-56 Dry User manual

Reliable DH56 HSW User manual

Reliable

Reliable DH56 HSW User manual

Reliable F1FR56 User manual

Reliable

Reliable F1FR56 User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable DH80 Manual

Reliable

Reliable DH80 Manual

Reliable F1S5 Series User manual

Reliable

Reliable F1S5 Series User manual

Reliable DH56 HSW-PL Manual

Reliable

Reliable DH56 HSW-PL Manual

Reliable N25 User manual

Reliable

Reliable N25 User manual

Reliable RFS42 User guide

Reliable

Reliable RFS42 User guide

Reliable KFR56 User manual

Reliable

Reliable KFR56 User manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable F156 EC Series User manual

Reliable

Reliable F156 EC Series User manual

Reliable XL Commercial User manual

Reliable

Reliable XL Commercial User manual

Reliable F1FR-SS Series Manual

Reliable

Reliable F1FR-SS Series Manual

Reliable F3QR80 Series User manual

Reliable

Reliable F3QR80 Series User manual

Reliable RFC30 User manual

Reliable

Reliable RFC30 User manual

Reliable F1XLH Series User manual

Reliable

Reliable F1XLH Series User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F1FR56-300 QREC Series Manual

Reliable

Reliable F1FR56-300 QREC Series Manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable XL Manual

Reliable

Reliable XL Manual

Reliable G4 User manual

Reliable

Reliable G4 User manual

Popular Irrigation System manuals by other brands

Blumfeldt 10031357 manual

Blumfeldt

Blumfeldt 10031357 manual

Tyco Fire Product CENTRAL ESFR-25 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL ESFR-25 instruction manual

Eden 96216EDAMZ instructions

Eden

Eden 96216EDAMZ instructions

Autopot easy2grow 80 Set-up guidelines

Autopot

Autopot easy2grow 80 Set-up guidelines

Orbit Voyager II 55072 instructions

Orbit

Orbit Voyager II 55072 instructions

RedMax DA-EX850 Operator's manual

RedMax

RedMax DA-EX850 Operator's manual

Viking VK506 Technical data

Viking

Viking VK506 Technical data

Tyco Fire Product Star PH-2 instruction manual

Tyco Fire Product

Tyco Fire Product Star PH-2 instruction manual

Komet Pivot operating instructions

Komet

Komet Pivot operating instructions

Hunter Professional Series manual

Hunter

Hunter Professional Series manual

HD FIRE PROTECT HD 104 quick start guide

HD FIRE PROTECT

HD FIRE PROTECT HD 104 quick start guide

Netafim MegaNet 15D user manual

Netafim

Netafim MegaNet 15D user manual

AL-KO AQUATROLLEY A 300 manual

AL-KO

AL-KO AQUATROLLEY A 300 manual

Sime SMART quick start guide

Sime

Sime SMART quick start guide

Viking VK1021 Technical data

Viking

Viking VK1021 Technical data

Tyco EC-8 Series quick start guide

Tyco

Tyco EC-8 Series quick start guide

Rain Bird 7005 Operation guide

Rain Bird

Rain Bird 7005 Operation guide

Strongway 49508 owner's manual

Strongway

Strongway 49508 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.