manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Reliable
  6. •
  7. Irrigation System
  8. •
  9. Reliable F1FR User manual

Reliable F1FR User manual

Model F1FR/CCP
Concealed
Quick Response
Sprinkler
The Reliable Automatic Sprinkler Co., Inc.,103 Fairview Park Drive, Elmsford, New York 10523
Features:
1. Quick response performance.
2. Push on, thread off, sturdy convenient
cover plate.
3. Factory assembled sprinkler and cup,
shipped complete with protective cap.
4. Sprinkler assembly and cover plate
separately packaged.
5. Two versions:
•½²(13mm) Adjustment.
•516"(8mm) Adjustment.
6. Rugged damage resistant assembly.
No exposed thermal element.
7. Utilizes Model F1FR Pendent
Sprinkler.
8. Aesthetic ceiling profile.
9. Available in white or other color
painted or brass, chrome or black
plated finishes.
Product Description
The Reliable Model F1FR/CCP Quick Response
Concealed Sprinkler is an attractive, low profile
concealed sprinkler assembly. This sprinkler
assembly utilizes a Model F1FR pendent sprinkler in
a Model CCP cup and cover plate assembly. The cup
is securely factory threaded on the sprinkler inlet
end. The assembly is shipped with a protective cap.
The sprinkler and cup are easily installed into the
drop nipple using the Model RC1 Sprinkler Wrench.
The cover plate assembly is attached to the sprinkler
cup using a cover plate assembly with flexible tabs
for threaded engagement. Simply push on the cover
plate, then turn to adjust or remove the cover plate
assembly.
The cover plate is attached to the skirt using 135°F
(57°C) or 165°F(74°C) ordinary temperature classification
solder. When the ceiling temperature rises, the solder
holding the cover plate melts, allowing the release of this
part and thus exposing the Model F1FR sprinkler inside to
the rising ambient temperature.
The Model F1FR automatic sprinkler, utilizes a 3mm
frangible glass bulb. This sprinkler has demonstrated
response times in laboratory tests which are five to ten
times faster than standard response sprinklers. This
quick response enables the Model F1FR sprinkler to
apply water to a fire much faster than standard sprinklers
of the same temperature rating.
The glass bulb consists of an accurately controlled
amount of special fluid hermetically sealed inside a
precisely manufactured glass capsule. This glass bulb is
specially constructed to provide fast thermal response.
The other sprinkler parts are made of brass, copper and
beryllium nickel.
At normal temperatures, the glass bulb contains the
fluid in both the liquid phase and vapor phase. The vapor
phase can be seen as a small bubble. As heat is applied
the liquid expands, forcing the bubble smaller and
smaller as the liquid pressure increases. Continued
heating forces the liquid to push out against the bulb,
causing the glass to shatter, opening the waterway and
allowing the deflector to distribute water.
The temperature rating of the sprinkler is identified by
the color of the glass bulb.
Bulletin 143 Rev.D
Bulletin 143 Rev.D
Application and Installation
The Model F1FR/ CCP Concealed Sprinkler uses the ½²
orifice, ½²NPT (R½), 135°F(57°C), 155°F(68°C), 175°F
(79°C) or 200°F(93°C) Model F1FR Pendent Sprinkler with
a threaded Model CCP cup which is factory attached to
the sprinkler. The assembly is completed by the
installation of the attractive, low profile, 135°F(57°C) or
165°F(74°C) rated Model CCP push on cover plate
assembly. The cover plate and sprinkler cup assemblies
are joined using a cover plate skirt with flexible tabs for
threaded engagement. A choice of two cover plate
assemblies provide either ½²(13mm) or 5/16" (8mm) of
cover adjustment.
Do not install these sprinklers in ceiling which have
positive pressure in the space above.
After a 258"(67mm) diameter hole is cut in the ceiling, the
sprinkler is easily installed with the Model RC1 Wrench. A
Teflon*based thread sealant should be applied to the
sprinkler threads only. The Model RC1 Wrench is then
used to engage the sprinkler wrenching surfaces and to
install the sprinkler in the fitting. When inserting or
removing the wrench from the sprinkler/cup assembly,
care should be taken to prevent damage to the sprinkler.
DO NOT WRENCH ON ANY OTHER PART OF THE
SPRINKLER. The cover plate is then pushed onto the cup.
Final adjustment is made by hand turning the cover plate
until the skirt flange makes full contact with the ceiling.
Cover plate removal requires turning in the counter
clockwise direction.
After installation, inspect all sprinklers to ensure that there
is a gap between the cover plate and ceiling and that the
four cup slots are open and free from any air flow
impediment to the space above.
Concealed cover plate/cup assemblies are listed only for
use with specific sprinklers. The use of any other
concealed cover plate/cup assembly with the Model F1FR
Pendent Sprinkler or the use of the Model CCP Concealed
cover plate assembly on any sprinkler with which it is not
specifically listed my prevent good fire protection and will
void all guarantees, warranties, listings and approvals.
Maintenance
Model F1FR/CCP Concealed Sprinklers should be
inspected quarterly and the sprinkler system maintained in
accordance with NFPA 25. Do not clean sprinklers with
soap and water, ammonia or any other cleaning fluids.
Remove dust by using a soft brush or gentle vacuuming.
Remove any sprinkler cover plate assembly which has been
painted (other than factory applied) or damaged in any way.
A stock of spare sprinklers should be maintained to allow
quick replacement of damaged or operated sprinklers. Prior
to installation, sprinklers should be maintained in the original
cartons and packaging until used to minimize the potential
for damage to sprinklers that would cause improper
operation or non-operation.
Approval Organizations
1. Underwriters Laboratories, Inc.
2. Underwriters’ Laboratories of Canada.
3. NYC MEA 258-93-E
ULI Listing Category
Sprinklers, Automatic and Open.
Quick Response, Concealed
Ordering Information
Specify
1. Sprinkler Model F1FR
½²(13mm) orifice, ½²NPT (R½)
2. Sprinkler Temp. Rating:
135°F (56°C), 155°F (68°C), 175°F (79°C), 200°F (93°C)
3. Cover Plate Model: CCP
4. Cover Plate Thread size: ½²NPT (R½)
5. Cover Plate Temp. rating:135°F (56°C) for 135°F (56°C) and
155°F (68°C) Spks165°F (74°C) for 175°F (79°C) and 200°F
(93°C) Spks
6. Cover plate adjustment.
Either ½²(13mm) or 516²(approximate adjustment)
7. Cover Plate Finish
Installation Wrench
Model RC1 Sprinkler Wrench
Installation Aid
A protective cap is included for use during installation.
Note: Paint or any other coatings applied over the factory finish will
void all approvals and warranties. Sprinklers and cup/ cover plate
assemblies are packaged separately.
Important: The F1FR Sprinkler with Model CCP cover plate is not
an FM Approved combination.
Nominal
Orifice
"K" Factor Thread
Size Model
Temp. Rating Max.
Ambient
Temp Bulb Color Approvals
Sprinkler
Identification
Number(SIN)
US Metric Sprinkler Cover
12²(15mm) 5.62 81.0 12²NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°COrange 1, 2, 3 R3615
12²(15mm) 5.62 81.0 12²NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°CRed 1, 2, 3 R3615
12²(15mm) 5.62 81.0 12²NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°CYellow 1, 2, 3 R3615
12²(15mm) 5.62 81.0 12²NPT F1FR 200°F/93°C 165°F/74°C 100°F/38°CGreen 1, 2, 3 R3615
Model F1FR Concealed Pendent Sprinkler
Technical Data
*DuPont Registered Trademark
Standard Finishes
Chrome
White
Special Applications Finishes
Bright Brass
Satin
Off-White
Black Paint
Black Plating
Cover Plate Finishes
2.
(1) Other finishes and colors are available. Consult factory for details.
Figure 1
Figure 2
3.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 70 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Revision lines indicate updated or new data.
E.G. Printed in U.S.A 12/00 P/N 9999970122
Recycled
Paper
Manufactured by
Reliable...For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
•Automatic sprinklers
•Flush automatic sprinklers
•Recessed automatic sprinklers
•Concealed automatic sprinklers
•Adjustable automatic sprinklers
•Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
•Water flow detectors
•Deluge valves
•Detector check valves
•Check valves
•Supertrol electrical system
•Sprinkler emergency cabinets
•Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gauges
• Identification signs
•Fire department connection

Other Reliable Irrigation System manuals

Reliable G5-56 Dry User manual

Reliable

Reliable G5-56 Dry User manual

Reliable G6-56 User manual

Reliable

Reliable G6-56 User manual

Reliable F1 LO User manual

Reliable

Reliable F1 LO User manual

Reliable G4 User manual

Reliable

Reliable G4 User manual

Reliable RFC43 User manual

Reliable

Reliable RFC43 User manual

Reliable G4-300 User manual

Reliable

Reliable G4-300 User manual

Reliable DH80 Dry User manual

Reliable

Reliable DH80 Dry User manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable F3QR80 Series User manual

Reliable

Reliable F3QR80 Series User manual

Reliable F1FR56 Manual

Reliable

Reliable F1FR56 Manual

Reliable F1FR LO Series Manual

Reliable

Reliable F1FR LO Series Manual

Reliable GFR Series User manual

Reliable

Reliable GFR Series User manual

Reliable F1FR-300 User manual

Reliable

Reliable F1FR-300 User manual

Reliable RFS42 User guide

Reliable

Reliable RFS42 User guide

Reliable F1FR80 Series User manual

Reliable

Reliable F1FR80 Series User manual

Reliable GXLO Series Manual

Reliable

Reliable GXLO Series Manual

Reliable DH56 Dry User manual

Reliable

Reliable DH56 Dry User manual

Reliable GFR User manual

Reliable

Reliable GFR User manual

Reliable F1 Res 30 LL User manual

Reliable

Reliable F1 Res 30 LL User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable F1FR-FS LO User manual

Reliable

Reliable F1FR-FS LO User manual

Reliable F1FR Series Manual

Reliable

Reliable F1FR Series Manual

Reliable F1FR-FS56 Manual

Reliable

Reliable F1FR-FS56 Manual

Popular Irrigation System manuals by other brands

Cellfast MULTI TT IDEAL 52-065 user manual

Cellfast

Cellfast MULTI TT IDEAL 52-065 user manual

Perrot Hydra M VAC operating manual

Perrot

Perrot Hydra M VAC operating manual

Tyco Fire Product Star Luminous S178 instruction manual

Tyco Fire Product

Tyco Fire Product Star Luminous S178 instruction manual

Viking FREEDOM VK460 Technical data

Viking

Viking FREEDOM VK460 Technical data

HI-FOG 1900 IDENTIFICATION AND CORRECTION PROCEDURE

HI-FOG

HI-FOG 1900 IDENTIFICATION AND CORRECTION PROCEDURE

TrimmerPlus LD720 Operator's manual

TrimmerPlus

TrimmerPlus LD720 Operator's manual

Tyco ESFR-1 Assembly instructions

Tyco

Tyco ESFR-1 Assembly instructions

Tyco F08 FIP Operator's manual

Tyco

Tyco F08 FIP Operator's manual

Toro 53763 Installation and operating instructions

Toro

Toro 53763 Installation and operating instructions

Tyco Fire Product SIN S3230 manual

Tyco Fire Product

Tyco Fire Product SIN S3230 manual

Viking VK570 Technical data

Viking

Viking VK570 Technical data

Hunter Sprinkler System Design handbook

Hunter

Hunter Sprinkler System Design handbook

Tyco ESFR-14 quick start guide

Tyco

Tyco ESFR-14 quick start guide

Schier SV24 installation guide

Schier

Schier SV24 installation guide

Toro MultiMatix 720G Adjustment instructions

Toro

Toro MultiMatix 720G Adjustment instructions

CENTRAL A-1 manual

CENTRAL

CENTRAL A-1 manual

Tyco Fire Product CENTRAL H-1 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL H-1 instruction manual

Tyco Fire Product Star StarMax S100 instruction manual

Tyco Fire Product

Tyco Fire Product Star StarMax S100 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.