manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Reliable
  6. •
  7. Irrigation System
  8. •
  9. Reliable G User manual

Reliable G User manual

Open
Sprinklers
Bulletin 104 Rev.M
Reliable Models G & F1 Open Sprinklers are similar
in design to Reliable Models G & F1 Automatic
Sprinklers except they are not equipped with fusible
or frangible element parts, and therefore, do not
operate automatically. They are installed in locations
where a blanket of water is desired over a
predetermined area. Open Sprinkler systems can be
operated manually or by quick opening valves that
are pneumatically, hydraulically or electrically
controlled.
Open Sprinklers are available in four types:
Standard Upright, Standard Pendent, Conventional.
and Sidewall.
All Open Sprinklers are available in the following
finishes: Plain Bronze, lead plated wax coated or wax
coated over lead plated. No waterway protection is
provided. Consult factory for other finishes.
The following table lists Reliable Open Sprinklers by
type, orifice size, pipe connection size, overall length,
installation position and SIN.
Installation positions other than the design
installation position shown in the table may be used.
However, the resulting distribution pattern in the
installed position must be carefully considered.
Type
Orifice
Size
NPT
Thread
K Factor
Overall
Length
Installation
Position
Sprinkler
Identification
Number (SIN)US Metric
Standard Upright
(Model G)
516", 38", 716"
12"
1732"
12"
12"
12", 34"
1.98, 2.82,4.24
5.62
7.96,8.20
30, 40, 60,
80,
115
278"
278"
278", 21516"
Upright
Upright
Upright
R1022, R1021, R1023
R1025,
R1026, R1027
Standard Pendent
(Model G)
516", 38", 716"
12"
1732
12"
12"
12", 34"
1.98,2.82,4.24
5.62
7.96,8.20
30, 40, 60,
80,
115
278"
278"
278", 21516"
Pendent
Pendent
Pendent
R1012, R1011, R1013
R1015,
R1016, R1017
Conventional
(Model G)
12"
1732"
12"
34"
5.62
8.20
80,
115
278"
21516"
Upright or Pendent
Upright or Pendent
R1075,
R1077
Sidewall
(Model G)
12"
12"
12"
12"
5.62
5.62
80,
80
278"
3516"
Upright or Pendent
Horizontal
R1285,
R1235
Standard Upright
(Model F1)
38", 716"
12"
1732"
12"
12"
34"
2.82,4.24
5.62
8.00
40, 60
80,
115
2.20"
2.20"
2.31"
Upright
Upright
Upright
R1721, R1713
R1725
R1722
Standard Pendent
(Model F1)
38", 716"
12"
1732"
12"
12"
34"
2.82,4.24
5.62
8.00
40, 60,
80,
115
2.20"
2.20"
2.31"
Pendent
Pendent
Pendent
R1711, R1713
R1715
R1712
Conventional
(Model F1)
12"
1732"
12"
34"
5.62
8.00
80,
115
2.20"
2.30"
Upright or Pendent
Upright or Pendent
R1775
R1772
Sidewall
(Model F1)
12"
12"
12"
12"
5.62
5.62
80,
80
2.20"
2.63"
Upright or Pendent
Horizontal
R1785
R1735
Refer to the appropriate automatic sprinkler product bulletins for listing and approval information.
The Reliable Automatic Sprinkler Co., Inc. • 103 Fairview Park Drive • Elmsford, New York 10523
Bulletin104Rev.M
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual
Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
The Reliable Automatic Sprinkler Co., Inc.
(800) 431–1588 Sales Offices
(800) 848–6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by
Model G & F1 - Open Standard (Spray) Upright
and Pendent Sprinklers
Models G and F1 standard upright and pendent
sprinklers distribute water laterally and downward in a
wide pattern approximating a half sphere. This
hemisphere is completely and uniformly filled with water
in the form of small drops and spray. A circular area, from
12 to about 20 ft. (3.7 to 6.1m) in diameter, is covered 10
ft. (3.0m) below the sprinkler at minimum water discharge
pressure. See Technical Bulletins 110 and 117.
Model F1
Standard Upright
Model G
Standard Pendent
Model G & F1 - Conventional Open Style Sprinkler
This deflector configuration is used primarily in those
countries where the LPC installation rules have
precedence. The sprinkler distributes approximately 60%
of its water discharge upward against the ceiling with the
balance downward. It may be installed in either the upright
or pendent position. Sprinklers with conventional
deflectors are available with orifice sizes corresponding to
light, ordinary and extra–hazard installations.
See Technical Bulletins 110 and 117.
Model G & F1 - Open Sidewall Sprinklers
This deflector configuration is designed for use where
standard sprinklers are deemed impartial because of
decorative or structural conditions. It discharges
approximately 15% of the water on the wall behind it with
the remaining 85% discharged in front of the sprinkler.
The Model G & F1 Vertical Sidewall Sprinklers may be
installed in either the upright or the pendent position, and
are intended for light hazard occupancy use.
The Model G & F1 Horizontal Sidewall Sprinklers are
intended for light hazard occupancies and in some
applications may be used in ordinary hazard
occupancies.
See Technical Bulletins 112 and 117.
Model G
Vertical Sidewall
Model F1
Horizontal Sidewall
For specific water distribution information, refer to the
spray distribution section of the catalog.
Recycled
Paper
Revision lines indicate updated or new data.
P.G. Printed in U.S.A. 12/06 P/N 9999970003
Model G
Standard Conventional Model F1
Standard Conventional
Model F1
Standard Pendent
Model G
Standard Upright
Model G
Horizontal Sidewall

This manual suits for next models

28

Other Reliable Irrigation System manuals

Reliable Non-Ferrous Concealer User manual

Reliable

Reliable Non-Ferrous Concealer User manual

Reliable F1-42 Series Manual

Reliable

Reliable F1-42 Series Manual

Reliable F1-SS Series User manual

Reliable

Reliable F1-SS Series User manual

Reliable RFC30 User manual

Reliable

Reliable RFC30 User manual

Reliable RFC30 LL User manual

Reliable

Reliable RFC30 LL User manual

Reliable F1FR56-300 QREC Series Manual

Reliable

Reliable F1FR56-300 QREC Series Manual

Reliable N25 ESFR User manual

Reliable

Reliable N25 ESFR User manual

Reliable DH56 HSW-PL Manual

Reliable

Reliable DH56 HSW-PL Manual

Reliable F1S5 Series User manual

Reliable

Reliable F1S5 Series User manual

Reliable F1S5-FSLO User manual

Reliable

Reliable F1S5-FSLO User manual

Reliable F4FR User manual

Reliable

Reliable F4FR User manual

Reliable N252 EC Pendent User manual

Reliable

Reliable N252 EC Pendent User manual

Reliable KFR56 User manual

Reliable

Reliable KFR56 User manual

Reliable F1FR56 User manual

Reliable

Reliable F1FR56 User manual

Reliable F4FR-NF Manual

Reliable

Reliable F4FR-NF Manual

Reliable Pantman F1 User manual

Reliable

Reliable Pantman F1 User manual

Reliable GXLO Series Manual

Reliable

Reliable GXLO Series Manual

Reliable SWC Manual

Reliable

Reliable SWC Manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable HL22 Manual

Reliable

Reliable HL22 Manual

Reliable G6-56 User manual

Reliable

Reliable G6-56 User manual

Reliable The Non-Ferrous Concealer F4FR-NF User manual

Reliable

Reliable The Non-Ferrous Concealer F4FR-NF User manual

Reliable F1FR56 Manual

Reliable

Reliable F1FR56 Manual

Reliable F1FR-FS56 User manual

Reliable

Reliable F1FR-FS56 User manual

Popular Irrigation System manuals by other brands

Sime SMART quick start guide

Sime

Sime SMART quick start guide

Tyco Fire Product CENTRAL DS-2 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL DS-2 instruction manual

Westfalia 92 32 73 Original instructions

Westfalia

Westfalia 92 32 73 Original instructions

Tyco G2 manual

Tyco

Tyco G2 manual

Perrot Hydra M VAC operating manual

Perrot

Perrot Hydra M VAC operating manual

claber 8053 instruction manual

claber

claber 8053 instruction manual

Toro T5 Series quick start guide

Toro

Toro T5 Series quick start guide

ARABLE MARK quick start guide

ARABLE

ARABLE MARK quick start guide

Elgo READY 2 DRIP installation guide

Elgo

Elgo READY 2 DRIP installation guide

Senju Sprinkler RC-QR manual

Senju Sprinkler

Senju Sprinkler RC-QR manual

Tyco TY-B Series quick guide

Tyco

Tyco TY-B Series quick guide

TrimmerPlus LD720 Operator's manual

TrimmerPlus

TrimmerPlus LD720 Operator's manual

Senninger i-Wob UP3 Recommended installation

Senninger

Senninger i-Wob UP3 Recommended installation

Tyco CC2 quick start guide

Tyco

Tyco CC2 quick start guide

General Air Products Vapor Pipe Shield VPS-500A Installation, operation and maintenance manual

General Air Products

General Air Products Vapor Pipe Shield VPS-500A Installation, operation and maintenance manual

Task Force Tips FM Series INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

Task Force Tips

Task Force Tips FM Series INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

Johnson Controls tyco TFP700 manual

Johnson Controls

Johnson Controls tyco TFP700 manual

Cellfast SZ IDEAL 52-061 user manual

Cellfast

Cellfast SZ IDEAL 52-061 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.