manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Reliable
  6. •
  7. Irrigation System
  8. •
  9. Reliable F1FR LO Series Manual

Reliable F1FR LO Series Manual

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1FR LO Large Orifice
Model F1FR LO Large
Orifice Recessed Quick
Response Sprinklers With
1/2” connection Thread
Model F1FR LO
Large Orifice
Sprinkler Types
Standard Upright
Standard Pendent
Model F1FR LO
Large Orifice
Recessed Sprinkler Types
Recessed Pendent
Approvals
VdS Schadenverhütung GmbH: Certificate
EC Certificate: 0786-CPD-40282 (RA3812), 0786-CPD-40283
(RA3822)
Product Description
Reliable Models F1FR LO and F1FR LO Recessed Sprinklers
are quick response sprinklers which combine the durability of a
standard sprinkler with the attractive low profile of a decorative
sprinkler.
The Models F1FR LO and F1FR LO Recessed automatic
sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers
have demonstrated response times in laboratory tests which
are five to ten times faster than standard response sprinklers.
This quick response enables the Model F1FR LO and F1FR LO
Recessed sprinklers to apply water to a fire much faster than
standard sprinklers of the same temperature rating.
The glass bulb consists of an accurately controlled amount of
special fluid hermetically sealed inside a precisely manufactured
glass capsule. This glass bulb is specially constructed to provide
fast thermal response. The balance of parts are made of brass,
copper and beryllium nickel.
At normal temperatures, the glass bulb contains the fluid in
both the liquid and vapor phases. The vapor phase can be seen
as a small bubble. As heat is applied, the liquid expands, forcing
the bubble smaller and smaller as the liquid pressure increases.
Continued heating forces the liquid to push out against the bulb,
causing the glass to shatter, opening the waterway and allowing
the deflector to distribute the discharging water.
The temperature rating of the sprinkler is identified by the
color of the glass bulb.
Application
Quick response sprinklers are used in fixed fire protection
systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector
style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Association
or the approving Authority Having Jurisdiction. Quick response
sprinklers are intended for installation as specified in NFPA 13,
FM Global Loss Prevention Data Sheet 2-8N or other applicable
standards. Quick response sprinklers and standard response
sprinklers should not be intermixed.
Upright Pendent
Recessed Pendent
Multilingualdocument:
Select your language below
Bulletin 038 Rev. A_Multilingual
Bulletin 038 Rev. A_Multilingual
2
136FG01_F 136FG05_B
Model F1FR LO Quick Response Upright and Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Sprinkler Type K-Factor Sprinkler Height Sprinkler Identification Number (SIN)
US Metric
Standard-Upright (SSU) and pendent (SSP) Deflectors
Marked to Indicate Position SSU SSP
17/32” (20 mm) Large Orifice
with R
1/2” Thread 8.0 115 2.3” (58 mm) RA3822 RA3812
Upright Pendent
Model F1FR LO Quick Response Recessed Pendent Sprinkler(1)(2)
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Orifice Thread
Size “T”
Nominal K-Factor Sprinkler Height Sprinkler Identification Number (SIN)
US Metric
17/32” (20 mm) R
1/2”8.0 115 2.3” (58 mm) RA3812
(1) Refer to escutcheon data table for dimensions
(2) Currently not VdS Approved.
Fig. 2Fig. 1
TURN COLLAR
UNTIL TIGHT
AGAINST SPRINKLER
WRENCH BOSS
1” x“T” REDUCER
FACE OF FITTINGTO (1)
CEILING DIMENSION
2 1/4” HOLE DIA.
(57.2 mm)
1 15/16” DIA.
(49.2 mm)
ADJUSTMENT (1)
2 27/32” DIA.
(72.2 mm)
1/8”
(3.2 mm)“A” (1)
(1) REFER TO F1 & F2 ESCUTCHEON DATA TABLE FOR DIMENSIONS
FACE OF FITTINGTO (1)
CEILING DIMENSION
1” x“T” REDUCER
ADJUSTMENT (1)
CEILING
2 5/8” DIA. (66.7 mm)
HOLE IN CEILING
2 5/16” DIA. (58.7 mm) CUP
(1) REFER TO FP ESCUTCHEON DATA TABLE FOR DIMENSIONS
“A” (1)
3
Installation
Quick response sprinklers are intended for installation as
specified in NFPA 13, FM Global Loss Prevention Data Sheet
2-8N or other applicable standards. Quick response sprinklers
and standard response sprinklers should not be intermixed.
The Model F1FR LO Recessed Quick Response Sprinklers
are to be installed as shown. The Model F1 or F2 Escutcheons
illustrated are the only recessed escutcheons to be used with
the Model F1FR LO Sprinklers. The use of any other recessed
escutcheon will void all approvals and negate all warranties.
When installing Model F1FR LO Sprinklers, use the Model D
Sprinkler Wrench. When installing Model F1FR LO Recessed
Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler
Wrench. Any other type of wrench may damage these sprinklers.
Glass bulb sprinklers have orange bulb protectors to minimize
bulb damage during shipping, handling and installation.
REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER
SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION.
Removal of the protectors before this time may leave the bulb
vulnerable to damage. RASCO wrenches are designed to install
sprinklers when covers are in place. REMOVE PROTECTORS
BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS
TO REMOVE THE PROTECTORS.
Temperature Ratings
Classification
Sprinkler
Temperature
Maximum
Ambient
Temperature
Bulb
Color
°F °C °F °C
Ordinary 135 57 100 38 Orange
Ordinary 155 68 100 38 Red
Intermediate 175 79 150 66 Yellow
Intermediate 200 93 150 66 Green
High(1) 286 141 225 107 Blue
(1) Not Available for recessed sprinklers.
Escutcheon Data
Escutcheon
Model Adjustment “A”
Dimension
Face of Fitting to
Ceiling or Wall
Dimension
F1 Max Recess
Min Recess 1
1/2” (38.1 mm)
3/4” (19.1 mm)
3/16” - 15/16”
(5 mm - 24 mm)
F2 Max Recess
Min Recess 1
1/2” (38.1 mm)
1” (24.5 mm)
3/16” - 11/16”
(5 mm - 17 mm)
FP Push-on/
Thread-off Max Recessed
Min Recessed
5/16” (8 mm)
15/16” (24 mm) 1
1/2” - 1”
(38.1 mm - 25.4 mm)
Maintenance
TheModelsF1FRLOandF1FRLORecessedSprinklersshould
be inspected quarterly and the sprinkler system maintained in
accordance with NFPA 25. Do not clean sprinklers with soap
and water, ammonia or any other cleaning fluids. Remove
dust by using a soft brush or gentle vacuuming. Remove any
sprinkler which has been painted (other than factory applied)
or damaged in any way. A stock of spare sprinklers should be
maintained to allow quick replacement of damaged or operated
sprinklers. Prior to installation, sprinklers should be maintained
in the original cartons and packaging until used to minimize the
potential for damage to sprinklers that would cause improper
operation or non-operation.
Sprinkler Types
Standard Upright
Standard Pendent
Recessed Pendent
Finishes(1)(2)
Standard Finishes
Sprinkler Escutcheon
Bronze
Chrome Plated
White Polyester Coated
Brass
Chrome Plated
White Painted
Special Application Finishes
Sprinkler Escutcheon
Bright Brass
Black Plated
Black Paint
Off White
Satin Chrome
Bright Brass
Black Plated
Black Paint
Off White
Satin Chrome
(1) Other finishes and colors are available on special order. Consult the
factory for details.
(2) FP Push-on/Thread-off escutcheon.
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
6. Sprinkler Finish
7. Escutcheon Type
8. Escutcheon Finish (where applicable)
Note: When Model F1FR LO Recessed sprinklers are ordered,
the sprinklers and escutcheons are packaged separately.
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by Recycled
Paper
Revision lines indicate updated or new data.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products
manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Reliable... For Complete Protection
• Automatic sprinklers
• Flush automatic sprinklers
• Recessed automatic sprinklers
• Concealed automatic sprinklers
• Adjustable automatic sprinklers
• Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
• Water flow detectors
• Deluge valves
• Detector check valves
• Check valves
• Electrical system
• Sprinkler emergency cabinets
• Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gauges
• Identification signs
• Fire department connection
EG. Printed in U.S.A 09/14 P/N 9999970414

This manual suits for next models

4

Other Reliable Irrigation System manuals

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F1FR56-300 Series Manual

Reliable

Reliable F1FR56-300 Series Manual

Reliable F156 EC Series User manual

Reliable

Reliable F156 EC Series User manual

Reliable F3-56 Series User manual

Reliable

Reliable F3-56 Series User manual

Reliable F1FR56 User manual

Reliable

Reliable F1FR56 User manual

Reliable G5-56 Dry User manual

Reliable

Reliable G5-56 Dry User manual

Reliable G Series Manual

Reliable

Reliable G Series Manual

Reliable F3QR User manual

Reliable

Reliable F3QR User manual

Reliable F1FR-SS Series User manual

Reliable

Reliable F1FR-SS Series User manual

Reliable RFS42 Manual

Reliable

Reliable RFS42 Manual

Reliable F1FR-FS Series User manual

Reliable

Reliable F1FR-FS Series User manual

Reliable F3QR80 Series User manual

Reliable

Reliable F3QR80 Series User manual

Reliable G4A-300 User manual

Reliable

Reliable G4A-300 User manual

Reliable F4FR User manual

Reliable

Reliable F4FR User manual

Reliable F3-80 Dry Pendent User manual

Reliable

Reliable F3-80 Dry Pendent User manual

Reliable N252 EC User manual

Reliable

Reliable N252 EC User manual

Reliable F1FR User manual

Reliable

Reliable F1FR User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F1FR56-300 QREC Series Manual

Reliable

Reliable F1FR56-300 QREC Series Manual

Reliable F3QR56 User manual

Reliable

Reliable F3QR56 User manual

Reliable RFC30 User manual

Reliable

Reliable RFC30 User manual

Reliable DH56 HSW User manual

Reliable

Reliable DH56 HSW User manual

Reliable F1-SS Series User manual

Reliable

Reliable F1-SS Series User manual

Reliable F1FR40 Manual

Reliable

Reliable F1FR40 Manual

Popular Irrigation System manuals by other brands

Rain Bird 32SA quick start guide

Rain Bird

Rain Bird 32SA quick start guide

Tyco TY-B Series quick start guide

Tyco

Tyco TY-B Series quick start guide

claber AQUAUNO MIST user manual

claber

claber AQUAUNO MIST user manual

Toro XP300-02 Installation and service instructions

Toro

Toro XP300-02 Installation and service instructions

Perrot ZX30 Series Operation manual

Perrot

Perrot ZX30 Series Operation manual

CEA 4001 Planning and installation

CEA

CEA 4001 Planning and installation

Tyco TY-L Series quick start guide

Tyco

Tyco TY-L Series quick start guide

claber Aqua-Magic System user manual

claber

claber Aqua-Magic System user manual

Viking MicrofastHP VK341 Technical data

Viking

Viking MicrofastHP VK341 Technical data

Cellfast SZ IDEAL 52-061 user manual

Cellfast

Cellfast SZ IDEAL 52-061 user manual

Tyco ELO-231B Series manual

Tyco

Tyco ELO-231B Series manual

Nelson F75 Big Gun Operation & maintenance instructions

Nelson

Nelson F75 Big Gun Operation & maintenance instructions

Eden 94094EDAMZ manual

Eden

Eden 94094EDAMZ manual

Tyco Fire Protection Products ESFR-17 manual

Tyco Fire Protection Products

Tyco Fire Protection Products ESFR-17 manual

Viking VKFD25U Technical data

Viking

Viking VKFD25U Technical data

CENTRAL GBR manual

CENTRAL

CENTRAL GBR manual

Tyco Rapidresponse LFII Series quick start guide

Tyco

Tyco Rapidresponse LFII Series quick start guide

Hozelock 2550 How to use

Hozelock

Hozelock 2550 How to use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.