The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1FR-FS56
Model F1FR-FS42
Quick Response
Flat Spray Sprinklers
Bulletin 022 August 2021
Bulletin 022 August 2021
Models F1FR-FS56 and F1FR-FS42 Flat
Spray Sprinklers
Types
Standard Pendent
Listings & Approvals
F1FR-FS56
• VdS Schadenverhütung GmbH: Certicate
G4080047
• CE Certicate: EC-Certicate of conformity 0786-
CPD-40242
F1FR-FS42
• VdS Schadenverhütung GmbH: Certicate
G414023
• CE Certicate: Certicate of constancy of
performance 0786-CPR-40296
Product Description
The F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
are designed for installation in accordance with CEA 4001
or EN 12845 (Automatic Sprinkler Systems - Design,
Installation and Maintenance). The spray pattern created
by this sprinkler makes this an excellent choice for
applications with lower clearance above the suspended
open ceilings and in racks.
The F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
with shield are used in applications where there are high
and lower level sprinklers. The shield is to help prevent the
lower level sprinklers from getting wet by the higher level
sprinklers.
The F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
utilize a frangible 3.0mm glass bulb. The glass bulb
consists of an accurately controlled amount of special fluid
hermetically sealed inside of a precisely manufactured
glass capsule. This glass bulb is specially constructed to
provide fast thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid phase and in the vapor phase. The vapor
phase can be seen as a small bubble. As heat is applied,
the liquid expands forcing the bubble smaller and smaller
as the liquid pressure increases. Continued heating forces
the liquid to push out against the bulb, causing the glass to
shatter, opening the waterway and allowing the deflector to
distribute the discharging water.
The F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
temperature rating are identied by the color of the glass
bulb capsule.
Pendent
Pendent with shield
Models F1FR-FS56 and F1FR-FS42 Quick Response Pendent Sprinklers
Installation Wrench: Model W2 Sprinkler Wrench
Installation Data:
Sprinkler Type
Standard–Pendent (SSP)
Deflectors Marked to Indicate Position
K Factor Sprinkler
Height
Approval
Organizations
US Metric
1/2” (15mm) Standard Orice with 1/2” NPT Thread 5.6 80 2.25” (57mm) VdS
1/2” (15mm) Standard Orice with R1/2 Thread 5.6 80 2.25” (57mm) VdS
3/8” (10mm) Standard Orice with R1/2 Thread 4.2 57 2.25” (57mm) VdS
Pendent
Model F1FR-FS56 with shield
Models F1FR-FS56 and F1FR-FS42 Quick Response Pendent Sprinklers with shield
Installation Wrench: Model W4 Sprinkler Wrench
Installation Data:
Nominal
Orice
Thread
Size
K Factor Sprinkler
Height
Approval
Organizations
US Metric
1/2” (15mm) 1/2” NPT 5.6 80 2.25” (57mm) VdS
1/2” (15mm) R1/2” BSPT 5.6 80 2.25” (57mm) VdS
3/8” (10mm) R1/2” BSPT 4.2 57 2.25 (57mm) VdS
Shield Data
Part No. Approvals “A”
Dimension
“B”
Dimension
“C”
Dimension
6999995574 VdS 4 17/32”
(115mm)
1 15/16”
(49mm)
9/16”
(14mm)
2.
Models F1FR-FS56, F1FR-FS42 Pendent
Sprinklers, F1FR-FS56 and F1FR-FS42
Pendent Sprinklers with shield
Application
Models F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
are used in concealed spaces, suspended open ceiling
and in racks in accordance with CEA 4001 Sprinkler
System Planning) and EN 12845 (Automatic Sprinkler
Systems - Design Installation and Maintenance).
Installation
Models F1FR-FS56 and F1FR-FS42 Flat Spray Sprinklers
are quick response sprinklers intended for installation as
specied in CEA 4001 and EN 12845. They must also be
installed with the Model W2 Sprinkler Wrench specically
designed by Reliable for use with these sprinklers.
When installing Models F1FR-FS56 and F1FR-FS42
Pendent with shield use the Model W4 Sprinkler Wrench.
Any other type of wrench may damage these sprinklers.
Note: A leak tight ½” NPT sprinkler joint can be obtained
with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not
tighten sprinklers over maximum recommended torque. It
may cause leakage or impairment of the sprinklers.
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orice Size
4. Deflector Type
5. Temperature Rating
- Specify Bulb Size when ordering
6. Sprinkler Finish - Bronze only
Note: When Models F1FR-FS56 and F1FR-FS42
Pendent Sprinklers with shield are ordered, the
sprinklers and shields are packaged separately.
Maintenance
The Models F1FR-FS56, F1FR-FS42 Pendent, F1FR-
FS56 and F1FR-FS42 Pendent Sprinklers with shield
should be inspected quarterly. Do not clean sprinklers
with soap and water, ammonia or any other cleaning fluid.
Remove any sprinkler which has been painted (other than
factory applied) or damaged in any way. A stock of spare
sprinklers should be maintained to allow quick replacement
of damaged or operated sprinklers. Prior to installation,
sprinklers should be maintained in the original cartons and
packaging until used to minimize the potential for damage
to sprinklers that would cause improper operation or non-
operation.
Temperature Ratings
Classication
Sprinkler
Temperature Max. Ambient
Temp.
Bulb
Color
°C °F
Ordinary
Ordinary
Intermediate
Intermediate
High
57
68
79
93
141
135
155
175
200
286
100°F (38°C)
100°F (38°C)
150°F (66°C)
150°F (66°C)
225°F (107°C)
Orange
Red
Yellow
Green
Blue
Finish
Sprinkler Shield
Bronze Galvanized
The Reliable Automatic Sprinkler Co., Inc.
(800)431–1588 Sales Ofces
(800)848–6051 Sales Fax
(914)829–2042 Corporate Ofces
www.reliablesprinkler.com Internet Address
Manufactured by Recycled
Paper
EG. Printed in U.S.A. 08/21 P/N 9999970360
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation,
or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 100 years, and are installed and serviced by the most highly qualied and reputable sprinkler
contractors located throughout the United States, Canada and foreign countries.
Revision lines indicate updated or new data

This manual suits for next models

1

Other Reliable Irrigation System manuals

Reliable F1FR-SS Series User manual

Reliable

Reliable F1FR-SS Series User manual

Reliable HL22 Manual

Reliable

Reliable HL22 Manual

Reliable F1 LO User manual

Reliable

Reliable F1 LO User manual

Reliable JL-14 Manual

Reliable

Reliable JL-14 Manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F1FR Series Manual

Reliable

Reliable F1FR Series Manual

Reliable F1FR80 Series User manual

Reliable

Reliable F1FR80 Series User manual

Reliable DH80 Dry User manual

Reliable

Reliable DH80 Dry User manual

Reliable DH56 HSW-PL Manual

Reliable

Reliable DH56 HSW-PL Manual

Reliable Pantman F1 User manual

Reliable

Reliable Pantman F1 User manual

Reliable F1S5 Series Manual

Reliable

Reliable F1S5 Series Manual

Reliable F1FR-300 User manual

Reliable

Reliable F1FR-300 User manual

Reliable DH56 Dry User manual

Reliable

Reliable DH56 Dry User manual

Reliable A4 User manual

Reliable

Reliable A4 User manual

Reliable DH80 Dry User manual

Reliable

Reliable DH80 Dry User manual

Reliable G4 User manual

Reliable

Reliable G4 User manual

Reliable F156 Series Manual

Reliable

Reliable F156 Series Manual

Reliable F3QR56 User manual

Reliable

Reliable F3QR56 User manual

Reliable G4 User manual

Reliable

Reliable G4 User manual

Reliable F1FR-FS LO Manual

Reliable

Reliable F1FR-FS LO Manual

Reliable F1FR-SS Series User manual

Reliable

Reliable F1FR-SS Series User manual

Reliable J168 User manual

Reliable

Reliable J168 User manual

Reliable G6-80 K8.0 User manual

Reliable

Reliable G6-80 K8.0 User manual

Reliable DD56-6 Manual

Reliable

Reliable DD56-6 Manual

Popular Irrigation System manuals by other brands

Toro MultiMatrix V-1550 Adjustment instructions

Toro

Toro MultiMatrix V-1550 Adjustment instructions

Tyco FASTFLEX YN25 manual

Tyco

Tyco FASTFLEX YN25 manual

Havahart 5266 owner's manual

Havahart

Havahart 5266 owner's manual

Autopot 80 Pot System Set-up guidelines

Autopot

Autopot 80 Pot System Set-up guidelines

K-Rain MiniPro Setting instructions

K-Rain

K-Rain MiniPro Setting instructions

sunjoe AQUAJOE AJ-6PSTB-XL manual

sunjoe

sunjoe AQUAJOE AJ-6PSTB-XL manual

AQUAJOE AJ-IST72ZM user manual

AQUAJOE

AQUAJOE AJ-IST72ZM user manual

Autopot easy2grow 60 Set-up guidelines

Autopot

Autopot easy2grow 60 Set-up guidelines

Vaughan Junior user manual

Vaughan

Vaughan Junior user manual

Tyco Fire Product RAPID RESPONSE LFII Series instruction manual

Tyco Fire Product

Tyco Fire Product RAPID RESPONSE LFII Series instruction manual

Eden 94095EDAMZ manual

Eden

Eden 94095EDAMZ manual

Gardena Sprinkler 380 operating instructions

Gardena

Gardena Sprinkler 380 operating instructions

Tyco Central ESFR-25/WilFlow manual

Tyco

Tyco Central ESFR-25/WilFlow manual

Rain S-Dial installation manual

Rain

Rain S-Dial installation manual

Tyco ESFR-25 quick start guide

Tyco

Tyco ESFR-25 quick start guide

Tyco ESFR-17 manual

Tyco

Tyco ESFR-17 manual

Rain Bird 5000 Plus Series installation instructions

Rain Bird

Rain Bird 5000 Plus Series installation instructions

Nelson RainTrain2 instruction manual

Nelson

Nelson RainTrain2 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.