AMX300 DIRECTCONNECT™ MIXING VALVE KITS
62-3113—05 2
Water inside the water heater is very hot and presents
a scalding hazard.
If the AMX300 mixing valve kit is being installed on a
water heater that is already operational, be careful
when draining the hot water supply lines in
preparation for connecting the mixing valve kit.
Setting Homeowner Expectations
Make sure the homeowners know what to expect from their
AMX300 mixing valve kit. Show the homeowner the
procedure for adjusting the AMX300 mixing valve if, in the
future, they are not satisfied with the temperature of the hot
water delivered to the fixtures in the house. Outline the
potential scalding hazard if the mixed water temperature is
set too high and answer any questions the homeowner may
have.
Recommend to the homeowner that the mixing valve kit be
checked annually to ensure it continues to operate correctly.
These installation instructions must be left with the
homeowner for future reference.
Compliance to ASSE 1017 code requires installation
of a check valve. An expansion tank must be installed
with the check valve to accommodate thermal
expansion.
Important Installation Requirements
Follow professional safety standards and all local
regulations. Consult local plumbing codes prior to installing
the AMX300 mixing valve kit.
PREPARATION FOR
INSTALLATION
The following steps should be taken to ensure proper
conditions for operation:
1. Check the operating conditions (temperature, pressure
and flow rate) of the system where the mixing valve kit
will be installed and ensure they do not exceed the
specifications of the mixing valve (refer to literature #
62-3112, AMX300 Series DirectConnect™ Mixing Valve
Installation Instructions). All specifications must be
met before installing the mixing valve kit.
2. If the water supply is of poor quality, the internal com-
ponents may jam requiring an additional filter or
strainer to be fitted to the system. Contact a plumbing
professional for appropriate materials and installation.
3. This mixing valve kit MUST NOT be subjected to heat
during installation as this may damage the internal
components.
Applying heat to these valves can damage the mixing
valve's internal components, causing it to not
regulate the mixed water temperature properly.
If using sweat fittings to connect the mixing valve kit
to the plumbing system, DO NOT apply heat to the
mixing valve after it is connected to the water heater.
Sweat the copper tubing of the plumbing system to
the threaded adapter before connecting the adapter
to the mixing valve.
4. The valve MUST NOT be allowed to freeze. If the mixing
valve kit is installed in a location where freezing could
occur, suitable insulation must be used to prevent
damage.
5. DO NOT use excess thread sealant (in liquid, tape or
other form) on the NPT threads, as this may cause the
mixing valve kit to fail; ensure that thread sealant does
not get into the internal parts of the mixing valve kit. Do
not use ANY thread sealant on flare connections of the
flexible metal connector.
6. When installing the AMX300 mixing valve kit on a water
heater with a blower mounted on top, the blower unit
must be removed prior to installation of the mixing
valve kit and replaced after the kit is installed. If the
water heater is gas-fired, the mixing valve kit must be
connected to the water heater before the draft hood is
installed. When installing an AMX300 mixing valve kit
on an existing water heater, it may be necessary to
remove the draft diverter and some of the vent sections
before installing the AMX300 mixing valve kit.
7. The AMX300 mixing valve kit is intended for use ONLY
on water heaters in potable water systems. It must
never be installed on a water heater that has previously
been used with a non-potable water heating system,
due to the potential for contamination from toxic mate-
rials used in theses types of systems (e.g. boiler treat-
ment chemicals).
8. Remove all components from the AMX300 mixing valve
kit box and check that all required components are
included. The required components are: AMX300 mix-
ing valve, cold water tee, flexible metal connector, ther-
mostrip and installation instructions (see Fig. 1).
9. The AMX300T kit includes a flexible metal connector
suitable for water heaters with an 8-in. spacing
between the hot and cold water nipples on top of the
tank. The AMX302T includes a flexible metal connector
suitable for water heaters with an 11-in. spacing.