manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Rielta
  6. •
  7. Security Sensor
  8. •
  9. Rielta PYRONE-SH User manual

Rielta PYRONE-SH User manual

1 General Information
Passive infrared detector «Pyrone-SH» (hereinafter, the Detector)
is designed for detecting intrusion into the protected closed area
of a room through door and window openings, for generating and
transmitting alarm messages by the relay contacts opening. The
Detector is resistant to small animals movement, electromagnetic
interference and ambient light.
2 Features
- Dual-element pyrodetector.
- «Vertical curtain» detection zone.
- Microprocessor-based signal processing.
- Mounting height up to 5 m.
- Possibility of LED indication disabling.
- The Detector base has four planes for mounting, providing
possibility of the Detector installation in standard manner above the
window opening, as well as directly in the corners of window and door
openings. The Detector can be installed without swivel bracket on the
wall, ceiling or in the opening corner.
- High immunity to electromagnetic interference.
3 Specifications
Table 1
Parameter Value
Installation height, m, max 5
Alarm message duration, sec, not less 2
Power supply, V, DC 8 … 30
Consumption current, mA, not more 15
Operating temperature, °С minus 30 … 50
Relative humidity under 25 °С without water
condensation, %, up to 95
Detection zone type vertical curtain
Ambient class
Boreal Climate (background
temperature 15 - 35 оС,
relative humidity 25 - 75 %,
air-pressure 86-106 kPa)
IP rating IP41
Dimensions, mm, max 80 х 47 х 40
Weight, g, not more 60
The Detector is designed to operate continuously around the clock.
The Detector interference protection provides absence of false
alarms under the following conditions:
- background illumination differential;
- convective air flows;
- slow background temperature changing;
- voltage impulses in power-supply circuit;
- electrostatic discharge;
- electromagnetic fields in FM band.
The Detector generates Alarm message under human movement
within the detection zone limits transversally it’s side border at a speed
range 0.3 – 3 m/sec for the distance of 3 m.
The Detector is resistant to:
а) transport jolting with the acceleration 30 m/sec2 with impact
frequency from 10 to 120 impacts/sec or 15000 impacts with the
same acceleration;
b) the ambient temperature minus 50 … +50 °С;
c) relative air humidity (95 ± 3) % at the ambient temperature +35 °С.
After transportation under the conditions different to exploitation
conditions, the Detector shall be ready to operate after a maximum
of six hours.
Average time between failures is not less than 60 000 hours.
Average service life is 8 years.
Figure 1
7 Detection Zone Pattern
4 Scope of Delivery
Each Detector unit package contains the items listed in Table 2.
Table 2
Name QNT
Passive infrared detector «Pyrone-SH»
Passive infrared detector «Pyrone-SH». Installation Guide
1 pc.
1 copy
5 LED Indication
Table 3
Mode LED Indicator
ON OFF
Warm-up time after energizing Not more than
40 sec -
Message indication Alarm (for 3 sec) Norm
LED indicator is used for the Detector state displaying. For LED
indication disabling, remove «IND» jumper. Set up the jumper on one
of the aligning plug for the further usage during testing.
6 Choosing an Installation Place for the Detector
The Detector is designed fir using in closed premises (shops, offices,
museums, flats, etc.). When choosing locations for the Detector
installation, it is advisable to take note of the fact that the detection
zone may be limited by non-transparent objects (curtains, curtain
holders, door trims, etc), as well as glass partitions. There must be no
air conditioners, space heaters or heating radiators in the Detector’s
detection zone. Maximum installation height of the Detector is 5 m.
Alarm loop wiring should be conveyed far enough from electrical
power cables.
The Detector installation variants are shown in Figure 1.
a)
5 m
11о
6о
b)
10 m
90о
PASSIVE INFRARED DETECTOR
«PYRONE-SH»
Installation Guide
8 m
6 m
Till 5 m
Figure 2
8 Installing the Detector
Push the back wall of the Detector base (Figure 3), press the
cover edges by the second hand fingers in the places shown in
Figure 4 and put off the Detector cover.
Figure 4Figure 3
Insert a flat screwdriver into the slot between PCB and side wall of
the base, push the wall of the base and draw out the PCB (Figure 5).
Figure 8
9 Functional Testing
Test the detection zone (Figure 2) as follows:
- Set up the «IND» jumper (LED indicator is ON);
- Energize the Detector and wait for 1 min;
- Start walking through the detection zone at a speed rate
0.5 – 1 m/sec. When two zone lines are crossed, the Detector transmits
an alarm message (LED indicator is switched on, relay contacts are
opened).
- Cross the detection zone on the other side and define it’s other
border. When there is no motion in the detection zone, alarm messages
should not be generated.
If the detection zone is limited by non-transparent objects (curtains,
curtain holders, door trims, etc), it is necessary to change it’s location.
To correct detection zone location, the swivel bracket can be used
(supplied optionally).
After repeated detection zone alignment, install «IND» jumper to the
mode required for chosen protection tactics.
ATTENTION! The Detector must be checked at least annually in
order to test it’s performance.
Fasten the base on the chosen place.
Install the PCB to the base and latch it from both sides.
Fulfill connections in accordance with designation on the PCB
(Figure 7).
10 Storage and Transportation
The Detectors in their original packing may be shipped by any
transport means in covered vehicles (in railway, cars, trucks, sealed
heated compartments of aircraft, ship cargo holds, etc). The storage
room should be free from current-conducting dust, acid vapors, alkali
and gases that cause corrosion and destroy insulation.
11 Manufacturer’s Guarantees
The Manufacturer guarantees conformity of the Detector to it’s
Technical Specifications if conditions of transportation, storage,
assembling and operation are observed. The guaranteed storage
period is 63 months since the date of manufacturing the Detector.
The guaranteed period of operation is 60 months since the date of
commissioning within the storage period guaranteed.
The Detectors that are found to non-conforming to it’s Technical
Requirements shall be repaired by the Manufacturer, provided the
installation and operation rules have been complied with.
12 Acceptance and Packing Certificate
Wireless passive infrared detector «Pyrone-SH»
batch No ___________________
manufactured in accordance with current technical documentation
is classified as fit for operation and is packed by «RIELTA» JSC.
Person responsible for acceptance and packing
QC representative_________________ __________________.
Date, month, year
Figure 7
Put on the Detector cover (Figure 8).
Depending on chosen place of the Detector installation, determine
the sides of the Detector for its mounting. After it remove port plugs
for the Detector mounting and wire installation.
Run the wires through the openings for wire installation. Leave several
centimeters of the wire for connection to terminals.
Figure 5 Figure 6
+12V-
To the CP
loops
Power
supply
AL
«RIELTA» JSC, www.rielta.ru,
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],
Tel./fax. +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected]
Made in Russia
Rev. 4 of 24.05.17
№00316

Other Rielta Security Sensor manuals

Rielta FOTON-15B User manual

Rielta

Rielta FOTON-15B User manual

Rielta PYRONE-SH2-RK User manual

Rielta

Rielta PYRONE-SH2-RK User manual

Rielta FOTON-16A User manual

Rielta

Rielta FOTON-16A User manual

Rielta STEKLO-3RK User manual

Rielta

Rielta STEKLO-3RK User manual

Rielta UDAR User manual

Rielta

Rielta UDAR User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta ZVON-1 User manual

Rielta

Rielta ZVON-1 User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta PYRONE-SH User manual

Rielta

Rielta PYRONE-SH User manual

Rielta Pyrone-7 User manual

Rielta

Rielta Pyrone-7 User manual

Rielta Pyrone-4RK User manual

Rielta

Rielta Pyrone-4RK User manual

Rielta PYRONE-5 User manual

Rielta

Rielta PYRONE-5 User manual

Rielta STZ-RK User manual

Rielta

Rielta STZ-RK User manual

Rielta FOTON-SH User manual

Rielta

Rielta FOTON-SH User manual

Rielta PYRONE-8B-RK User manual

Rielta

Rielta PYRONE-8B-RK User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta chrana ORLAN-SH User manual

Rielta

Rielta chrana ORLAN-SH User manual

Rielta FOTON-SH1 User manual

Rielta

Rielta FOTON-SH1 User manual

Rielta FOTON-10M User manual

Rielta

Rielta FOTON-10M User manual

Rielta CELSIUS-RK User manual

Rielta

Rielta CELSIUS-RK User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta Pyrone-7i User manual

Rielta

Rielta Pyrone-7i User manual

Rielta GRAN-RK User manual

Rielta

Rielta GRAN-RK User manual

Rielta Ladoga MK-RK version 2 User manual

Rielta

Rielta Ladoga MK-RK version 2 User manual

Popular Security Sensor manuals by other brands

Niko SERVODAN user manual

Niko

Niko SERVODAN user manual

iRay Technology Luna1012X user manual

iRay Technology

iRay Technology Luna1012X user manual

DSC MAXSYS PC4400 installation guide

DSC

DSC MAXSYS PC4400 installation guide

Dalsa Rad-icon 1520 user manual

Dalsa

Dalsa Rad-icon 1520 user manual

Jula 400-235 operating instructions

Jula

Jula 400-235 operating instructions

brennenstuhl PIR 240 IP44 V2 Directions for use

brennenstuhl

brennenstuhl PIR 240 IP44 V2 Directions for use

Notch Sentinel Arborist Harness manual

Notch

Notch Sentinel Arborist Harness manual

schmersal BNS 300-01ZG operating instructions

schmersal

schmersal BNS 300-01ZG operating instructions

Aritech 700 series Installation sheet

Aritech

Aritech 700 series Installation sheet

ENFORCER KX25LR-WE manual

ENFORCER

ENFORCER KX25LR-WE manual

BuckEye Cam X80 user manual

BuckEye Cam

BuckEye Cam X80 user manual

DURRIDGE RAD7 user manual

DURRIDGE

DURRIDGE RAD7 user manual

Tyco MX-862 installation instructions

Tyco

Tyco MX-862 installation instructions

ITALIANA SENSORI 8057-ISR043 Installation, operation and maintenance manual

ITALIANA SENSORI

ITALIANA SENSORI 8057-ISR043 Installation, operation and maintenance manual

Argo WALLNER DL-07 manual

Argo

Argo WALLNER DL-07 manual

Me BELL-577 TX instruction manual

Me

Me BELL-577 TX instruction manual

Mustang Survival ELITE INFLATABLE PFD MD5153 owner's manual

Mustang Survival

Mustang Survival ELITE INFLATABLE PFD MD5153 owner's manual

Orno OR-CR-220 Operation and installation instruction

Orno

Orno OR-CR-220 Operation and installation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.