manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Risco
  6. •
  7. Security Sensor
  8. •
  9. Risco iWAVE T95 User manual

Risco iWAVE T95 User manual

x 1 x 3
2.2m-2.5m
(7'-8')
www.riscogroup.com
www.riscogroup.co.uk
www.riscogroup.fr
www.riscogroup.it
www.riscogroup.com/dutch
www.riscogroup.es
www.riscogroup.com/por
www.riscogroup.com/cn
< 36kg (80lb)
x 2
T
12
3A 45
6
-10°C > 40°C
(14°F > 104°F)
De detector in het systeem registreren
De iWAVE moet zichzelf bij de systeemontvanger identificeren. Dit kan
worden gedaan door het digitale serienummer 11 van de detector in het
systeem of met RF-modus te typen. Om de detectors met het
serienummer te registreren, moet u de installatiehandleiding van het
systeem raadplegen.
Met RF-communicatie registreren:
1.Stel de ontvanger in op de modus Leren
2.Plaats de accu’s en druk op gedurende minstens 3 seconden op de
sabotageschakelaar. De iWAVE verzendt een bericht SCHRIJVEN. Een
succesvol leren wordt door een bevestigingsbericht aangegeven, welke de
toewijzing van de detector in het systeem aangeeft.
IT Registrare il rilevatore nel sistema
iWAVE deve essere identificato dal ricevitore del sistema. Inserire pertanto il
numero di serie a 11 cifre del rilevatore nel sistema o utilizzare la modalità RF. Per
registrare il rilevatore utilizzando il numero di serie, fare riferimento al manuale di
installazione Agility.
Acquisizione tramite comunicazione RF
1.Impostare il ricevitore in modalità di apprendimento.
2.Inserire le batterie e premere l’interruttore tamper per almeno 3 secondi. iWAVE
invierà un messaggio WRITE. Il corretto apprendimento viene confermato da un
messaggio indicante l’allocazione del rilevatore nel sistema.
SP Registro del detector en el sistema
El iWAVE debe identificarse en el receptor del sistema. Esto puede hacerse
escribiendo en el sistema el número de serie de 11 dígitos del detector, o bien
usando el modo RF (Radio Frecuencia). Para registrar el detector usando el número
de serie, consulte el manual de instalación de Agility.
Alta del detector usando la comunicación RF
1. Ponga el receptor en modo Aprendizaje.
2. Inserte las pilas y pulse el interruptor del tamper durante al menos 3 segundos. El
iWAVE enviará un mensaje de Escritura. Si se ha dado de alta correctamente, se
oirá un mensaje de confirmación indicando la asignación del detector en el sistema.
FR Enregistrement du détecteur dans le système
Le modèle iWAVE doit être identifié par le système récepteur. Ceci peut être fait en
entrant les 11 chiffres du numéro de série du détecteur dans le système ou en
employant le mode RF. Pour enregistrer le détecteur en utilisant le numéro de
série, consultez le manuel d'installation de l'Agility.
Utilisation de la communication RF pour l'inscription
1.Réglez le récepteur en mode d’apprentissage
2.Insérez les batteries et appuyez sur le commutateur du dispositif anti-sabotage
durant au moins 3 secondes. Le iWAVE enverra un message ECRIT. Un message
de confirmation indiquant que l’inscription du détecteur dans le système a réussi
apparaîtra.
PR Registrando o detector no sistema
O iWAVE deve identificar-se ao receptor do sistema. Isto pode ser executado ao
digitar o número de série de 11 dígitos do detector no sistema ou utilizando o modo
de rádio freqüência. Para registrar o detector utilizando o número de série, consulte
o manual de instalação da Agility
Inscrição através de comunicação de rádio freqüência
1.Configure o receptor para o modo "Learn".
2.Introduza as pilhas e pressione o interruptor do tamper por pelo menos 3
segundos. O iWAVE enviará uma mensagem WRITE. Um aprendizado bem
sucedido será indicado por uma mensagem de confirmação que indica a atribuição
do detector no sistema.
EN Registering the Detector into the system
The iWAVE must identify itself to the system receiver. This can be done by typing
the 11 digit serial number of the detector into the system or using RF mode. To
register the detector using the serial number refer to the Agility installation manual.
Enrolling using RF communication
1.Set the receiver to Learn mode.
2.Insert the batteries and press the tamper switch for at least 3 seconds. The
iWAVE will send a WRITE message. A successful learning will be indicated by a
confirmation message that indicates the detector allocation in the system.
NL
PIR 868/433MHz
Model: iWAVE T95
PIR & PIR Pet Detectors
3
Attenzione: Pericolo di esplosione in caso di utilizzo di un tipo di batterie non adeguato. Smaltire le
batterie secondo la normativa vigente.
IT
SP
PR Cuidado: Pode ocorrer o risco de explosão caso substituir as pilhas por outras de tipo indevido. É
necessário desfazer-se daspilhas usadas de acordo com os regulamentos locais.
Advertencia: Si la batería se sustituye por un tipo incorrecto, hay riesgo de explosión. Deshágase de las
baterías usadas según las regulaciones locales
Let op: Als de accu met een verkeerd type wordt vervangen, onstaat de kans op explosie. Gebruikte
accu's moeten volgens de lokale reguleringen worden
NL
Mise en garde : risque d'explosion si la pile est remplacée par un type incorrect.
Débarrassez-vous des batteries usagées en accord avec les règlementations locales.
FR
Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according
to local regulations.
EN
PIR Pet 868/433MHz
Model: iWAVE T95P
O
1234
ON
1
2
3
4
SW1 Mode
Sensitivity
Operation
Supervision
LED
Function
Modo
Sensibilidad
Funciona-
miento
Supervisión
LED
Función
Modo
Sensibilita’
Modo
operativo
Supervisione
LED
Funzione
EN IT SP
Mode
Sensibilité
Operation
Surveillance
LED
Fonction
FR
Modalidade
Sensibilidade
Operação
Monitoração
LED
Função
PR
7 9
67.5mm
(2.6")
56mm
(2.2")
132mm
(5.1")
CR 123, 3V Lithium
-10°C > 40°C
(14°F > 104°F)
PIR: 9 A standby
Pet: 13 A standby
T15 min.
65 min.
= 3 Y Typical = 5 Y Typical
2
3
1
45
6
7
A
(Default)
FCC part 15 statement and warnings
(Models: iWAVE T95 and iWAVE T95P)
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and
receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician
for help.
FCC ID: JE4RWT90X433
868.65MHz / 433.92MHz
© RISCO Group 12/2009 5IN1088 C
O
N
A B C
Normal
2.5 min.
A
ON
High
Walk
Test
65 min.
ON
OFF
Low
Normal
2.5min
15 min.
OFF
ON
Alta
Prova
Movimento
65 min.
ON
OFF
Bassa
Normale
2.5min
15 min.
OFF
ON
Alta
Prueba de
Detección
65 min.
ON
OFF
Baja
Normal
2,5min.
15 min.
OFF
ON
Elevé
Test de
passage
65 min.
ON
OFF
Faible
Normal
2.5min
15 min.
OFF
ON
Alta
Teste de
Caminhada
65 min.
ON
OFF
Baixa
Normal
2.5min
15 min.
OFF
O
1234
ON
11
8
ft m PIR Pet - TOP VIEW
0
10
5
20
15
25
1
2
3
4
5
6
7
8
0
10
5
20
15
30
25
1
2
3
4
5
6
7
8
9
01052015 3025 4035
1234567891011120
12A
ft m
ft
m
123 45678 9101112
1
2
0
3
01052015 3025 4035
0
10
5
SIDE VIEW
12
ft.
1 2 3 4 5 6 7 8 9 101112131415
1
2
0
3
01052015 3025 4035 5045
0
10
5
PIR - SIDE VIEW
m
m
ft
ft
m
ft
0
1052015 3025 4035 5045
123456789101112131415
0
0
10
5
20
15
30
25
1
2
3
4
5
6
7
8
9
0
10
5
20
15
30
25
1
2
3
4
5
6
7
8
9
PIR - TOP VIEW
m
Poland
Tel: +48-22-500-28-40
[email protected]
Israel
Tel: +972-3963-7777
[email protected]m
United Kingdom
Tel: +44-161-655-5500
technical@riscogroup.co.uk
Italy
Tel: +39-02-66590054
[email protected]
Spain
Tel: +34-91-490-2133
[email protected]
France
Tel: +33-164-73-28-50
[email protected]
Belgium
Tel: +32-2522 7622
[email protected]om
USA
Tel: +1-631-719-4400
support-usa@riscogroup.com
Brazil
Tel: +1-866-969-5111
support-br@riscogroup.com
China
Tel: +86-21-52-39-0066
[email protected]om
0-20Min
5
BC
O
1234
ON
10
These detection pattern is only assured and approved according to EN50131 in High
sensitivity settings. For low sensitivity setting, the actual detection pattern must be assured
during the installation
EN50131-1, EN50131-2-2 Grade 2 ,EN50130-5 Environmental Class II,
EN50131-6: Type C EN50131–5-3 Grade 2
APPROVALS
(Models: iWAVE T95 and iWAVE T95P)
EN
IT
SP
FR
PR
Questo metodo di rilevazione è assicurato e approvato in accordo con la norma EN50131
solo quando il rilevatore è in ALTA SENSIBILITA’. Per il settaggio in bassa sensibilità, questo
metodo di rilevazione è assicurato solamente durante l’installazione.
Estos patrones de detección sólo están garantizados y aprobados conforme a EN50131 en la
configuración de Alta sensibilidad. Para la configuración de Baja sensibilidad, el patrón exacto
de detección debe asegurarse durante la instalación.
Cette couverture de détection n’est assurée et approuvée selon la norme EN50131 qu’avec
un réglage en Haute Sensibilité. Pour un réglage avec une Faible Sensibilité, la couverture de
détection devra être vérifiée au cours de l’installation.
Este padrão de detecção só é garantido e aprovado de acordo com a EN50131 com o
ajuste para alta sensibilidade. Para ajuste de baixa sensibilidade, o padrão real de
detecção deve ser certificado durante a instalação.
NL Deze detectie patroon, in lijn met de EN 50131 norm, zijn alleen geldig als de parameters op
het maximum gevoeligheid niveau afgesteld zijn. Voor een lager detectie niveau, de detectie
patroon zou op het moment van de installatie moeten afgesteld worden.
Contacting RISCO Group
RISCO Group is committed to customer service and product support. You can contact us through our website www.riscogroup.com or as follows:
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of
production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot
guarantee the performance of the security system which uses this product. Seller's obligation and liability under this warranty is expressly limited to repairing and replacing, at Seller's
option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty
of merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty,
expressed or implied, or upon any other basis of liability whatsoever. Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any
liability for direct, indirect, or consequential damages or delay. Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any
personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection. Buyer understands that a properly
installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that such event will not occur or that there will
be no personal injury or property loss as a result thereof. Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product
fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or
origin, seller's maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or representative of
Seller is authorized to change this warranty in any way or grant any other warranty. WARNING: This product should be tested at least once a week.

This manual suits for next models

1

Other Risco Security Sensor manuals

Risco RK350DT User manual

Risco

Risco RK350DT User manual

Risco WatchOUT User manual

Risco

Risco WatchOUT User manual

Risco Beyond Wireless DT User manual

Risco

Risco Beyond Wireless DT User manual

Risco RWX106BA User manual

Risco

Risco RWX106BA User manual

Risco iWISE Wireless RWT92 User manual

Risco

Risco iWISE Wireless RWT92 User manual

Risco iREX User manual

Risco

Risco iREX User manual

Risco Bware RWX515PR User manual

Risco

Risco Bware RWX515PR User manual

Risco RWT6FW43300A User manual

Risco

Risco RWT6FW43300A User manual

Risco WatchIN RK325DT User manual

Risco

Risco WatchIN RK325DT User manual

Risco RK66S User manual

Risco

Risco RK66S User manual

Risco iWAWE RWX95P User manual

Risco

Risco iWAWE RWX95P User manual

Risco BWare BUS DT AM G3 User manual

Risco

Risco BWare BUS DT AM G3 User manual

Risco WatchU User manual

Risco

Risco WatchU User manual

Risco ShockTec Plus Grade 3 User manual

Risco

Risco ShockTec Plus Grade 3 User manual

Risco iWISE RK815DTG3 User manual

Risco

Risco iWISE RK815DTG3 User manual

Risco WarchIN RK325DT User manual

Risco

Risco WarchIN RK325DT User manual

Risco RWT6F User manual

Risco

Risco RWT6F User manual

Risco Wirless WatchOUT RWX312PR800C User manual

Risco

Risco Wirless WatchOUT RWX312PR800C User manual

Risco iWave RWX95 User manual

Risco

Risco iWave RWX95 User manual

Risco Digi-415DT User manual

Risco

Risco Digi-415DT User manual

Risco Wireless ViTRON User manual

Risco

Risco Wireless ViTRON User manual

Risco WL T6S User manual

Risco

Risco WL T6S User manual

Risco RK6F User manual

Risco

Risco RK6F User manual

Risco EL-5835D User manual

Risco

Risco EL-5835D User manual

Popular Security Sensor manuals by other brands

ABS ABS-Lock X-H-4 Series installation manual

ABS

ABS ABS-Lock X-H-4 Series installation manual

Linde G-TECTA 4G operating manual

Linde

Linde G-TECTA 4G operating manual

Renkforce 1530623 operating instructions

Renkforce

Renkforce 1530623 operating instructions

MSA ALTAIR CO operating manual

MSA

MSA ALTAIR CO operating manual

BW Technologies GasAlertMax XT II Technical reference guide

BW Technologies

BW Technologies GasAlertMax XT II Technical reference guide

PCB Load & Torque 4115K-13A Installation and operating manual

PCB

PCB Load & Torque 4115K-13A Installation and operating manual

Bosch 520 Series Operation guide

Bosch

Bosch 520 Series Operation guide

Shield D-A410 quick guide

Shield

Shield D-A410 quick guide

Mace 80200 manual

Mace

Mace 80200 manual

Honeywell V-Plex IS3050A-SN Quick installation guide

Honeywell

Honeywell V-Plex IS3050A-SN Quick installation guide

SGB VLR Series Documentation

SGB

SGB VLR Series Documentation

REED R5044 instruction manual

REED

REED R5044 instruction manual

jablotron LARGO JS-20 manual

jablotron

jablotron LARGO JS-20 manual

Plaisio a-connect QCD02 manual

Plaisio

Plaisio a-connect QCD02 manual

Omron K8AC-H Series manual

Omron

Omron K8AC-H Series manual

AJAX MotionProtect quick start guide

AJAX

AJAX MotionProtect quick start guide

AQUALEAK EMS-01 instruction manual

AQUALEAK

AQUALEAK EMS-01 instruction manual

jablotron JA-60V installation manual

jablotron

jablotron JA-60V installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.