Saferhomee HB-2050G User manual

Manual Of Networking Alarm Panel
HB-2050G
HB-4040G
HB-5050G
网络报警主机使用说明
1
1.HB-2050G
网络报警主机使用说明
2
HB-2050G Connections of cables:
SIM Card Slot: Only 2G SIM Card is available(Mini SIM)
Power Interface:DC15V/1.5A
Output Interface:DC12V/0.5A(Linkage other devices--Siren and etc)
Set Button: Restore to the factory default
Technical Parameters:
Working Voltage
DC 15V/1.5A
Wireless Frequency
434.6MHz FSK
GSM Frequency
900/1800/1900/2100 MHz
Dimension
103x110x49(mm)
网络报警主机使用说明
3
2.HB-4040G
网络报警主机使用说明
4
HB-4040G Connections of cables:
网络报警主机使用说明
5
SIM Card Slot: Only 2G SIM Card is available(Mini SIM)
Power Interface:DC15V/1.5A
Output Interface:DC12V/0.5A(Linkage other devices--Siren and etc)
Set Button: Restore to the factory default
Technical Parameters:
Working Voltage
DC 15V/1.5A
Backup Battery
4×3.2V LiFePO4 Battery
Wireless Frequency
434.6MHz FSK
GSM Frequency
900/1800/1900/2100 MHz
Dimension
163x146x16(mm)
3.HB-5050G
网络报警主机使用说明
6
HB-5050G Connections of cables
网络报警主机使用说明
7
HB-5050R Connections of cables
Outputs Jumpers(Disable):used to control the warning board status
+12: If AC powered,work normally;If DC powered,work abnormally
网络报警主机使用说明
8
OUT: Alarming Mode,the warning board will light; Arm or Disarm
Mode,the warning board will blink;
Warning Board Interface:DC12V/0.5A outputs
Siren Interface:DC12V/0.5A outputs
Power Interface:DC15V/1.5A
SIM Card Slot: Only 2G SIM Card is available(Mini SIM)
Set Button: Restore to the factory default
Technical Parameters:
Working Voltage
DC 15V/1.5A
Backup Battery
12V/1.3Ah
Wireless Frequency
434.6MHz FSK
GSM Frequency
900/1800/1900/2100 MHz
Dimension
165x175x62(mm)
4.Instructions
LCD Display:
-01/01 (01Blinking)
On Setting Mode
-F0
Restored to factory default
-F6
Connected to Server Success
No Display
Static working status,alarm panel has been
connected the detectors or remote controls
-XX (-Blinking)
learning detector status(XX:01…99 zone number)
_XX
Learned detector success(XX:01…99 zone number)
-XX
Alarm(XX:01…99 zone number)
-0X (-Blinking)
learning remotes status(X: 1-4 zone number)
_0X
Learned remotes success(X: 1-4 zone number)
-F5
Emergency Alarm(SOS)
-F7
Connect to server failure
网络报警主机使用说明
9
-F2
Deleted account information success
-F8
SIM card faults
HXX
GPRS Signal less than 13(XX: 00-13)
-F1
Tamper
Indicator lights:
Red: Arm Status
White(2050G)/Yellow(4040G)/Green(5050G):Disarm Status
Delete Account Information:Press the “Setting Button”Once,LCD
Display”-01”(01 Blinking),and then hold the “Setting Button”for
5 seconds , Release the “setting button”when the LCD
Display”-F2”;
Restore to factory default:Press the “Setting Button”Once,LCD
Display”-01”(01 Blinking),and then hold the “Setting Button”for
10 seconds , Release the “setting button”when the LCD
Display”-F0”;
5. APP Operation Manuals
5.1 Phone Configuration
Smart Phone
Above Android(4.0) Operating System
≥2G RAM
≥2G Storage Memory
5.2 Phone Setup→
Setting →Permissions →Saferhomee
Write and delete SMS messages →Accept
Read SMS messages →Accept
Change mobile data connectivity →Accept
网络报警主机使用说明
10
Change WLAN connectivity →Accept
Setting →Permissions →Autostart
Set Saferhomee can autostart
5.3 App Interface(Home):
网络报警主机使用说明
11
All Arm: On receiving all the alarm information mode
Disarm: On not receiving normal alarm information mode
Part Arm: Disable
Mute: Make the app silence when alarm
SOS:Emergency Help
5.4 Account Setup(Account)
Press”Account”--- enter password:123456
网络报警主机使用说明
12
SIM Card of the alarm panel supports SMS?Please choose Yes/No
according to functions of the SIM Card(If Yes,please fill the SIM card
number)
SIM Card Number:The SIM Card number of the alarm panel
Alarm Panel ID:Fill the 15-digits Serial Number/Scan the OR Code
Phone Number:The SIM Card number of the phone installed the App
Setup Password:Original password is 123456(Please reset in”Setup”)
Final,Press”Submit “
5.5 Alarm Panel Setup(Setup)
网络报警主机使用说明
13
Phone Number
网络报警主机使用说明
14
Total 4 groups phone number can be set
Standard Alarm Center SMS Number:Disable
Transfer Alarm Center SMS Number:Disable
Detector
网络报警主机使用说明
15
Select the zone number(1--99)
Select the zone type(Normal,Emergency,Fire,Help,Gas,Water)
Fill the Notes and save the notes
Press”Match “----and then trigger the detector once
SMS Mode
网络报警主机使用说明
16
Factory Default is Enable;If select the “Disable”,the alarm panel and
the app will not keep communication if on offline status..
Remote Control
网络报警主机使用说明
17
Select the remote control(1#--4#)
Press “+” to add the remote control
Press “-” to delete the remote control
Timing Time
网络报警主机使用说明
18
Query Timing Time: Querythe last timing time
2 groups of arm/disarm time can be set...press”√”to confirm.
Password
网络报警主机使用说明
19
Note:The password should be 6-digits
Ademco ID &Server’s Domain Address are used to communicate
with the SAFERHOMEE Alarm Software...(Disable)
Time(Disable)

This manual suits for next models

2

Other Saferhomee Security System manuals

Saferhomee HB-BJQ-560A User manual

Saferhomee

Saferhomee HB-BJQ-560A User manual

Saferhomee HB-5050G User manual

Saferhomee

Saferhomee HB-5050G User manual

Saferhomee HB-4040S User manual

Saferhomee

Saferhomee HB-4040S User manual

Saferhomee HTZSAFE 806A User manual

Saferhomee

Saferhomee HTZSAFE 806A User manual

Popular Security System manuals by other brands

ADT SAFEWATCH PRO user manual

ADT

ADT SAFEWATCH PRO user manual

OOSSXX 6-in-1 DVR & DVR Security System owner's manual

OOSSXX

OOSSXX 6-in-1 DVR & DVR Security System owner's manual

Velleman HAM202 user manual

Velleman

Velleman HAM202 user manual

Honeywell ADEMCO LYNXR-ISIA Installation and setup guide

Honeywell

Honeywell ADEMCO LYNXR-ISIA Installation and setup guide

DVS AXIO user guide

DVS

DVS AXIO user guide

Digital Monitoring Products XT30 Series user guide

Digital Monitoring Products

Digital Monitoring Products XT30 Series user guide

Honeywell 3516 manual 

Honeywell

Honeywell 3516 manual 

Clover OW1202 Specifications

Clover

Clover OW1202 Specifications

Makim D20 user manual

Makim

Makim D20 user manual

HAI OMNI II installation manual

HAI

HAI OMNI II installation manual

Guardian ROVA Quick start user guide

Guardian

Guardian ROVA Quick start user guide

Dahua DSS7016D-S2 quick start guide

Dahua

Dahua DSS7016D-S2 quick start guide

Rushworks Remo 48 user guide

Rushworks

Rushworks Remo 48 user guide

PSA Supa8 user manual

PSA

PSA Supa8 user manual

Cooper Security i-On 40 Administrator's and user guide

Cooper Security

Cooper Security i-On 40 Administrator's and user guide

Hercules 10 Engineering manual

Hercules

Hercules 10 Engineering manual

LifeShield Cellular Primary Quick setup guide