1
1.HB-2050G
网络报警主机使用说明
2
HB-2050G Connections of cables:
SIM Card Slot: Only 2G SIM Card is available(Mini SIM)
Power Interface:DC15V/1.5A
Output Interface:DC12V/0.5A(Linkage other devices--Siren and etc)
Set Button: Restore to the factory default
Technical Parameters:
Working Voltage
DC 15V/1.5A
Wireless Frequency
434.6MHz FSK
GSM Frequency
900/1800/1900/2100 MHz
Dimension
103x110x49(mm)
网络报警主机使用说明
3
2.HB-4040G
网络报警主机使用说明
4
HB-4040G Connections of cables:
网络报警主机使用说明
5
SIM Card Slot: Only 2G SIM Card is available(Mini SIM)
Power Interface:DC15V/1.5A
Output Interface:DC12V/0.5A(Linkage other devices--Siren and etc)
Set Button: Restore to the factory default
Technical Parameters:
Working Voltage
DC 15V/1.5A
Backup Battery
4×3.2V LiFePO4 Battery
Wireless Frequency
434.6MHz FSK
GSM Frequency
900/1800/1900/2100 MHz
Dimension
163x146x16(mm)
3.HB-5050G
网络报警主机使用说明
6
HB-5050G Connections of cables
网络报警主机使用说明
7
HB-5050R Connections of cables
Outputs Jumpers(Disable):used to control the warning board status
+12: If AC powered,work normally;If DC powered,work abnormally
网络报警主机使用说明
8
OUT: Alarming Mode,the warning board will light; Arm or Disarm
Mode,the warning board will blink;
Warning Board Interface:DC12V/0.5A outputs
Siren Interface:DC12V/0.5A outputs
Power Interface:DC15V/1.5A
SIM Card Slot: Only 2G SIM Card is available(Mini SIM)
Set Button: Restore to the factory default
Technical Parameters:
Working Voltage
DC 15V/1.5A
Backup Battery
12V/1.3Ah
Wireless Frequency
434.6MHz FSK
GSM Frequency
900/1800/1900/2100 MHz
Dimension
165x175x62(mm)
4.Instructions
LCD Display:
-01/01 (01Blinking)
On Setting Mode
-F0
Restored to factory default
-F6
Connected to Server Success
No Display
Static working status,alarm panel has been
connected the detectors or remote controls
-XX (-Blinking)
learning detector status(XX:01…99 zone number)
_XX
Learned detector success(XX:01…99 zone number)
-XX
Alarm(XX:01…99 zone number)
-0X (-Blinking)
learning remotes status(X: 1-4 zone number)
_0X
Learned remotes success(X: 1-4 zone number)
-F5
Emergency Alarm(SOS)
-F7
Connect to server failure
网络报警主机使用说明
9
-F2
Deleted account information success
-F8
SIM card faults
HXX
GPRS Signal less than 13(XX: 00-13)
-F1
Tamper
Indicator lights:
Red: Arm Status
White(2050G)/Yellow(4040G)/Green(5050G):Disarm Status
Delete Account Information:Press the “Setting Button”Once,LCD
Display”-01”(01 Blinking),and then hold the “Setting Button”for
5 seconds , Release the “setting button”when the LCD
Display”-F2”;
Restore to factory default:Press the “Setting Button”Once,LCD
Display”-01”(01 Blinking),and then hold the “Setting Button”for
10 seconds , Release the “setting button”when the LCD
Display”-F0”;
5. APP Operation Manuals
5.1 Phone Configuration
Smart Phone
Above Android(4.0) Operating System
≥2G RAM
≥2G Storage Memory
5.2 Phone Setup→
Setting →Permissions →Saferhomee
Write and delete SMS messages →Accept
Read SMS messages →Accept
Change mobile data connectivity →Accept

This manual suits for next models

2

Other Saferhomee Security System manuals

Saferhomee HB-BJQ-560A User manual

Saferhomee

Saferhomee HB-BJQ-560A User manual

Saferhomee HB-4040S User manual

Saferhomee

Saferhomee HB-4040S User manual

Saferhomee HTZSAFE 806A User manual

Saferhomee

Saferhomee HTZSAFE 806A User manual

Saferhomee HB-5050G User manual

Saferhomee

Saferhomee HB-5050G User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.