ENGLISH-19
Main
menu
Sub
menu Function description
Setting value
Page Save location
Value Factory
default
2
1Temperature
Limit
Lower limit 8 ~ 30 °C (47 ~ 86 °F) 8 (47) 01
Wired remote controller
2Upper limit 8 ~ 30 °C (47 ~ 86 °F) 30 (86) 01
Wired remote controller
3Set Outing
Temperature
Cooling desire temperature on
outing function 25 ~ 30 °C (77 ~ 86 °F) 27 (81) 01
Wired remote controller
4Heating desire temperature on
outing function 16 ~ 22 °C (61 ~ 72 °F) 16 (61) 01
Wired remote controller
3
1Lock of all buttons 0-Unlock, 1-Lock 001
Wired remote controller
2Partial Button
Lock 1
Lock of operation ON/OFF button 0-Unlock, 1-Lock 001
Wired remote controller
Lock of temperature setting buttons 0-Unlock, 1-Lock 002
Wired remote controller
Lock of fan speed button 0-Unlock, 1-Lock 003
Wired remote controller
3Partial Button
Lock 2
Lock of ON/OFF timer function
button 0-Unlock, 1-Lock 001
Wired remote controller
Lock of Swing function button 0-Unlock, 1-Lock 002
Wired remote controller
Lock of Sleep function button 0-Unlock, 1-Lock 003
Wired remote controller
Lock of Quiet function button 0-Unlock, 1-Lock 004
Wired remote controller
Lock of Outing function button 0-Unlock, 1-Lock 005
Wired remote controller
Lock of Lock function button 0-Unlock, 1-Lock 006
Wired remote controller
Lock of Wind-Free Cooling function 0-Unlock, 1-Lock 007
Wired remote controller
Lock of Long reach function 0-Unlock, 1-Lock 008
Wired remote controller
Lock of Clean function 0-Unlock, 1-Lock 009
Wired remote controller
4
Operation Mode
Partial Button
Lock
Lock of operation mode button 0-Unlock, 1-Lock 001
Wired remote controller
Hide of auto mode 0-Unlock, 1-Lock 002
Wired remote controller
Hide of cool mode 0-Unlock, 1-Lock 003
Wired remote controller
Hide of dry mode 0-Unlock, 1-Lock 004
Wired remote controller
Hide of fan mode 0-Unlock, 1-Lock 005
Wired remote controller
Hide of heat mode 0-Unlock, 1-Lock 006
Wired remote controller
6 1 Checking/setting of backlight time out 0~30 (Disuse in 0) 501
Wired remote controller
(1 time use)
7
1
User Setting
Function
Resetting lter cleaning alarm 0-No reset, 1-Reset 001
Wired remote controller
2Use of S-Plasma Ion 0-Disuse, 1-Use 001
Wired remote controller
3Use display of current temperature 0-Disuse, 1-Use 101
Wired remote controller
4Use of button melody 0-Disuse, 1-Use 101
Wired remote controller
5Use of IR receiver for wireless remote
controller 1)* 0-Disuse, 1-Use 001
Wired remote controller
6Use of Standby Mode 0-Disuse, 1-Use 101
Wired remote controller
7Use of Indoor Unit Lighting ON/OFF 0-Disuse, 1-Use 101
Wired remote controller
8 1 Setting/Checking Easy Tuning -2 ~ +2 001
Wired remote controller
(1 time use)
0 1 Reset to default value of user setting mode
(except current time) 0-No reset, 1-Reset 001
Wired remote controller
(1 time use)
• will blink if you select a function that is not supported by the indoor unit.
NOTE
1)* In case of duct type indoor unit, you can use wireless remote controller using IR receiver of this wired remote controller
without "Display and receiver kit". Some functions may not be activated by the wireless remote controller.