manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. S&P
  6. •
  7. Fan
  8. •
  9. S&P PCD110 User manual

S&P PCD110 User manual

VENTILATION FAN
WARNING
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
Model: PCD110 PCD110H
CAUTION
CLEANING & MAINTENANCE
OPERATION
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the
motor with the exact service motor. The impeller should also be replaced.
WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switching
on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics,
crawl spaces, or garages
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater R40.
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
*The manual in electronic format can be download in our company web, or obtained from our dealer.
-
+-
+
1 2 3
1 2 3
Toggle switch
Power box
Low airflow
knob
Humidity sensor knob
(for model PCD110H)
80 90 110 120 90 110 120 140
1 2 31 2 31 2 31 2 31 2 31 2 31 2 31 2 3
6"
Switch
position
Duct
diameter
(inches)
Airflow
(CFM)
6"
6"
6"4"4"4"4"
80 90 110 120 90 110 120 140
1231231231231 2 31 2 3
1 2 31 2 3
6"
Switch
position
Duct
diameter
(inches)
Air deliver
(CFM)
6"
6"
6"4"4"4"4"
is the position of switch
Other airflow reference performance based on HVI Procedures
915, 916, and 920.
Factory setting: 110CFM ( )
HVI Certified performance based on HVI Procedures 915, 916,
and 920.
with 6" duct
The control box, located inside the fan housing, has three separate adjustments:
(1) The low airflow knob adjusts the lower airflow from 30CFM up to the air flow
rate of the high fan speed determined by the toggle switch setting.
(2) (a)The time delay knob is adjustable from 3 to 30 minutes and will switch the
fan to the low speed setting after motion is no longer detected in the room for
the set period of time(for model PCD110).
(b)The humidity sensor knob set user-adjustable setpoint(for model PCD110H).
(3) The toggle switch will adjust the upper fan speed setting from 80 to 120 CFM
using a 4" duct, or 90 to 140 CFM using a 6" duct.
Both 4" & 6" duct adaptors are included.
For model PCD110H
1) Fan run continuously at a low speed(adjustable by low airflow knob) and automatically boost up to high speed when either of these
conditions is detected: a)Humidity above a user-adjustable setpoint (50%-100% relative humidity). b) rapid to moderate (user-adjustable)
increases in humidity .After delay timer (20 minutes) returns fan to the default low speed.Humidity sensor description accroding to
“HUMIDITY SENSOR OPERATION” and“SENSITIVITY ADJUSTMENT”.
2) When the switch is turned on, the fan will run at high speed. When the switch is turned OFF, fan will continue to run at the certified airflow
rate until the delay timer (20 minutes) has elapsed,and then will automatically change to the user-adjustable airflow rate.
For model PCD110
To Turn Fan ON
Turn the switch I ON.(according to the following “CONNECT ELECTRICAL WIRING”)
• Fan will run at the certified airflow rate if the switch II is ON.
• Fan will run at the user-adjustable airflow rate if the switch II is OFF.
To Use Fan Time Delay Airflow Rate Change
1. Turn the switch I ON.
2. Turn the switch II ON - fan will run at the certified airflow rate.
3. When the switch II is turned OFF, fan will continue to run at the certified airflow
rate until the user-adjustable time delay has elapsed, and then will automatically
change to the user-adjustable airflow rate.
To Turn Fan OFF
Turn the switch I OFF
Timer delay knob
(for model PCD110)
or
Hold the housing so that it is in contact with the bottom of the joist. Attach
the housing with four (4) screws to the joist through the holes in each
mounting flange.
1. MOUNT HOUSING TO JOIST OR I-JOIST.
2. MOUNT WITH HANGER BARS
2a. Sliding hanger bars have been provided, which allow the housing to
be positioned accurately anywhere between the framing. The bars span
up to 24 in. and can be used on all types of framing: I-joist, standard joist,
and truss construction. Slide hanger bars onto housing and adjust as
needed to fit between framing.
PLAN THE INSTALLATION
TYPES OF TYPICAL INSTALLATIONS
1. Do not use in a cooking area.
2. Two ways to connect ductwork to a factory-shipped unit.
ASSEMBLY INSTRUCTIONS
1. Housing mounted to I-joists (Start at “ASSEMBLY INSTRUCTIONS 1”)
2. Housing mounted to joists (Start at “ASSEMBLY INSTRUCTIONS 1” )
3. Housing mounted to truss (Start at step “ASSEMBLY INSTRUCTIONS 2”)
2
OPERATION
ROOF CAP*
(with built-in
damper)
ROUND
DUCT* WALL CAP*
(with built-in
damper)
*Purchase
separately
POWER
CABLE*
INSULATION*
(Place around and
over Fan Housing.)
Seal gaps
around
Housing.
FAN
HOUSING
ROUND
ELBOW(S) *
Seal duct
joints with
tape.
Keep duct
runs short
HUMIDITY SENSOR OPERATION
The humidity-sensing fan uses a sophisticated humidity sensor that responds to: (a) rapid to moderate (user-adjustable) increases in
humidity or (b) humidity above a user-adjustable set-point (50%-100% relative humidity). Fan run continuously at a pre-set lower level (set by
Humidity sensor knob) and automatically boost up to certified airflow rate when environmental conditions change). If the fan continuously
responds to changing environmental conditions, “H” (means “humidity”) adjustment may be required. This figure is factory-set for about 75%
(Ambient temperature of 25℃).
SENSITIVITY ADJUSTMENT
The “H” has been factory set for most shower applications. However, if the fan is in a tub area or is being used for dampness control, the “H”
may need to be increased toward maximum “+”. If the control is responding too often to changing environmental conditions, movement toward
less “-” “H” may be required.
To adjust the “H”:
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked “H”.
3. Carefully rotate the “H” adjustment toward “+” or “-”.
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.
5. Repeat above steps if necessary.
When the temperature changes, humidity sensor values will have deviation.
HANGER
BAR
NAIL
2b. Extend the hanger bars to the width of the framing. Position the
ventilator with the hanger bar tabs wrapped around the bottom edge of
the framing, holding the ventilator in place.
Secure hanger bars to framing using one screw on each end of hanger bar.
Select a proper hole and secure the hanger bars together using flange
screws.
3. ATTACH DAMPER/DUCT CONNECTOR
Snap the damper/duct connector onto the fan housing. The connector
must be flush with the top of the housing, and the damper flap should
fall closed.
4. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector,
and run the ductwork to a roof or wall cap (not included). Using tape (not
included), secure all the ductwork connections so that they are air tight.
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
ASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS
CONNECT ELECTRICAL WIRING
SCREW
3
DUCT
UNIT
BLACK(BLK)
SWITCH BOX
SWITCH
120V AC LINE IN
GROUND (GRD)
BROWN(BRN)
WHITE (WHT)
WIRE PANEL
RECEPTACLE
Insulated flexible duct is recommended for the quietest possible installation.
If rigid duct is used, a short (1-3 feet) section of insulated flexible duct will
ensure quiet operation
FAN
BRN
BLK
SWITCH
UNIT
BLACK (BLK)
SWITCH BOX
SWITCH I
POWER SUPPLY
120V AC
GROUND (GRD)
WHITE (WHT)
FAN
RECEPTACLE
FAN
WIRE
PANEL
BRN
BLK
SWITCH I
SWITCH II
SWITCH II
BROWN (BRN)
For model PCD110H
For model PCD110
WARRANTY
INSTALL GRILLE
SERVICE PARTS
4
5
6
d
e
a
1
2
3
4
b
c
7
9
8
10
10
11
PART PART NAME Qty.
1
2
3
4
5
6
7
8
9
10
11
a
b
c
d
e
Housing
Damper / Duct Connector
Wiring plate
Screw
Blower Wheel
Wire Panel / Harness Assembly
Motor
1
2
1
1
1
1
1
1
1
4
1
4
4
1
4
1
Isolator
Motor Plate
Washer
Nut, Hex Lock
Grille Assembly (includes part 2 )
Grille Spring
Hanger Bar Kit
Screw
Power Box
* Blower Assembly includes part 6, 5, d, 4, c, b, a.
Replacement installation:
Remove the screw (part c), then take out the motor plate (part 4) from
the housing (part 9) by pushing down the rib in the plate while pulling
out on the side of the housing. Replace the broken parts.
WARNING: Before replacing, be sure to turn off power at power source.
S&P USA Ventilation Systems, LLC. & S&P Canada Ventilation Products, Inc. warrants to the original end user of its
products that our exhaust fans will be free from defects in materials and workmanship for a period of Five (5) years from
the date of original purchase. 6 years warranty for motor and 5 years warranty for the remaining fan parts. THERE ARE
NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED
WARRANTIES OF SUITABILITY FOR A PARTICULAR PURPOSE.
During this five year period, S&P will, at its option, repair returned products or parts, or provide replacement products or
parts, without charge, for any product or part which is found to be defective under normal use.
This warranty does not cover normal maintenance and service or any parts that have been subject to misuse, negligence,
accident, improper maintenance or repair, faulty installation or installation contrary to recommended installation instructions.
S&P’s obligation to repair or replace, at S&P’s option, shall be the purchaser’s sole and exclusive remedy under this
warranty. No labor or materials are covered by this warranty. S&P shall not be liable for incidental damages arising out of
or in connection with product use or performance.
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.
To qualify for warranty service, you must notify S&P at the address or telephone number stated below, provide the model
number and part identification, and describe the nature of any defect in product or part. You may be required to ship a
defective part to S&P. There will be no charge for shipping repaired or replacement parts from S&P to you if your address
is in the United States or Canada. At the time of requesting warranty service, you must present evidence of the original
purchase date.
Install ceiling material to complete the ceiling construction. Then, cut around
the fan housing.
To attach the grille assembly to the fan housing, pinch the grille springs on
the sides of the grille assembly, and position the grille into the housing with
the grille springs in the appropriate slots. Push the grille assembly towards
the ceiling to secure.
S&P Canada Ventilation Products, Inc.
5600 Ambler Drive Mississauga, ON L4W 2K9
P. 866-733-0233
F. 866-358-5346
www.solerpalaucanada.com
S&P USA Ventilation Systems,LLC.
6393 Powers Avenue Jacksonville, FL 32217
P. 904-731-4711
F. 904-731-8322
www.spvg-northamerica.com

This manual suits for next models

1

Other S&P Fan manuals

S&P HV-150 A User manual

S&P

S&P HV-150 A User manual

S&P KCTR Series User manual

S&P

S&P KCTR Series User manual

S&P PCD80XHP User manual

S&P

S&P PCD80XHP User manual

S&P AIRPUR-N User manual

S&P

S&P AIRPUR-N User manual

S&P ARTIC-405 CN GR User manual

S&P

S&P ARTIC-405 CN GR User manual

S&P PCLP80XP User manual

S&P

S&P PCLP80XP User manual

S&P RESPIRO 100 User manual

S&P

S&P RESPIRO 100 User manual

S&P JETLINE 100 User manual

S&P

S&P JETLINE 100 User manual

S&P MBE-R User manual

S&P

S&P MBE-R User manual

S&P EDM-200 Series User manual

S&P

S&P EDM-200 Series User manual

S&P EDM-100 Series User manual

S&P

S&P EDM-100 Series User manual

S&P METEOR NT User manual

S&P

S&P METEOR NT User manual

S&P HV-150 AE Manual

S&P

S&P HV-150 AE Manual

S&P Decor-100 Design User manual

S&P

S&P Decor-100 Design User manual

S&P Ventur DECOR-300 User manual

S&P

S&P Ventur DECOR-300 User manual

S&P PCDXP Series User manual

S&P

S&P PCDXP Series User manual

S&P TD SILENT User manual

S&P

S&P TD SILENT User manual

S&P TH MIXVENT Series User manual

S&P

S&P TH MIXVENT Series User manual

S&P Turbo-351N Instructions for use

S&P

S&P Turbo-351N Instructions for use

S&P MDX-ES24VK User manual

S&P

S&P MDX-ES24VK User manual

S&P PRF-150 User manual

S&P

S&P PRF-150 User manual

S&P ECOWATT HXBR User manual

S&P

S&P ECOWATT HXBR User manual

S&P RED User manual

S&P

S&P RED User manual

S&P SILENT-200 DESIGN Manual

S&P

S&P SILENT-200 DESIGN Manual

Popular Fan manuals by other brands

Craftmade DCF52 5C1W Series installation guide

Craftmade

Craftmade DCF52 5C1W Series installation guide

Midea FSD35-19R owner's manual

Midea

Midea FSD35-19R owner's manual

Ozeri Brezza 360 Instruction manual and warranty

Ozeri

Ozeri Brezza 360 Instruction manual and warranty

Faro Hydra installation guide

Faro

Faro Hydra installation guide

HOFFLIGHTS PASCUA installation manual

HOFFLIGHTS

HOFFLIGHTS PASCUA installation manual

EDM 33939 instructions

EDM

EDM 33939 instructions

Aspira AFM User instructions

Aspira

Aspira AFM User instructions

Fanelite KYT-30B user manual

Fanelite

Fanelite KYT-30B user manual

Brandson 301492 user manual

Brandson

Brandson 301492 user manual

Progress Lighting AirPro P250006 installation manual

Progress Lighting

Progress Lighting AirPro P250006 installation manual

Hunter Highbury Owner's guide and installation manual

Hunter

Hunter Highbury Owner's guide and installation manual

Water-Loo CSB 15-F Operating and maintenance instructions

Water-Loo

Water-Loo CSB 15-F Operating and maintenance instructions

HOMCOM 824-043V70 Assembly & instruction manual

HOMCOM

HOMCOM 824-043V70 Assembly & instruction manual

NuTone QTREN080FLT instruction manual

NuTone

NuTone QTREN080FLT instruction manual

Kruger RDA Series General instructions

Kruger

Kruger RDA Series General instructions

Deekax DIVK-C220 DEMA Installation and user manual

Deekax

Deekax DIVK-C220 DEMA Installation and user manual

Jata JVVT3141 Instructions of use

Jata

Jata JVVT3141 Instructions of use

NuAire NA-E-100 12V Series Installation and Maintenance

NuAire

NuAire NA-E-100 12V Series Installation and Maintenance

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.