S&P PCD110XP User manual

WARNING
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
CAUTION
CLEANING & MAINTENANCE
OPERATION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush
attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the
exact service motor. The impeller should also be replaced.
See “ELECTRICAL WIRING” for wiring and switch details.
VENTILATION FAN
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power
from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit
(ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces, or garages
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.
MODEL: PCD110XP
Cod: 0060302596
*The manual in electronic format can be download in our company web, or obtained from our dealer.
T
H
S
Max.
OFF
30
CFM
60%
50%
80%
75% 85%
100%
60min
20min 40min
OFF
OFF
5min
Humidity
sensor knob
Time delay
knob
Switch
position
Airflow (CFM) 80
1 2
110
1 2
140
1 2
Low airflow
knob
Toggle switch
The control box, located inside the fan housing, has four settings:
(1) The toggle switches set the fan high speed from 80 to 140 CFM (factory set to 110 CFM).
The fan will run at high speed when switch II is turned ON.
(2) The time delay knob sets the amount of time that the fan will continue to run at high speed
after switch II is turned OFF, or motion is detected (if enabled), or the RH% limit is reached
(if enabled). It is adjustable from 5 to 60 minutes. Once the set time has elapsed, the fan will
run at the low airflow knob setting (low speed). The time delay setting is de-activated when
set between OFF-5 mins (factory set to OFF). NOTE: for humidity sensing applications, the
fan will continue to run for 5 minutes after humidity is below the RH% limit, even if the time
delay knob is set between OFF-5 mins.
(3) The low airflow knob (low speed) sets the low airflow from 30 CFM up to the high speed
airflow rate. The low speed is de-activated when set between OFF-30 CFM (factory set to
OFF). The fan will run at low speed when switch I is turned ON and humidity is below the
RH% limit (if enabled), and motion is not detected (if enabled).
(4) The humidity sensor knob sets the RH% limit at which the fan will automatically operate at
high speed. The humidity sensor is de-activated when set between OFF-50% (factory set to
OFF).

OPERATION
PLAN THE INSTALLATION
ASSEMBLY INSTRUCTIONS
2
ROOF CAP*
(with built-in
damper)
ROUND
DUCT* WALL CAP*
(with built-in
damper)
*Purchase
separately
POWER
CABLE*
INSULATION*
(Place around and
over Fan Housing.)
Seal gaps
around
Housing.
FAN
HOUSING
ROUND
ELBOW(S) *
Seal duct
joints with
tape.
Keep duct
runs short
1. Sliding hanger bars have been provided, which allow the housing to be
positioned accurately anywhere between the framing. The bars span up to 24
in. and can be used on all types of framing: I-joist, standard joist, and truss
construction. Slide hanger bars onto housing and adjust as needed to fit
between framing.
2. Extend the hanger bars to the width of the framing. Position the ventilator
with the bottom edge of the hanger bar tabs are flush with the bottom edge of
the framing, holding the ventilator in place.Secure hanger bars to framing
using one screw on each end of hanger bar.Select a proper hole and secure
the hanger bars together using one screw.
Hanger Bar
screw
1. Do not install fan above or inside a 45-degree angle projected outwards from the cooking equipment element closest to
the fan.
2. Two ways to connect ductwork to a factory-shipped unit.
Operation Sequence
1. Turn switch I ON. The fan will run at low speed per the low airflow knob setting and the humidity/motion sensors will start sensing (if enabled).
2. Turn switch II ON. The fan will run at high speed per the toggle switch setting and will override the humidity/motion sensors (if enabled).
3. Turn switch II OFF. The fan will continue to run at high speed until the time delay has elapsed (if enabled), and then will automatically change back to
low speed.
4. Turn switch I OFF. The fan and all sensors (if enabled) are OFF completely.
HUMIDITY SENSOR OPERATION
The fan runs continuously at a low speed (if enabled, set by the low airflow knob) and automatically boosts up to high speed when the relative humidity
(RH%) in the room exceeds the RH% limit set with the humidity sensor knob. If the fan continuously responds to changing environmental conditions (too
sensitive), the RH% limit may need to be adjusted.
SENSITIVITY ADJUSTMENT
The “H” limit has been factory set for most shower applications. However, if the fan is in a tub area or is being used for moisture control, the “H” may
need to be increased toward 100%. If the fan is responding too often to changing environmental conditions, the “H” setting may need to be decreased
toward 50%.
To adjust the “H” limit:
1. Disconnect power at service entrance.
2. Through the grille, locate the slot marked “H”.
3. Carefully rotate the “H” adjustment toward 50% or 100%.
4. Turn on power and check operation by turning on the shower or other humidity source until the fan turns on.
5. Repeat above steps if necessary.
When the temperature changes, humidity sensor values will have some amount of deviation.
MOTION SENSOR OPERATION
Optionally, the standard plastic grille can be replaced with a motion sensing or lighted motion
sensing grille. Simply plug the motion sensing grille into the fan control module (see “Install Grille”
section, page 3) and when powered on, the fan will automatically start sensing motion. The fan
runs continuously at a low speed (if enabled, set by the low airflow knob) and automatically boosts
up to high speed when motion is detected. A green indicator light will illuminate continuously when
motion is detected. The sensing distance will be dependent on the installation. The diagrams to
the right provide a general layout.
Recommended installation height: 7 to 9 feet.
Sensing range is within the 90° cone per the diagram to the right.
7 to 9 feet

ASSEMBLY INSTRUCTIONS
ELECTRICAL WIRING
INSTALL GRILLE
3
3. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper/duct connector,
and run the ductwork to a roof or wall cap (not included). Using tape (not
included),
secure all the ductwork connections so that they are air tight.
The ducting from this fan to the outside of building has a strong effect on the
air flow, noise and energy use of the fan.
Use the shortest, straightest duct routing possible for best performance, and
avoid installing the fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit mold growth. Fans
installed with existingducts may not achieve their rated air flow.
Install ceiling material to complete the ceiling construction and cut around the
fan housing.
To attach the grille assembly to the fan housing, pinch the grille springs on the
sides of the grille assembly and position the grille into the housing with the
grille springs in the appropriate slots. Push the grille assembly towards the
ceiling to secure.
OPTIONAL MOTION OR LIGHTED MOTION SENSING GRILLE
Insert the plug from the sensor system into the power box. Attach the wire to
the blower. To attach the grille assembly to the fan housing, pinch the grille
springs on the sides of the grille assembly and position the grille into the
housing with the grille springs in the appropriate slots. Push the grille
assembly towards the ceiling to secure.
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
UNIT
BLACK (BLK)
SWITCH BOX
SWITCH I
POWER SUPPLY
120V AC
GROUND (GRD)
WHITE (WHT)
FAN
RECEPTACLE
WIRE
PANEL
SWITCH II
BROWN (BRN)
FAN
BRN
BLK
BLK
LINE
IN
WHT
WHT
GRD
UNITSWITCH BOX
GRD
SWITCH I
SWITCH II

WARRANTY
SERVICE PARTS
4
S&P USA Ventilation Systems, LLC. & S&P Canada Ventilation Products, Inc. warrants to the original end user of its
products that our exhaust fans will be free from defects in materials and workmanship for a period of Five (5) years from
the date of original purchase. 6 years warranty for motor and 5 years warranty for the remaining fan parts. THERE ARE
NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED
WARRANTIES OF SUITABILITY FOR A PARTICULAR PURPOSE.
During this five year period, S&P will, at its option, repair returned products or parts, or provide replacement products or
parts, without charge, for any product or part which is found to be defective under normal use.
This warranty does not cover normal maintenance and service or any parts that have been subject to misuse, negligence,
accident, improper maintenance or repair, faulty installation or installation contrary to recommended installation instructions.
S&P’s obligation to repair or replace, at S&P’s option, shall be the purchaser’s sole and exclusive remedy under this
warranty. No labor or materials are covered by this warranty. S&P shall not be liable for incidental damages arising out of
or in connection with product use or performance.
This warranty gives you specific legal rights. You may also have other rights which vary from state to state.
To qualify for warranty service, you must notify S&P at the address or telephone number stated below, provide the model
number and part identification, and describe the nature of any defect in product or part. You may be required to ship a
defective part to S&P. There will be no charge for shipping repaired or replacement parts from S&P to you if your address
is in the United States or Canada. At the time of requesting warranty service, you must present evidence of the original
purchase date.
S&P USA Ventilation Systems,LLC.
6393 Powers Avenue Jacksonville, FL 32217
P. 904-731-4711
F. 904-737-8322
www.solerpalau-usa.com
S&P Canada Ventilation Products, Inc.
6710 Maritz Drive Unit #7 Mississauga, ON L5W 0A1 - Canada
T. 416-744-1217
F. 416-744-0887
www.solerpalaucanada.com
PART PART NAME Qty.
1
2
3
4
9
10
11
12
a
Housing
Wiring plate
Damper / Duct Connector
Screw
1
2
1
1
1
1
1
1
4
b Screw 5
c Screw 4
d Screw 6
Grille Assembly (includes part 2)
51
Blower
61
Blower Wheel
71
Motor Plate
84
Motor
Grille Spring
WARNING: Ensure that the fan is switched off from the supply
mains before replacing.
Wire Panel / Harness Assemblye
Hanger Bar Kit
Control Box
* Blower Assembly includes part 3, 4, 5, 6, 7, b, c
1
2
7
6
5
4
8
3
9
12
10
d
a
a
11
c
b
Table of contents
Other S&P Fan manuals

S&P
S&P VENT-355 Manual

S&P
S&P Duovent Series User manual

S&P
S&P decor-100 DC User manual

S&P
S&P DUOVENT COMPACT RV Series User manual

S&P
S&P CTB ECOWATT PLUS User manual

S&P
S&P CK-35 User manual

S&P
S&P DECOR-100 VISUAL User manual

S&P
S&P RESPIRO 100 User manual

S&P
S&P ARTIC N GR Series User manual

S&P
S&P TURBO-355 N User manual
Popular Fan manuals by other brands

Jero Productions
Jero Productions Primabat AirBox Convertible Upgrade HP How to use

Ventop
Ventop V 10 installation instructions

Soleus Air
Soleus Air ST-2005 user manual

Caryaire
Caryaire LVLS installation manual

Exido
Exido 271-105 Specifications

Monte Carlo Fan Company
Monte Carlo Fan Company 5EM68 Series Owner's guide and installation manual