S&P LPD User manual

Models LPD and RED
Installation, Operation, and Maintenance Manual
6393 Powers Avenue
Jacksonville, FL 32217
P: 800.961.7370
F: 800.961.7379
Direct Drive Centrifugal Exhausters
Low Prole Roof/Sidewall and Roof Downblast
READ AND SAVE THESE INSTRUCTIONS
The purpose of this manual is to aid in the proper installation and operation of fans
manufactured by Soler & Palau USA. These instructions are intended to supplement good
general practices and are not intended to cover detailed instruction procedures, because of
the wide variety and types of fans manufactured by Soler & Palau USA.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
INTRODUCTION:
DO NOT INSTALL, USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND
UNDERSTOOD. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE USE.
It is the responsibility of the purchaser to assure that the installation and maintenance of this equipment is handled by
qualied personnel experienced in such work and equipment.
Contact your local representative should you need further information.
SHIPMENT AND RECEIVING:
Prior to shipment, all fans have been thoroughly inspected and tested.
All equipment shipped from Soler & Palau USA is skidded or crated to fully comply with trucking requirements. Inspect
all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER’S BILL OF
LADING AND FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY, IN THE CASE OF ANY DAMAGE.
Keep a record of all equipment received, including inspection details and date of receipt, because of the possibility of
partial shipments.
If you receive damaged goods, contact your S&P representative for repair or replacement service.
HANDLING:
Handle your equipment with caution. Some fans are provided with lifting lugs or holes for easy handling. Others must
be handled using nylon straps that protect the fan’s coating and housing. Spreader bars should be used when lifting
large parts.
Fans should be lifted by using straps around the fan housing only. DO NOT LIFT FANS BY THE MOTOR, BASE,
PROP, WHEEL, OR FLANGES.
Roof ventilators should be lifted by using straps around the fan housing or base only. Spreader bars should also
be used to avoid damage to stack caps or hoods. DO NOT LIFT ROOF VENTILATORS BY THE STACK CAP OR
HOOD. On hooded units, disassemble the stack from hood when lifting. Upblast models may be lifted assembled.
STORAGE:
If fans are stored for any length of time, they should be stored in a clean, dry location to prevent rust and corrosion.
Outdoor storage is not recommended. When outdoor storage is necessary, they should be protected from the
elements as best as possible. Cover the fan inlet and outlet and keep motors dry and clean.
For extended storage (more than 3 months), motor shafts should be rotated monthly. Storage records should be
kept to assure proper maintenance. The factory can advise warranty centers to provide motor and bearing service if
needed.
INSTALLATION:
Roof ventilators should always be mounted to a at level, solid and rigid structure. Particular caution should be
exercised when installing fans on metal buildings. Be sure wall or roofs are capable of supporting the fan(s). Walls/
Roofs not supported correctly will cause vibration that could cause damage or injury.
Fans mounted off ground level should be rigidly mounted to a special platform and be placed as near as possible to,
or over, a solid wall or column.
Supports for suspended fans must be crossbraced for live load support to prevent side sway.
Use guy wires to help secure root units if excessively windy conditions prevail.
1

1. CAUTION! This fan contains rotating parts and requires special service. Appropriate safety precautions
should be taken during installation, operation and maintenance.
2. WARNING! Do not install or operate this fan in an environment or atmosphere where combustible or
ammable materials, gasses or fumes are present, unless it was specically designed and manufactured
for use in that environment. Explosion or re can result. Explosive, corrosive, high temperature, etc.
conditions may require special construction, inspection and maintenance. It is necessary to observe the fan
manufacturer’s recommendations and limitation concerning the type of material to be handled by the fan and
its application in special conditions.
3. When ventilator is designed to be mounted on a curb, the curb should be securely installed prior to fan
installation.
4. A damper, if used, should be securely mounted within the curb or wall in a manner that allows free and
unobstructed operation.
5. CAUTION! All electrical work must be done in accordance with local and/or national electrical codes as
applicable. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualied
electrician.
6. WARNING! This product must be grounded.
7. DANGER! Make sure power is turned off and locked in the OFF position at the service entrance before
installing, wiring or servicing fan.
8. CAUTION! Before wiring the motor, check the supply voltage against the motor nameplate voltage. High or
low voltage can damage the motor and void the motor warranty.
9. WARNING! Be sure to keep all wiring clear of rotating or moving parts.
10. WARNING! Before starting the fan, turn the wheel to assure it rotates freely. If needed, adjust the wheel/shaft/
motor position as required to achieve necessary clearances.
11. WARNING! Check all setscrews and keys. Tighten as necessary prior to fan startup.
12. On roof units, anchor the fan securely to the curb. Anchoring through the vertical portion of the curb cap
ange is recommended. Use a minimum of four lag bolts or other suitable fasteners.
13. Due to the general nature of its applications, the basic air mover is available with protective guards and/or
other devices for required operating safety as with most installations of rotating machinery. Before operating
the basic unit in any of its applications determine requirements for such guards and/or devices needed
for protection against accidental contact with moving parts or against injury to nearby personnel or critical
equipment due to accidental rupture of fast moving parts.
START-UP:
Lock out the power source.
Tighten all bolts and setscrews securely. NOTE THAT ALL BOLTS AND SETSCREWS SHOULD BE TIGHTENED
AFTER TWO DAYS OF INITIAL OPERATION.
Clearance should be checked all around between wheel or propeller tips and the housing before starting up. The
wheel or propeller should not strike the housing.
No initial lubrication is required. Motors have been pre-lubricated by motor manufacturer.
Arrows to show direction of rotation and airow are attached to the fan housings.
After the electrical connections are completed, apply just enough power to start the impeller as indicated by the
directional arrows on the unit. If the impeller is turning the wrong direction, it will not deliver rated airow and the motor
connections must be altered to correct rotation.
2

Lock out the power source before the installation of all accessories.
Fan electrical power can now be applied and special attention should be given to determine if motor is working
properly. At this time, with air system in full operation, with guards attached, it is well for the electrician to measure
the operating amperage of the motor and compare with the nameplate rating to determine that the motor is operating
under safe load conditions.
The fan should not need balancing, as it was balanced at the factory to meet stringent vibration levels before
shipment. However, there are several things that may cause vibration, such as rough handling in shipment and
erection, weak foundations, and alignments.
MAINTENANCE:
1. Before performing any maintenance on the fan, be sure power is turned off and locked in the OFF position at
the service entrance before servicing the fan.
2. Ventilators should be carefully checked at least once a year. For critical or rugged applications, a routine
check every two or three months is suggested.
3. All motors supplied with Soler & Palau USA ventilators carry a one (1) year warranty from date of shipment.
For repairs within the warranty period, the motor must be taken to the motor manufacturer’s authorized
service dealer. Contact your representative for additional warranty details.
4. A periodic motor check should consist of spinning the motor shaft with the power off to be sure the motor turns
freely.
5. Check sheave set screws to ensure tightness. Proper keys must be in keyways.
6. Do not readjust blade pitch or fan RPM. If sheaves are replaces, use only sheaves of identical size and type.
7. During the rst few months of operation, it is recommended that the setscrews be checked to assure they are
tight.
8. The rotating wheel or propeller requires particular attention in most applications since materials in the air
being handled can build up on the blades to cause destructive vibration; and may also corrode and/or erode
the blade metal to weaken the structure of the propeller. Regular inspection and corrective action at intervals
determined by the severity of each application are essential to good service life.
MOTORS:
The fundamental principle of electrical maintenance is KEEP THE MOTOR CLEAN AND DRY. This requires periodic
inspection of the motor. The frequency depends upon type of motor and the service.
We recommend periodic checks of voltage, frequency, and current of a motor while in operation. Such checks assure
the correctness of frequency and voltage applied to the motor, and yield an indication of the fan load. Comparison
of this data with previous data will give an indication of the fan performance. Any serious deviations should be
investigated and corrected.
Lubricate integral horsepower motors per the motor manufacturer’s recommendations. Lubrication frequency depends
on the motor horsepower, speed, and service. Use compatible greases.
1. All motors carry a one (1) year warranty from date of shipment. For repairs within the warranty period, the
motor must be taken to the motor manufacturer’s authorized service dealer. Contact your representative for
additional warranty details.
2. A periodic motor check should consist of spinning the motor shaft with the power off to be sure the motor turns
freely.
3

REPAIR PARTS:
3. Fan Blades – Repair of individual fan blades or propeller assemblies is not recommended. Contact factory
with blade size, number of blades, bore size, motor HP, air ow direction, rotation, fan RPM or sheave sizes
and any order/tag information that is available for replacement.
4. Misc. Parts – Not available from local trade channels should be returned for repair or replacement. Be sure to
obtain return tags or authorization before shipment.
5. Electric Motors – Repair or replacement of motors is normally performed by a repair station authorized by the
manufacturer. Contact your representative or the factory for locations nearest to you. DO NOT ship motor to
the factory without specic authorization.
FAN TROUBLE-SHOOTING CHART
PROBLEM POSSIBLE CAUSES
Excessive Vibration Propeller, wheel or sheaves loose on shaft
Out of balance propeller
Excessive buildup of dirt/dust on propeller
Bent shaft
Weak mounting base for fan
Fan mounting bolts loose
Loose or worn bearings
Bearing or drive misalignment
Structures not crossbraced (wall fans)
Curb not at and level
Excessive Horsepower Static pressure higher than design
Wheel or propeller rotating in wrong direction
Fan speed higher than design
Too Little Air Restricted fan inlet or outlet
Filters are dirty or clogged
Wheel or propeller rotating in the wrong direction
System is more restrictive (more static pressure) than expected
Fan speed lower than design
Inlet or Outlet screens clogged
Too Much Air Filters not in place
Fan speed higher than design
System is less restrictive (less static pressure) than expected
Fan Does Not Operate Wrong voltage
Electricity turned off or note wired properly
Blown fuses
Overload protector has broken circuit
Excessive Noise Propeller, wheel or sheaves loose
Accumulation of material on propeller
Worn or corroded propeller
Wheel or propeller out of balance
Wheel or propeller hitting housing
Bent shaft
Loose fan mounting bolts
Rattle of components in high velocity airstream
Electrical noise
Noise from high velocity air system
Vibrating parts not isolated from building
Vibrating duct work
4

5
Model
RED
Motor
Cover
1
Skirt
2
Support
Legs
(4 Required
per unit)
3
Motor Cover
Brackets
(4 Required
per unit)
4
Windband
Birdscreen
5
Rubber Grommets
6Wheel
7
4 Required
per unit
1 Required
per unit
Part # Part # Part # Part # Part # Part # Part # Part #
6 100460 100453 100441 100452 100445 100359 92106810 600008
810/812 100460 100453 100442 100452 100446 100359 92106810 600010
825 100454 100453 100442 100452 100446 100359 92106810 600009
10 100454 100453 100451 100452 100457 100459 92106810 600003
12 100480 100498 100471 100452 100473 100459 92106810 600004
15 100480 100498 400471 100452 100473 100459 92106810 600005
1
3
4
2
5
6
7
Replacement Parts
Model LPD
Model
LPD
Cover
Dome
1
Welded
Base
2
Motor Bracket w/
Isolators
(2 Required)
3
Part # Part # Part #
6 101101 101107 101103 & 105744
8 101101 101102 101103 & 105744
Model
LPD
Disconnect
Switch
6-1
Speed
Control
6-2
Motor
(115V or 230V - 50/60Hz)
& Wheel 1 PC Assembly
7
Capacitor
8
Conduit Assembly
Conduit, compression tting
& sealing nut 9
Part # Part # Part # Part # Part #
6 2507.2.GE 2525.5UL 605410 (115V) 605414 (115V) 101108, 609159 & 610022
or 605411 (230V - 50/60Hz) or 605415 (230V - 50/60Hz)
8 2507.2.GE 2525.5UL 605412 (115V) 605416 (115V) 101108, 609159 & 610022
or 605413 (230V - 50/60Hz) or 605415 (230V - 50/60Hz)
1
3
4
2
5
7
6-1 6-2
8
9
Model RED
Model
LPD
Windband,
Birdscreen,
Edging, Trim Lok
4
Cover
Brackets
(2 Required)
5
Part # Part #
6101124 101105
X1010
8101124 101105
X1010
LPD-RED_Parts_0307

6
WARRANTY:
Soler & Palau USA warrants this equipment to be free from defects in material and workmanship for ve (5) years
from date of shipment. Any units or parts which prove to be defective and are reported during the warranty period will
be replaced at our option when returned to our factory, transportation prepaid. Deterioration or wear by heat, abrasive
action, chemicals, improper installation or operation or lack of normal maintenance shall not constitute defects, and
are not covered by warranty.
The motor is warranted by the motor manufacturer for one (1) year. If the motor becomes defective in the warranty
period, it should be taken to the nearest authorized motor service station. If this is not done, the motor manufacturer
will not warrant the motor. Call the factory for instructions if authorized service station is not known.
Soler & Palau USA will not be responsible for any installation, removal or re-installation costs or any consequential
damage resulting in failure to meet conditions of any warranty.
LIMITATION OF WARRANTY AND LIABILITY
This warranty does not apply to any such S&P product or parts which have failed as a result of faulty installation or
abuse, or incorrect electrical connections or alterations, made by others, or use under abnormal operating conditions
or misapplication of the products and parts.
Soler & Palau USA will not approve for payment any repairs made outside the factory without prior written consent of
its Jacksonville, Florida ofce.
The foregoing shall constitute our sole and exclusive warranty and our sole and exclusive liability and is in lieu of
all other warranties, whether written, oral, implied or statutory. There are no warranties which extend beyond the
description of the page hereof. Seller does not warrant that said goods and articles are of merchantable quality or
that they are t for any particular purpose. The liability of seller on any claim of any kind, including negligence, for any
loss or damage arising out of or connected with, or resulting from the sale and purchase of the products and parts
covered by this proposal, acknowledgement, order or from the performance or breach of any contract pertaining
to such sale or purchase, or from the design, manufacture, sale, delivery, resale, installation, technical direction of
installation, inspection, repair, operation or use of any products or parts covered by this proposal, acknowledgement,
order or furnished by seller shall, in no case exceed the price allocable to the products or parts thereof which give rise
to the claim and shall terminate one (1) year after the shipment of said products and parts.
In no event, whether as a result of breach of contract, or warranty or alleged negligence, defects, incorrect advice or
other causes, shall seller be liable for special or consequential damages, including, but not limited to, loss of prots
or revenue, loss of use of the equipment or any associated equipment, cost of capital, cost of substitute equipment,
facilities or services, down time costs, or claims of customers of the purchaser for such damages. Soler & Palau USA
neither assumes nor authorizes any persons to assume for it any other liability in connection with the sale of its fan
products and parts. Some states do not allow the exclusion or limitation of incidental or consequential damages, so all
of the above limitations or exclusions may not apply to you.
SAFETY ACCESSORIES WARNING:
The responsibility for providing safety accessories for equipment supplied by Soler & Palau USA is that of the
installer and user of this equipment. Soler & Palau USA sells its equipment with and without safety accessories, and
accordingly it can supply such safety accessories upon receipt of order.
The user, in making its determination as to the appropriate safety accessories to be installed and any warning
notices, should consider (1) the location of the installation, (2) the accessibility of employees and other persons
to this equipment, (3) any adjacent equipment, (4) applicable building codes, and (5) requirements of the Federal
Occupational Safety and Health Act. Users and installers of this equipment should read “RECOMMENDED SAFETY
PRACTICES FOR AIR MOVING DEVICES” which is published by Air Movement and Control Association, 30 West
University Drive, Arlington Heights, Illinois 60004.
This manual suits for next models
1
Table of contents
Other S&P Fan manuals

S&P
S&P HTB-75 RC Technical Document

S&P
S&P CAB-PLUS Series User manual

S&P
S&P KIT SILENT-100 ECOWATT 12V User manual

S&P
S&P HTB-2500 Quick guide

S&P
S&P Silent Design User manual

S&P
S&P TD-500/150-Silent User manual

S&P
S&P MDX-ES24VK User manual

S&P
S&P PCD110XM User manual

S&P
S&P EDM-80N Manual

S&P
S&P ARTIC-405 CN GR User manual