Comptronic 6124 and 6125 Electronic Safe Locks
Management Guide, Dual Control
b.
Time Delay Duration
Time delay can be set to delay opening from 1 to 99 minutes. Security Note: Changes to the time
delay duration can only be made during the opening window. If the time delay parameter has been
set and you want to change it, enter a valid 6-digit code to start the time delay. When Time Delay
expires (the lock emits 10 rapid beeps) and the Opening Window has begun, set your Time Delay
minutes. (To eliminate the Time Delay period, simply enter zero for the time delay minutes.) Enter:
7 4 * [Master Code] # ***** [User Code] # ***** 0 0 # *** [TD min] # *** [TD min] # ***
For example, to set the Time Delay to 15 minutes, enter:
7 4 * [Master Code] # ***** [User Code] # ***** 0 0 # *** 1 5 # *** 1 5 # ***
9.
Changing the Batteries
Carefully remove the keypad housing by first lifting the bottom edge (closest to the S&G logo) and then
easing it off the base. Detach the old batteries from the terminals. To prevent bending or breaking the
holder, support the top of each battery holder as you insert each fresh battery (Duracell7 alkaline
batteries are recommended). Note: No codes or settings are lost during battery replacement.
10.
Keypad Tamper Indicator (OPTIONAL: MUST BE ORDERED) Required for Vds rating.
If this option is installed, the lock records each time the lock keypad housing is unseated or removed.
If the housing is disturbed, the Keypad Tamper Indicator beeps an SOS warning signal the next time
you attempt to enter a valid access code. The lock will not open; it beeps the SOS: 3 short/high
beeps, 3 short/low beeps, 3 short/high beeps. This signal is repeated twice. When it stops, enter a
valid code within one minute and the Keypad Tamper Indicator will reset and the lock will open.
11.
Duress Indicator and Investigation (ORDER DURESS MODULE SEPARATELY)
Your Comptronic lock has duress capability (a silent alarm option). Installation of the duress signal box
is required for proper connection to your alarm system. Use the instructions provided with the duress
signal box to ensure accurate installation and connection.
Enable the Duress Feature
When the lock is installed with the duress signal box, you then need to enable the duress feature.
Enter:
3 8 * [Master Code] # ***** 1 #*** 1 #***
Your lock is now capable of sending a duress signal to the duress signal box.
Send a Duress Signal
When the duress feature is enabled, you can send a duress signal (silent alarm) by altering the last
number of your Code by plus or minus one number. For example, if your code is 246812, you would
enter either 246811 or 246813 followed by # to send the duress signal. Either (or both) users and the
TDO code can send the duress signal (with or without time delay programmed), and also may be sent
by Master Code, Supervisor Code, or User Code during programming sequences.
Duress Investigation
If your Comptronic lock has the duress (silent alarm) capability enabled, you can tell if a lock has sent a
duress signal. Fifteen minutes after a duress signal has been sent, you can “interrogate” the lock by
pressing and holding down the * key for at least 4 seconds. The lock will emit a continuous alternating
series of high- and low-pitch beeps for approximately 4 seconds to let you know the lock has sent a
duress signal.
Reset the Duress Investigation Signal
To reset the duress investigation signal, enter the Master or Supervisor Code within one minute after
the investigation signal ends. (Lock does not open.)
Disable the Duress Feature
You can disable the duress feature without disconnecting a functioning duress signal box. Enter:
3 8 * [Master Code] # ***** 0 # *** 0 # ***