Contents Warnings and Safety Precautions
2Warnings and Safety Precautions
3General View of the Equipment
4Installation
4 Storage and Shipping Conditions
4 Incoming Inspection
4 Equipment Supplied
4 Installation Instructions
4 Connecting the Weigh Cell to the
Electronics Module
5 Connecting the Weigh Cell to
AC Power
6 Setting up the Weigh Cell
6 Attaching a User-specific Transducer
7 Leveling the Weigh Cell
Operation
8 Notes on Analytical Weighing
9 Below-Cell Weighing
10 Configuration
11 Parameter Settings (Overview)
13 Interface Port: RS-232
16 Pin Assignment Chart
17 Cabling Diagram
18 Troubleshooting Guide
19 Overview
19 Specifications
20 Dimensions (Scale Drawings)
22 Accessories (Options)
23 Declaration of Conformity
Description
of the System
– The WZA225-CW/WZA26-CW is a
compact weigh cell that can be affixed
to a smooth surface.
– The weigh cell has a built-in calibration
weight and can be calibrated and
adjusted by transmitting a control
command, or at the press of a key using
the optional display and control unit.
– These compact weigh cells can be used
to determine weights within restricted
space.
The weigh cells have been developed
for:
– Installation in measuring devices and
production machinery
– High-precision weighing within limited
space
– Precise weight determination on active
production lines
Safety Precautions
§Once it has been installed, the weigh
cell must be checked for the following:
– Compliance with directives and stan-
dards for electrical apparatus
– Electromagnetic compatibility of the
complete weighing instrument
– Compliance with mandatory safety
regulations
§To prevent damage to the equipment,
read these installation instructions care-
fully before operating the weigh cell.
§These installation instructions describe
only the technological specifications of
the weigh cell and the conditions that
must be observed during installation.
The specific procedures to follow when
performing installation will depend
on the particular system in which the
weigh cell is installed.
!Always make sure the equipment is
disconnected from power before per-
forming any installation, maintenance
or repair work.
!Exposure to excessive electromagnetic
interference can cause the readout
value to change. Once the disturbance
has ceased, the instrument can be used
again in accordance with its intended
purpose.
!The equipment may be opened only
by authorized service technicians who
have been trained by Sartorius and who
follow Sartorius’ standard operating
procedures for maintenance and repair
work.
!Make absolutely sure to disconnect the
electronics module from power before
you connect or disconnect any elec-
tronic peripheral devices to or from the
data interfaces.
Installation Requirements
!Do not use this equipment in hazardous
areas, zones exposed to explosive gases
or dusts, nor areas exposed to poten-
tially explosive materials.
!Use of the weigh cell in areas where
medical equipment is operated is not
permitted.
!If you connect a different weigh cell or
electronics module from Sartorius, make
sure to connect devices that are made
to be operated together. Check the
equipment numbers before connecting
the devices.
!Any incoming inspection or installation
work that does not conform to the
instructions in this manual will result in
forfeiture of all claims under the manu-
facturer’s warranty.
!If you use electrical equipment in
installations and under ambient condi-
tions subject to stricter safety standards
than those described in the manual,
make sure you comply with the provi-
sions as specified in the applicable reg-
ulations for installation in your country.
!All components in the system must be
grounded (earthed), including any draft
shield added to the equipment. Connect
an equipotential bonding conductor.
!If you use electrical equipment in
installations and under ambient condi-
tions subject to stricter safety standards
than those described in the manual,
make sure you comply with the provi-
sions as specified in the applicable reg-
ulations for installation in your country.
– Warning when using pre-wired RS-232
connecting cables: RS-232 cables pur-
chased from other manufacturers often
have incorrect pin assignments for use
with Sartorius equipment. Be sure to
check the pin assignments against the
chart in these instructions before con-
necting the cable, and disconnect any
lines identified differently from those
specified by Sartorius.
– Note on installation:
The operator shall be responsible for
any modifications to Sartorius equip-
ment and for connections of cables
not supplied by Sartorius and must
check and, if necessary, correct these
modifications. On request, Sartorius will
provide information on the minimum
operating specifications (in accordance
with the standards for defined immuni-
ty to interference).
$If there is visible damage to the equip-
ment or power cord, disconnect the
equipment from power and replace the
weigh cell and electronics module.
– Do not expose the equipment to
aggressive chemical vapors or to
extreme temperatures, moisture, shocks,
or vibration.
$If you have any problems with the
equipment, contact your local Sartorius
office, dealer or service center.
Hotline
§For technical support regarding the
design, specifications or installation of
the weigh cells, contact your local
Sartorius dealer or contact the Sartorius
hotline (in Germany) at:
Phone: +49.(0)551.308.4440
Fax: +49.(0)551.308.4449
2