6 VIVER SATEL
– gray: the module is not to record camera image.
With regard to the inputs, colors have the following meaning:
– green: input is not violated,
– red: input is violated.
12 – VIVER. Configuration of the module network parameters:
Identifier – enter in this field a sequence of 1 to 8 alphanumeric characters to identify
the module.
Password – a code enabling the module to be logged in to the monitoring station (from
1 to 18 alphanumeric characters).
DHCP – select this box if the data regarding IP address, subnet mask and gateway are
to be automatically downloaded from the DHCP server.
IP address – IP address of the module.
Subnet mask – mask of the subnet in which the module operates.
Gateway – the gateway, i.e. the IP address of the network device through which the
other devices in the given local network can communicate with devices in other
networks.
13 – Module status. The strip shows the status of communication between the device and
computer: green color – connected; gray color – not connected.
14 – Image. Size of recorded image – 1/1, 1/2, 1/4; and kind of recording – color or black-
and-white.
15 – Monitoring station. Configuration of the parameters of communication between the
module and the STAM-2 monitoring station:
Ethernet – select the box if communication with the monitoring station is to be effected
via the Ethernet network.
IP address – IP address of the monitoring station.
Port – enter in this field the number of TCP port through which communication with the
monitoring station will be effected. You can enter values from 1 to 65535. Factory
default: 3010.
Connection holding time – the time of waiting for response of the monitoring station
operator to invoke the live view from the given camera (0–240 seconds; for 0 the
view mode can only be invoked when sending the pre- and post-event images). The
time is to be programmed separately for communication through Ethernet and for
modem communication.
Maximum view time – parameter defining how long the “live” view can last (0–20
minutes; for 0 the live view will not be possible). The time is to be programmed
separately for communication through Ethernet and for modem communication.
Test transmission every – parameter defining how often (every 0–20 minutes) the
device will send to the monitoring station the information about its working order (for
0, no test transmission will be sent by the module).
Modem 1/Modem 2 – select the box to indicate if communication with the monitoring
station is to be effected through the modem. The module can communicate with two
modems (with 2 different telephone numbers).
Tel. number – telephone number of the monitoring station (maximum 24 digits).
Number of retries – the number of attempts to establish modem connection with the
monitoring station in order to transmit images stored in the module memory (0–20;
for 0, the module will not be making any further attempts to connect).