®INDIGO TESTER
t_indigo_en 08/08
The INDIGO TESTER imitates the sound of broken glass, which enables the INDIGO digital
glass breaking detectors to be checked for correct functioning. The device can emit the
sound of breaking plate, laminated or tempered glass. The tester is protected against
accidental switching-on. In order to start operation of the tester you should:
1. Press one of the buttons for approx. 2.5 seconds – during that time the LED is rapidly
blinking. Afterwards, the sound of broken glass will be generated.
2. If you subsequently press any button, the sounds will be generated immediately. If the
LED is on during sound generation, the battery is low. For the test results to be correct, the
battery must be replaced.
3. The tester remains ready for immediate sound generation for 20 seconds since the last
push of a button. This state is indicated by short flashes of the LED occurring every 2.5
seconds. If the LED stops blinking, you should switch the tester on again as described
above in it. 1.
Notes:
•Because the tester emits a very loud sound, it must not be used at a distance less than
1 meter from the ear, or the sound wave intensity may permanently impair your hearing.
•Only 9V 6LR61 alkaline batteries should be used to power the device.
•When the tester operation becomes erratic, or the battery discharge is signaled,
promptly remove the batteries from the device.
•The used-up batteries must not be thrown away, but should be disposed of as required
by the existing regulations (European Union Directives 91/157/EEC and 93/86/EEC).
The functional test of INDIGO glass breaking detector should be carried out before making
the wire connections. You may use a temporary power source (e.g. a battery) to supply the
detector. In order to check whether the place of detector installation ensures the optimum
detection range, follow the procedure below:
1. Start the detector test mode, in which the detector only generates an alarm on registering
a high-frequency signal (remove jumper from J3 pins on the detector board).
2. Place the tester close to the window – preferably as far as possible from the detector –
and press the corresponding button to generate the sound characteristic of the given type
of glass.
3. If alarm is signaled, the detector location is correct, however, to be on the safe side, it is
recommended that the test be repeated several times.
4. If the detector fails to react to the tester generated sounds, adjust the detection sensitivity
using the detector on-board potentiometer, and if the result is still unsatisfactory, change
the detector installation place.
5. End the detector test mode (set jumper on J3 pins).
Notes:
•Make sure that that the test is carried out in the detector working conditions, i.e. the
detector housing should be closed, and where the window is covered by louvers or
curtains, the tester should be placed behind them.
•In the event of large glazed surfaces, it is recommended that the test be carried out at
several points of the window.
View of INDIGO TESTER
Technical Data
Power supply: ...................................................................................alkaline battery 9V 6LR61
Type of imitated sounds:............................................................................plate glass breaking
............................................................ laminated glass breaking
.............................................................tempered glass breaking
Weight................................................................................................................................110g
SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gdańsk
POLAND
tel. (+48 58) 320 94 00
www.satel.pl
info@satel.pl
Latest EC declaration of conformity
and product approval certificates
can be downloaded from our Web
site www.satel.pl
L– button to generate
laminated glass sound
P– button to generate
plate glass sound
T– button to generate
tempered glass sound
low-battery LED – goes on
when pressing sound
generating buttons if the
battery is discharged

Other Satel Security Sensor manuals

Satel AGATE User manual

Satel

Satel AGATE User manual

Satel AVD-100 User manual

Satel

Satel AVD-100 User manual

Satel IVORY User manual

Satel

Satel IVORY User manual

Satel CD-2 User manual

Satel

Satel CD-2 User manual

Satel AGD-200 User manual

Satel

Satel AGD-200 User manual

Satel SPL-TO User manual

Satel

Satel SPL-TO User manual

Satel AQUA RING User manual

Satel

Satel AQUA RING User manual

Satel SLIM-DUAL-LUNA-PET User manual

Satel

Satel SLIM-DUAL-LUNA-PET User manual

Satel ADD-200 User manual

Satel

Satel ADD-200 User manual

Satel AOCD-260 User manual

Satel

Satel AOCD-260 User manual

Satel OPAL Plus User manual

Satel

Satel OPAL Plus User manual

Satel APMD-150 User manual

Satel

Satel APMD-150 User manual

Satel AQUA S User manual

Satel

Satel AQUA S User manual

Satel micra MPD-310 Pet User manual

Satel

Satel micra MPD-310 Pet User manual

Satel SLIM-DUAL-PRO User manual

Satel

Satel SLIM-DUAL-PRO User manual

Satel abax 2 ACD-220 User manual

Satel

Satel abax 2 ACD-220 User manual

Satel AGD-200-BR User manual

Satel

Satel AGD-200-BR User manual

Satel AXD-200-DG User manual

Satel

Satel AXD-200-DG User manual

Satel GRAPHITE User manual

Satel

Satel GRAPHITE User manual

Satel OPAL User manual

Satel

Satel OPAL User manual

Satel MAGENTA User manual

Satel

Satel MAGENTA User manual

Satel OPAL Pro User manual

Satel

Satel OPAL Pro User manual

Satel COBALT User manual

Satel

Satel COBALT User manual

Satel MGD-300 User manual

Satel

Satel MGD-300 User manual

Popular Security Sensor manuals by other brands

D+H PD-C180i/16 DH Original instructions

D+H

D+H PD-C180i/16 DH Original instructions

jablotron JA-85P quick start guide

jablotron

jablotron JA-85P quick start guide

VOLTCRAFT LSG-10 operating instructions

VOLTCRAFT

VOLTCRAFT LSG-10 operating instructions

Evikon E2608-CO2-10K user manual

Evikon

Evikon E2608-CO2-10K user manual

EVERSPRING SP819 quick start guide

EVERSPRING

EVERSPRING SP819 quick start guide

STEINEL L830LED iHF Cubo instructions

STEINEL

STEINEL L830LED iHF Cubo instructions

NMT V-Detector user manual

NMT

NMT V-Detector user manual

Scott Safety EPIC 3 RDI Quick reference guide

Scott Safety

Scott Safety EPIC 3 RDI Quick reference guide

Apollo ORBIS ORB-OH-13003-APO Product guide

Apollo

Apollo ORBIS ORB-OH-13003-APO Product guide

schmersal EX-AZM 415 operating instructions

schmersal

schmersal EX-AZM 415 operating instructions

AVS OUTSPIDER PA manual

AVS

AVS OUTSPIDER PA manual

Bradley S19-322 Installation

Bradley

Bradley S19-322 Installation

Pella Insynctive Product guide

Pella

Pella Insynctive Product guide

Alarmtech MC 740-E instruction manual

Alarmtech

Alarmtech MC 740-E instruction manual

DANLERS CBU-HBND IP66 quick guide

DANLERS

DANLERS CBU-HBND IP66 quick guide

Atsumi Electric NR30TS installation instructions

Atsumi Electric

Atsumi Electric NR30TS installation instructions

Mollet MSD-070 quick start guide

Mollet

Mollet MSD-070 quick start guide

Waters 432 Operator's guide

Waters

Waters 432 Operator's guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.