manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Schischek
  6. •
  7. Controllers
  8. •
  9. Schischek InMax-100 User manual

Schischek InMax-100 User manual

EXPLOSIONPROOF
InMax - ...
InMax - ... - F
InMax - ... - S
InMax - ... - SF
InMax - ... - CTM
InMax - ... - VAM
www.schischek.com
Schischek GmbH Germany, Muehlsteig 45, Gewerbegebiet Sued 5, 90579 Langenzenn, Tel. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail [email protected]
InMax-M-3P_en
V04 – 31-Oct-2018
Subject to change!
Compact. Easy installation. Universal. Cost effective. Safe.
Product views and applications
Description Highlights
Safety damper Ball valve Throttle valve
Electrical rotary actuators for use in safe areas
On-off / 3-pos. control mode, 24…240 VAC/DC, 95° angle of rotation incl. 5° pretension
50 / 75 – 100 – 150 Nm without and 30 – 50 – 60 Nm with safety operation (spring return)
Type Torque Supply Motor running time Spring return Control mode Feedback Wiring diagram
InMax- 50.75 50 / 75 Nm 24...240 VAC/DC 40 / 60 / 90 / 120 / 150 s/90° – On-off, 3-pos. – SB 1.0
InMax- 100 100 Nm 24...240 VAC/DC 40 / 60 / 90 / 120 / 150 s/90° – On-off, 3-pos. – SB 1.0
InMax- 150 150 Nm 24...240 VAC/DC 40 / 60 / 90 / 120 s/90° – On-off, 3-pos. – SB 1.0
InMax- 30 - F 30 Nm 24...240 VAC/DC 40 / 60 / 90 / 120 / 150 s/90° ~ 20 s/90° On-off, 3-pos. – SB 2.2/2.3
InMax- 50 - F 50 Nm 24...240 VAC/DC 40 / 60 / 90 / 120 / 150 s/90° ~ 20 s/90° On-off, 3-pos. – SB 2.2/2.3
InMax- 60 - F 60 Nm 24...240 VAC/DC 40 / 60 / 90 / 120 s/90° ~ 20 s/90° On-off, 3-pos. – SB 2.2/2.3
InMax- ... - S/SF Types as above with 2 integrated, potential free auxiliary switches, 5° and 85° angle of rotation 2 × aux. switches SB 3.0
InMax- ... - CTM Types as above with aluminium housing and seawater resistant coating (cable glands brass nickel-plated)
InMax- ... - VAM Types as above with stainless steel housing for aggressive ambient (cable glands brass nickel-plated)
InMax ¼ turn actuators – size M
►Industrial use
►Universal supply unit from 24…240 VAC/DC
►Different motor running times 40–60– 90–120–150 s/90°, adjustable on site
►Spring return running time ~ 20 s/ 90°
►On-off and 3-pos. control with or without spring return function
►30– 50–60–75–100–150 Nm actuators in the same housing size
►100 % overload protected
►Compact design and small dimension (L × W × H ~ 288 × 149 × 116 mm)
►Direct coupling to the damper shaft with double square connection 16 × 16 mm
►95° angle of rotation inclusive 5° pretension
►Robust aluminium housing (optional with seawater resistant coating)
or in stainless steel
►IP67 protection
►Simple manual override included + preparation for comfortable manual override
►Gear made of stainless steel and sinter metal
►Weight only ~ 9,5 kg
►Integrated heater for ambient temperatures down to −40 °C
►Integrated safety temperature sensor
►Integrated equipment for manual adjustment (push button, lamp, switch)
►Preparation for adaptable and adjustable auxiliary switches type ...Switch
►Wide range of accessories
The InMax actuators are a revolution for safety, control and shut-off
dampers, ball valves, throttle valves and other motorized applications
for HVAC systems in chemical, pharmaceutical, industrial and
offshore/onshore plants.
IP67 protection, small dimensions, only 9,5 kg weight, universal functions
and technical data, an integrated heater and an optional stainless steel
housing guarantee safe operation even under difficult environmental
conditions. High quality brushless motors guarantee long life.
All actuators are programmable and adjustable on site. Special tools or
equipment are not required. Motor running times and torques are selectable
or adjustable on site. The integrated universal power supply is self
adaptable to input voltages in the range of 24...240 VAC/DC. The actuators
are 100 % overload protected.
...Max-...F actuators are equipped with spring return fail safe function.
Standard shaft connection is a double square direct coupling with
16 × 16 mm.
Different accessories are available to adapt auxiliary switches, terminal
boxes or adaptions for ball valves and throttle valves and other armatures.
1 / 4
EXPLOSIONPROOF
www.schischek.com
Schischek GmbH Germany, Muehlsteig 45, Gewerbegebiet Sued 5, 90579 Langenzenn, Tel. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail [email protected]
InMax-M-3P_en
V04 – 31-Oct-2018
InMax-... InMax-...-F InMax-...-S InMax-...-SF
Special option ... -CTM ... -VAM
Approbations Special solutions and accessories
Technical data InMax- 50.75 InMax- 100 InMax- 150 InMax- 30 -F InMax- 50 -F InMax- 60-F
Torque motor (min.) 50 / 75 Nm selectable 100 Nm 150 Nm 30 Nm 50 Nm 60 Nm
Torque spring (F) – – – min. 30 Nm min. 50 Nm min. 60 Nm
Torque blockade In blockade and end positions torques are higher than above specified torques for motor and spring.
Dimensioning of external load Upon spring return the external load should be max. 80 % of torque spring (F), but min. 10 Nm
Supply voltage / frequency 24...240 VAC/DC ± 10 %, self adaptable, frequency 50...60 Hz ± 20 %
Power consumption max. starting currents see Extra information (in acc. with voltage, I start >> I rated ), approx. 5 W holding power, approx. 16 W for heater
Protection class Class I (grounded)
Angle of rotation and indication 95° incl. ~ 5° pretension, mechanical value indication
Working direction Selectable by left/right mounting to the damper/valve shaft
Motor running times [s/90°] 40/60/90/120/150 40/60/90/120/150 40/60/90/120 40/60/90/120/150 40/60/90/120/150 40 / 60 / 90 / 120
Motor Brushless DC motor
Control mode On-off and 3-pos. in acc. with wiring, selectable on site
Spring return (F) – – –spring return upon voltage interruption
Spring return response time – – –up to 1 sec. after voltage interruption
Spring return running time (F) – – –~ 20 s/90°
Safety operations at 20 sec. (F) – – –min. 10,000 acc. to construction of damper and ambient
Auxiliary switches ...-S, ...-SF 2 integrated auxiliary switches, switching at 5° and 85° angle of rotation, potential free. Grid fuse-protection is recommended!
Umax/ Imax AC = 250 V/5 A; Umin AC/DC = 5 V; After one-time operation with U > 24 V AC/DC or I > 100 mA: Umin AC/DC = 12 V
Umax/ Imax DC = 48 V/1 A; Imin AC/DC = 5 mA; Imin AC/DC = 100 mA
Axle of the actuator Double square 16 × 16 mm, direct coupling, 100 % overload protected
Electrical connection Cable ~ 1 m, wire cross section 0.5 mm², equipotential bonding 4 mm². Connections require a terminal box!
Diameter of cable ~ Ø 7.1 mm ~ Ø 7.1 mm ~ Ø 7.1 mm ~ Ø 7.4 mm ~ Ø 7.4 mm ~ Ø 7.4 mm
2 cables in the versions ...-S and ...-SF (~ Ø ... + 7.4 mm)
Cable gland M16 × 1.5 mm
Manual override Use delivered socket wrench, max. 4 Nm
Heater Integrated, controlled heater for ambient temperature down to −40 °C
Housing material Aluminium die-cast housing, coated. Optional with seawater resistant coating (...-CTM) or stainless steel housing,
№1.4581 / UNS-J92900 / similar AISI 316Nb (...-VAM)
Dimensions (L × W × H) ~ 288 × 149 × 116 mm, for diagrams see Extra information
Weight ~ 9.5 kg aluminium housing, stainless steel ~ 15 kg
Ambients Storage temperature −40…+70 °C, working temperature −40…+50 °C
Humidity 0...90 % rH, non condensing
Operation mode 80 % of ED are permitted (ED = duty cycle)
Maintenance Maintenance free relative to function, maintenance must comply with regional standards, rules and regulations
Wiring diagrams SB 1.0 SB 1.0 SB 1.0 SB 2.2 / 2.3 SB 2.2 / 2.3 SB 2.2 / 2.3
Scope of delivery Actuator, 4 screws M8 × 140 mm, 4 nuts M8, Allen key for simple manual override
Parameter at delivery 50 Nm, 90 s/90° 100 Nm, 90 s/90° 150 Nm, 90 s/90° 30 Nm, 90 s/90° 50 Nm, 90 s/90° 60 Nm, 90 s/90°
...-CTM Types in aluminium housing with seawater resistant coating,
parts nickel-plated
...-VAM Types in stainless steel housing, parts nickel-plated
InBox-... Terminal boxes
MKK-M Mounting bracket for boxes type ...Box-... directly on actuator
InSwitch 2 external aux. switches, adjustable
HV-MK Comfortable manual override for ...Max actuators size M
AR-16-xx Reduction part for 16 mm square connection to 14 or 12 mm shafts
Kit-S8 Cable glands nickel-plated
Adaptions for dampers and valves on request
InMax-...-S3 Ambient temperature up to +60 °C, 110...240 VAC/DC, 25 % ED
InMax-50-SF-S9 Without thermal fuse, aux. switches at 0° and 80° angle of rotation
CE identification CE
EMC directive 2014/30/EU
Low voltage directive 2014/35/EU
Enclosure protection IP67 in acc. with EN 60529
2 / 4
EXPLOSIONPROOF
InMax- 50.75 ►
InMax- 100 ►
InMax- 150 ►
InMax- 30 -F ►
InMax- 50 -F ►
InMax- 60 -F ►
50 Nm
100 Nm
150 Nm
30 Nm
50 Nm
60 Nm
▼
75 Nm
▼
40 s /90° ►
60 s /90° ►
90 s /90° ►
120 s /90° ►
150 s /90° ►
00
01
02
03
04
05
06
07
08
09
InBox
a
a
a
b
b
b
+
~
+
~
+
~
+
~
−
~
−
~
−
~
−
~
PE
PE
PE
PE
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
PA
PAPA
PA
1 42 3 5 6
< 5° > 85°
U < 90 V AC/DC 2 AT 10 AT
U > 90 V AC/DC 5 AT 10 AT
S
T
www.schischek.com
Schischek GmbH Germany, Muehlsteig 45, Gewerbegebiet Sued 5, 90579 Langenzenn, Tel. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail [email protected]
InMax-M-3P_en
V04 – 31-Oct-2018
InMax-... InMax-...-F InMax-...-S InMax-...-SF
Special option ... -CTM ... -VAM
Electrical connection Parameters, adjustments and failure indication
Parameter selection
Functions, adjustments and parameters
Type
Running times Position of switch (S)
Torques
Example:
InMax-50.75
Requested parameter:
Torque 75 Nm
Motor running time 90 s/90°
Result:
Switch position 07
All actuators are equipped with a universal supply unit working at a voltage range from
24...240 VAC/DC. The supply unit is self adjusting to the connected voltage!
The safety operation of the spring return function works if the supply voltage is cut.
For electrical connection a terminal box is required (e.g. InBox).
An over-current protection fuse < 10 A has to be provided by installer.
Note: the initial current is appr. 2 A for 1 second.
Integrated auxiliary switches signal the rotation angle’s position. U
min
and I
min
change once
the switches were operated with higher voltage or current.
Installation
Supply *
24...240 VAC/DC ± 10 %
* electrical wiring see diagrams
On-off / 3-pos. SB 2.2
On-off / 3-pos. SB 1.0
On-off (1 wire) SB 2.3
Wiring of integrated auxiliary switches SB 3.0
Wiring diagram InMax- ... (without spring return)
Wiring diagram InMax- ... -F (with spring return)
Wiring diagram InMax- ... -S and ... -SF
Attention!
At 1-wire control
mode the heater
does not work in
case of open contact.
Wiring of actuator acc. to type and
application see diagrams above
Wiring of the integrated, potential free
auxiliary switches
24...240 VAC/DC
24...240 VAC/DC
24...240 VAC/DC
24...240 VAC/DC
Attention
During commissioning apply
a self adjustment drive.
Regard duty cycle at
motor running times!
Never use spring return
actuators without external load.
Auxiliary switches *
see Technical data
Integrated auxiliary switches,
Grid fuse-protection recommended.
min. max.
A) Self adjustment of angle of rotation
Turn switch (S) to position 02 (low torque) or 07 (high torque). Press button (T) for
a minimum of 3 seconds. The actuator drives to both end positions and detects the
blocking positions. The LED flashes GREEN during adjustment.
The adjustment takes about 180 seconds (90 sec. “On”, 90 sec. “Off”).
B) Selecting motor running time and torque
Adjust parameters only if actuator is in idle state or without applied potential.
Turn switch (S) to the position required for the intended operation acc. to table
above. The selected parameters will be carried out at the actuator’s next operation.
C) Additional information for control in 3-pos. operation
a closed, b open = direction I a and b closed = motor doesn’t work
b closed, a open = direction II a and b open = motor doesn’t work
The rotation direction (I and II) depends on left/right mounting of the actuator to the
damper. To reverse the rotation direction (by motor) exchange the electrical wiring
of terminal 3 and 4.
▪ Do not open the cover when circuits are live
▪ Connect potential earth
▪ Close all openings to ensure enclosure protection
▪ Clean only with damp cloth, avoid dust accumulation
Switch – Push button – Lamp
for adjustment
(behind the blanking plug)
10-position switch (S)
3-colour LED
Push button (T)
3 / 4
EXPLOSIONPROOF
www.schischek.com
Schischek GmbH Germany, Muehlsteig 45, Gewerbegebiet Sued 5, 90579 Langenzenn, Tel. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail [email protected]
InMax-M-3P_en
V04 – 31-Oct-2018
InMax-... InMax-...-F InMax-...-S InMax-...-SF
Special option ... -CTM ... -VAM
Important information for installation and operation
Accessory InBox – adaptable terminal boxAccessory InSwitch – adaptable auxiliary switch
For electrical connection of ...Max actuators a terminal
box is required.
InBoxes are appropriate terminal boxes and placed at the
disposal. To adapt the ...Box directly to the actuator hous-
ing a mounting bracket type MKK-M is required.
InBox- 3P for ...Max-... and ...Max-...-F
InBox- Y/S for ...Max-...-S and ...-SF with integrated
auxiliary switches
For an end or inclined position indication it is possible to
retrofit external, adjustable auxiliary switches type InSwitch.
The switch housing is mounted directly to the actuator and
the switches are linked to the actuator’s square connector.
The switches deliver a potential free output and can be
adjusted separately. They are connected by the included
cable tail.
Extra information (see additional data sheet)
Additional technical information, dimensions, installation instruction, illustration
and failure indication
A. Installation, commissioning, maintenance
All national and international standards, rules and regulations must be complied with.
Apparatus must be installed in accordance with manufacturer instructions. If the equipment
is used in a manner not specified by the manufacturer, the safety protection provided by
the equipment may be impaired.
For electrical connection a terminal box is required (e.g. InBox-...).
Attention: If the actuator is put out of operation all rules and regulationsmust be applied.
You have to cut the supply voltage before opening the terminal box!
The cablesof the actuator must be installed in a fixed position and protected against
mechanical and thermical damage. Connect potential earth. Avoid temperature transfer
from armature to actuator! Close all openings with min. IP67.
For outdoor installation a protective weather shield against sun, rain and snow should be
applied to the actuator as well as a constant supply at terminal 1 and 2 for the integrated
heater. During commissioning apply a self adjustment drive.
Actuators are maintenance free. An annual inspection is recommended. Actuators must
not be opened by the customer.
B. Manual override
Manual override only if supply voltage is cut. Use delivered socket wrench with slow
motions, usage can be tight.
Attention: Releasing or letting go the Allen key too fast at manual operating actuators
with spring return causes risk of injury!
C. Shaft connection, selection of running time
Actuators are equipped with a direct coupling double square shaft connection of 16 × 16 mm.
The housing of the actuator is axially symmetrically built to select Open-close direction
of the spring return function by left-right mounting. Using the 10-position switch different
motor running times and spring return running times can be selected on site in acc. to
the actuator type.
D. 3-position control mode
...Max actuators are in the best way suitable for the 3-pos. operation. To protect such
elements as gears and mounting elements against harmful influences like minimum
pulse time, ...Max actuators are protected via internal electronics. It ignores impulses
< 0,5 s, the cyclic duration must be min. 0,5 s. At changing direction the pause is 1 s.
E. Spring return
Spring return function works only if the supply voltage for terminal 1 or 2 is cut. In the
event of an electrical interruption, the spring returns to its end position even if supply
voltage is available again during return function. Thereafter operation will continue.
F. Operation at ambient temperatures below −20 °C
All actuators are equipped with a regulated integrated heating device designed for
employments down to −40 °C ambient temperature. The heater will be supplied automatically
by connecting the constant voltage supply on the clamps 1 and 2.
1. After mounting the actuator must bei immediately electrically connected.
2. The heater switches on automatically when actuator reaches internally −20 °C. It
heats up the actuator to a proper working temperature, then heater switches off
automatically. Actuator will not run during heating process.
3. The adjustment options are only ensured after this heating up period.
G. Excess temperatures
All actuators are protected against excess temperature.The internal thermostat works
as a maximum limiter and, in the event of failure at incorrect temperatures, shuts off the
actuator irreversible. An upstream connected temperature sensor stops the actuator
before reaching its max. temperature. This safety feature is reversible, after cooling down
the actuator is completely functional again. In this case the failure must be eliminated
immediately on site!
H. Synchron mode
Do not connect several actuators to one shaft or link mechanically together.
I. Mechanical protection
Actuators must be operated with a minimum external load.
After installing the actuator to the damper/armature a self adjustment drive has to be
performed in order to protect the damper/armature against mechanical overload.
During operation the actuator reduces briefly its speed (motor power) before reaching
the end position for a “gentle” blockade/stop.
J. Loss of voltage
In switch position 00, 01 and 05, 06 (motor running times 40 sec. and 60 sec.) and after
interrupted voltage the actuator (types 50.75, 100 and 150 and ...-S) moves in OFF
position then the actuators works regarding control signal.
4 / 4

This manual suits for next models

29

Other Schischek Controllers manuals

Schischek InMax CTM Series User manual

Schischek

Schischek InMax CTM Series User manual

Schischek EXV-8 Series User manual

Schischek

Schischek EXV-8 Series User manual

Schischek RedMax F1 Series User manual

Schischek

Schischek RedMax F1 Series User manual

Schischek InMax-8-F1 User manual

Schischek

Schischek InMax-8-F1 User manual

Schischek ExMax-50.75 Owner's manual

Schischek

Schischek ExMax-50.75 Owner's manual

Schischek RedMax S Series User manual

Schischek

Schischek RedMax S Series User manual

Schischek ExMax F3 Series User manual

Schischek

Schischek ExMax F3 Series User manual

Schischek ExMax CTS Series User manual

Schischek

Schischek ExMax CTS Series User manual

Schischek RedMax CTM Series User manual

Schischek

Schischek RedMax CTM Series User manual

Schischek RedMax-30-BF User manual

Schischek

Schischek RedMax-30-BF User manual

Schischek ExMax CTM Series User manual

Schischek

Schischek ExMax CTM Series User manual

Schischek ExMax CTM Series User manual

Schischek

Schischek ExMax CTM Series User manual

Schischek ExMax Series Quick start guide

Schischek

Schischek ExMax Series Quick start guide

Schischek InMax Series User manual

Schischek

Schischek InMax Series User manual

Schischek ExMax BF User manual

Schischek

Schischek ExMax BF User manual

Schischek ExReg-V CT Series User manual

Schischek

Schischek ExReg-V CT Series User manual

Schischek InMax CTM Series User manual

Schischek

Schischek InMax CTM Series User manual

Schischek ExMax CY Series User manual

Schischek

Schischek ExMax CY Series User manual

Schischek Redmax Series Quick start guide

Schischek

Schischek Redmax Series Quick start guide

Schischek ExMax User manual

Schischek

Schischek ExMax User manual

Schischek ExMax Series User manual

Schischek

Schischek ExMax Series User manual

Schischek InMax SF3 Series User manual

Schischek

Schischek InMax SF3 Series User manual

Schischek RedMax BF-VA Series User manual

Schischek

Schischek RedMax BF-VA Series User manual

Schischek RedMax-8-F1 User manual

Schischek

Schischek RedMax-8-F1 User manual

Popular Controllers manuals by other brands

Missouri Wind and Solar 200ECCDIGSSR quick start guide

Missouri Wind and Solar

Missouri Wind and Solar 200ECCDIGSSR quick start guide

Dadam micro ABC-2 Series user manual

Dadam micro

Dadam micro ABC-2 Series user manual

Beckhoff EP7402-0057 manual

Beckhoff

Beckhoff EP7402-0057 manual

JARDIBRIC DripPump PP16 instructions

JARDIBRIC

JARDIBRIC DripPump PP16 instructions

SMC Networks LEL25M Operation manual

SMC Networks

SMC Networks LEL25M Operation manual

Kelly KLS7212N user manual

Kelly

Kelly KLS7212N user manual

NORAUTO 2207763 instruction manual

NORAUTO

NORAUTO 2207763 instruction manual

SDJ SG FASTER1224 user manual

SDJ

SDJ SG FASTER1224 user manual

Trikdis GV17 installation manual

Trikdis

Trikdis GV17 installation manual

Switchmate Home SimplySmartHome Secure Quick start guides

Switchmate Home

Switchmate Home SimplySmartHome Secure Quick start guides

Bowens XMTR user guide

Bowens

Bowens XMTR user guide

Bard MV4000 SERIES Installation & parts manual

Bard

Bard MV4000 SERIES Installation & parts manual

GOK ODR Assembly and operating manual

GOK

GOK ODR Assembly and operating manual

STIEBEL ELTRON FEB Manual, operation and installation

STIEBEL ELTRON

STIEBEL ELTRON FEB Manual, operation and installation

Gira G1 installation guide

Gira

Gira G1 installation guide

Hall Research Technologies VSA-31-IP manual

Hall Research Technologies

Hall Research Technologies VSA-31-IP manual

National Instruments PCI-7354 Getting started

National Instruments

National Instruments PCI-7354 Getting started

VALPES ER35 Installation and operation manual

VALPES

VALPES ER35 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.