ShowPro PLUTO 2000 User manual

PLUTO 2000
USER MANUAL
LEDMOV530

1
301.5
293
217
100
374.7
Electrical
Voltage:100V-240V~,50/60Hz◆
Max Power:300W◆
Size:375x302x251mm◆
Weight:9.3kg◆
1 PRODUCT SPECIFICATIONS
1.1 PRODUCT SPECIFICATIONS
1.2 PRODUCT FEATURES
PLUTO 2000XE
SS646

21
12
13
179
STROBE
NO FUNCTION
STROBE FROM (SLOD TO FAST ,0-25Hz)
NO FUNCTION
LIGHTNING STROBE
NO FUNCTION
RANDOM SROBE
ZOOM
14
CONTROL
NO FUNCTION
PAN/TILT BLACK ACTIVATED
PAN/TILT BLACK DEACTIVATED
FAN SLOW
FAN NORMAL
FAN FAST
FAN AUTO
AUTO1
AUTO2
CUSTOM
TEST
RESET
NO FUNCTION
DIM0
DIM1
DIM2
DIM3
DIM4
NO FUNCTION
1.3 SAFETY WARNING
IMPORTANT:
●This product must be installed by a qualified professional.
●All maintenance must be carried out by a qualified electrician.
●A minimum distance of 0.5m must be maintained between the equipment
and a combustible surface.
●The product must always be operated in a well ventilated area.
●DO NOT stare directly into the LED light source.
●Always disconnect the power before carrying out any maintenance.
●The earth must always be connected to the ground.
●Ensure that all parts of the equipment are kept clean and free of dust.
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
Caution, risk of electric shock
The light source contained in this luminaire shall only be replaced
by the manufacturer or his service agent or a similar qualified person.
IMPORTANT SAFETY NOTE!!
Always use a safety cable when installing this unit!!
Be sure that the safety cable is connected to a solid load-bearing structure.
Clamp
Safety cable
Bracket
2.1 MOUNTING:
2 INSTALLATION
●The fixture can be mounted in any position.
●Always ensure that mounting surface can withstand 10 times the weight of the
fixture.
●Always use a safety cable when mounting the fixture in any elevated position.
2

320
11
static 16
static 17
static 18
static 19
static 20
static 21
static 22
static 23
static 24
static 25
static 26
static 27
static 28
static 29
black
static ALL
RING1 slow-->fast
RING2A slow-->fast
RING2B slow-->fast
RING2C slow-->fast
RING3A slow-->fast
RING3B slow-->fast
RING3C slow-->fast
RING3D slow-->fast
RING3E slow-->fast
RING4 slow-->fast
RING5 slow-->fast
GINR6 slow-->fast
1
2
3
4
5
6
7
1,2,3
1,4,5
1,6,7
1,2,5
1,3,6
1,4,7
3,5,7
5,6,7
1,3,5,7
1,5,6,7
1,2,4,5,7
1,2,3,5,6
1,3,4,6,7
2,3,4,5,6,7
DARK
BRIGHT
(2)-(3)-(4)-(5)-(6)-(7 )
(2,3)-(4,5)-(6,7 )
(2,5)-(3,6)-(4,7 )
(1,2)-(1,3)-(1,4)-(1,5)-(1,6)-(1,7 )
(2,3,4)-(5,6,7 )
(1,2,3)-(1,4,5)-(1,6,7 )
(1,2,5)-(1,3,6)-(1,4,7 )
(2,5,7)-(1,4,6 )
(2,3,4)-(3,4,5)-(4,5,6)-(5,6,7)-(6,7,2)-(7,2,3 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7,2 )
(1)-(2,3,4,5,6,7 )
SINGLE POINT CONTROL FUNCTION
CHANNEL FUNCTIONVALUE
To identify up, middle and down by head which after the fixture electrify & reset
PLUTO 2000XE
SS646
2.2 FUSE REPLACEMENT
SAFTY CAP
FUSE
● Remove the safety cap by a screwdriver.
etch the old fuse from safety cap.● F
nstall a new fuse. ● I
nstall the safety cap.● I
● 220~240V: 6 units may be connected in series
● 110~120V: 3 units may be connected in series
2.3 POWER CONNECTIONS
Note:
If the signal cable is over 60m between the DMX512 controller and fixture
or beween two fixtures, then a DMX signal amplifier is needed as well.
3.1 DISPLAY OPERATION
3 DISPLAY PANEL OPERATION
Up
Menu
Enter into
Roll
Down
(Start display screen when press 3 seconds)

4
19
1
2
3
4
5
6
PAN
PAN FINE
TITL
TITL FINE
PT SPEED
CYAN
MAGENT
YELLOW
DIMMER
7
8
9
10
11
A SINGLE POINT
NO FUNCTION
static 1
static 2
static 3
static 4
static 5
static 6
static 7
static 8
static 9
static 10
static 11
static 12
static 13
static 14
static 15
1
2
3
4
5
6
7
2,3
4,5
6,7
2,5
3,6
4,7
2,3,4
5,6,7
MARCOS
NO FUNCTION
RED 100% / GREEN UP / BLUE 0%
RED DOWN / GREEN 100% / BLUE 0%
RED 0% / GREEN 100% / BLUE UP
RED 0% / GREEN DOWN / BLUE 100%
RED UP / GREEN 0% / BLUE 100%
RED 100% /GREEN 0%/BLUE DOWN
RED 100%/GREEN UP/BLUE UP
RED DOWN/GREEN DOWN/BLUE 100%
ALL LED AT FULL OUTPUT
2700K
3200K
4200K
5600K
6500K
8000K
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
MENU
ADDRESS
HSIC
PERSON
001-512
PERSON1
PERSON2
FANS
PERFORM
SLOW
NORMAL
FAST
AUTO
BLACKOUT
OFF
ON
DIMMER
DIM4
DIM3
DIM2
DIM1
OFF
CMY
PAN/TILT
PAN INVERT
NORMAL
INVERT
TITL INVERT
NORMAL
INVERT
PT SPEED
FAST
SLOW
COLOR
UC
RGB to W
OFF
PIXEL
PT RANGE
P.START
P.END
T.START
T.END
USE
0-255
0-255
0-255
0-255
NO
YES
DMX ERROR
SAVE
BLACK
DMX RESET
DMX
DISPLAY
DISPLAY ON
SHORT
LONG
DISPLAY LOCK
OFF
ON
YES/NO
YES/NO
FULL POWER CCT
3200K
4200K
5600K
10000K
NORMAL
3.2 MENU MAP
PWM
1200Hz
2000Hz
2400Hz
6000Hz
25000Hz
SETTING
SETTINGS LOCK
OFF
ON
UPLOAD
LOAD PARA
LOAD EDIT
YES
NO
YES
NO
SINGLE POINT
CONTROL FUNCTION

518
20
CONTROL
NO FUNCTION
PAN/TILT BLACK ACTIVATED
PAN/TILT BLACK DEACTIVATED
FAN SLOW
FAN NORMAL
FAN FAST
FAN AUTO
AUTO1
AUTO2
CUSTOM
TEST
RESET
NO FUNCTION
DIM0
DIM1
DIM2
DIM3
DIM4
NO FUNCTION
18
19
179
STROBE
NO FUNCTION
STROBE FROM (SLOD TO FAST ,0-25Hz)
NO FUNCTION
LIGHTNING STROBE
NO FUNCTION
RANDOM SROBE
ZOOM
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
STAND ALONE
RUN
DMX512
ARTNET
ARTNET2DMX
AUTO1
AUTO2
CUSTOM
EDIT
PAN
TITL
RED
GREEN
BLUE
WHTIE
DIMMER
STROBE
TIME
USE
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-25
0-255
YES
INFO
SYSTEM ERROR
TEMPERATURE
VERSION
MANUAL
ALL RESET
YES
PT RESET
SERVICE
CALIB.C 2700K
4200K
5600K
6500K
8000K
3200K
ZOOM
0-255
RGBtoW RED
GREEN
BLUE
0-255
0-255
0-255
STEP(01-50)
V01
NO
YES
NO
WDMX
SERVECE LOCK
OFF
ON
RECOVERY *****
WDMXHIDE
YES
NO
WDMX POWER
OFF
ON
NETWORK
Net SWITCH
OFF
ON
IP MODE
DEFAUL IP
CUSTOM IP
CUSTOM IP EDIT
XX.XX.XX.XX
ADDR XXX
UNIVERS
WDMX RESET
YES
NO
TEST
SLAVE
NETWORK PARA
RDM UID
LABEL
0X388Axxxxxxxx
PLUTO 2000XE
NO
RED
GREEN
BLUE
0-255
0-255
0-255
WHTIE
0-255
CALR ****

6
17
static 16
static 17
static 18
static 19
static 20
static 21
static 22
static 23
static 24
static 25
static 26
static 27
static 28
static 29
black
static ALL
RING1 slow-->fast
RING2A slow-->fast
RING2B slow-->fast
RING2C slow-->fast
RING3A slow-->fast
RING3B slow-->fast
RING3C slow-->fast
RING3D slow-->fast
RING3E slow-->fast
RING4 slow-->fast
RING5 slow-->fast
GINR6 slow-->fast
1
2
3
4
5
6
7
static 8
static 9
static 10
static 11
static 12
static 13
static 14
static 15
2,3
4,5
6,7
2,5
3,6
4,7
2,3,4
5,6,7
1,2,3
1,4,5
1,6,7
1,2,5
1,3,6
1,4,7
3,5,7
5,6,7
1,3,5,7
1,5,6,7
1,2,4,5,7
1,2,3,5,6
1,3,4,6,7
2,3,4,5,6,7
DARK
BRIGHT
(2)-(3)-(4)-(5)-(6)-(7 )
(2,3)-(4,5)-(6,7 )
(2,5)-(3,6)-(4,7 )
(1,2)-(1,3)-(1,4)-(1,5)-(1,6)-(1,7 )
(2,3,4)-(5,6,7 )
(1,2,3)-(1,4,5)-(1,6,7 )
(1,2,5)-(1,3,6)-(1,4,7 )
(2,5,7)-(1,4,6 )
(2,3,4)-(3,4,5)-(4,5,6)-(5,6,7)-(6,7,2)-(7,2,3 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7,2 )
(1)-(2,3,4,5,6,7 )
17
CHANNEL FUNCTIONVALUE
To identify up, middle and down by head
which after the fixture electrify & reset
PLUTO 2000XE
SS646
FANS
PERFORM
SLOW
NORMAL
FAST
AUTO
BLACKOUT
OFF
ON
DIMMER
DIM4
DIM3
DIM2
DIM1
OFF
PAN/TILT
PAN INVERT
NORMAL
INVERT
TITL INVERT
NORMAL
INVERT
PT SPEED
FAST
SLOW
COLOR
UC
RGB to W
OFF
PT RANGE
P.START
P.END
T.START
T.END
USE
0-255
0-255
0-255
0-255
NO
YES
FULL POWER CCT
3200K
4200K
5600K
10000K
NORMAL
MENU
HSIC
PERSON
PERSON1
PERSON2
CMY
PIXEL
MENU
●Enter the【PERSON】mode to select DMX mode:【 】HSIC ,
【 】 【 】 【 】 【PIXEL】PERSON1 ,PERSON2 ,CMY , ,
3.4 PERSONALITY
ADDRESS
001-512
MENU
3.3 DMX512 SETTINGS
●Enter the【DMX】mode to set the DMX ADDRESS.
3.5 PERFORM
DMX ERROR
SAVE
BLACK
PWM
1200Hz
2000Hz
2400Hz
6000Hz
25000Hz
SINGLE POINT CONTROL FUNCTION

716
1
2
3
4
5
6
7
16
MARCOS
NO FUNCTION
RED 100% / GREEN UP / BLUE 0%
RED DOWN / GREEN 100% / BLUE 0%
RED 0% / GREEN 100% / BLUE UP
RED 0% / GREEN DOWN / BLUE 100%
RED UP / GREEN 0% / BLUE 100%
RED 100% /GREEN 0%/BLUE DOWN
RED 100%/GREEN UP/BLUE UP
RED DOWN/GREEN DOWN/BLUE 100%
ALL LED AT FULL OUTPUT
2700K
3200K
4200K
5600K
6500K
8000K
17
NO FUNCTION
static 1
static 2
static 3
static 4
static 5
static 6
static 7
8
9
10
11
12
13
14
PAN
PAN FINE
TITL
TITL FINE
PT SPEED
RED
RED FINE
GREEN
GREEN FINE
BLUE
BLUE FINE
WHTIE
WHTIE FINE
DIMMER
DIMMER FINE
15
1
2
3
4
5
6
7
A SINGLE POINT
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
DMX RESET
DMX
DISPLAY
DISPLAY ON
SHORT
LONG
YES/NO
YES/NO
MENU
SETTING
WDMX
SETTINGS LOCK
OFF
ON
SERVECE LOCK
OFF
ON
Recovery *****
WDMXHIDE
YES
NO
WDMX POWER
OFF
ON
NETWORK
Net SWITCH
OFF
ON
IP MODE
DEFAUL IP
CUSTOM IP
CUSTOM IP EDIT
XX.XX.XX.XX
ADDR XXX
UNIVERS
WDMX RESET
YES
NO
PERFORM
DISPLAY LOCK
OFF
ON
UPLOAD
LOAD PARA
LOAD EDIT
YES
NO
YES
NO
●【FANS】menu, select【Slow/Norm/Fast/Auto】as required fan speed.
●【PAN INVERT】menu, select 【NORM/INVERT】for normal/inverted control of
the PAN function
●【TILT INVERT】menu, select 【NORM/INVERT】for normal/inverted control of
the TILT function
●【PT SPEED】menu, select 【Slow/Fast】as required PAN/TILT movement
speed.
●【BLACKD】menu, select 【OFF】for immediate activation of PAN/TILT
blackout when selected using the control channel or 【ON】 for 3 second delay
before activation.
●【DIMMER】 menu for selection of 【DIM1/DIM2/DIM3/DIM4/OFF】 special
dimming curves
【 】 [ ] ● COLOR is for activate/unactivate the color calibration functions. When RGBtoW
is selected, on RGB = 255,255,255, the color is displayed as calibratedin
Service -- RGBtoW. When COLOR is set OFF , on RGB = 255,255,255, the [ ] [ ]
RGBvalues are not adjusted and the output is most powerful.When [UC] is selected,
the RGB output are adjusted to a standard preset universal color which balances
fixtures from different generations.
●FULL POWER CCT is the color temperature choose bottom, press UP/DOWN to 【 】
choose, under full power, <3200K>、<4200K>、<5600K> 、<10000K> can be chosen,
when choose <COLOR>, <3200K>、<4200K>、<5600K> 、<10000K>are not work, but
choose <NORMAL>.
●PWM is PWM reflesh rate bottom, press UP/DOWN to choose <1200Hz>、<2000Hz>、【 】
<2400Hz>、<6000Hz>、<25000Hz>
Note: with reflesh rate increased, gray rate of dimmer will be reduced
SINGLE POINT
CONTROL FUNCTION

●【DMXERROR】menu, select 【SAVE】to maintain last command in case of DMX
error or 【BLACK】for blackout
12
CONTROL
NO FUNCTION
PAN/TILT BLACK ACTIVATED
PAN/TILT BLACK DEACTIVATED
FAN SLOW
FAN NORMAL
FAN FAST
FAN AUTO
AUTO1
AUTO2
CUSTOM
TEST
RESET
NO FUNCTION
DIM0
DIM1
DIM2
DIM3
DIM4
NO FUNCTION
10
11
179
STROBE
NO FUNCTION
STROBE FROM (SLOD TO FAST ,0-25Hz)
NO FUNCTION
LIGHTNING STROBE
NO FUNCTION
RANDOM SROBE
ZOOM
15
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
●【UPLOAD】upload data setting, choose 【LOAD PARA】to upload data, choose
【NO】means do not upload data choose【YES】means upload data, choose
【LOAD EDIT】 to program, choose 【NO】means do not upload, choose 【YES】
means upload
●【DMXRESET】menu, select 【DMX】to allow remote reset using DMX controller or
【DISPLAY】for reset only available at on-fixture display
●【DISPLAY ON】menu, select 【LONG/SHORT/ 】for length of timeDISPLAY LOCK
for display backlight
●【SETTING】is a protect bottom,【 SETTINGS LOCK】is the menu lock bottom, choose
【OFF】means the menu lock bottom is off, choose 【ON】means the menu lock bottom
is on【RECOVERY】is the recover to default value.Press 【ENTER】to password
setting, press correct password 【UP+DOWN+UP+DOWN】,and press 【ENTER】,if
password is correct, display will show 【OK】,
●【NET SWTCH】is net switch, OFF adhere to 2.XX.XX.XX , ON adhere to 2.XX.XX.XX,
【IP MODE】 is IP mode setting, "DEFAULT IP" is default IP, CUSTOM IP is user IP,
【CUSTOM IP SET】is customer IP setting, 【UNIVERS】is data bulk setting, output
series 0-255
●【WDMX】setting , choose 【WDMX POWER】to turn on/off the DMX , choose 【OFF】
to turn off it . 【ON】to turn on it . Choose 【 WDMX RESET】to reset the DMX , choose
【NO】, then DMX will not reset , 【YES】, then DMX will reset
MENU
STAND ALONE
RUN
DMX512
ARTNET
ARTNET2DMX
AUTO1
AUTO2
CUSTOM
TEST
SLAVE
3.6 RUN
●Enter the【STAND ALONE】menu to select from
【DMX512/ARTNET/ARTNET2DMX/AUTO 1/AUTO 2/CUSTOM/TEST/SLAVE】
run modes
STAND ALONE
EDIT
PAN
TITL
RED
GREEN
BLUE
WHTIE
DIMMER
STROBE
ZOOM
TIME
USE
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-25
0-255
0-255
YES
STEP(01-50)
MENU
NO
3.7 EDIT
8

9
9
static 16
static 17
static 18
static 19
static 20
static 21
static 22
static 23
static 24
static 25
static 26
static 27
static 28
static 29
black
static ALL
RING1 slow-->fast
RING2A slow-->fast
RING2B slow-->fast
RING2C slow-->fast
RING3A slow-->fast
RING3B slow-->fast
RING3C slow-->fast
RING3D slow-->fast
RING3E slow-->fast
RING4 slow-->fast
RING5 slow-->fast
GINR6 slow-->fast
1
2
3
4
5
6
7
1,2,3
1,4,5
1,6,7
1,2,5
1,3,6
1,4,7
3,5,7
5,6,7
1,3,5,7
1,5,6,7
1,2,4,5,7
1,2,3,5,6
1,3,4,6,7
2,3,4,5,6,7
DARK
BRIGHT
(2)-(3)-(4)-(5)-(6)-(7 )
(2,3)-(4,5)-(6,7 )
(2,5)-(3,6)-(4,7 )
(1,2)-(1,3)-(1,4)-(1,5)-(1,6)-(1,7 )
(2,3,4)-(5,6,7 )
(1,2,3)-(1,4,5)-(1,6,7 )
(1,2,5)-(1,3,6)-(1,4,7 )
(2,5,7)-(1,4,6 )
(2,3,4)-(3,4,5)-(4,5,6)-(5,6,7)-(6,7,2)-(7,2,3 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7,2 )
(1)-(2,3,4,5,6,7 )
14
● Enter the【 EDIT 】mode to edit the custom programs by adjusting the
value of【PAN】 ,【TILT】 ,【RED】,【GREEN】,【BLUE】,
【WHITE】,【DIMMER】,【STROBE】,【ZOOM】,【 TIME】
● 【 USE】 【YES】Enter and select to run the steps user need.
Note: if user want to circulate the created steps, please set the last step s ‘
T as 0【ime】
For example, there are 3 steps, the setting should be like belowed:
Step 1 T = 4 = Yes【ime】 【 Use】
Step 2 T = 5 = Yes【ime】 【 Use】
Step 3 T = 0 = Yes【ime】 【 Use】
CHANNEL FUNCTIONVALUE
To identify up, middle and down by head which after the fixture electrify & reset
PLUTO 2000XE
SS646
MENU
INFO
SYSTEM ERROR
TEMPERATURE
VERSION
V01
NETWORK PARA
RDM UID
LABEL
0X388Axxxxxxxx
PLUTO 2000XE
3.8 INFO
● push 【OK】button into the information search mode in menu 【INFO】, push
【up/down】to choose item.
Choose 【SYSTEM ERROR】system data error .
Choose 【TEMPERATURE】LED working temperature
Choose 【 VERSION】 software version
Choose 【NETWORK PARA】check network specification
Choose 【RDM】check the fixture ID
Choose 【LABEL】check model name
MANUAL
ALL RESET
NO
YES
PT RESET
NO
YES
MENU
3.9 MANUAL
●Select【RESET】from the【MANUAL】menu
●【ALL RESET】menu, select【YES/NO】to carry out full fixture reset
●【PT RESET】menu, select【YES/NO】to carry out PAN/TILT reset
SINGLE POINT CONTROL FUNCTION

10
1
2
3
4
5
PAN
TITL
RED
GREEN
BLUE
WHITE
DIMMER
6
7
8
MARCOS
NO FUNCTION
RED 100% / GREEN UP / BLUE 0%
RED DOWN / GREEN 100% / BLUE 0%
RED 0% / GREEN 100% / BLUE UP
RED 0% / GREEN DOWN / BLUE 100%
RED UP / GREEN 0% / BLUE 100%
RED 100% /GREEN 0%/BLUE DOWN
RED 100%/GREEN UP/BLUE UP
RED DOWN/GREEN DOWN/BLUE 100%
ALL LED AT FULL OUTPUT
2700K
3200K
4200K
5600K
6500K
8000K
9
NO FUNCTION
static 1
static 2
static 3
static 4
static 5
static 6
static 7
static 8
static 9
static 10
static 11
static 12
static 13
static 14
static 15
1
2
3
4
5
6
7
2,3
4,5
6,7
2,5
3,6
4,7
2,3,4
5,6,7
13
A SINGLE POINT
●Press 【ENTER】to find 【CALR】CCT reset , press passcode (Up +Down+ Up +
Down) , then 【SUCCESS】will be shown
● Enter the 【CALIB】to select white color of different color temperature.
● There are 11 pre-programmed White colors plus RGB TO WHITE and can be edited
by using 【RED】, 【GREEN】, 【BLUE】& 【WHITE】.
● Enter the 【RGBtoW】to adjust the RGB parameter to make different
whites.
● When the new setting is activated, the DMX controller choose RGB
= 255,255,255 the white color will be made by the actual RGB values
on the .【RGBtoW】
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
SERVICE
CALIB.C 2700K
4200K
5600K
6500K
8000K
3200K
RGBtoW RED
GREEN
BLUE
0-255
0-255
0-255
RED
GREEN
BLUE
0-255
0-255
0-255
WHTIE
0-255
CALR ****
MENU
3.10 SERVICE
SINGLE POINT
CONTROL FUNCTION

11
1
2
3
4
11
5
PAN
PAN FINE
TITL
TITL FINE
PT SPEED
INTENSIYT
HUE
HUE FINE
SATURATION
10
CCT
NO FUNCTION
2700K
3200K
4200K
5600K
6500K
8000K
12
179
STROBE
NO FUNCTION
STROBE FROM (SLOD TO FAST ,0-25Hz)
NO FUNCTION
LIGHTNING STROBE
NO FUNCTION
RANDOM SROBE
ZOOM
6
7
8
9
13
CONTROL
NO FUNCTION
PAN/TILT BLACK ACTIVATED
PAN/TILT BLACK DEACTIVATED
FAN SLOW
FAN NORMAL
FAN FAST
FAN AUTO
AUTO1
AUTO2
CUSTOM
TEST
RESET
NO FUNCTION
DIM0
DIM1
DIM2
DIM3
DIM4
NO FUNCTION
12
● Note: This product have four DMX512 channel configuration:
【HSIC】,【PERSON1】,【PERSON2】,【CMY】,【PIXEL】.
4.1 CHANNEL ASSIGNMENT
4 USING A DMX512 CONTROLLER
CHANNEL FUNCTIONVALUE
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646

11
1
2
3
4
11
5
PAN
PAN FINE
TITL
TITL FINE
PT SPEED
INTENSIYT
HUE
HUE FINE
SATURATION
10
CCT
NO FUNCTION
2700K
3200K
4200K
5600K
6500K
8000K
12
179
STROBE
NO FUNCTION
STROBE FROM (SLOD TO FAST ,0-25Hz)
NO FUNCTION
LIGHTNING STROBE
NO FUNCTION
RANDOM SROBE
ZOOM
6
7
8
9
13
CONTROL
NO FUNCTION
PAN/TILT BLACK ACTIVATED
PAN/TILT BLACK DEACTIVATED
FAN SLOW
FAN NORMAL
FAN FAST
FAN AUTO
AUTO1
AUTO2
CUSTOM
TEST
RESET
NO FUNCTION
DIM0
DIM1
DIM2
DIM3
DIM4
NO FUNCTION
12
● Note: This product have four DMX512 channel configuration:
【HSIC】,【PERSON1】,【PERSON2】,【CMY】,【PIXEL】.
4.1 CHANNEL ASSIGNMENT
4 USING A DMX512 CONTROLLER
CHANNEL FUNCTIONVALUE
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646

10
1
2
3
4
5
PAN
TITL
RED
GREEN
BLUE
WHITE
DIMMER
6
7
8
MARCOS
NO FUNCTION
RED 100% / GREEN UP / BLUE 0%
RED DOWN / GREEN 100% / BLUE 0%
RED 0% / GREEN 100% / BLUE UP
RED 0% / GREEN DOWN / BLUE 100%
RED UP / GREEN 0% / BLUE 100%
RED 100% /GREEN 0%/BLUE DOWN
RED 100%/GREEN UP/BLUE UP
RED DOWN/GREEN DOWN/BLUE 100%
ALL LED AT FULL OUTPUT
2700K
3200K
4200K
5600K
6500K
8000K
9
NO FUNCTION
static 1
static 2
static 3
static 4
static 5
static 6
static 7
static 8
static 9
static 10
static 11
static 12
static 13
static 14
static 15
1
2
3
4
5
6
7
2,3
4,5
6,7
2,5
3,6
4,7
2,3,4
5,6,7
13
A SINGLE POINT
●Press 【ENTER】to find 【CALR】CCT reset , press passcode (Up +Down+ Up +
Down) , then 【SUCCESS】will be shown
● Enter the 【CALIB】to select white color of different color temperature.
● There are 11 pre-programmed White colors plus RGB TO WHITE and can be edited
by using 【RED】, 【GREEN】, 【BLUE】& 【WHITE】.
● Enter the 【RGBtoW】to adjust the RGB parameter to make different
whites.
● When the new setting is activated, the DMX controller choose RGB
= 255,255,255 the white color will be made by the actual RGB values
on the .【RGBtoW】
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
SERVICE
CALIB.C 2700K
4200K
5600K
6500K
8000K
3200K
RGBtoW RED
GREEN
BLUE
0-255
0-255
0-255
RED
GREEN
BLUE
0-255
0-255
0-255
WHTIE
0-255
CALR ****
MENU
3.10 SERVICE
SINGLE POINT
CONTROL FUNCTION

9
9
static 16
static 17
static 18
static 19
static 20
static 21
static 22
static 23
static 24
static 25
static 26
static 27
static 28
static 29
black
static ALL
RING1 slow-->fast
RING2A slow-->fast
RING2B slow-->fast
RING2C slow-->fast
RING3A slow-->fast
RING3B slow-->fast
RING3C slow-->fast
RING3D slow-->fast
RING3E slow-->fast
RING4 slow-->fast
RING5 slow-->fast
GINR6 slow-->fast
1
2
3
4
5
6
7
1,2,3
1,4,5
1,6,7
1,2,5
1,3,6
1,4,7
3,5,7
5,6,7
1,3,5,7
1,5,6,7
1,2,4,5,7
1,2,3,5,6
1,3,4,6,7
2,3,4,5,6,7
DARK
BRIGHT
(2)-(3)-(4)-(5)-(6)-(7 )
(2,3)-(4,5)-(6,7 )
(2,5)-(3,6)-(4,7 )
(1,2)-(1,3)-(1,4)-(1,5)-(1,6)-(1,7 )
(2,3,4)-(5,6,7 )
(1,2,3)-(1,4,5)-(1,6,7 )
(1,2,5)-(1,3,6)-(1,4,7 )
(2,5,7)-(1,4,6 )
(2,3,4)-(3,4,5)-(4,5,6)-(5,6,7)-(6,7,2)-(7,2,3 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7,2 )
(1)-(2,3,4,5,6,7 )
14
● Enter the【 EDIT 】mode to edit the custom programs by adjusting the
value of【PAN】 ,【TILT】 ,【RED】,【GREEN】,【BLUE】,
【WHITE】,【DIMMER】,【STROBE】,【ZOOM】,【 TIME】
● 【 USE】 【YES】Enter and select to run the steps user need.
Note: if user want to circulate the created steps, please set the last step s ‘
T as 0【ime】
For example, there are 3 steps, the setting should be like belowed:
Step 1 T = 4 = Yes【ime】 【 Use】
Step 2 T = 5 = Yes【ime】 【 Use】
Step 3 T = 0 = Yes【ime】 【 Use】
CHANNEL FUNCTIONVALUE
To identify up, middle and down by head which after the fixture electrify & reset
PLUTO 2000XE
SS646
MENU
INFO
SYSTEM ERROR
TEMPERATURE
VERSION
V01
NETWORK PARA
RDM UID
LABEL
0X388Axxxxxxxx
PLUTO 2000XE
3.8 INFO
● push 【OK】button into the information search mode in menu 【INFO】, push
【up/down】to choose item.
Choose 【SYSTEM ERROR】system data error .
Choose 【TEMPERATURE】LED working temperature
Choose 【 VERSION】 software version
Choose 【NETWORK PARA】check network specification
Choose 【RDM】check the fixture ID
Choose 【LABEL】check model name
MANUAL
ALL RESET
NO
YES
PT RESET
NO
YES
MENU
3.9 MANUAL
●Select【RESET】from the【MANUAL】menu
●【ALL RESET】menu, select【YES/NO】to carry out full fixture reset
●【PT RESET】menu, select【YES/NO】to carry out PAN/TILT reset
SINGLE POINT CONTROL FUNCTION

●【DMXERROR】menu, select 【SAVE】to maintain last command in case of DMX
error or 【BLACK】for blackout
12
CONTROL
NO FUNCTION
PAN/TILT BLACK ACTIVATED
PAN/TILT BLACK DEACTIVATED
FAN SLOW
FAN NORMAL
FAN FAST
FAN AUTO
AUTO1
AUTO2
CUSTOM
TEST
RESET
NO FUNCTION
DIM0
DIM1
DIM2
DIM3
DIM4
NO FUNCTION
10
11
179
STROBE
NO FUNCTION
STROBE FROM (SLOD TO FAST ,0-25Hz)
NO FUNCTION
LIGHTNING STROBE
NO FUNCTION
RANDOM SROBE
ZOOM
15
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
●【UPLOAD】upload data setting, choose 【LOAD PARA】to upload data, choose
【NO】means do not upload data choose【YES】means upload data, choose
【LOAD EDIT】 to program, choose 【NO】means do not upload, choose 【YES】
means upload
●【DMXRESET】menu, select 【DMX】to allow remote reset using DMX controller or
【DISPLAY】for reset only available at on-fixture display
●【DISPLAY ON】menu, select 【LONG/SHORT/ 】for length of timeDISPLAY LOCK
for display backlight
●【SETTING】is a protect bottom,【 SETTINGS LOCK】is the menu lock bottom, choose
【OFF】means the menu lock bottom is off, choose 【ON】means the menu lock bottom
is on【RECOVERY】is the recover to default value.Press 【ENTER】to password
setting, press correct password 【UP+DOWN+UP+DOWN】,and press 【ENTER】,if
password is correct, display will show 【OK】,
●【NET SWTCH】is net switch, OFF adhere to 2.XX.XX.XX , ON adhere to 2.XX.XX.XX,
【IP MODE】 is IP mode setting, "DEFAULT IP" is default IP, CUSTOM IP is user IP,
【CUSTOM IP SET】is customer IP setting, 【UNIVERS】is data bulk setting, output
series 0-255
●【WDMX】setting , choose 【WDMX POWER】to turn on/off the DMX , choose 【OFF】
to turn off it . 【ON】to turn on it . Choose 【 WDMX RESET】to reset the DMX , choose
【NO】, then DMX will not reset , 【YES】, then DMX will reset
MENU
STAND ALONE
RUN
DMX512
ARTNET
ARTNET2DMX
AUTO1
AUTO2
CUSTOM
TEST
SLAVE
3.6 RUN
●Enter the【STAND ALONE】menu to select from
【DMX512/ARTNET/ARTNET2DMX/AUTO 1/AUTO 2/CUSTOM/TEST/SLAVE】
run modes
STAND ALONE
EDIT
PAN
TITL
RED
GREEN
BLUE
WHTIE
DIMMER
STROBE
ZOOM
TIME
USE
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-25
0-255
0-255
YES
STEP(01-50)
MENU
NO
3.7 EDIT
8

716
1
2
3
4
5
6
7
16
MARCOS
NO FUNCTION
RED 100% / GREEN UP / BLUE 0%
RED DOWN / GREEN 100% / BLUE 0%
RED 0% / GREEN 100% / BLUE UP
RED 0% / GREEN DOWN / BLUE 100%
RED UP / GREEN 0% / BLUE 100%
RED 100% /GREEN 0%/BLUE DOWN
RED 100%/GREEN UP/BLUE UP
RED DOWN/GREEN DOWN/BLUE 100%
ALL LED AT FULL OUTPUT
2700K
3200K
4200K
5600K
6500K
8000K
17
NO FUNCTION
static 1
static 2
static 3
static 4
static 5
static 6
static 7
8
9
10
11
12
13
14
PAN
PAN FINE
TITL
TITL FINE
PT SPEED
RED
RED FINE
GREEN
GREEN FINE
BLUE
BLUE FINE
WHTIE
WHTIE FINE
DIMMER
DIMMER FINE
15
1
2
3
4
5
6
7
A SINGLE POINT
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
DMX RESET
DMX
DISPLAY
DISPLAY ON
SHORT
LONG
YES/NO
YES/NO
MENU
SETTING
WDMX
SETTINGS LOCK
OFF
ON
SERVECE LOCK
OFF
ON
Recovery *****
WDMXHIDE
YES
NO
WDMX POWER
OFF
ON
NETWORK
Net SWITCH
OFF
ON
IP MODE
DEFAUL IP
CUSTOM IP
CUSTOM IP EDIT
XX.XX.XX.XX
ADDR XXX
UNIVERS
WDMX RESET
YES
NO
PERFORM
DISPLAY LOCK
OFF
ON
UPLOAD
LOAD PARA
LOAD EDIT
YES
NO
YES
NO
●【FANS】menu, select【Slow/Norm/Fast/Auto】as required fan speed.
●【PAN INVERT】menu, select 【NORM/INVERT】for normal/inverted control of
the PAN function
●【TILT INVERT】menu, select 【NORM/INVERT】for normal/inverted control of
the TILT function
●【PT SPEED】menu, select 【Slow/Fast】as required PAN/TILT movement
speed.
●【BLACKD】menu, select 【OFF】for immediate activation of PAN/TILT
blackout when selected using the control channel or 【ON】 for 3 second delay
before activation.
●【DIMMER】 menu for selection of 【DIM1/DIM2/DIM3/DIM4/OFF】 special
dimming curves
【 】 [ ] ● COLOR is for activate/unactivate the color calibration functions. When RGBtoW
is selected, on RGB = 255,255,255, the color is displayed as calibratedin
Service -- RGBtoW. When COLOR is set OFF , on RGB = 255,255,255, the [ ] [ ]
RGBvalues are not adjusted and the output is most powerful.When [UC] is selected,
the RGB output are adjusted to a standard preset universal color which balances
fixtures from different generations.
●FULL POWER CCT is the color temperature choose bottom, press UP/DOWN to 【 】
choose, under full power, <3200K>、<4200K>、<5600K> 、<10000K> can be chosen,
when choose <COLOR>, <3200K>、<4200K>、<5600K> 、<10000K>are not work, but
choose <NORMAL>.
●PWM is PWM reflesh rate bottom, press UP/DOWN to choose <1200Hz>、<2000Hz>、【 】
<2400Hz>、<6000Hz>、<25000Hz>
Note: with reflesh rate increased, gray rate of dimmer will be reduced
SINGLE POINT
CONTROL FUNCTION

6
17
static 16
static 17
static 18
static 19
static 20
static 21
static 22
static 23
static 24
static 25
static 26
static 27
static 28
static 29
black
static ALL
RING1 slow-->fast
RING2A slow-->fast
RING2B slow-->fast
RING2C slow-->fast
RING3A slow-->fast
RING3B slow-->fast
RING3C slow-->fast
RING3D slow-->fast
RING3E slow-->fast
RING4 slow-->fast
RING5 slow-->fast
GINR6 slow-->fast
1
2
3
4
5
6
7
static 8
static 9
static 10
static 11
static 12
static 13
static 14
static 15
2,3
4,5
6,7
2,5
3,6
4,7
2,3,4
5,6,7
1,2,3
1,4,5
1,6,7
1,2,5
1,3,6
1,4,7
3,5,7
5,6,7
1,3,5,7
1,5,6,7
1,2,4,5,7
1,2,3,5,6
1,3,4,6,7
2,3,4,5,6,7
DARK
BRIGHT
(2)-(3)-(4)-(5)-(6)-(7 )
(2,3)-(4,5)-(6,7 )
(2,5)-(3,6)-(4,7 )
(1,2)-(1,3)-(1,4)-(1,5)-(1,6)-(1,7 )
(2,3,4)-(5,6,7 )
(1,2,3)-(1,4,5)-(1,6,7 )
(1,2,5)-(1,3,6)-(1,4,7 )
(2,5,7)-(1,4,6 )
(2,3,4)-(3,4,5)-(4,5,6)-(5,6,7)-(6,7,2)-(7,2,3 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7 )
(1,2,3,5,6)-(1,3,4,6,7)-(1,4,5,7,2 )
(1)-(2,3,4,5,6,7 )
17
CHANNEL FUNCTIONVALUE
To identify up, middle and down by head
which after the fixture electrify & reset
PLUTO 2000XE
SS646
FANS
PERFORM
SLOW
NORMAL
FAST
AUTO
BLACKOUT
OFF
ON
DIMMER
DIM4
DIM3
DIM2
DIM1
OFF
PAN/TILT
PAN INVERT
NORMAL
INVERT
TITL INVERT
NORMAL
INVERT
PT SPEED
FAST
SLOW
COLOR
UC
RGB to W
OFF
PT RANGE
P.START
P.END
T.START
T.END
USE
0-255
0-255
0-255
0-255
NO
YES
FULL POWER CCT
3200K
4200K
5600K
10000K
NORMAL
MENU
HSIC
PERSON
PERSON1
PERSON2
CMY
PIXEL
MENU
● Enter the【PERSON】mode to select DMX mode:【 】HSIC ,
【 】 【 】 【 】 【PIXEL】PERSON1 ,PERSON2 ,CMY , ,
3.4 PERSONALITY
ADDRESS
001-512
MENU
3.3 DMX512 SETTINGS
● Enter the【DMX】mode to set the DMX ADDRESS.
3.5 PERFORM
DMX ERROR
SAVE
BLACK
PWM
1200Hz
2000Hz
2400Hz
6000Hz
25000Hz
SINGLE POINT CONTROL FUNCTION

518
20
CONTROL
NO FUNCTION
PAN/TILT BLACK ACTIVATED
PAN/TILT BLACK DEACTIVATED
FAN SLOW
FAN NORMAL
FAN FAST
FAN AUTO
AUTO1
AUTO2
CUSTOM
TEST
RESET
NO FUNCTION
DIM0
DIM1
DIM2
DIM3
DIM4
NO FUNCTION
18
19
179
STROBE
NO FUNCTION
STROBE FROM (SLOD TO FAST ,0-25Hz)
NO FUNCTION
LIGHTNING STROBE
NO FUNCTION
RANDOM SROBE
ZOOM
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
STAND ALONE
RUN
DMX512
ARTNET
ARTNET2DMX
AUTO1
AUTO2
CUSTOM
EDIT
PAN
TITL
RED
GREEN
BLUE
WHTIE
DIMMER
STROBE
TIME
USE
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-25
0-255
YES
INFO
SYSTEM ERROR
TEMPERATURE
VERSION
MANUAL
ALL RESET
YES
PT RESET
SERVICE
CALIB.C 2700K
4200K
5600K
6500K
8000K
3200K
ZOOM
0-255
RGBtoW RED
GREEN
BLUE
0-255
0-255
0-255
STEP(01-50)
V01
NO
YES
NO
WDMX
SERVECE LOCK
OFF
ON
RECOVERY *****
WDMXHIDE
YES
NO
WDMX POWER
OFF
ON
NETWORK
Net SWITCH
OFF
ON
IP MODE
DEFAUL IP
CUSTOM IP
CUSTOM IP EDIT
XX.XX.XX.XX
ADDR XXX
UNIVERS
WDMX RESET
YES
NO
TEST
SLAVE
NETWORK PARA
RDM UID
LABEL
0X388Axxxxxxxx
PLUTO 2000XE
NO
RED
GREEN
BLUE
0-255
0-255
0-255
WHTIE
0-255
CALR ****

4
19
1
2
3
4
5
6
PAN
PAN FINE
TITL
TITL FINE
PT SPEED
CYAN
MAGENT
YELLOW
DIMMER
7
8
9
10
11
A SINGLE POINT
NO FUNCTION
static 1
static 2
static 3
static 4
static 5
static 6
static 7
static 8
static 9
static 10
static 11
static 12
static 13
static 14
static 15
1
2
3
4
5
6
7
2,3
4,5
6,7
2,5
3,6
4,7
2,3,4
5,6,7
MARCOS
NO FUNCTION
RED 100% / GREEN UP / BLUE 0%
RED DOWN / GREEN 100% / BLUE 0%
RED 0% / GREEN 100% / BLUE UP
RED 0% / GREEN DOWN / BLUE 100%
RED UP / GREEN 0% / BLUE 100%
RED 100% /GREEN 0%/BLUE DOWN
RED 100%/GREEN UP/BLUE UP
RED DOWN/GREEN DOWN/BLUE 100%
ALL LED AT FULL OUTPUT
2700K
3200K
4200K
5600K
6500K
8000K
CHANNEL FUNCTIONVALUE
PLUTO 2000XE
SS646
MENU
ADDRESS
HSIC
PERSON
001-512
PERSON1
PERSON2
FANS
PERFORM
SLOW
NORMAL
FAST
AUTO
BLACKOUT
OFF
ON
DIMMER
DIM4
DIM3
DIM2
DIM1
OFF
CMY
PAN/TILT
PAN INVERT
NORMAL
INVERT
TITL INVERT
NORMAL
INVERT
PT SPEED
FAST
SLOW
COLOR
UC
RGB to W
OFF
PIXEL
PT RANGE
P.START
P.END
T.START
T.END
USE
0-255
0-255
0-255
0-255
NO
YES
DMX ERROR
SAVE
BLACK
DMX RESET
DMX
DISPLAY
DISPLAY ON
SHORT
LONG
DISPLAY LOCK
OFF
ON
YES/NO
YES/NO
FULL POWER CCT
3200K
4200K
5600K
10000K
NORMAL
3.2 MENU MAP
PWM
1200Hz
2000Hz
2400Hz
6000Hz
25000Hz
SETTING
SETTINGS LOCK
OFF
ON
UPLOAD
LOAD PARA
LOAD EDIT
YES
NO
YES
NO
SINGLE POINT
CONTROL FUNCTION
This manual suits for next models
1
Table of contents
Other ShowPro Dj Equipment manuals

ShowPro
ShowPro Pro Haze 3500 User manual

ShowPro
ShowPro Fusion IP Profile FC User manual

ShowPro
ShowPro LED House Light User manual

ShowPro
ShowPro Atomizer Pro Hazer User manual

ShowPro
ShowPro LED PAR Hex-18 IP65 User manual

ShowPro
ShowPro Hercules User manual

ShowPro
ShowPro K SMART PROFILE User manual

ShowPro
ShowPro Atomizer Pro Hazer User manual

ShowPro
ShowPro NEPTUNE 200 BEAM User manual

ShowPro
ShowPro ALLIGATOR User manual