Shure PGX Wireless System User manual

Shure PGX Wireless
PGX Wireless System
©2011 Shure Incorporated
27B15772 (Rev. 1)
Printed in U.S.A.
Nirkabel PGX Shure
Shure PGXワイヤレス
Shure PGX 무선
Shure PGX 无线系统

Copyright © 2010, Shure Incorporated Printed in U.S.A.
XXXXXXX


4
Guitar systems include:
• PGX1 bodypack transmitter
• 1/4” to mini 4-pin guitar cable
PGX4 Receiver Features
Back Panel
System Components
Front Panel
⑦ ACadapterjack
⑧ Adaptercordtie-off
⑨ XLRmicrophoneoutputjack
⑩ 6.35mm(1/4”)instrumentlevel
outputjack(unbalanced).
All systems include:
• PGX4 receiver
• 2 AA batteries
• Power supply
• User guide
Vocalist systems include:
• MicrophoneHead(choiceofPG58,
SM58®,SM86,Beta58A®)
• PGX2 handheld transmitter
• Microphone clip
Lavalier, Headworn, and
Instrument systems
include:
• PGX1 bodypack transmitter
• Microphone(choiceofWL93,
WL185,PG30orBeta98H/C™)
① audioLED
Indicatesstrengthofincomingaudiosignal:green
fornormal,amberforstrongandredforclipping.
② LEDScreen
Displaysgroupandchannelsetting.See“Single
SystemSetup”fordetails.
③ channel button
Changesgroupandchannelsetting.See“Single
SystemSetup”fordetails.
④ readyLED
Indicates system ready and receiving an RF signal
fromthetransmitter.
⑤ Infrared(IR)port
SendsIRsignaltotransmitterforsync.
⑥ sync button
Press to synchronize transmitter with receiver group
and channel settings.
⑥
INSTRUMENT OUTMIC OUT
⑦⑧⑨⑩

5
3
1
2
3
PGX1
4
5
PGXD
1
2
Transmitter Controls and Connectors
Changing Batteries
Transmitter Indicator LED
Green ready
Flashing green ControlsLocked
Amber Mute On
Flashing red IR transmission in process
Glowing red Battery power low
Pulsing Red on startup Batteries dead (transmitter cannot be turned on until batteries
are changed)
PulsingRedafter
synchronization
Transmitter and receive incompatible; contact your Shure
reseller
Wearing the Bodypack Transmitter
① IndicatorLED
Displaysbatterylevel,mute,andIRtransmission
status (see table).
② Power/MuteSwitch
Press to mute or unmute. Press and hold to
poweronoroff.
③ Infrared(IR)port
Receivesinfraredbeamtosynchronize
frequencies.Whenusingmultiplesystems,only
one transmitter IR port should be exposed at a
time.
④ 4-PinMicrophoneInputJack
⑤ AudioGainAdjustment
Clip the transmitter to a belt or slide a guitar strap through
the transmitter clip as shown.
For best results, slide the transmitter until the belt is pressed
againstthebaseoftheclip.
• ExpectedlifeforanAlkalinebatteryisapproximately8hours.
• Whenthetransmitterlightglowsred,thebatteriesshouldbechanged
immediately, as shown.

6
Adjusting Gain
PGX1
PGX2
PGXD
Single System Setup
Scan
Usethescanfeatureonthereceivertofinda
clear channel.
LEDscreendisplayscurrent
channel
press channelbuttontoscanfora
clear channel
systemscansforthechannelwiththe
leastinterference
Synchronize
Synchronize the transmitter to the receiver by aligning the
infrared(IR)portsandpressingthesync button. Make sure
the IR ports are closely aligned.
Afterasuccessfulsync,thetransmitterLEDmomentarily
flashesredandthereceiverreadylightilluminates.
Three gain settings are available on the PGX1. Choose the appropri-
atesettingforyourinstrument.
• mic:Microphone(higheramplification)
• 0:Guitarwithpassivepickups(mediumamplification)
• –10:Guitarwithactivepickups(loweramplification)
IfthereceiverLEDindicatestheinputvolumeisoverloadingthere-
ceiver, try switching the gain to a lower setting.
Accessthegainadjustmentswitchbyunscrewingtheheadofthe
microphone.
TwogainsettingsareavailableonthePGX2.Usethetipofapenor
a small screwdriver to move the switch.
• 0dB:Forquiettonormalvocalperformance.
• –10dB:Useonlyifaudioisdistortedduetohighvoallevels.
channel
channel
sync
ready
audio channel select
< 15 cm (8 in.)
or
sync
BIAS
AUDIO
0dB -10dB
AUDIO
0dB -10dB
0
-10dB
mic
0
-10dB
mic

7
Multiple System Setup
Usethefollowingstepstoensurethebestperformancewheninstallingmul-
tiple wireless systems at the same location.
1. Turnallreceiversonandalltransmittersoff.
Note:Turnonanyotherdigitalequipmentthatcouldcauseinterference
duringtheperformancesoitwillbedetectedduringthefrequencyscansin
thefollowingsteps.
2. Makesurethegroupnumberisthesameforallreceivers(seeManual
Group Selection).
3. Performascanusingthefirstreceiver.
4. Turnonthefirsttransmitterandsyncittothereceiver.
5. Repeatforeachsystem.
• Important:Aftersyncingeachtransmitter,leaveitonsothatscansfrom
the other receivers will not select that channel.
• Be sure only one transmitter IR port is exposed when synchronizing
each system.
Transmitter
Manual Channel and Group Selection (receiver only)
Locking and Unlocking Controls
Receiver
Usingthereceivertoscanforachannelisthe
bestwaytofindthebestfrequencyforyoursys-
tem.However,formultiplesystemsetup,you
may need to manually set the group number.
1. Press and hold the channel button.
2. Hold the button until the channel or group
displaybeginsflashing.
3. Release and press the button again to ad-
vance the setting.
At the desired channel or group number,
waitfortheflashingtostop.Thisactivates
the new setting.
4. Transferthenewfrequencysettingto
the transmitter using the automatic sync
function.
Tolockthecontrols:Withthetransmitteroff,holdthepower but-
tondownuntilthegreenLEDflashes(~5seconds)
Tounlockthecontrols:Withthetransmitteron,holdthepower
buttondownuntilthegreenLEDflashes(~5seconds)
Tolockthechannel:Holdthechannel button until
thenumbersflash(~10seconds)
Tounlockthechannel:Holdthechannel button
untilthenumbersflash(~5seconds)
Lockingthesystemcontrolspreventsaccidentalmutingorchannel
adjustmentduringperformances.
channel
group display
channel
channel
select
3 s
channel
channel display
channel
channel channel
select
6 s
channel

8
Troubleshooting
Issue Indicator
Status
Solution
No sound
orfaint
sound
Transmitter power
light on, receiver
LEDson
• Performautomatictransmittersetup
• Verifyallsoundsystemconnections
ReceiverLEDoff • Make sure AC adapter is securly plugged into electrical outlet
• Make sure AC electrical outlet works and is supplying proper voltage
Transmitter power
light glowing or
flashingred
• Replace transmitter batteries
• Ifindicatorcontinuesflashingredafterbatteriesarereplaced,thetransmitter
andreceivermaybelongtoincompatiblefrequencybands.Contactyour
Shureresellerforassistance.
Transmitter power
lightoff
• Turn on transmitter
• Make sure the +/- indicators on batteries match the transmitter terminals
• Insertfreshbatteries
Distortion
or
unwanted
noise
bursts
N/A • RemovenearbysourcesofRFinterferance(CDplayers,computers,digital
effects,in-earmonitorsystems,etc.)
• ‣Changereceiverandtransmittertoadifferentfrequency
• ‣Reducetransmittergain
• ‣Replacetransmitterbatteries
• ‣Ifusingmultiplesystems,changethefrequencyofoneoftheactive
systems
Distortion
increases
gradually
Transmitter power
light glowing or
flashingred
Replace transmitter batteries
Sound level
different
fromcabled
guitar or
microphone
or when
using
different
guitars
Adjusttransmittergainasnecessary
Cannot turn
transmitter
on
Transmitter light
flashingred
Replace transmitter batteries

9
PGX
Working Range
LineofSight
100m(300ft)
Note:ActualrangedependsonRFsignalabsorption,
reflectionandinterference.
Audio Frequency Response 45–15000 Hz
Note:Dependentonmicrophonetype
Total Harmonic Distortion
Ref.±33kHzdeviation,1kHztone 0.5%, typical
Dynamic Range >100 dB, A-weighted
Operating Temperature Range -18°C(0°F)–+50°C(122°F)
Note:Batterycharacteristicsmaylimitthisrange.
Transmitter Audio Polarity Positive pressure on microphone diaphragm (or positive
voltageappliedtotipofWA302phoneplug)produces
positivevoltageonpin2(withrespecttopin3oflow-
impedanceoutput)andthetipofthehighimpedance
1/4-inch output.
PGX1
Audio Input Level gain position
mic: −10dBVmaximum
0dB: +10dBV maximum
–10dB: +20dBV maximum
Gain Adjustment Range 30dB
Input Impedance 1MΩ
RF Output Power 10–30mW
varies by region
Pin Assignments
TA4M
1:ground(cableshield)
2:+5VBias
3:audio
4:Tiedthroughactiveloadtoground(Oninstrumentadaptercable,pin4floats)
Dimensions 108mmx64mmx19mm(HxWxD)
Weight 81g(3oz.),withoutbatteries
Housing Molded polycarbonate case
Power Requirements 2“AA”sizealkalineorrechargeablebatteries
Battery Life upto8hours(alkaline)
PGX2
Audio Input Level at –10 dB gain setting: +2dBV maximum
at 0 dB gain setting: –8dBVmaximum
Gain Adjustment Range 10 dB
RF Output Power 10–30mW
varies by region
Dimensions 254 mm X 51 mm dia. (10 X 2 in.)
Weight 81g(10.2oz.)(withoutbatteries)
Housing Molded PC/ABS handle and battery cup
Power Requirements 2“AA”sizealkalineorrechargeablebatteries
Battery Life upto8hours(alkaline)
Specifications

10
PGX4
Dimensions 40mmX181mmX104mm(HxWxD)
Weight 327g(11.5oz.)
Housing ABS
Sensitivity -105dBmfor12dBSINAD,typical
Image Rejection >70 dB, typical
Power Requirements 12–18VDC@150mA,suppliedbyexternalpowersupply(tippositive)
Configuration Impedance balanced
Audio Output Level
Ref.±33kHzdeviation,1kHztone
XLR connector: –19dBV(into600Ωload)
6.35 mm (1/4”) connector: –5dBV(into3kΩload)
Impedance XLR connector: 200Ω
6.35 mm (1/4”) connector: 1kΩ
Pin Assignments XLR connector: 1=ground,2=hot,3=cold
6.35 mm (1/4”) connector: Tip=audio, Ring=no audio,
Sleeve=ground
Frequency Range and Transmitter Output Level
Band Range Output
Power
H6 524 to 542 MHz 30mW
J6 572.250to590.875MHz 30mW
K5E 606to630MHz 10mW
L5 644to662MHz 30mW
P6 702.200to719MHz 30mW
R1 800to820MHz 20mW
T1 846to865MHz 10mW
Q8 740 to 752 MHz 10mW
JB 806to810MHz 10mW
R14 794to806MHz 20mW
R19 794to806MHz 10mW
X5 925to932MHz 10mW
G4 470.125to493.825MHz 30mW
G8 494.200to509.825MHz 30mW
Q24 736to754MHz 30mW
NOTE:
ThisRadioequipmentisintendedforuseinmusical
professionalentertainmentandsimilarapplications.
ThisRadioapparatusmaybecapableofoperatingonsome
frequenciesnotauthorizedinyourregion.Pleasecontact
yournationalauthoritytoobtaininformationonauthorized
frequenciesandRFpowerlevelsforwirelessmicrophone
products.

11
PGX1, PGX2, PGX4
CERTIFICATION
ThisClassBdigitalapparatuscomplieswithCanadianICES-003.
CetappareilnumériquedelaclasseBestconformeàlanormeNMB-003duCanada.
MeetsrequirementsofEMCstandardsEN300422Parts1and2andEN301489Parts1and9.
MeetsessentialrequirementsofEuropeanR&TTEDirective99/5/EC,eligibletobeartheCEmark.
PGX1, PGX2
CertifiedunderFCCPart74.(FCCID:DD4PGX1A,DD4PGX2A,DD4SLX1,DD4SLX2).CertifiedbyICinCanadaunder
RSS-123andRSS-102.(IC:616A-SLX1,616A-SLX2).
PGX4
ApprovedundertheDeclarationofConformity(DoC)provisionofFCCPart15.CertifiedinCanadabyICtoRSS-123.
(IC:616A-PGX4A,616A-PGX4B,616A-PGX4C,616A-PGX4D).
Operationofthisdeviceissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseinterference,and(2)this
devicemustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthedevice.
DoC
TheCEDeclarationofConformitycanbeobtainedfromShureIncorporatedoranyofitsEuropeanrepresentatives.Forcontact
informationpleasevisitwww.shure.com
TheCEDeclarationofConformitycanbeobtainedfrom:www.shure.com/europe/compliance
AuthorizedEuropeanrepresentative:
ShureEuropeGmbH
HeadquartersEurope,MiddleEast&Africa
Department:EMEAApproval
WannenackerStr.28
D-74078Heilbronn,Germany
Phone:+49713172140
Fax:+497131721414
Email:[email protected]
LICENSING INFORMATION
Licensing:Aministeriallicensetooperatethisequipmentmayberequiredincertainareas.Consultyournationalauthorityfor
possiblerequirements.ChangesormodificationsnotexpresslyapprovedbyShureIncorporatedcouldvoidyourauthoritytoop-
eratetheequipment.LicensingofShurewirelessmicrophoneequipmentistheuser’sresponsibility,andlicensabilitydependson
theuser’sclassificationandapplication,andontheselectedfrequency.Shurestronglyurgestheusertocontacttheappropriate
telecommunicationsauthorityconcerningproperlicensing,andbeforechoosingandorderingfrequencies.
Information to the user
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCC
Rules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.
Thisequipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe
instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnot
occurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbe
determinedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe
followingmeasures:
• Reorient or relocate the receiving antenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmenttoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.
• Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
Note:EMCconformancetestingisbasedontheuseofsuppliedandrecommendedcabletypes.Theuseofothercabletypes
maydegradeEMCperformance.
Changesormodificationsnotexpresslyapprovedbythemanufacturercouldvoidtheuser’sauthoritytooperatetheequipment.

12
ギターシステムには以下の機器
が同梱されています。
• PGX1ボディパック型送信機
• フォーンプラグ~ミニ4ピンギター
ケーブル
PGX4受信機の機能
背面パネル
システムの構成
フロントパネル
⑦ ACアダプタージャック
⑧ ACアダプターケーブル固定用ループ
⑨ XLRマイクロホン出力ジャック
⑩ 6.35mm楽器レベル出力ジャック(アンバ
ランス)。
全てのシステムには以下の
ものが同梱されています:
• PGX4受信機
• 単三電池2個
• ACアダプター
• 取扱説明書
ボーカリストシステムには以下の機器が同梱さ
れています。
• マイクロホンヘッド(PG58、SM58®、SM86、Beta58A®の
うちどれか1つ)
• PGX2ハンドヘルド型送信機
• マイクホルダー
ラベリア、ヘッドウォーンおよび
楽器システム同梱品:
• PGX1ボディパック型送信機
• マイクロホン(WL93、WL185、PG30
、Beta98H/C™のうちどれか1つ)
① audio(オーディオ)LED
入力されたオーディオ信号の強度を示します。通常は緑色、
高レベルでは黄色、クリッピングすると赤色になります。
② LEDスクリーン
グループ及びチャンネル設定を表示します。詳細は「単独シ
ステムの設定」を参照してください。
③ channel(チャンネル)ボタン
グループ及びチャンネル設定を変更します。詳細は「単独シ
ステムの設定」を参照してください。
④ ready(レディ)LED
システムが使用できる状態で、送信機からの電波を受信して
いることを示します。
⑤ 赤外線(IR)ポート
同期のための赤外線信号を送信機に送ります。
⑥ sync(同期)ボタン
このボタンを押すと、送信機のグループとチャンネルの設定
を受信機と同期できます。
⑥
INSTRUMENT OUTMIC OUT
⑦⑧⑨⑩

13
PGXD
1
23
1
2
3
PGX1
4
5
送信機の操作部とコネクター
電池の交換
送信機インジケーターLED
緑色 レディ
緑色の点滅 操作部がロックされています
黄色 ミュート中
赤色の点滅 赤外線通信中
赤色の点灯 電池残量低下
起動時に赤色がゆっく
り点滅
電池切れ(電池を入れ替えないと送信機は作動しません)
同期操作後に赤色がゆっ
くり点滅
送信機と受信機に互換性がありません。代理店にお問い合わせく
ださい。
ボディパック型送信機の取付方法
① インジケーターLED
バッテリー残量、ミュート、赤外線送信ステータスを表示し
ます(表を参照)。
② 電源/ミュートスイッチ
押してミュートまたはミュート解除を行います。スイッチを
押し続けると電源がオン・オフされます。
③ 赤外線(IR)ポート
周波数設定を同期するための赤外線信号を受信しま
す。複数システムを使用している場合には、送信機の赤外
線ポートは対象の1つだけを見せるようにしてください。
④ 4ピンマイクロホン入力ジャック
⑤ オーディオゲイン調整
図のように、送信機をベルトに留めるか、送信機のクリップにギタ
ーストラップを通します。
クリップの上端まで来るようしっかりとベルトに装着してください。
• アルカリ乾電池での平均的な動作時間は約8時間です。
• 送信機のLEDが赤色に点灯した場合には、上記の手順で速やかに電池を
交換してください。

14
ゲインの調整
PGX1
PGX2
PGXD
単独システムの設定
スキャン
受信機のスキャン機能を使って、空きチャンネルを探し
ます。
LEDスクリーンは現在のチャンネルを
表示しています
channelボタンを押して空きチャンネルを
スキャンします
システムは干渉が最も少ないチャンネ
ルを探してスキャンします
同期
赤外線(IR)ポートを合わせ、syncボタンを押すと、送信機と受信機
が同期されます。IRポートをできるだけ近づけてください。
同期が成功したら、送信機のLEDが一瞬赤に点滅し、受信機
のreadyライトが点灯します。
PGX1には3段階のゲイン設定があります。ご使用の楽器に合ったゲインを
選択してください。
• mic:マイクロホン(増幅度:大)
• 0:パッシブピックアップのギター(増幅度:中)
• –10:アクティブピックアップのギター(増幅度:低)
受信機のaudio(オーディオ)LEDがクリッピングを表示している場合には、
ゲインを低い設定に切り換えてみてください。
マイクロホンのヘッドを回して外すと、ゲイン調整スイッチがあります。
PGX2には2段階のゲイン設定があります。ペン先または小型のマイナスド
ライバーを使用してスイッチを動かします。
• 0dB:静寂~普通のボーカルパフォーマンス用。
• –10dB:高レベルのボーカルのために音が歪む場合のみ使用して
ください。
channel
channel
sync
ready
audio channel select
< 15 cm (8 in.)
or
sync
BIAS
AUDIO
0dB -10dB
AUDIO
0dB -10dB
0
-10dB
mic
0
-10dB
mic

15
複数システムの設定
複数のワイヤレスシステムを同じ場所で使用する際は、以下のステップにより最適な設定にすることができま
す。
1. 受信機はすべてオンにし、送信機はすべてオフにします。
注:演奏中に干渉を生じる恐れのある他のデジタル機器をオンにし、次のステップで周波数スキャンを行う
際に検出されるようにします。
2. すべての受信機でグループ番号が同じであることを確認してください(手動によるグループの選択を参照
してください)。
3. 最初の受信機を使用してスキャンを実施します。
4. 最初の送信機をオンにして受信機と同期します。
5. 各システムでこの手順を繰り返してください。
• 重要: 同期が完了した送信機は電源をオンのままにし、他の受信機でのスキャンの際にそのチャンネ
ルを選択しないようにします。
• 各システムを同期する際は、送信機の赤外線ポートは対象の1つだけを見せるようにしてください。
送信機
手動によるチャンネル及びグループ設定(受信機のみ)
操作部のロックおよびロック解除
受信機
受信機を使ってチャンネルをスキャンする方法が、
お持ちのシステムの最適な周波数を検出するのに
最も適した方法です。ただし、複数のシステムのセ
ットアップの場合、手動でグループ番号を設定しな
ければならない場合があります。
1. channelボタンを押し続けます。
2. チャンネルまたはグループ表示が点滅するまで
ボタンを押したままにします。
3. いったんボタンを離した後、ボタンを押すと番
号が進みます。
希望のチャンネルまたはグループ番号にして、
点滅が止まるのを待ちます。これで新しい設定
に変更されました。
4. 自動同期機能を使って、新しい周波数設定を
送信機に転送します。
操作部のロック方法: 送信機がオフの状態から、緑色のLEDが点滅す
るまで電源ボタンを押し続けます(約5秒間)
操作部のロック解除方法: 送信機がオンの状態から、緑色のLEDが点
滅するまで電源ボタンを押し続けます(約5秒間)
チャンネルのロック方法: 番号が点滅するま
でchannelボタンを押し続けます(約10秒間)
チャンネルのロック解除方法: 番号が点滅するま
でchannelボタンを押し続けます(約5秒間)
操作部をロックしておけば、演奏中に誤ってミュートやチャンネル切替が行わ
れてしまうことを避けられます。
channel
グループ表示
channel
channel
select
3 s
channel
channel
channel
channel
チャンネル表示
channel
select
6 s

16
トラブルシューティング
問題 インジケーター
の状態
解決策
音が聞こえな
い、またはかす
かに音がする
送信機および受信
機のLEDは点灯し
ている
• 送信機の自動設定を実行する
• サウンドシステムの接続をすべて確認する
受信機のLEDが消え
ている
• ACアダプターを確実にコンセントに差し込む
• ACコンセントが機能しており、適切な電圧を供給していることを確認する
送信機のインジケ
ーターLEDが赤く点
灯、または赤く点滅
している
• 送信機の電池を交換する
• 電池交換後もインジケーターLEDが赤色に点滅する場合は、送信機と受信機の周
波数帯域に互換性がない場合があります。ご不明な点があれば販売店までお問
い合わせください
送信機のインジケ
ーターLEDが消え
ている
• 送信機をオンにする
• 電池のプラスとマイナスの向きが送信機の表示に一致していることを確認する
• 新しい電池を入れる
歪みまたは不
要なノイズバ
ースト
関連する表示はあり
ません
• 近くにある電波干渉源(CDプレーヤー、コンピューター、デジタルエフェクター、イン
イヤーモニターシステムなど)を遠ざける
• ‣ 受信機および送信機を異なる周波数に変更する
• ‣送信機ゲインを下げる
• ‣ 送信機の電池を交換する
• ‣複数システムを使用している場合、動作中のシステムの1つの周波数を変更する
歪みが徐々に
増大する
送信機のインジケ
ーターLEDが赤く点
灯、または赤く点滅
している
送信機の電池を交換する
ケーブルで接続
したギターとマ
イクロホンで、あ
るいは別のギタ
ーでのレベルが
異なる
必要に応じて送信機ゲインを調整する
送信機がオンに
ならない
送信機のライトが赤
く点滅している
送信機の電池を交換する

17
PGX1
オーディオ入力レベル ゲインポジション
mic: −10dBV最大
0dB: +10dBV最大
–10dB: +20dBV最大
ゲイン調整範囲 30dB
入力インピーダンス 1MΩ
RF送信出力 10~30mW
地域により異なります
ピンの割当
TA4M
1: 接地(ケーブルシールド)
2: +5Vバイアス
3: オーディオ
4: アクティブロードから接地に連結(楽器用アダプターケーブルでは、ピン4は
浮きます)
寸法 108mmx64mmx19mm(高さ×幅×奥行き)
質量 81g(3オンス),電池除く
外装 成形ポリカーボネートケース
使用電源 単三形アルカリ乾電池2個または充電式電池
電池寿命 最大8時間(アルカリ乾電池)
PGX2
オーディオ入力レベル –10 dBゲイン設定時: +2dBV最大
0 dBゲイン設定時: –8dBV最大
ゲイン調整範囲 10dB
RF送信出力 10~30mW
地域により異なります
寸法 254mmX51mm直径(10X2インチ)
質量 81g(10.2oz.)(電池除く)
外装 成形PC/ABSハンドルおよび電池ケース
使用電源 単三形アルカリ乾電池2個または充電式電池
電池寿命 最大8時間(アルカリ乾電池)
PGX
到達距離
見通し線上の配置にて
100m(300ft)
注:実際の到達距離は、無線信号の吸収や反射、干渉により左右されます。
周波数特性 45~15000Hz
注:マイクロホンのタイプにより異なります
THD(全高周波歪率)
Ref. ±33kHz偏移、トーン1kHz 0.5%,標準
ダイナミックレンジ >100dB,Aウェイト
動作温度範囲 -18°C(0°F)~+50°C(122°F)
注:電池特性によりこの範囲は限定される場合があります。
送信機のオーディオ極性 マイクロホンのダイヤフラムへの正の圧力(またはWA302フォンプラグのチップ端子への
正電圧の適用)により、2番ピン(ロー・インピーダンス出力の3番ピンに対して)およびハ
イ・インピーダンス1/4インチ出力のチップ端子に正電圧が生成されます。
仕様

18
周波数帯域および送信機出力
帯 域 範 囲 送信機
出力
H6 524~542MHz 30mW
J6 572.250~590.875MHz 30mW
K5E 606~630MHz 10mW
L5 644~662MHz 30mW
P6 702.200~719MHz 30mW
R1 800~820MHz 20mW
T1 846~865MHz 10mW
Q8 740~752MHz 10mW
JB 806~810MHz 10mW
R14 794~806MHz 20mW
R19 794~806MHz 10mW
X5 925~932MHz 10mW
G4 470.125~493.825MHz 30mW
G8 494.200~509.825MHz 30mW
Q24 736~754MHz 30mW
注:
本無線機器は、業務用の音楽エンターテイメントおよび同様の用途に使用するため
のものです。
本無線機器はご使用の地域で認可されていない周波数で操作できる場合があります。
国内当局にお問い合わせになり、ワイヤレスマイクロホン製品の認可周波数とRF出力
レベルの情報をご確認ください。
PGX4
寸法 40mmX181mmX104mm(高さ×幅×奥行き)
質量 327g(11.5oz.)
外装 ABS
感度 -105dBm12dBSINAD用,標準
イメージ抑圧比 >70dB,標準
使用電源 12~18VDC@150mA,外部電源により供給(チッププラス)
構成 インピーダンスバランス
オーディオ出力レベル
Ref. ±33kHz偏移、トーン1kHz
XLRコネクター: –19dBV(600kΩ負荷へ)
6.35 mmフォーンジャック: –5dBV(3kΩ負荷へ)
インピーダンス XLRコネクター: 200Ω
6.35 mmフォーンジャック: 1kΩ
ピンの割当 XLRコネクター: 1=接地、2=ホット、3=コールド
6.35 mmフォーンジャック: チップ=オーディオ、リング=オーディ
オ無し、スリーブ=接地

19
Guitar 시스템에는 다음의
구성품들이 있습니다:
• PGX1보디팩송신기
• 1/4인치-미니4핀기타(Guitar)
케이블
PGX4 수신기의 특징
시스템 구성품
전면 패널
⑦ AC어댑터잭
⑧ 어댑터전선고정
⑨ XLR마이크출력잭
⑩ 6.35mm(1/4”)악기레벨출력잭
(언밸런스드).
모든 시스템에는 다음이
포함되어 있습니다:
• PGX4수신기
• 2AA건전지
• 전원공급장치
• 사용자안내서
Vocalist 시스템에는 다음의
구성품들이 있습니다:
• 마이크헤드(PG58,SM58®,SM86,
Beta58A®중에서선택)
• PGX2핸드헬드송신기
• 마이크클립
핀, 헤드원, 악기시스템은
다음과 같이 구성되어
있습니다:
• PGX1보디팩송신기
• 마이크(WL93,WL185,PG30,
Beta98H/C™중선택)
① 오디오LED
수신되는오디오신호의강도를표시합니다:초록색은
정상,황갈색은강함,빨간색은클리핑.
② LED화면
그룹및채널설정을표시합니다.자세한사항은“단일
시스템설정”을참조하십시오.
③ 채널버튼
그룹및채널설정을변경합니다.자세한사항은“단일
시스템설정”을참조하십시오.
④ 준비LED
시스템사용준비가되어송신기로부터RF신호를받음을
표시합니다.
⑤ 적외선(IR)포트
동기화를위해IR신호를송신기에보냅니다.
⑥ 동기(sync)버튼
송신기를수신기그룹및채널설정과동기화하기위해
누릅니다.
⑥
후면 패널
INSTRUMENT OUTMIC OUT
⑦⑧⑨⑩

20
PGXD
1
23
1
2
3
PGX1
4
5
송신기 컨트롤 및 커넥터
배터리 교환
송신기 표시기 LED
녹색 준비
초록색 등 점멸 컨트롤잠김
황갈색 뮤트동작중
빨간색 등 점멸 IR전송진행중
빨간색 점등 건전지전력낮음
시작할 때 빨간색 등 점멸 건전지소진(건전지교환시까지송신기전원은꺼지지않음)
동기화 후 빨간색 등 점멸 송신기와수신기가호환안됨,Shure대리점에문의요망
보디팩 송신기 착용
① 표시기LED
배터리수준,음소거및IR전송상태를표시합니다(
표참조).
② 전원/음소거스위치
음소거기능의작동또는해제를위해누릅니다.켜거나
끌때는누른채그대로있으면됩니다.
③ 적외선(IR)포트
주파수를일치시키기위한적외선광선을수신합니다.
여러 시스템을 사용할 때는, 한 번에 하나의 송신기 IR
포트만 노출되어야 합니다.
④ 4-핀마이크입력잭
⑤ 오디오게인조절
그림과같이송신기를벨트에걸거나송신기클립을기타스
트랩에끼웁니다.
최적의착용을위해벨트가클립의끝까지물릴때까지송신
기를밀어넣으십시오.
• 알카라인배터리하나의기대수명은대략8시간입니다.
• 송신기표시등이빨간색빛을내면,예시와같이,건전지를즉시
교체해야합니다.
Other manuals for PGX Wireless System
7
Table of contents
Languages:
Other Shure Microphone System manuals

Shure
Shure The SM58 Vocal Artist UHF User manual

Shure
Shure GLXD Plus FM User manual

Shure
Shure PGXD User manual

Shure
Shure ULX Wireless System User manual

Shure
Shure BLX Wireless System User manual

Shure
Shure ULXP4E K2E User manual

Shure
Shure PSM 900 User manual

Shure
Shure BLX Wireless System User manual

Shure
Shure EXHIBIT 212 User manual

Shure
Shure ULX Wireless System User manual