manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Circuit Breaker
  8. •
  9. Siemens NGB1 Series User manual

Siemens NGB1 Series User manual

This manual suits for next models

17

Other Siemens Circuit Breaker manuals

Siemens Sentron 8UD1721-0AB Series User manual

Siemens

Siemens Sentron 8UD1721-0AB Series User manual

Siemens HBLQR User manual

Siemens

Siemens HBLQR User manual

Siemens 3WN6 3WX3651-1J.00 User manual

Siemens

Siemens 3WN6 3WX3651-1J.00 User manual

Siemens 3VA9177-0TB50 User manual

Siemens

Siemens 3VA9177-0TB50 User manual

Siemens 3VT9100-8CB30 User manual

Siemens

Siemens 3VT9100-8CB30 User manual

Siemens SIRIUS User manual

Siemens

Siemens SIRIUS User manual

Siemens 3VL7710 6 Series User manual

Siemens

Siemens 3VL7710 6 Series User manual

Siemens 3AH47 series User manual

Siemens

Siemens 3AH47 series User manual

Siemens 3VF3 User manual

Siemens

Siemens 3VF3 User manual

Siemens SIRIUS 3RV2.4 User manual

Siemens

Siemens SIRIUS 3RV2.4 User manual

Siemens 3VA9978-0AA Series User manual

Siemens

Siemens 3VA9978-0AA Series User manual

Siemens GM-SG User manual

Siemens

Siemens GM-SG User manual

Siemens 3VA9988-0AB32 User manual

Siemens

Siemens 3VA9988-0AB32 User manual

Siemens 3VA9588-0LB10 User manual

Siemens

Siemens 3VA9588-0LB10 User manual

Siemens QR2 User manual

Siemens

Siemens QR2 User manual

Siemens 5SP3 Series User manual

Siemens

Siemens 5SP3 Series User manual

Siemens SENTRON 3WA1 User manual

Siemens

Siemens SENTRON 3WA1 User manual

Siemens Sentron 3WL5 Series User manual

Siemens

Siemens Sentron 3WL5 Series User manual

Siemens SIRIUS 3RV2.1 User manual

Siemens

Siemens SIRIUS 3RV2.1 User manual

Siemens 3AFS Series Programming manual

Siemens

Siemens 3AFS Series Programming manual

Siemens 3VA911-0KB01 Series User manual

Siemens

Siemens 3VA911-0KB01 Series User manual

Siemens 3VA9601-0WF30 User manual

Siemens

Siemens 3VA9601-0WF30 User manual

Siemens 8BK80 User manual

Siemens

Siemens 8BK80 User manual

Siemens SENTRON 3WL10 User manual

Siemens

Siemens SENTRON 3WL10 User manual

Popular Circuit Breaker manuals by other brands

Acrel ASCB1 Series Installation and operation manual

Acrel

Acrel ASCB1 Series Installation and operation manual

ABB SACE Emax 2 E2.2 manual

ABB

ABB SACE Emax 2 E2.2 manual

Eaton NOVA LBS 15 Installation and operation instructions

Eaton

Eaton NOVA LBS 15 Installation and operation instructions

ABB SACE Emax E1 quick start guide

ABB

ABB SACE Emax E1 quick start guide

WEG FHU ACW125 installation instructions

WEG

WEG FHU ACW125 installation instructions

TERASAKI NHP TemBreak PRO P160 Series installation instructions

TERASAKI

TERASAKI NHP TemBreak PRO P160 Series installation instructions

hager TS 303 User instruction

hager

hager TS 303 User instruction

ETI EFI-4B Instructions for mounting

ETI

ETI EFI-4B Instructions for mounting

Gladiator GCB150 Installation instruction

Gladiator

Gladiator GCB150 Installation instruction

nader NDM3EU-225 operating instructions

nader

nader NDM3EU-225 operating instructions

Eaton 50DHP-VR Instruction handbook

Eaton

Eaton 50DHP-VR Instruction handbook

ABB SACE Emax 2 E6.2 Instruction handbook

ABB

ABB SACE Emax 2 E6.2 Instruction handbook

Gewiss 90 RCD Installation

Gewiss

Gewiss 90 RCD Installation

OEZ LFN Instructions for use

OEZ

OEZ LFN Instructions for use

Eaton Power Defense PDG2 Instruction leaflet

Eaton

Eaton Power Defense PDG2 Instruction leaflet

Bticino L4412CM2 quick start guide

Bticino

Bticino L4412CM2 quick start guide

OEZ 3VA9-RS-4VBH1 Installation, service and maintenance instructions

OEZ

OEZ 3VA9-RS-4VBH1 Installation, service and maintenance instructions

Rockwell Automation Allen-Bradley 140G-G manual

Rockwell Automation

Rockwell Automation Allen-Bradley 140G-G manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NGB3B _ _ _ – 3 Poles [Polos] [Pôles]
HGB3B _ _ _ – 3 Poles [Polos] [Pôles]
LGB3B _ _ _ – 3 Poles [Polos] [Pôles]
NGB2B _ _ _ – 2 Poles [Polos] [Pôles]
HGB2B _ _ _ – 2 Poles [Polos] [Pôles]
LGB2B _ _ _ – 2 Poles [Polos] [Pôles]
NGB1B _ _ _ _ – 1 Pole [Polo] [Pôle]
HGB1B _ _ _ _ – 1 Pole [Polo] [Pôle]
LGB1B _ _ _ _ – 1 Pole [Polo] [Pôle]
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this device is
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this device is
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
This circuit breaker is intended for use only in Siemens Panelboard and Switchboard designs.
Use only with Siemens certified components.
[Este interruptor automático es para uso exclusivo en paneles diseñados por Siemens.]
[Utilizar únicamente con componentes certificados de Siemens.]
[Ce disjoncteur est réservé aux panneaux et tableaux de contrôle Siemens.]
[Utiliser uniquement avec des composantes certifiées de Siemens.]
s
1 / 3
Circuit Breaker – Type NGB(2) – HGB(2) – LGB(2)
Interruptor automático de potencia – Tipo NGB(2) – HGB(2) – LGB(2)
Disjoncteur – Type NGB(2) – HGB(2) – LGB(2)
Installation Instructions [ Instructivo de Instalación ] [ Instructions d'installation ]
NGB1C _ _ _ _
NGB2C _ _ _ _
NGB3C _ _ _ _
NGB1B _ _ _ NAV
NGB2B _ _ _ NAV
NGB3B _ _ _ NAV
NGB1_ _ _ _
NGB2_ _ _ _
NGB3_ _ _ _
806934 A06
HGB1_ _ _ _
HGB2_ _ _ _
HGB3_ _ _ _
LGB1_ _ _ _
LGB2_ _ _ _
LGB3_ _ _ _
Item [Article]:
OPTION: KITS [ OPCION: JUEGOS ] [ OPTION: ENSEMBLES ]
NGB1K _ _ _ _ – 1 Pole [Polo] [Pôle]
HGB1K _ _ _ _ – 1 Pole [Polo] [Pôle]
LGB1K _ _ _ _ – 1 Pole [Polo] [Pôle]
NGB3K _ _ _ – 3 Poles [Polos] [Pôles]
HGB3K _ _ _ – 3 Poles [Polos] [Pôles]
LGB3K _ _ _ – 3 Poles [Polos] [Pôles]
NGB2K _ _ _ – 2 Poles [Polos] [Pôles]
HGB2K_ _ _ – 2 Poles [Polos] [Pôles]
LGB2K _ _ _ – 2 Poles [Polos] [Pôles]
806934A06
NOTE - These instructions do not purport to cover all details or variations in equipment, or to provide for every possible
contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should
particular problems arise, which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the
local Siemens sales office. The contents of this instruction manual shall not become part of or modify any prior or existing
agreement, commitment or relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in
the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties
or modify the existing warranty.
Trademarks - Unless otherwise noted, all names identified by ® are registered trademarks of Siemens AG or Siemens Industry,
Inc. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could
violate the rights of the owner.
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this device is
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this device is
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
2 / 3 806934 A06
INSTALLATION [ INSTALACION ] [INSTALLATION]
Turn off and lock out all power supplying this equipment before installing this device.
[Desenergice totalmente el circuíto a este equipo antes de instalar o darle servicio a este aparato.]
[Mettre hors tension et verrouiller l'alimentation avant d'installer cet appareil.]
2
1
Where breaker is mounted on a metal surface, ensure insulating
material with a minimum dielectric strength of 600 V / mil [24 kV
/ mm] is applied as shown.
[En componentes certificados Siemens donde el interruptor se
instala en superficie de metal, instale material de insulación de
fuerza dieléctrica de por lo menos 600 V/mil [24 kV/mm] según
ilustración.]
[Lorsque le disjoncteur est installé sur une surface métallique,
utiliser un matériel isolant d´une rigidité diélectrique minimale
de 600 V/mil [24 kV/mm] tel qu´illustré.]
Insulation Requirements
[Requerimientos de aislamiento]
[Exigences en matière d’isolation]
Width: 1 in. [25.4 mm] X number of poles
Thickness: 0.010 in. [0.25 mm] minimum
[Ancho: 1 in. [25.4 mm] por polo]
[Grosor: 0.010 in. [0.25 mm] mínimo]
[Largeur: 1 po [25,4 mm] X nombre de pôles]
[Épaisseur : 0,010 po [0,25 mm] minimum]
2 in.
[50.8 mm]
Line Terminal Screw [Tornillo del Terminal de línea] [Vis de serrage de ligne]
Recommended No. 10-32 washer head or equivalent screw with washer
[Se recomienda tornillo de tamaño 10-32 con arandela.]
[Tête de rondelle nº 10-32 ou vis équivalente avec rondelle recommandée.]
5
18 – 23 lb. in.
[2 – 2.6 N-m]
6
4
“OFF” / “O” Position
[Apagado “OFF” / “O”]
[Position « ARRÊT » / « A »]
Barrier / Mounting Bracket
[Barrera / Placa de montura]
[Barrière / Support de fixation]
Line Bus
[Barra de alimentación]
[Bus ligne]
3
806934A06
3 / 3
Replace all covers before power supplying this device is turned on.
[Reemplace todas las barreras y cubiertas antes de energizar el interruptor.]
[Remettre tous les couvercles en place avant de remettre cet appareil sous tension.]
Subject to change without prior notice © Siemens Industry Inc. 2013
Siemens Industry, Inc. , Norcross, GA 30092 U.S.A.
Technical Support: Toll Free: 1-800-241-4453 Internet: www.usa.siemens.com/powerdistribution
806934 A06
- Required for use with: NGB _ B _ _ _
[Requerido para uso con]: NGB _ B _ _ _ U
[Requis pour utilisation avec]:
NUT KEEPER KIT – TNKG3 [JEU DE PLAQUE-ÉCROU –TNKG3]
[ JUEGO DE SUJETADORES DE BORNES – TNKG3 ]
TNKG3
WIRE CONNECTION
[ CONEXION DE CABLES ]
Cu / Al 60°C / 75° C
8 AWG – 40 lb. in. [4.5 N-m]
6 – 4 AWG – 45 lb. in. [5.1 N-m]
3 – 2/0 AWG – 55 lb. in. [6.2 N-m]
35 - 125
Amp
Cu / Al 60° C / 75° C
14 – 10 AWG – 35 lb. in. [4.0 N-m]
8 AWG – 40 lb. in. [4.5 N-m]
15 - 30
Amp
Replace all covers before power supplying this device is turned on.
[Reemplace todas las barreras y cubiertas antes de energizar el interruptor.]
[Remettre tous les couvercles en place avant de remettre cet appareil sous tension.]
5
1
2
clic
3
4
For use with [Para uso con] [À utiliser avec]: NGB _ B _ _ _V
NGB _ _ _ _ _ B
HGB _ _ _ _ _ B
LGB _ _ _ _ _ B
[ CONNEXION DE CÂBLE ]
Required Conductor Stranding [ Cantidad de hébras requeridasen alambre ] [ Câblage de
conducteur requis ]
Conductor Size
[ Tamaño de alambre ]
[ Taille de conducteur]
Number of strands [ Cantidad de hébras ] [Nombre de brins ]
Cu Al
AWG or kcmil [ mm2]Class [ Clase ]
[ Classe ] B
Class [ Clase ]
[ Classe ] C
Class [ Clase ]
[ Classe ] B
14 – 2 [ 2.5 – 35 ]
1 – 2/0 [ 50 ]
7
19
19
37
7 *
19
* Not to be used with Aluminum 14 AWG (2.1 mm2) conductors [ *No utilizar alambre de
aluminio calibre 14 AWG (2.1 mm2) ] [*Ne pas utiliser avec des conducteursen aluminium
de 14 AWG (2,1 mm2) ]