Siemens ProtoAir Start-up Guide
Page 4 of 66
TABLE OF CONTENTS
1Certification..........................................................................................................................................7
1.1 BTL Mark –BACnet®Testing Laboratory.......................................................................................7
2Introduction..........................................................................................................................................8
2.1 ProtoAir Gateway............................................................................................................................8
3ProtoAir Setup......................................................................................................................................9
3.1 Record Identification Data ..............................................................................................................9
3.2 Point Count Capacity and Registers per Device ............................................................................9
3.3 Configuring Modbus Device Communications .............................................................................10
3.3.1 Input COM Settings on Any Device Connected to the ProtoAir............................................10
3.3.2 Set Node-ID for Any Device Attached to the ProtoAir...........................................................10
3.4 Attaching the Antenna ..................................................................................................................10
4Interfacing ProtoAir to Devices........................................................................................................11
4.1 Device Connections to ProtoAir....................................................................................................11
4.2 Wiring Field Port to RS-485 Serial Network .................................................................................12
4.3 Bias Resistors...............................................................................................................................13
4.4 Termination Resistor.....................................................................................................................14
4.5 Power-Up ProtoAir........................................................................................................................15
5Connect the PC to the ProtoAir........................................................................................................16
5.1 Connecting to the ProtoAir via Ethernet.......................................................................................16
5.1.1 Enable Access Through the Local Browser ..........................................................................16
5.1.1.1 Changing the Subnet of the Connected PC...................................................................16
5.1.1.2 Changing the IP Address of the ProtoAir with FieldServer Toolbox..............................17
5.2 Connecting to the ProtoAir Over Wi-Fi Access Point...................................................................18
6Configure the ProtoAir......................................................................................................................19
6.1 Accessing the ProtoAir Web Configurator....................................................................................19
6.2 Select Field Protocol Configuration ..............................................................................................19
6.3 Setting ProtoAir Active Profiles.....................................................................................................20
6.3.1 Verify Device Communications .............................................................................................21
7BACnet: Setting Node_Offset to Assign Specific Device Instances............................................22
8How to Start the Installation Over: Clearing Profiles.....................................................................23
9Network Settings................................................................................................................................24
9.1 Navigate to the FS-GUI Network Settings....................................................................................24
9.2 Change the ProtoAir IP Address ..................................................................................................26
9.2.1 Update Wired Network Settings............................................................................................27
9.2.2 Update Wi-Fi Client Settings.................................................................................................28
9.2.3 Common Settings..................................................................................................................29
Appendix A Troubleshooting...................................................................................................................30
Appendix A.1 Lost or Incorrect IP Address .............................................................................................30
Appendix A.2 Viewing Diagnostic Information ........................................................................................31
Appendix A.3 Checking Wiring and Settings...........................................................................................32
Appendix A.4 LED Diagnostics for Communications Between ProtoAir and Devices............................33
Appendix A.5 Taking a FieldServer Diagnostic Capture.........................................................................34
Appendix A.5.1 Using the FieldServer Toolbox...................................................................................34
Appendix A.5.2 Using FS-GUI.............................................................................................................37
Appendix A.6 Wi-Fi Signal Strength........................................................................................................38
Appendix B Additional Information.........................................................................................................39
Appendix B.1 Updating Firmware............................................................................................................39
Appendix B.2 BACnet: Setting Network_Number for More Than One ProtoAir on the Subnet..............39
Appendix B.3 Securing ProtoAir with Passwords....................................................................................40
Appendix B.4 Wi-Fi Access Point Network Settings ...............................................................................41
Appendix B.5 Mounting ...........................................................................................................................42
Appendix B.6 Physical Dimension Drawing ............................................................................................43