INTRODUCTION The Model HMS-S and HMS-D Manual Stations, and
their Spanish and Portuguese versions, from Siemens
Industry, Inc., are field installed addressable devices
containing advanced control panel communication
technology. This technology, which provides two-
direction communication with the control panel,
produces an Intelligent Initiating Device. The HMS-S/-
SE/-SP are single action; the HMS-D/-DE/-DP are
double action.
PROGRAMMING Refer to Figure 1 to locate the opening on the MS cover that allows access to the
programming holes which are on the HMS printed circuit board.
To connect the HMS to the DPU Programmer/Tester,
insert the plug from the DPU cable provided with the
Programmer/Tester into the opening on the HMS as
shown in Figure 2. Because HMS devices are polarity
insensitive, the programming plug can be inserted into
the programming holes in either direction.
To prevent potential damage to the DPU DO NODO NO
DO NODO NO
DO NOTT
TT
T
connect an HMS to the DPU until at least one wire is
removed from terminals 1 or 2 of the HMS.
Follow the instructions in the DPU Manual
(P/N 315-033260) to program the HMS to the desired
address. Record the device address on the label
located on the HMS front panel.The HMS can now
be installed and wired to the system.
OPERATION The HMS-S and HMS-D manual stations, as well as their Spanish and Portuguese
versions, operate with the FireFinder-XLS or FS-250 Control Panels via the DLC or FS-
DLC Device Loop Card.
All HMS manual station housings have a pull down lever that locks in position after
releasing a spring loaded switch. (See Figure 4.) To indicate the manual station is
activated, the pull down lever remains down and locked until the station is physically
reset.
The HMS-D/-DE/-DP have an additional lever labeled PUSH IN/EMPUJE/EMPURRE
which must be operated first.
All models are reset by opening the hinged housing cover with an Allen key and then
closing and locking the cover.
Figure 1
MS Cover
Single/Dual Action Manual Pull Station
Installation Instructions
Models HMS-S / HMS-D
Models HMS-SE / HMS-DE (Spanish versions)
Models HMS-SP / HMS-DP (Portuguese versions)
OPENING TO
PROGRAMMING
POINTS
PLUG FROM
DPU
LOCATING TAB
PROGRAMMING
POINTS
Figure 2
Connecting the DPU Plug
INSTRUCTIONS
firealarmresources.com
WIRING
INSTALLATION Distribute the manual station boxes throughout the protected area so that they
are unobstructed, readily accessible, and located in the normal exit path. Place the
manual station according to the regulations of the authorities having jurisdiction.
Surface Mounting Mount the backplate to a Model SB-5R Backbox as shown in Figure 4.
Flush Mounting Mount the backplate to a user supplied single gang switchbox.
Do not overtighten the screws. Overtightening may distort the backplate.
Figure 3
Wiring Information
TO NEXT ADDRESSABLE DEVICE
LINE 1
LINE 1
LINE 2
LINE 2
EARTH GROUND
1
2
3
FROM INITIATING CONTROL PANEL
OR PREVIOUS ADDRESSABLE DEVICE
SUPERVISED STYLE 4/6
REFER TO DLC INSTALLATION
INSTRUCTIONS, P/N 315-033090
NOTES:
1. Recommended wire sizes:
18 AWG minimum, 14 AWG maximum
2. Wire larger than 14 AWG can damage the connector.
3. When using shielded cable without metal raceway or with
nonmetallic raceway, the shields should be terminated at the device
ground terminal. If the device box is already grounded by another
means, such as being mounted to a grounded structure, the wire
shields should be continuous and must be grounded solely at the point
of origin; for example, at the control panel.
4. When using shielded cable with metal raceway, the wiring shields
shall be continuous and grounded solely at the point of origin.The
device ground terminal shall be connected to the grounded device box.
5. When using metal raceway without shielded cable, connect the
device ground terminal to the grounded device box.
6. Metal raceway should be thoroughly grounded throughout the system.
7. In supervisory: All HMS manual stations draw 1mA.
8. All HMS manual stations are polarity insensitive devices. Line 1 and
Line 2 can be either line of the DLC or FS-DLC loop.
P/N 315-033200-7
3½ INCH DEEP
SWITCH BOX
(USER SUPPLIED)
MODEL
SB-5R
BACKPLATE
BACKPLATE
SURFACE
MOUNTING
ENCLOSURE
FLUSH
MOUNTING
ENCLOSURE
HOUSING HINGED
TO BACKPLATE
HOUSING
LOCKING
SCREW
5½ in.
3 in.
4 in.
2¾ in.
3½ in.
NAMEPLATE
Figure 4
Mounting The HMS
Siemens Industry, Inc.
Building Technologies Division
Florham Park, NJ
ELECTRICAL RATINGS
pooLCLD-SF/CLD
tnerruC.xaMAm1
Document ID A6V10239110
firealarmresources.com

This manual suits for next models

5

Other Siemens Industrial Equipment manuals

Siemens Simatic S7-1500/ET 200MP User guide

Siemens

Siemens Simatic S7-1500/ET 200MP User guide

Siemens Simatic S7-1500 User manual

Siemens

Siemens Simatic S7-1500 User manual

Siemens 3KC3424-2AA22-0AA3 User manual

Siemens

Siemens 3KC3424-2AA22-0AA3 User manual

Siemens RTLJLR User manual

Siemens

Siemens RTLJLR User manual

Siemens SENTRON VL1250 User manual

Siemens

Siemens SENTRON VL1250 User manual

Siemens SIMATIC ET 200M User manual

Siemens

Siemens SIMATIC ET 200M User manual

Siemens fMRI User manual

Siemens

Siemens fMRI User manual

Siemens SIMATIC S7-155R/H Technical Document

Siemens

Siemens SIMATIC S7-155R/H Technical Document

Siemens 3RK1903-1BA00 PM-D F1 User manual

Siemens

Siemens 3RK1903-1BA00 PM-D F1 User manual

Siemens SINAMICS S120 Installation and operation manual

Siemens

Siemens SINAMICS S120 Installation and operation manual

Siemens 3WN6 User manual

Siemens

Siemens 3WN6 User manual

Siemens Sivacon S8 User manual

Siemens

Siemens Sivacon S8 User manual

Siemens Sivacon S8 User manual

Siemens

Siemens Sivacon S8 User manual

Siemens SITRANS IQ User manual

Siemens

Siemens SITRANS IQ User manual

Siemens 8GK6430 - 4KK24 User manual

Siemens

Siemens 8GK6430 - 4KK24 User manual

Siemens LITHOSTAR Multiline Setup guide

Siemens

Siemens LITHOSTAR Multiline Setup guide

Siemens SIRIUS S00 User manual

Siemens

Siemens SIRIUS S00 User manual

Siemens PolyBlend PB600-4.5 User manual

Siemens

Siemens PolyBlend PB600-4.5 User manual

Siemens SIRIUS 3RA1923-1B User manual

Siemens

Siemens SIRIUS 3RA1923-1B User manual

Siemens ULTRAMAT 23 Series Technical Document

Siemens

Siemens ULTRAMAT 23 Series Technical Document

Siemens 3VA1225 - 1AA.2 User manual

Siemens

Siemens 3VA1225 - 1AA.2 User manual

Siemens SIRIUS 3RT133 User manual

Siemens

Siemens SIRIUS 3RT133 User manual

Siemens SIVACON 8PS BD2 Series User manual

Siemens

Siemens SIVACON 8PS BD2 Series User manual

Siemens SINUMERIK 840D sl Parts list manual

Siemens

Siemens SINUMERIK 840D sl Parts list manual

Popular Industrial Equipment manuals by other brands

ABB +Q957 user manual

ABB

ABB +Q957 user manual

G.B.C BASIC EDGE 50 instruction manual

G.B.C

G.B.C BASIC EDGE 50 instruction manual

Tronair Batpak 11-6602-1000 Operation & service manual

Tronair

Tronair Batpak 11-6602-1000 Operation & service manual

Pilz PNOZ mi2p Operation manual

Pilz

Pilz PNOZ mi2p Operation manual

Clemco Zero BNP 6012 manual

Clemco

Clemco Zero BNP 6012 manual

Erskine Attachments V-Plow Operator's manual

Erskine Attachments

Erskine Attachments V-Plow Operator's manual

ABB HT610965 Operation manual

ABB

ABB HT610965 Operation manual

Morra MH 540 user manual

Morra

Morra MH 540 user manual

Eaton S090ST manual

Eaton

Eaton S090ST manual

GRIGGIO G 240 P4 instructions

GRIGGIO

GRIGGIO G 240 P4 instructions

Nexen AIR CHAMP HT45 user manual

Nexen

Nexen AIR CHAMP HT45 user manual

WTE V5 installation manual

WTE

WTE V5 installation manual

ABB HT845232 Operation manual

ABB

ABB HT845232 Operation manual

SMC Networks CJP Series Operation manual

SMC Networks

SMC Networks CJP Series Operation manual

JohnDow Industries JDI-AFT58 Operator's manual

JohnDow Industries

JohnDow Industries JDI-AFT58 Operator's manual

IMB MB9016A instruction manual

IMB

IMB MB9016A instruction manual

Clarke CUMB1 Assembly & operating instructions

Clarke

Clarke CUMB1 Assembly & operating instructions

amiad Arkal Spin Klin 2 user guide

amiad

amiad Arkal Spin Klin 2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.