2 Safety
SMA Solar Technology AG
Installation Manual MDSEN-40-IA-en-11 7
2 Safety
2.1 Intended Use
The SMA Sensor Module is a module for SMA inverters. The SMA Sensor Module has different
interfaces for connecting various sensors. The SMA Sensor Module converts the signals of the
connected sensors and transmits them to the inverter.
The SMA Sensor Module has the following interfaces:
• Two temperature inputs for connecting the temperature sensors
• One analog input for voltage or current signals (e.g. of an irradiation sensor)
• One supply voltage for a signal source (e.g. of an irradiation sensor)
• One S0 interface (e.g. for connecting an anemometer or energy meter)
The product must only be installed in the following SMA inverters:
• STP 50-40 (SunnyTripowerCORE1)
• STP 50-41 (SunnyTripowerCORE1)
• STP 50-JP-40 (Sunny Tripower CORE1-JP)
The inverter still complies with the standard after the product has been installed.
The product must only be operated with temperature sensors with a Pt100 measuring shunt or a
Pt1000 measuring shunt.
The product must only be operated with irradiation sensors that can output a current signal in the
range from 0mA to 20mA or 4mA to 20mA or a voltage signal in the range from 0V to +10V.
The product must only be operated with anemometers with impulse output for S0 impulses in
accordance with DINEN62053-31 (IEC62053-31).
The product must only be operated with energy meters with S0 interface in accordance with
DINEN62053-31 (IEC62053-31).
A list with SMA Sensor Module compatible products is available at www.SMA-Solar.com.
All components must remain within their permitted operating ranges and their installation
requirements at all times.
The product must only be used in countries for which it is approved or released by SMA Solar
Technology AG and the grid operator.
Use SMA products only in accordance with the information provided in the enclosed
documentation and with the locally applicable laws, regulations, standards and directives. Any
other application may cause personal injury or property damage.
Any use of the product other than that described in the Intended Use section does not qualify as the
intended use.
The enclosed documentation is an integral part of this product. Keep the documentation in a
convenient, dry place for future reference and observe all instructions contained therein.
This document does not replace and is not intended to replace any local, state, provincial, federal
or national laws, regulations or codes applicable to the installation, electrical safety and use of the
product. SMA Solar Technology AG assumes no responsibility for the compliance or non-
compliance with such laws or codes in connection with the installation of the product.
The type label must remain permanently attached to the product.