1. Type of fluids
Please consult with SMC when using the product in
applications other than compressed air.
2. When there is a large amount of drainage.
Compressed air containing a large amount of drainage
can cause malfunction of pneumatic equipment. An air
dryer or water separator should be installed upstream
from filters.
3. Drain flushing
If condensation in the drain bowl is not emptied on a
regular basis, the bowl will overflow and allow the
condensation to enter the compressed air lines. It
causes malfunction of pneumatic equipment. If the
drain bowl is difficult to check and remove, installation
of a drain bowl with an auto drain option is
recommended.
For compressed air quality, refer to SMC’s Best
Pneumatics catalog.
4. Use clean air
Do not use compressed air that contains chemicals,
synthetic oils including organic solvents, salt or
corrosive gasses, etc., as it can cause damage or
malfunction.
1. When extremely dry air is used as the
fluid, degradation of the lubrication
properties in side the equipment may
occur, resulting in reduced reliability (or
reduced service life) of the equipment.
Please consult with SMC.
2. Install an air filter.
Install an air filter upstream near the valve. Select an
air filter with a filtration size of 5 μm or smaller.
3. Take measures to ensure air quality,
such as by installing an aftercooler, air
dryer, or water separator.
Compressed air that contains a large amount of
drainage can cause malfunction of pneumatic
equipment such as valves. Therefore, take
appropriate measures to ensure air quality, such as by
providing an aftercooler, air dryer, or water separator.
4. If excessive carbon powder is seen,
install a mist separator on the upstream
side of the valve.
If excessive carbon dust is generated by the
compressor, it may adhere to the inside of a valve and
cause it to malfunction.
For compressed air quality, refer to SMC’s Best
Pneumatics catalog.
1. Do not use in an atmosphere having corrosive gases,
chemicals, sea water, water, water steam, or where
there is direct contact with any of these .
2. Products with IP65 enclosures (based on IEC60529)
are protected against dust and water, however, these
products cannot be used in water.
3. Products compliant to IP65 satisfy the specifications
through mounting. Be sure to read the Precautions for
each product.
4. Do not use in an environment where flammable gas or
explosive gas exists. Usage may cause a fire or
explosion. The products do not have an explosion
proof construction.
5. Do not use in a place subject to heavy vibration and/or
shock.
6. The valve should not be exposed to prolonged sunlight.
Use a protective cover.
7. Remove any sources of excessive heat.
8. If it is used in an environment where there is possible
contact with oil, weld spatter, etc., exercise preventive
measures.
9. When the valve is mounted in a control panel or its
energized for a long time, make sure ambient
temperatures is within the specification of the valve.
1. Perform maintenance inspection
according to the procedures indicated in
the operation manual.
If handled improperly, malfunction and damage of
machinery or equipment may occur.
2. Removal of equipment, and
supply/exhaust of compressed air
When components are removed, first confirm that
measures are in place to prevent workpieces from
dropping, run-away equipment, etc. Then, cut off the
supply pressure and electric power, and exhaust all
compressed air from the system using the residual
pressure release function.
For 3-position closed center type, exhaust the
residual pressure between the valve and the cylinder.
When the equipment is operated after remounting or
replacement, first confirm that measures are in place
to prevent lurching of actuators, etc. Then, confirm
that the equipment is operating normally.
3. Low frequency operation
Valves should be operated at least once every 30
days to prevent malfunction. (Use caution regarding
the air supply.)
4. Manual override operation
When the manual override is operated, connected
equipment will be actuated.
Operate after safety is confirmed.
Caution
VQ1000/2000 Series
Precautions for 5 Port Solenoid Valve
Be sure to read before handling. Refer to main text for detailed precautions on every series.
Warning
Warning
- 7 -