- 2 -
Contents
Introduction....................................................................................................3
1. Installation of [AC Servo Drive Capacity Selection
Program/SigmaJunmaSize+] ........................................................................4
2. Regenerative Resistance Calculation Method ........................................7
2.1 Startup of [AC Servo Drive Capacity Selection Program/SigmaJunmaSize+] 7
2.2 「Main menu」-「Wizard Sizing」............................................................................ 8
2.3 『Units』setting...................................................................................................... 8
2.4 Selection of [Mechanism].................................................................................... 9
2.5 [Ball screw (Horizontal)] setting ....................................................................... 10
2.5.1 Input value of LEFS (Ball screw) ...........................................................................10
2.5.2 Input value of LEJS (Ball screw)............................................................................11
2.5.3 Input value of LEY (Ball screw)..............................................................................12
2.5.4 Input value of LEYG (Ball screw)...........................................................................13
2.5.5 Setting of Drive Condition "Ball screw (Horizontal)" ........................................14
2.6 [Ball screw (Vertical)] setting............................................................................ 15
2.6.1 Input value of LEFS (Ball screw) ...........................................................................16
2.6.2 Input value of LEJS (Ball screw)............................................................................17
2.6.3 Input value of LEY (Ball screw)..............................................................................18
2.6.4 Input value of LEYG (Ball screw)...........................................................................19
2.6.5 Setting of drive condition "Ball screw (Vertical)" ..............................................20
2.7 [Timing belt (Horizontal)] setting...................................................................... 21
2.7.1 Input value of LEFB (Timing belt)..........................................................................22
2.7.2 Input value of LEJB (Timing belt) ..........................................................................22
2.7.3 Setting of drive condition [Timing belt (Horizontal)]". .........................................23
2.8 [Operating condition] setting............................................................................ 24
2.9 [Motor selection] setting................................................................................. 25
2.10 [External Regenerative Resistance "Capacity"/"Resistance"] Check ......... 26