Water Level Meter Indicator Light Replacement
High Quality Groundwater and Surface Water Monitoring Instrumentation
(Page 1 of 2)
Model 101/102/102M Mk2
Back of Mk2 Model 101 Water Level Meter Faceplate with
Older Style Light
Push-Release
Fittings
Note: To replace the light in an Mk1 Water Level Meter (yellow circuit
board and tape Molex connection), you will require the Mk2
Circuit Board Assembly (#102977), which includes the light.
Contact Solinst for the repair part and instructions.
Instructions
For Mk2 Water Level Meters (Push-Release Tape Connection)
1. Remove the battery (battery is located inside the reel hub of
a 102M Mini Water Level Meter. Remove the batttery after
Step 2).
2. Unscrew the three screws and remove the faceplate.
3. Press down on the white terminals of the push-release
fittings on the circuit board and pull out to remove the
tape/cable leads.
4. If you have an older style light (leads connected to Sonalert
terminals – see photos below), cut the red and black wires
connected to the light, and push the light out through the
front of the faceplate.
Back of Mk2 Model 101 Water Level Meter Faceplate with
New Style Light
Light
Light Connections
Light
Push-Release
Fittings
5. From the front of the faceplate, use the wrench to unscrew
the nut holding the test button and push the button back
out of the faceplate.
6. Unscrew and remove the two screws holding the circuit
board (and older style light leads) from the Sonalert.
7. Carefully lift the circuit board from the Sonalert so you have
better access to the circuit board.
8. If you have a newer style light, unsolder it from the circuit
board and remove as much of the old solder as possible.
9. If you had an older style light (or the lens needs replacing)
insert the new red lens through the front opening in the
faceplate and secure using the white nut.
10. For a Model 101 or 102 Water Level Meter, insert the
leads of the new light into the two positions labelled “D2”
on the circuit board and solder in place. See photo below.
Back of Mk2 Model 102M Mini Water Level Meter Faceplate
with Older Style Light
Light
Light Connections
Push-Release
Fittings
Light (under
circuit board)
Push-Release
Fittings
Back of Mk2 Model 102M Mini Water Level Meter
Faceplate with New Style Light
Continued overleaf...
Tools and Materials Needed
1. WLM Replacement LED (Light) Assembly (Spare) (#113923)
2. Phillips Screwdriver
3. 10 mm (3/8") Wrench
4. Wire Cutters (if required)
5. Wire Strippers (if required)
6. Solder Wire with Flux
7. Soldering Iron
D2
Printed in Canada
June 5, 2018
(#113922)
(Page 2 of 2)
For further information contact: Solinst Canada Ltd.
Fax: +1 (905) 873-1992; (800) 516-9081 Tel: +1 (905) 873-2255; (800) 661-2023
35 Todd Road, Georgetown, Ontario Canada L7G 4R8
Web Site: www.solinst.com E-mail: [email protected]
11. For a Model 102M Mini Water Level Meter, insert the
leads of the new light into the two positions labelled “D4”
on the circuit board and solder in place (“D4” positions are
located next to “D2” positions). See photo above.
12. Place the circuit board assembly back into position on top
of the Sonalert, ensuring the sides marked +ve and -ve are
lined up with the corresponding terminals on the Sonalert
and the new light seated in the lens.
13. Reinstall the two screws to connect the bare wires from the
circuit board to the terminals on the Sonalert.
14. Insert the test button through the opening in the faceplate,
and secure it in place using the nut.
15. For 101 Water Level Meters, connect the tape to the circuit
board assembly by pressing down on the white terminals
on the circuit board and inserting the tape leads. Release
the terminals and the leads should be secured. The lead on
the bottom of the tape (numbers facing up, may be black
mark on lead) is inserted into the terminal with a white
square below it on the circuit board.
Square
D4
Square
16. For 102 and 102M Water Level Meters, connect the cable
to the circuit board assembly by pressing down on the
white terminals on the circuit board and inserting the leads.
Release the terminals and the leads should be secured.
The positive lead is inserted into the terminal with a white
square below it on the circuit board. (The positive lead has
the pin connected to insulated wire, the negative pin is
connected to the braided wire).
17. Install the battery.
18. With the probe in a glass of tap water, turn the Water Level
Meter to the ‘ON’ position. If the connections are correct
the light will activate. If the light does not activate, check all
connections and the polarity of the battery.
19. Reattach the faceplate to the reel using the three screws.

This manual suits for next models

2

Other Solinst Measuring Instrument manuals

Solinst 101 Operating and safety instructions

Solinst

Solinst 101 Operating and safety instructions

Solinst 102 Operating and safety instructions

Solinst

Solinst 102 Operating and safety instructions

Solinst 122M User manual

Solinst

Solinst 122M User manual

Solinst 615 ML User manual

Solinst

Solinst 615 ML User manual

Solinst Levelogger 3001 User manual

Solinst

Solinst Levelogger 3001 User manual

Solinst 102M User manual

Solinst

Solinst 102M User manual

Solinst 101D User manual

Solinst

Solinst 101D User manual

Solinst 101M User manual

Solinst

Solinst 101M User manual

Solinst 101 Operating and safety instructions

Solinst

Solinst 101 Operating and safety instructions

Solinst 122 User manual

Solinst

Solinst 122 User manual

Solinst 104 User manual

Solinst

Solinst 104 User manual

Solinst 102 User manual

Solinst

Solinst 102 User manual

Solinst 101 P7 SC1000 User manual

Solinst

Solinst 101 P7 SC1000 User manual

Solinst 122M User manual

Solinst

Solinst 122M User manual

Solinst 101 P2 Operating and safety instructions

Solinst

Solinst 101 P2 Operating and safety instructions

Solinst 401 User manual

Solinst

Solinst 401 User manual

Solinst 102 User manual

Solinst

Solinst 102 User manual

Solinst 101 Operating and safety instructions

Solinst

Solinst 101 Operating and safety instructions

Solinst 101 User manual

Solinst

Solinst 101 User manual

Solinst 101 P7 User manual

Solinst

Solinst 101 P7 User manual

Solinst 201 User manual

Solinst

Solinst 201 User manual

Solinst Levelogger 3001 Use and care manual

Solinst

Solinst Levelogger 3001 Use and care manual

Solinst Levelogger Series User manual

Solinst

Solinst Levelogger Series User manual

Solinst LevelSender 5 User manual

Solinst

Solinst LevelSender 5 User manual

Popular Measuring Instrument manuals by other brands

Compass GOPLANET Mars 100 User's operation manual

Compass

Compass GOPLANET Mars 100 User's operation manual

Maplin Gadget N35HN instruction manual

Maplin Gadget

Maplin Gadget N35HN instruction manual

Lambda OXYMETER CALIBRATION PROCEDURE

Lambda

Lambda OXYMETER CALIBRATION PROCEDURE

Palas Fidas 200 Series operating manual

Palas

Palas Fidas 200 Series operating manual

KERN&SOHN ABP operating instructions

KERN&SOHN

KERN&SOHN ABP operating instructions

Bellingham and Stanley Abbe 60 user guide

Bellingham and Stanley

Bellingham and Stanley Abbe 60 user guide

Eaton Crouse-hinds series manual

Eaton

Eaton Crouse-hinds series manual

PCB Piezotronics ICP IMI SENSORS 626B11 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP IMI SENSORS 626B11 Installation and operating manual

Hanna Instruments HI 721 quick start guide

Hanna Instruments

Hanna Instruments HI 721 quick start guide

Trotec BM31-XT quick start guide

Trotec

Trotec BM31-XT quick start guide

Lisle Digidown Blue operating instructions

Lisle

Lisle Digidown Blue operating instructions

Keysight Technologies 1130B Series user guide

Keysight Technologies

Keysight Technologies 1130B Series user guide

Ceyear 2498C user manual

Ceyear

Ceyear 2498C user manual

Keysight HSA N9342C Demonstration Guide

Keysight

Keysight HSA N9342C Demonstration Guide

Keysight N9020B Installation note

Keysight

Keysight N9020B Installation note

Mitutoyo QuantuMike MDE-MX user manual

Mitutoyo

Mitutoyo QuantuMike MDE-MX user manual

Flowserve IPS-Beacon VB-105 Installation operation & maintenance

Flowserve

Flowserve IPS-Beacon VB-105 Installation operation & maintenance

ELIT 420 instruction manual

ELIT

ELIT 420 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.