EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SOMFY
  6. •
  7. Recording Equipment
  8. •
  9. SOMFY SDN 0-10V Interface V2 User manual

SOMFY SDN 0-10V Interface V2 User manual

Other manuals for SDN 0-10V Interface V2

1

This manual suits for next models

1

Other SOMFY Recording Equipment manuals

SOMFY Tridonic animeo User manual

SOMFY

SOMFY Tridonic animeo User manual

SOMFY TaHoma RTS/Zigbee Smartphone and Tablet... Quick setup guide

SOMFY

SOMFY TaHoma RTS/Zigbee Smartphone and Tablet... Quick setup guide

SOMFY ZigBee User manual

SOMFY

SOMFY ZigBee User manual

SOMFY NeoControl CUBEE NEO-CUB-BL User manual

SOMFY

SOMFY NeoControl CUBEE NEO-CUB-BL User manual

SOMFY DCT2RTS User manual

SOMFY

SOMFY DCT2RTS User manual

SOMFY DCT2RTS User manual

SOMFY

SOMFY DCT2RTS User manual

SOMFY Neocontrol SLIMTOUCH NEO-SLT-BL User manual

SOMFY

SOMFY Neocontrol SLIMTOUCH NEO-SLT-BL User manual

SOMFY ZDMI User manual

SOMFY

SOMFY ZDMI User manual

SOMFY CONTROL4 Operating instructions

SOMFY

SOMFY CONTROL4 Operating instructions

SOMFY animeo 1860161 User manual

SOMFY

SOMFY animeo 1860161 User manual

SOMFY TaHoma Operating instructions

SOMFY

SOMFY TaHoma Operating instructions

SOMFY Connect UAI User manual

SOMFY

SOMFY Connect UAI User manual

SOMFY TaHoma Operating instructions

SOMFY

SOMFY TaHoma Operating instructions

SOMFY DCT2RTS User manual

SOMFY

SOMFY DCT2RTS User manual

SOMFY 1810607 User manual

SOMFY

SOMFY 1810607 User manual

SOMFY Sonesse 40 RTS User manual

SOMFY

SOMFY Sonesse 40 RTS User manual

SOMFY 1810815 User manual

SOMFY

SOMFY 1810815 User manual

SOMFY SDN 0-10V Interface V2 Operating instructions

SOMFY

SOMFY SDN 0-10V Interface V2 Operating instructions

SOMFY 9018247 Specification sheet

SOMFY

SOMFY 9018247 Specification sheet

SOMFY 1860333 User manual

SOMFY

SOMFY 1860333 User manual

SOMFY Connect Operating instructions

SOMFY

SOMFY Connect Operating instructions

SOMFY URTSI 2 Quick setup guide

SOMFY

SOMFY URTSI 2 Quick setup guide

SOMFY 1810872 User manual

SOMFY

SOMFY 1810872 User manual

Popular Recording Equipment manuals by other brands

Philips CDR 765 null

Philips

Philips CDR 765 null

Philips CDR770 null

Philips

Philips CDR770 null

KV2 Audio 500 Series user guide

KV2 Audio

KV2 Audio 500 Series user guide

Robotics Technologies microBus-Cam II installation manual

Robotics Technologies

Robotics Technologies microBus-Cam II installation manual

Seca 460 quick start guide

Seca

Seca 460 quick start guide

Cognex MVS-8000 Series Hardware manual

Cognex

Cognex MVS-8000 Series Hardware manual

Mect MPNC006 Series user manual

Mect

Mect MPNC006 Series user manual

Bad Caf THE LEASH operating manual

Bad Caf

Bad Caf THE LEASH operating manual

Strymon NIGHTSKY user manual

Strymon

Strymon NIGHTSKY user manual

Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U user manual

Mitsubishi Electric

Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U user manual

Tews Technologies TPMC465 user manual

Tews Technologies

Tews Technologies TPMC465 user manual

Honeywell Excel 50 user guide

Honeywell

Honeywell Excel 50 user guide

SeaLevel COMM+8.LPCI user manual

SeaLevel

SeaLevel COMM+8.LPCI user manual

Arturia AUDIOFUSE STUDIO user manual

Arturia

Arturia AUDIOFUSE STUDIO user manual

Rukra RK-1240 quick start guide

Rukra

Rukra RK-1240 quick start guide

Samson SCOM owner's manual

Samson

Samson SCOM owner's manual

Dynacord DPS260 owner's manual

Dynacord

Dynacord DPS260 owner's manual

Pyle Pro PSS8 manual

Pyle Pro

Pyle Pro PSS8 manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

SDN 0-10V Interface V2
Part Number: 1870857
2
SDN 0-10V Interface V2
The SDN 0-10V Interface control is
a device that will accept an industry
standard 0-10V dimming signal and
convert it to a Somfy Digital Network™
(SDN) signal. TThe SDN signal can
drive a single or multiple Somfy RS485
motors via assigned group addresses.
Key features include:
• One control can drive up to
30 SDN tubular motors.
• Provides 20 SDN Bus
Power units
MOTOR %
POSITION
MOTOR
INTERMEDIATE
POSITION
.750 V 0% IP1
1.088 V 10% IP2
2.037 V 20% IP3
2.973 V 30% IP4
3.901 V 40% IP5
4.897 V 50% IP6
5.813 V 60% IP7
6.73 V 70% IP8
7.71 V 80% IP9
8.66 V 90% IP10
9.58 V 100% IP11
MOTOR %
POSITION
MOTOR
INTERMEDIATE
POSITION
.750 V 0% IP1
1 V 10% IP2
2 V 20% IP3
3 V 30% IP4
4 V 40% IP5
5 V 50% IP6
6 V 60% IP7
7 V 70% IP8
8 V 80% IP9
9 V 90% IP10
1. Verify that the limits of the RS485 motor are set and the power to the motor is applied.
2. Connect the motor data cable and the 0-10V input according to Figure 1. Do not connect the 120V AC power supply
at this time.
*NOTE* VERIFY THE POLARTIY OF THE 0-10V POSITIVE (+) PURPLE AND NEGATIVE (-) PINK INPUTS BEFORE
APPLYING POWER.
3. Connect the SDN 0-10V Interface and turn on the AC power. Then verify that the Main Power LED on the Bus Out jack
is solid green. The Bus Activity LED turns on for 10 seconds then turns off.
4. Verify that the motor responds by a single press of the pin-hole push button.
SETUP (Please refer to the programming guide on the product page for step-by-step instructions.)
INSTALLATION AND WIRING
Line/Hot
Black wire
Line Voltage and
0-10V Dimming
SDN Bus
Negative (-)
Pink wire
SDN 0-10V
Interface V2
Connects to an
SDN Bus-in Port
or a Device Port
Neutral
White wire
Positive (+)
Purple wire
3
SDN 0-10V Interface V2
ELEMENT FUNCTION
11/2” NPT Lock Nut Mounting accessory for the device
2DIP Switch Bank Configure operating modes
3Bank B DIP Switches Adjust to select specific SDN group address
4Bus Power Switch Turn bus power OFF or ON
5Bank A DIP Switches Adjust to select a specific control function
6Pin-Hole Push-Button
(A) sequence/motor testing;
(B) animeo discovery
(C) soware reset
LED Indicators
LABEL ELEMENT COLOR FUNCTION ON FUNCTION OFF
PMain Power Green Power No Power
ABus Activity Green Data No Data
SDN RS485 Tubular motors
(Sonesse® ULTRA 50 RS485 example shown)
0-10V
Input Motor Data Cable*
* use Black Data Cable
(see ordering information)
(purple)
(pink)
Sonesse® ULTRA 50 RS485 (AC)
Power Panel for SDN
Sonesse® ULTRA 50 RS485 (DC) Motor Pigtail Weidmueller Connectors SDN Low-voltage motor cable
120V AC
60 HZ
(neutral) (line)
Line
Power
Supply
Notes:
For single motor operation, motor data cable connects directly to the SDN Data port.
This example shows the Data Hub while the Data Hub Mini and Power Panel for SDN are also compatible.
The diagram shown below is meant for illustrative purposes to show the connections from product to product. This
device could be used in other configurations than shown below. For specification information on individual products,
see related product information. Follow all SDN wiring standards for distance limitations.
CONNECTION DIAGRAM
CONNECTIONS & INDICATORS
A
P
Bottom Side
Right Side
1 2
345 Front Side
6
4
SDN 0-10V Interface V2
25000857 © Somfy Systems, Inc. 4/2022
ORDERING INFORMATION
DESCRIPTION PART NUMBER
SDN 0-10V Interface V2 1870857
SDN Data Hub 1870262
SDN Mini Data Hub 1870277
Line-voltage RS485 Motor Data Cables
2.5 .: 9018541
8 .: 9018542
12 .: 9018543
24 .: 9018544
Low voltage RS485 Motor Accessories
Power Panel for SDN 1870259
SDN Low-voltage Motor Power and Data Cable
Non Plenum
US#: 9020126
CA#: 9020452
Plenum
US#: 9020127
CA#: 9020453
Weidmuller Connector (5 pin) 9020743
Sonesse® 30 DC RS485 Cable Data and Power Pigtail 9020261
Sonesse® ULTRA 50 DC RS485 Cable Data and Power Pigtail 9020004
4 Not Connected*
Power Out**
1 + RS485
2 - RS485
3 Not Connected
8 GND
7 Not Connected
6 Not Connected
5 Not Connected
1 + RS485
2 - RS485
4 GND
3 Not Connected*
Power Out**
Motor Data Cable
BLACK DATA CABLE (without power out)
4 Cond. 26AWG modular cable with RJ9 on one end
and RJ45 other end
MOTOR DATA CABLE INFORMATION
Line-voltage (AC):
• Sonesse® ULTRA 50 RS485 (AC)
• Sonesse® 50 RS485
• LT50 RS485 (AC)
• Glydea® ULTRA RS485
MOTOR COMPATIBILITY
Low-voltage (DC):
• Sonesse® ULTRA 50 RS485 (DC)
• Sonesse® 30 RS485 (DC)
9020126 - Non-plenum Rated
Orange = SDN RS485 (-)
Orange/white = SDN RS485 (+)
Red = power (+)
Black = power (-)
Brown = groundSDN RS485
Silver = Drain
Data and Power Cable
24V DC / SDN Control
5 conductor cable
Somfy SDN Low-voltage Motor Cable
9020127 - Plenum Rated
Sonesse® ULTRA 50 RS485
Data and Power Pigtail
Sonesse® 30 RS485 Data and
Power Pigtail
Low-Voltage (DC)
Weidmuller Connects
to Network
JST to Motor
Line-Voltage (AC)
Weidmuller Connector (5 pin) SDN Low-voltage Motor
Power and Data Cable
9020127 - Plenum Rated
9020126 - Non-plenum Rated
For more information visit: www.somfypro.com/products/-/e-cat//1870857
OFFICE LOCATIONS
New Jersey
121 Herrod Blvd.
Dayton, NJ 08810
P: (800) 22-SOMFY (76639) .F: (609) 395-1776
Florida
1200 SW 35th Ave.
Boynton Beach, FL 33426
P: (800) 22-SOMFY (76639) .F: (561) 995-7502
California
15301 Barranca Pkwy
Irvine, CA 92618
P: (800) 22-SOMFY (76639) .F: (949) 727-3775
Canada
6411 Edwards Blvd
Mississauga, Ontario L5T 2P7
P: 1-800-66-SOMFY .CN: (905) 564-6446
F: (905) 238-1491